KSKeisuke Shima

Keisuke Shima

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Keisuke Shima has a total of 144 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Evaluation of Subepoch Time–Frequency Representations for Clinical PSG-Based Sleep Staging

    by Keigo Tomihama, Takayuki Mukaeda, Keisuke Shima, Kuniharu Takei, Nanako Shiroshita, Nobuyuki Kagiyama, Takatoshi Kasai

  • Open Access

    Effects of Fingertip Vibrotactile Stimulation on Postural Control in Community-Dwelling Older Adults: A Comparison Across Age Groups

    by Takato Nishida, Shin Murata, Ryosuke Yamamoto, Shun Sawai, Shoya Fujikawa, Yusuke Shizuka, Naoki Shimizu, Koji Shimatani, Keisuke Shima, Hideki Nakano

    Age-related decline in postural control is an important factor that increases the fall risk of older adults. Fingertip vibrotactile stimulation has been developed to provide light touch-like somatosensory input. However, evidence regarding differences among older age groups is limited. This study examined the effects of fingertip vibrotactile stimulation on postural control in 348 community-dwelling older adults classified as young-old (age 65-74 years), old-old (age 75-84 years), and oldest-old (age 85 years or older). Participants stood with eyes closed and feet together under stimulation and no stimulation conditions. The center of pressure (COP) velocity and COP area were measured using a force plate. The natural log-transformed COP area was used for the analysis. Linear mixed models were used to examine the effects of age group, stimulation conditions, and measurement segments. The COP velocity under the stimulation condition was significantly lower than that under the no stimulation condition; however, the COP area did not change significantly. Significant main effects of age group were observed for both COP indices, but no interaction between age group and stimulation condition was observed. Fingertip vibrotactile stimulation may reduce the COP velocity across older age groups, thus reflecting the effects on postural adjustment frequency.

  • Open Access

    Dynamic Structural Change Detection and Its Effect on Dynamic Stability in Segment Synergy during Sit-to-Stand Transition with Healthcare Robot Assistance

    by Tianyi Wang, Keisuke Shima, Yuko Ohno

    This study investigated dynamic structural changes and their implications for dynamic stability during Sit-to-Stand (STS) transitions with healthcare robot assistance. The STS movement, a fundamental activity for mobility and independence, poses challenges for older adults due to age-related declines in muscle strength and joint integrity, increasing fall risk. Assistive robots, typically categorized into upper- and lower-limb support systems, have been developed to mitigate this risk. However, conventional biomechanical assessments fail to capture the nonlinear, time-varying coordination patterns essential for maintaining dynamic stability in Human–Robot Interaction (HRI). To address this gap, we introduced nonlinear analytical techniques to detect dynamic structural changes during STS transitions under three experimental conditions: self-performed, passive robot-assisted, and proactive robot-assisted STS. Motion capture data from 14 healthy participants were analyzed, with segment synergies quantified through relative phase analysis of the trunk, knee, and ankle. A segment-synergy-based segmentation algorithm based on dynamic correlation exponents was developed to detect phase transitions in synergy dynamics. Complementary nonlinear-dynamics measures—maximum Lyapunov exponent, sample entropy, and detrended fluctuation analysis—were employed to assess dynamic stability. Results showed that passive assistance induced earlier but less synchronized transitions than self-performed STS, whereas proactive assistance preserved natural timing and enhanced intersegmental coordination stability. Temporal dissociation between knee–trunk and ankle–knee synergy transitions emerged as a potential predictor of dynamic stability outcomes. These findings underscore the importance of phase-sensitive control algorithms in assistive robotics for achieving biologically congruent HRI. By bridging biomechanical insights with advanced analytical methods, this study provides a critical step toward the design of healthcare robots that enhance mobility and reduce fall risk.

  • Open Access

    A Training System for Human Standing Stability Using Virtual Viscosity Fields

    by Hayato Mikami, Keisuke Shima, Tianyi Wang, Haruto Kai, Koji Shimatani

    Enhancement of postural stability in standing is essential for fall prevention in the context of demographic aging. Against such a background, this study proposes a personalized training system based on individual limits of stability (LOS) for a human standing state. The system evaluates LOS in eight directions using center-of-mass (COM) and center-of-pressure (COP) measurement devices and provides game-based feedback, then promotes balance within the relevant LOS parameters. Loading is individualized by applying greater force to virtual objects as the COP approaches the LOS determined for each subject. Experiments with 32 younger and 19 mature subjects produced evaluations for postural stability index (IPS), LOS area, and COP sway. The results revealed two distinct response patterns: LOS expansion and sway reduction, both observed across younger and mature cohorts. These findings suggest that individualized LOS-based training can be applied to improve standing stability with two distinct strategies. These preliminary findings suggest that individualized LOS-based training is associated with changes in standing stability through two distinct response patterns.


  • Open Access

    Lower Extremity Function Evaluation System at the Workplace Using Azure Kinect

    by Hayato Mikami, Mami Sakata, Keisuke Shima, Tomoyuki Nagara, Makiko Yamashita, Koji Shimatani

    In this paper, we developed a quantitative and detailed evaluation system for the single-leg standing test and clarified the relationship between evaluation results and lower extremity function. The proposed method uses the Azure Kinect to estimate joint coordinates, calculate joint angles, and represent standing motion as a state transition model. The center of mass was estimated and used as an evaluation index. In the evaluation experiment, 41 subjects were measured, and it was confirmed that the proposed system could calculate the same evaluation values as an athletic trainer with high accuracy. It was also confirmed that the shape of the radar chart consisting of the 14 indicator groups was different for each subject. Furthermore, the results were compared with the physical fitness test data, and it was found that these results were related to three lower extremity functions: lower-extremity muscle strength, quadriceps muscle and hip flexibility, and hamstring flexibility. By reconstructing the radar chart with only the most relevant indicators, we were able to provide more specific feedback on lower extremity function. Cluster analysis suggests the possibility of detecting clusters with similar physical functions.The proposed system is capable of quantitative and detailed evaluations, even in the absence of skilled evaluators.

  • Open Access

    A new biomarker for screening Hiesho (cold hypersensitivity) in young females through measurement of the foot temperature-recovery rate after a cooling test

    by Tianyi Wang, Keisuke Shima, Yuko Ohno, Masayuki Endo

    Hiesho (cold hypersensitivity) is a common condition in Japan and other Asian countries, particularly among females, and has substantial health implication

  • Open Access

    Investigation of Motor Learning Effects Using a Hybrid Rehabilitation System Based on Motion Estimation

    by Kensuke Takenaka, Keisuke Shima, Koji Shimatani

    Upper-limb paralysis requires extensive rehabilitation to recover functionality for everyday living, and such assistance can be supported with robot technology. Against such a background, we have proposed an electromyography (EMG)-driven hybrid rehabilitation system based on motion estimation using a probabilistic neural network. The system controls a robot and functional electrical stimulation (FES) from movement estimation using EMG signals based on the user’s intention, enabling intuitive learning of joint motion and muscle contraction capacity even for multiple motions. In this study, hybrid and visual-feedback training were conducted with pointing movements involving the non-dominant wrist, and the motor learning effect was examined via quantitative evaluation of accuracy, stability, and smoothness. The results show that hybrid instruction was as effective as visual feedback training in all aspects. Accordingly, passive hybrid instruction using the proposed system can be considered effective in promoting motor learning and rehabilitation for paralysis with inability to perform voluntary movements.


  • Open Access

    A wearable light-touch contact device for human balance support

    by Keisuke Shima, Koji Shimatani, Mami Sakata

    There is an urgent need for the development of ways to address the major issue of falls among today’s globally aging population. The authors here outline a new approach referred to as virtual light-touch contact to mitigate postural sway during ambulatory and stationary periods, and propose a wearable light-touch (WLT) system featuring a virtual partition around the user that allows determination of virtual forces resulting from related contact. The data produced are used to create vibrotactile fingertip feedback, which supports comprehensive perception of the partition. Non-impaired subjects were recruited to support evaluation of the prototype system (incorporating tactile stimulation and motion-capture technology), with outcomes showing successful mitigation of postural sway in a heel-to-toe tandem stance. Research performed with 150 able-bodied volunteers to validate the performance of the new set-up (incorporating an acceleration sensor and a voice coil motor to render the light-touch effect) suggested that the proposed WLT approach supports human balance on a level comparable to that of the light-touch effect.


  • Spontaneous movements in the newborns: a tool of quantitative video analysis of preterm babies

    by Chiara Tacchino, Martina Impagliazzo, Erika Maggi, Marta Bertamino, Isa Blanchi, Francesca Campone, Paola Durand, Marco Fato, Psiche Giannoni, Riccardo Iandolo, et al.


  • Improved MALDI‐MS method for the highly sensitive and reproducible detection of biomarker peaks for the proteotyping of Salmonella serotypes

    by Yuko Fukuyama, Teruyo Ojima‐Kato, Satomi Nagai, Keisuke Shima, Shinji Funatsu, Yoshihiro Yamada, Hiroto Tamura, Shizuo Nomura, Koretsugu Ogata, Sadanori Sekiya, et al.

    The rapid identification and classification of pathogenic microorganisms, including Salmonella enterica, is important for the surveillance and prevention of foodborne diseases. Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOFMS) has been shown to be an effective tool for the rapid identification of microorganisms. In a previous report, a mass database consisting of twelve biomarker proteins, S8, L15, L17, L21, L25, S7, superoxide dismutase (SodA), peptidylprolyl cis‐trans isomerase C, Gns, YibT, YaiA and YciF, was introduced for the serotyping of Salmonella enterica via MALDI‐MS (Applied Microbiology and Biotechnology, 2017, 101, 8557‐8569). However, the reproducibility of peak detection of biomarkers such as SodA at m/z 23,000 was poor. We report here an optimized MALDI‐MS method for detecting these biomarkers with high sensitivity and reproducibility. The issue was solved by controlling the bacterial concentration at 1×10~1×102 MFU (3×106~3×107 CFU/μL, as calculated from the MFU), using the colony suspension supernatant obtained by centrifugation, and using matrix additives such as methylenediphosphonic acid and N‐decyl‐β‐D‐maltopyranoside. We propose that the method including the above steps is one of the best for detecting biomarkers with high sensitivity and reproducibility.