Renato Mio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Renato Mio has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Dante A. Elias
Pontificia Universidad Católica del Perú
3 shared publications Giancarlo Salazar
Pontificia Universidad Católica del Perú
3 shared publications- Midori Sanchez
Pontifícia Universidad Católica del Perú, Lima, Peru
3 shared publications - Alyssa N. Maguina
University of Maryland, Baltimore County, Baltimore, USA
2 shared publications Kevin M. Flores
Laboratory of Biomechanics and Applied Robotics, Pontificia Universidad Católica del Perú (PUCP), Lima, Perú
2 shared publicationsLuis Ccorimanya
Laboratory of Biomechanics and Applied Robotics, Pontificia Universidad Católica del Perú (PUCP), Lima, Perú
2 shared publications
Latest Publications
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE International Conference on Rehabilitation Robotics (ICORR)
- Vol. 2025, 1065-1070
A Body-Powered Wrist-Driven Supernumerary Robotic Finger
Individuals with grasping impairments face significant challenges in performing daily tasks due to reduced hand function. Existing supernumerary robotic fingers (SRFs) often rely on electronic components that limit their usability through added weight and power constraints. This work introduces the first body-powered wrist-driven SRF (bpSRF), a design that addresses these limitations by removing all electronic components. The proposed bpSRF weighs 52 g and is mostly made of 3D printed parts. Using body-powered actuation principles, the extra finger is driven by wrist movements, offering a practical, affordable, and lightweight solution for hand augmentation. The bpSRF has two degrees of freedom, enabling users to perform enhanced grasping techniques with minimal learning curve. Experimental validation with five healthy participants showed high success rates and rapid learning of novel grasping patterns for tasks involving large or multiple objects that typically require two hands. The design offers a workspace volume approximately three times larger than a human thumb, potentially expanding users' manipulation capabilities. This research contributes to a new paradigm in assistive technology, presenting a lightweight, cost-effective, and open source SRF that can enhance grasping abilities for individuals with motor impairments while also offering augmentation possibilities for healthy users.
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE International Conference on Rehabilitation Robotics (ICORR)
- Vol. 2025, 1065-1070
A Body-Powered Wrist-Driven Supernumerary Robotic Finger
Individuals with grasping impairments face significant challenges in performing daily tasks due to reduced hand function. Existing supernumerary robotic fingers (SRFs) often rely on electronic components that limit their usability through added weight and power constraints. This work introduces the first body-powered wrist-driven SRF (bpSRF), a design that addresses these limitations by removing all electronic components. The proposed bpSRF weighs 52 g and is mostly made of 3D printed parts. Using body-powered actuation principles, the extra finger is driven by wrist movements, offering a practical, affordable, and lightweight solution for hand augmentation. The bpSRF has two degrees of freedom, enabling users to perform enhanced grasping techniques with minimal learning curve. Experimental validation with five healthy participants showed high success rates and rapid learning of novel grasping patterns for tasks involving large or multiple objects that typically require two hands. The design offers a workspace volume approximately three times larger than a human thumb, potentially expanding users' manipulation capabilities. This research contributes to a new paradigm in assistive technology, presenting a lightweight, cost-effective, and open source SRF that can enhance grasping abilities for individuals with motor impairments while also offering augmentation possibilities for healthy users.
- 2 April 2025
- Published by Springer Nature
- p. 115-119
Motor Unit Decomposition Over Intrinsic Hand Muscles During Single and Multi-finger Flexion
- 2 April 2025
- Published by Springer Nature
- p. 115-119
Motor Unit Decomposition Over Intrinsic Hand Muscles During Single and Multi-finger Flexion
- Open Access
- 18 December 2024
- Published by MDPI AG in Biomechanics
- Vol. 4 (4) , 784-804
Impact of Contralateral Hemiplegia on Lower Limb Joint Kinematics and Dynamics: A Musculoskeletal Modeling Approach
This study investigates the biomechanical differences between typically developed (TD) individuals and those with contralateral hemiplegia (CH) using musculoskeletal modeling in OpenSim. Ten TD participants and ten CH patients were analyzed for joint angles and external joint moments around the three anatomical axes: frontal, sagittal, and transverse. The analysis focused on hip, pelvis, lumbar, knee, ankle, and subtalar joint movements, leveraging MRI-derived bone length data and gait analysis. Significant differences (p < 0.05) were observed in hip flexion, pelvis tilt, lumbar extension, and ankle joint angles, highlighting the impact of hemiplegia on these specific joints. However, parameters like hip adduction and rotation, knee moment, and subtalar joint dynamics did not show significant differences, with p > 0.05. The comparison of joint angle and joint moment correlations between TD and CH participants highlights diverse coordination patterns in CH. Joint angles show significant shifts, such as HF and LR (−0.35 to −0.97) and PR and LR (0.22 to −0.78), reflecting disrupted interactions, while others like HR and LR (0.42 to 0.75) exhibit stronger coupling in CH individuals. Joint moments remain mostly stable, with HF and HA (0.54 to 0.53) and PR and LR (−0.51 to −0.50) showing negligible changes. However, some moments, like KA and HF (0.11 to −0.13) and PT and KA (0.75 to 0.67), reveal weakened or altered relationships. These findings underscore biomechanical adaptations and compensatory strategies in CH patients, affecting joint coordination. Overall, CH individuals exhibit stronger negative correlations, reflecting impaired coordination. These findings provide insight into the musculoskeletal alterations in hemiplegic patients, potentially guiding the development of targeted rehabilitation strategies.
- 18 December 2024
- Published by MDPI AG in Biomechanics
- Vol. 4 (4) , 784-804
Open AccessImpact of Contralateral Hemiplegia on Lower Limb Joint Kinematics and Dynamics: A Musculoskeletal Modeling Approach
This study investigates the biomechanical differences between typically developed (TD) individuals and those with contralateral hemiplegia (CH) using musculoskeletal modeling in OpenSim. Ten TD participants and ten CH patients were analyzed for joint angles and external joint moments around the three anatomical axes: frontal, sagittal, and transverse. The analysis focused on hip, pelvis, lumbar, knee, ankle, and subtalar joint movements, leveraging MRI-derived bone length data and gait analysis. Significant differences (p < 0.05) were observed in hip flexion, pelvis tilt, lumbar extension, and ankle joint angles, highlighting the impact of hemiplegia on these specific joints. However, parameters like hip adduction and rotation, knee moment, and subtalar joint dynamics did not show significant differences, with p > 0.05. The comparison of joint angle and joint moment correlations between TD and CH participants highlights diverse coordination patterns in CH. Joint angles show significant shifts, such as HF and LR (−0.35 to −0.97) and PR and LR (0.22 to −0.78), reflecting disrupted interactions, while others like HR and LR (0.42 to 0.75) exhibit stronger coupling in CH individuals. Joint moments remain mostly stable, with HF and HA (0.54 to 0.53) and PR and LR (−0.51 to −0.50) showing negligible changes. However, some moments, like KA and HF (0.11 to −0.13) and PT and KA (0.75 to 0.67), reveal weakened or altered relationships. These findings underscore biomechanical adaptations and compensatory strategies in CH patients, affecting joint coordination. Overall, CH individuals exhibit stronger negative correlations, reflecting impaired coordination. These findings provide insight into the musculoskeletal alterations in hemiplegic patients, potentially guiding the development of targeted rehabilitation strategies.
- 4 January 2024
- Published by Springer Nature
- p. 519-529
Augmented Grasps: Supernumerary Robotic Fingers and Their Practical Uses
- 4 January 2024
- Published by Springer Nature
- p. 519-529
Augmented Grasps: Supernumerary Robotic Fingers and Their Practical Uses
- 4 January 2024
- Published by Springer Nature
- p. 621-632
One-To-Many Actuation Mechanism for a 3D-Printed Anthropomorphic Hand Prosthesis
- 4 January 2024
- Published by Springer Nature
- p. 621-632
One-To-Many Actuation Mechanism for a 3D-Printed Anthropomorphic Hand Prosthesis
- 17 May 2019
- Published by Springer Nature
- p. 81-92
Characteristics of a Lower Limb Exoskeleton for Gait and Stair Climbing Therapies
- 17 May 2019
- Published by Springer Nature
- p. 81-92
Characteristics of a Lower Limb Exoskeleton for Gait and Stair Climbing Therapies
- 17 May 2019
- Published by Springer Nature
- p. 93-102
A 3D-Printed Prosthetic Hand with Modular Reconfigurable Fingers
- 17 May 2019
- Published by Springer Nature
- p. 93-102
A 3D-Printed Prosthetic Hand with Modular Reconfigurable Fingers
- Open Access
- 1 January 2019
- Published by ASTES Journal in Advances in Science, Technology and Engineering Systems Journal
- Vol. 4 (5) , 61-68
Mechanical Testing Methods for Body-Powered Upper-Limb Prostheses: A Case Study
- 1 January 2019
- Published by ASTES Journal in Advances in Science, Technology and Engineering Systems Journal
- Vol. 4 (5) , 61-68
Open AccessMechanical Testing Methods for Body-Powered Upper-Limb Prostheses: A Case Study
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 79-85
[Regular Paper] A Parametric 3D-Printed Body-Powered Hand Prosthesis Based on the Four-Bar Linkage Mechanism
The widespread of 3D-printing technology has resulted in the appearance of many open-source prosthetic hand models, especially for partial hand amputations. However, most of these designs are not editable and while some are parametric to some degree, customization for every user is limited to scaling the size of a base design. As consequence, most prostheses fail to closely match the user specific anthropometry and have poor aesthetics, which could result in abandonment of the device. Furthermore, achieving a high degree of customization could be a time-consuming task and requires previous knowledge of CAD design. This work presents a prosthetic hand easy to customize by changing parametric dimensions of the finger phalanges and palm on an Excel sheet. Additionally, the design tackles common issues from previous 3D-printed body-powered prosthetic hands by incorporating new features such as the use of linkages instead of cables as finger flexors and a new cable-adjusting system which requires no additional tools and makes the tensioning of finger tendons easier and quicker.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 79-85
[Regular Paper] A Parametric 3D-Printed Body-Powered Hand Prosthesis Based on the Four-Bar Linkage Mechanism
The widespread of 3D-printing technology has resulted in the appearance of many open-source prosthetic hand models, especially for partial hand amputations. However, most of these designs are not editable and while some are parametric to some degree, customization for every user is limited to scaling the size of a base design. As consequence, most prostheses fail to closely match the user specific anthropometry and have poor aesthetics, which could result in abandonment of the device. Furthermore, achieving a high degree of customization could be a time-consuming task and requires previous knowledge of CAD design. This work presents a prosthetic hand easy to customize by changing parametric dimensions of the finger phalanges and palm on an Excel sheet. Additionally, the design tackles common issues from previous 3D-printed body-powered prosthetic hands by incorporating new features such as the use of linkages instead of cables as finger flexors and a new cable-adjusting system which requires no additional tools and makes the tensioning of finger tendons easier and quicker.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 170-176
[Regular Paper] Mechanical Testing Methods for Body-Powered Upper-Limb Prostheses: A Review
New manufacturing and rapid prototyping technologies have fueled the creation of affordable and easy to replicate upper-limb prostheses. In this matter, many types and designs of 3D-printed upper-limb prostheses have been created over the last years. However, there is no consensus in the testing methodology for these devices regarding their mechanical capabilities and the comparisons authors can make are limited to their own metrics, which could be considered as a subjective approach. In order to tackle this issue, this work revises the existing methods for testing both the mechanical resistance and the mechanical performance or efficiency of upper-limb prostheses; specifically, the ones that are relevant for 3D-printed body-powered prostheses. Then, the adaptations needed to apply these methods to 3D-printed prostheses are discussed. Finally, recommendations are given for prosthetists and researchers in order to execute reliable tests that can be compared across different hand prosthesis designs.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 170-176
[Regular Paper] Mechanical Testing Methods for Body-Powered Upper-Limb Prostheses: A Review
New manufacturing and rapid prototyping technologies have fueled the creation of affordable and easy to replicate upper-limb prostheses. In this matter, many types and designs of 3D-printed upper-limb prostheses have been created over the last years. However, there is no consensus in the testing methodology for these devices regarding their mechanical capabilities and the comparisons authors can make are limited to their own metrics, which could be considered as a subjective approach. In order to tackle this issue, this work revises the existing methods for testing both the mechanical resistance and the mechanical performance or efficiency of upper-limb prostheses; specifically, the ones that are relevant for 3D-printed body-powered prostheses. Then, the adaptations needed to apply these methods to 3D-printed prostheses are discussed. Finally, recommendations are given for prosthetists and researchers in order to execute reliable tests that can be compared across different hand prosthesis designs.