William James Murphy
William James Murphy has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Gregory A. Flamme
Stephenson and Stephenson Research and Consulting, LLC, 5706 State Route 132, Batavia, OH, 45103, USA
8 shared publications Christa L. Themann
Noise and Bioacoustics Team, Division of Field Studies and Engineering, National Institute for Occupational Safety and Health (NIOSH) 2 , 1090 Tusculum Avenue, Cincinnati, Ohio 45226-1998
3 shared publications- Kristy K. Deiters
SASRAC, Portage, MI
3 shared publications - Laurie Wells
63M Personal Safety Division, St. Paul, MN 55144-1000, USA
3 shared publications - Theresa Y. Schulz
Defense Health Agency, Hearing Center of Excellence, Joint Base San Antonio Lackland, TX 78236, USA
3 shared publications Wei Gong
Division of Field Studies and Engineering, National Institute for Occupational Safety and Health, Cincinnati, OH, 45226, USA
3 shared publications
Latest Publications
- 1 February 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 157 (2) , 940-946
Hearing threshold quartiles from the 1999–2006 National Health and Nutrition Examination Surveys
This report extends the development of normative standards for estimating occupational hearing loss using data from the United States National Health and Nutrition Examination Survey (NHANES) conducted by the National Center for Health Statistics. A proposed revision of the International Organization for Standardization (ISO) 1999:2013 standard (“Acoustics—Estimation on noise-induced hearing loss”) uses a linear interpolation of hearing threshold data to estimate the 25th and 75th percentiles for men and women at 500, 1000, 2000, 3000, 4000, 6000, and 8000 Hz. This paper revisits the NHANES data to provide these estimates, avoiding other types of interpolations that could misrepresent the population data.
- 1 February 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 157 (2) , 940-946
Hearing threshold quartiles from the 1999–2006 National Health and Nutrition Examination Surveys
This report extends the development of normative standards for estimating occupational hearing loss using data from the United States National Health and Nutrition Examination Survey (NHANES) conducted by the National Center for Health Statistics. A proposed revision of the International Organization for Standardization (ISO) 1999:2013 standard (“Acoustics—Estimation on noise-induced hearing loss”) uses a linear interpolation of hearing threshold data to estimate the 25th and 75th percentiles for men and women at 500, 1000, 2000, 3000, 4000, 6000, and 8000 Hz. This paper revisits the NHANES data to provide these estimates, avoiding other types of interpolations that could misrepresent the population data.
- Open Access
- 1 October 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 156 (4_Suppleme) , A41
Noise control at the receiver: Promoting hearing conservation in society
Noise Control Engineering traditionally employs a Source/Path/Receiver model to mitigate the generation of noise in all sorts of activities. The industrial hygiene hierarchy of controls seeks to eliminate noisy processes, to identify substitute processes, or to develop engineering solutions that reduce noise at the Source or along the Path. Administrative controls and personal protective equipment (PPE) are the last resort to reduce noise at the receiver, our ears. The first three decades of my career were as an officer of the Commissioned Corps of the United States Public Health Service and I was assigned to the Centers for Disease Control, National Institute for Occupational Safety and Health. My research focused on developing rating and testing methods for hearing protection devices, standards to evaluate occupational noise exposures, and methods to measure impulse noise exposures. This talk will describe how I transitioned from graduate student in physics to a noise researcher focused on the protection of the receiver's ears.
- 1 October 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 156 (4_Suppleme) , A41
Open AccessNoise control at the receiver: Promoting hearing conservation in society
Noise Control Engineering traditionally employs a Source/Path/Receiver model to mitigate the generation of noise in all sorts of activities. The industrial hygiene hierarchy of controls seeks to eliminate noisy processes, to identify substitute processes, or to develop engineering solutions that reduce noise at the Source or along the Path. Administrative controls and personal protective equipment (PPE) are the last resort to reduce noise at the receiver, our ears. The first three decades of my career were as an officer of the Commissioned Corps of the United States Public Health Service and I was assigned to the Centers for Disease Control, National Institute for Occupational Safety and Health. My research focused on developing rating and testing methods for hearing protection devices, standards to evaluate occupational noise exposures, and methods to measure impulse noise exposures. This talk will describe how I transitioned from graduate student in physics to a noise researcher focused on the protection of the receiver's ears.
- Open Access
- 1 March 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 155 (3_Suppleme) , A64
Comparison of two acoustic test fixtures for measuring impulse level dependent attenuation
In the American National Standards Institute (ANSI) S12.42-2010 standard for measuring insertion loss of hearing protection devices (HPDs) in impulsive noise, the range of peak sound pressure levels for the impulses is 132 to 168 dB peak sound pressure level (dB pSPL). The specification of the acoustic test fixtures (ATFs) included an IEC 60318-4 ear simulator fitted with a microphone. The microphones typically used are a ¼” cartridge and have a dynamic range up to about 169 dB pSPL. For most small caliber firearms, the peak SPLs are less than 170 dB SPL at the location of the shooters ear (Schulz et al. 2013). For some military weapon systems that produce impulses greater than 170 dB pSPL, impulse insertion loss cannot be assessed without exceeding the microphone maximum dynamic range. Some condenser microphones have maximum dynamic ranges of 190 dB pSPL. This paper compares insertion losses for HPDs measured on two GRAS 45CB ATFs with microphones with maximum dynamic ranges of 169 and 193 dB pSPL. Waveform distortion, field probe to unoccluded transfer functions between the ATF and field probe will be examined for distortion and accuracy when estimating the impulse level dependent attenuation.
- 1 March 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 155 (3_Suppleme) , A64
Open AccessComparison of two acoustic test fixtures for measuring impulse level dependent attenuation
In the American National Standards Institute (ANSI) S12.42-2010 standard for measuring insertion loss of hearing protection devices (HPDs) in impulsive noise, the range of peak sound pressure levels for the impulses is 132 to 168 dB peak sound pressure level (dB pSPL). The specification of the acoustic test fixtures (ATFs) included an IEC 60318-4 ear simulator fitted with a microphone. The microphones typically used are a ¼” cartridge and have a dynamic range up to about 169 dB pSPL. For most small caliber firearms, the peak SPLs are less than 170 dB SPL at the location of the shooters ear (Schulz et al. 2013). For some military weapon systems that produce impulses greater than 170 dB pSPL, impulse insertion loss cannot be assessed without exceeding the microphone maximum dynamic range. Some condenser microphones have maximum dynamic ranges of 190 dB pSPL. This paper compares insertion losses for HPDs measured on two GRAS 45CB ATFs with microphones with maximum dynamic ranges of 169 and 193 dB pSPL. Waveform distortion, field probe to unoccluded transfer functions between the ATF and field probe will be examined for distortion and accuracy when estimating the impulse level dependent attenuation.
- Open Access
- 1 January 2024
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 54 (1) , 002001
Summary of “Evaluation of Hearing Protection Devices with Impulse Noise and Acoustic Test Fixtures”
This article summarizes the findings presented in a special session on the evaluation of hearing protection devices (HPDs) with impulse noise and acoustic test This article summarizes the findings presented in a special session on the evaluation of hearing protection devices (HPDs) with impulse noise and acoustic test
- 1 January 2024
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 54 (1) , 002001
Open AccessSummary of “Evaluation of Hearing Protection Devices with Impulse Noise and Acoustic Test Fixtures”
This article summarizes the findings presented in a special session on the evaluation of hearing protection devices (HPDs) with impulse noise and acoustic test This article summarizes the findings presented in a special session on the evaluation of hearing protection devices (HPDs) with impulse noise and acoustic test
- Open Access
- 1 July 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 154 (1) , R1-R2
The quest for a damage risk criterion for hazardous noise exposure
The Reflections series takes a look back on historical articles from The Journal of the Acoustical Society of America that have had a significant impact on the science and practice of acoustics.
- 1 July 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 154 (1) , R1-R2
Open AccessThe quest for a damage risk criterion for hazardous noise exposure
The Reflections series takes a look back on historical articles from The Journal of the Acoustical Society of America that have had a significant impact on the science and practice of acoustics.
- Open Access
- 1 March 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (3_suppleme) , A110
Effect of hearing protection attenuation on impulse insertion loss and kurtosis
Kurtosis (the fourth standardized moment of the sound pressure) has been used to assess the additional risk of hearing loss for complex or impulsive noise exposures. Murphy et al. [2012] reported the impulse peak insertion loss of five hearing protection devices (HPDs) for firearm impulse noise. Fackler et al. [2017] reported a spectral insertion loss for several HPDs assessed with firearm and shock tube impulse noise sources. Murphy [2019] previously reported the effect of five hearing protection devices on the kurtosis and insertion loss assessed with jackhammer noise. Unprotected Jackhammer noise exhibited kurtosis values between about 15 to 17, whereas protected exposures exhibited kurtosis between about 3 to 12. Anderson and Argo [2022] reported that insertion loss was unaffected by kurtosis level for seventeen HPDs measured on an acoustic test fixture under headphones. This paper will apply the complex transfer functions from Murphy et al. [2012] to the jackhammer noises measured by Murphy [2019]. The levels of the unoccluded noises transformed to the ear canal of the fixture will be compared to occluded jackhammer noises levels measured in the fixture.
- 1 March 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (3_suppleme) , A110
Open AccessEffect of hearing protection attenuation on impulse insertion loss and kurtosis
Kurtosis (the fourth standardized moment of the sound pressure) has been used to assess the additional risk of hearing loss for complex or impulsive noise exposures. Murphy et al. [2012] reported the impulse peak insertion loss of five hearing protection devices (HPDs) for firearm impulse noise. Fackler et al. [2017] reported a spectral insertion loss for several HPDs assessed with firearm and shock tube impulse noise sources. Murphy [2019] previously reported the effect of five hearing protection devices on the kurtosis and insertion loss assessed with jackhammer noise. Unprotected Jackhammer noise exhibited kurtosis values between about 15 to 17, whereas protected exposures exhibited kurtosis between about 3 to 12. Anderson and Argo [2022] reported that insertion loss was unaffected by kurtosis level for seventeen HPDs measured on an acoustic test fixture under headphones. This paper will apply the complex transfer functions from Murphy et al. [2012] to the jackhammer noises measured by Murphy [2019]. The levels of the unoccluded noises transformed to the ear canal of the fixture will be compared to occluded jackhammer noises levels measured in the fixture.
- Open Access
- 1 January 2023
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 54 (1) , 002005
Overcoming Barriers to Hearing Protector Fit Testing – Outcomes of the International Hearing Protector Fit-Testing Symposium
Wide adoption of hearing protector fit testing (HPFT), involves overcoming barriers to implementation. Many challenges were identified and discussed at the Inte Wide adoption of hearing protector fit testing (HPFT), involves overcoming barriers to implementation. Many challenges were identified and discussed at the Inte
- 1 January 2023
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 54 (1) , 002005
Open AccessOvercoming Barriers to Hearing Protector Fit Testing – Outcomes of the International Hearing Protector Fit-Testing Symposium
Wide adoption of hearing protector fit testing (HPFT), involves overcoming barriers to implementation. Many challenges were identified and discussed at the Inte Wide adoption of hearing protector fit testing (HPFT), involves overcoming barriers to implementation. Many challenges were identified and discussed at the Inte
- Open Access
- 1 January 2023
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 53 (1) , 002004
Novel Solutions for Hearing Protector Fit Testing – Outcomes of the International Hearing Protector Fit-Testing Symposium
Wide scale adoption of hearing protector fit testing (HPFT), involves overcoming barriers to implementation. Many challenges were identified and discussed at th Wide scale adoption of hearing protector fit testing (HPFT), involves overcoming barriers to implementation. Many challenges were identified and discussed at th
- 1 January 2023
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 53 (1) , 002004
Open AccessNovel Solutions for Hearing Protector Fit Testing – Outcomes of the International Hearing Protector Fit-Testing Symposium
Wide scale adoption of hearing protector fit testing (HPFT), involves overcoming barriers to implementation. Many challenges were identified and discussed at th Wide scale adoption of hearing protector fit testing (HPFT), involves overcoming barriers to implementation. Many challenges were identified and discussed at th
- Open Access
- 1 January 2023
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 53 (1) , 002003
Practical Implementation of Hearing Protector Fit Testing – Outcomes of the International Hearing Protector Fit-Testing Symposium
Hearing protector fit testing (HPFT) has achieved wider acceptance in civilian and military occupational hearing loss prevention programs. At the Internati Hearing protector fit testing (HPFT) has achieved wider acceptance in civilian and military occupational hearing loss prevention programs. At the Internati
- 1 January 2023
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 53 (1) , 002003
Open AccessPractical Implementation of Hearing Protector Fit Testing – Outcomes of the International Hearing Protector Fit-Testing Symposium
Hearing protector fit testing (HPFT) has achieved wider acceptance in civilian and military occupational hearing loss prevention programs. At the Internati Hearing protector fit testing (HPFT) has achieved wider acceptance in civilian and military occupational hearing loss prevention programs. At the Internati
- Open Access
- 1 January 2023
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 53 (1) , 002001
Standards and Regulations for Hearing Protector Fit Testing – Outcomes of the International Hearing Protector Fit-Testing Symposium
Knowledge about the relationship between hearing protector attenuation and hearing protector fit has evolved over the decades, as has the accessibility to Knowledge about the relationship between hearing protector attenuation and hearing protector fit has evolved over the decades, as has the accessibility to
- 1 January 2023
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 53 (1) , 002001
Open AccessStandards and Regulations for Hearing Protector Fit Testing – Outcomes of the International Hearing Protector Fit-Testing Symposium
Knowledge about the relationship between hearing protector attenuation and hearing protector fit has evolved over the decades, as has the accessibility to Knowledge about the relationship between hearing protector attenuation and hearing protector fit has evolved over the decades, as has the accessibility to