ISIgnacio Sanz‐Martin

Ignacio Sanz‐Martin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ignacio Sanz‐Martin has a total of 199 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Microbial Network Signatures Associated With Outcomes of Peri‐Implantitis Therapy

    by Seung‐Hyun Park, Da‐Mi Kim, Seulbin Im, Eduardo H. de Souza Oliveira, Ignacio Sanz‐Martin, Ignacio Sanz‐Sanchez, Jan Derks, Magda Feres, Jae‐Kook Cha

    Aim: To investigate the microbial network signatures associated with outcomes following surgical therapy of peri‐implantitis. Materials and Methods: Microbiological data from a 1‐year randomised controlled trial of 28 patients (28 implants) were analysed. Based on a composite outcome (probing depth ≤ 5 mm, minimal bleeding on probing and no further marginal bone loss) at 1 year, implant sites were categorised into a successful ( n = 10) or a non‐successful group ( n = 18). Peri‐implant crevicular fluid was collected at baseline and at 3, 6 and 12 months and analysed using 16S rRNA gene sequencing. Results: A significant compositional shift from baseline to 1 year was observed in the successful group ( p = 0.001), with a significant increase in Rothia aeria ( p = 0.048), Haemophilus parainfluenzae ( p = 0.033) and Neisseria oralis ( p = 0.025) over time. Network analysis revealed that the successful group exhibited a Porphyromonas gingivalis ‐associated module enriched with high‐centrality commensals at baseline, and significantly greater network edge density ( p = 0.005) and connectivity ( p = 0.018) at 1 year. Spearman correlation analyses at 1 year identified significant negative correlations between P. gingivalis and commensals including H. parainfluenzae , Streptococcus species and Veillonella undefined ( p < 0.05). Conclusion: In this exploratory secondary analysis of a small cohort, favourable outcomes of peri‐implantitis therapy were associated with increased microbial network connectivity and commensal centrality. Trial Registration: Korean Clinical Research Information Service number KCT0007900

  • Open Access

    Peri‐Implant Soft Tissue Phenotype Remodeling Following Peri‐Implantitis Surgery: A Prospective Profilometric Analysis

    by Hee‐Sun Choi, Seung‐Hyun Park, Seulbin Im, Da‐Mi Kim, Eun‐Kyoung Pang, Ignacio Sanz‐Martin, Jae‐Kook Cha

    Aim: To characterize longitudinal changes in peri‐implant soft tissue phenotype following surgical therapy of peri‐implantitis. Materials and Methods: Twenty‐one patients with superimposable intraoral scan datasets at four timepoints—pre‐operative (T0), intra‐operative (T1), 3‐month (T2), and 12‐month (T3) follow‐up—were included. Soft tissue parameters including mean mucosal thickness (mMT), supracrestal tissue height (STH), keratinized mucosal area, and volumetric shrinkage were assessed. Clinical parameters, including probing pocket depth (PPD), bleeding on probing (BOP), plaque index (PI), and gingival index (GI), were recorded at T0, T2, and T3. Treatment success was defined using composite clinical criteria at 12 months. Results: Significant reductions in mMT, STH, and keratinized mucosal area were observed over 12 months in both successful and non‐successful treatment groups. mMT decreased from 1.45 mm to 0.36 mm in the successful group and from 2.83 mm to 1.38 mm in the non‐successful group. STH converged to approximately 3 mm in both groups at T3. Keratinized mucosal area also decreased over time, with no significant between‐group difference ( p = 0.721). The most pronounced changes occurred during the first 3 months, with volumetric shrinkage of 30.2 and 31.6 mm 3 at T2 in the successful and non‐successful groups, respectively ( p < 0.001). The magnitude of soft tissue phenotype changes did not differ significantly between groups for most parameters ( p = 0.522). STH at T3 showed a negative association with BOP (coefficient = −0.08, p = 0.049), whereas baseline keratinized mucosal area positively predicted residual mMT at T3 (coefficient = 0.024, p < 0.001). Conclusions: Surgical therapy of peri‐implantitis resulted in significant reductions of soft tissue phenotype, and baseline keratinized mucosal area was positively associated with residual mMT at 12 months. No statistically significant association was observed between the magnitude of soft tissue shrinkage and clinical outcomes.


  • Open Access

    Peri‐Implant Soft Tissue Deformities in the Anterior Maxilla: A Cross‐Sectional Study

    by Emilio Couso‐Queiruga, Matteo Leoncini, Sophia E. Vollath, Gustavo Avila‐Ortiz, Ignacio Sanz‐Martin, Vivianne Chappuis, Manrique Fonseca, Clemens Raabe

    Background: This study aimed to evaluate the prevalence of peri‐implant soft tissue deformities, including dehiscences (PSTDs) and deficiencies, around bone‐level (BL) and tissue‐level (TL) implants in the anterior maxilla, assess associated variables, and patient‐reported outcomes (PROs). Methods: Adults with implant‐supported prostheses (ISPs) in the anterior maxilla were recruited. Clinical and digital assessments were performed, and related variables were analyzed. Results: A total of 205 ISPs in 193 patients were evaluated. Mean follow‐up after implant placement was 11.3 ± 1.4 years. PSTD prevalence was comparable between BL and TL implants (88.8% vs. 94.4%; p = 0.19), or when PSTD ≥ 1 mm (23.9% vs. 22.5%; p = 0.97). Similarly, 99.25% and 100% of BL and TL showed deformities, p = 1.00. Prevalence of prosthetic interface/abutment (12.7% vs. 2.5%) and implant shoulder exposure (4.2% vs. 0%), and overcontoured ISP (35.2% vs. 12.7%) was significantly higher in TL implants ( p < 0.01). Greater papilla dimensions and lower volume deficiency (90.3% vs. 98.6%; p < 0.01) were observed around BL implants, while mucosal discoloration was similar between groups (16.4% vs. 15.5%; p > 0.05). Greater PSTD depth was associated with older age, reduced keratinized mucosa width (< 2 mm), wider implant diameter, prosthetic overcontouring, lower mucosal volume, and papilla deficiencies ( p < 0.05). Wider prosthetic emergence angles were associated with reduced papilla dimensions ( p < 0.05). Thin mucosa (< 2 mm) was associated with grayish mucosal discoloration (OR = 2.79). Despite these findings, OHIP‐14 scores were low, and PROs were high, with no significant differences between groups. Conclusions: Prevalence of peri‐implant soft tissue deformities in the anterior maxilla is high irrespective of implant type and is associated with age, soft tissue phenotype, mucosal volume, papilla deficiencies, wider implant diameters, and prosthetic overcontouring. However, this does not seem to have a measurable impact on patient perception.


  • Influence of Surgical and Prosthetic Factors on Peri‐Implant Health or Disease. Clinical Recommendations From a Spanish Society of Periodontology ( SEPA ) Expert Consensus

    by Beatriz de Tapia, Alberto Monje, Guillermo Pradíes, Ramon Pons, Irene García, Ignacio Sanz‐Martín, Ana Carrillo de Albornoz, Ferran Puigrefagut, Iria López, Javier Pérez, et al.

    Objective: To examine which prosthetic factors, including design, materials, and cleansability, may influence the onset of peri‐implant diseases. Materials and Methods: The Spanish Society of Periodontology (SEPA) convened a group of experienced periodontists, prosthodontists, and laboratory technicians to develop clinical recommendations based on expert consensus. Results: Emerging evidence highlights the importance of prosthetic design, implant positioning, and material selection in mitigating biological complications. Notably, access for self‐performed oral hygiene is a significant predictor of peri‐implant health, and designs that facilitate cleaning and prosthetic configurations that minimize plaque accumulation are favored. Additionally, the use of less porous materials, such as zirconia, has been shown to improve soft tissue integration and plaque control. Other critical considerations include minimizing prosthetic manipulation and ensuring optimal implant‐abutment connections to prevent bone loss. Conclusions: This review presents clinical recommendations on prosthetic design, material selection, and implant placement in order to reduce the risk of peri‐implant diseases. Future research should focus on refining these strategies and evaluating the long‐term effectiveness of digital manufacturing techniques in improving prosthetic accuracy and reducing the incidence of disease. Clinical Significance: Peri‐implant diseases, including peri‐implantitis, are major concerns in implant dentistry, often linked to suboptimal prosthetic designs and maintenance. This review underscores the importance of prosthetic design in preventing such diseases. Clinicians should prioritize prosthetic configurations that enhance accessibility for self‐performed oral hygiene. Furthermore, proper implant positioning in a 3D prosthetically driven position is essential for preventing peri‐implant complications. Additionally, the choice of materials, such as ceramic‐based and zirconia prostheses, can influence plaque accumulation and soft tissue health. Regular follow‐ups and patient education on maintaining good oral hygiene are critical for the prevention of peri‐implant diseases. Finally, the increasing use of digital technologies in implant placement and prosthesis manufacturing offers the potential for improving accuracy and minimizing prosthetic misfits, which may further reduce the risk of disease. Future research is needed to explore the impact of digital tools on peri‐implant health and to refine best practices in prosthetic design and material selection.


  • Open Access

    Changes in Peri‐Implant Soft Tissue Dimensions Following Soft Tissue Contour Augmentation: A 3‐Year Follow‐Up of a Multi‐Center RCT

    by Karin Jepsen, Søren Jepsen, Christoph H. F. Hämmerle, Leonardo Mancini, Franz J. Strauss, Malin Strasding, Stefan Hicklin, Mariano Sanz, Ignacio Sanz‐Martin, Daniel S. Thoma, et al.

    Aim: To assess 3‐year changes of peri‐implant tissues following previous soft tissue (volume) augmentation (STA) with a volume‐stable collagen matrix (VCMX) or connective tissue (SCTG) at single‐implant restorations. Material and Methods: In a non‐interventional follow‐up observation, peri‐implant tissues were evaluated with regard to buccal mucosal thickness (MT) and contour, peri‐implant conditions: probing depth (PD), bleeding on probing (BOP), plaque (PI), mucosal margin level/crown height (CH), and clinician‐reported esthetics (PE and PES). Patient‐ and clinician‐reported satisfaction was recorded at 3 years (VAS). Mixed‐effects models were used to compare the groups. Results: Fifty‐six patients (age: 48.0 ± 15.5 years) were followed. MT changes over time did not differ between groups [3.9 ± 1.4 mm to 2.6 ± 1.1 mm for VCMX; 3.8 ± 1.3 mm to 2.9 ± 1.2 mm for SCTG]. The estimated intergroup mean difference (VCMX–SCTG) was 0.2 mm ( p = 0.587). Mucosal recession was minimal in both groups [0.2 ± 1.0 mm (VCMX) and 0.2 ± 0.6 mm (SCTG)]. At 3 years, intergroup differences in PE scores amounted to 0.5 at mesial ( p = 0.06) and distal sites ( p = 0.023) in favor of SCTG. PES scores were high in both groups (VCMX = 10.8; SCTG = 10.9) with no significant differences between the groups ( p = 0.580). Patient‐reported satisfaction with overall esthetics was high (VAS: SCTG = 9.5; VCMX = 9.6) with no significant intergroup differences. Clinician‐reported satisfaction was significantly higher for SCTG (VAS: 8.5) compared with VCMX (VAS: 7.4; p = 0.04). Conclusion: Both VCMX and SCTG maintained stable peri‐implant soft tissues with minimal contour changes 3 years after implant loading. Clinician‐reported outcome—esthetics overall—favored SCTG; however, patient‐reported outcomes did not support this finding.


  • Open Access

    Implantoplasty vs. Rotating Titanium Brushes in the Surgical Treatment of Peri‐Implantitis: A 1‐Year Randomised Controlled Clinical Trial

    by Seung‐Hyun Park, Dong‐Beom Kim, Da‐Mi Kim, Ignacio Sanz‐Martin, Ignacio Sanz‐Sanchez, Jan Derks, Jae‐Kook Cha

    Aim: To evaluate treatment outcomes following implantoplasty or the use of rotating titanium brushes in the surgical therapy of peri‐implantitis. Materials and Methods: Thirty patients with peri‐implantitis in need of surgical treatment were enrolled in a 12‐month randomised clinical trial with a non‐inferiority set‐up. Surface decontamination was performed using either titanium brushes (test group) or implantoplasty (control group). Clinical and radiographic parameters as well as patient‐reported outcomes (Oral Health Impact Profile‐14; OHIP‐14) were evaluated. Results: At 12 months, the composite outcome was achieved in 6/15 implants in the test group and in 4/15 in the control group. Probing pocket depth (PPD) values decreased by 3.6 ± 1.5 mm (test) and 3.3 ± 1.2 mm (control), demonstrating non‐inferiority of the test procedure. Additional bone loss was observed in the control group (0.7 ± 1.2 mm), while bone levels remained unchanged in the test group (0.0 ± 0.6 mm). Baseline PPD ( p = 0.044) and the presence of an adjacent implant affected by peri‐implantitis ( p = 0.033) were relevant factors for pocket closure (PPD ≤ 5 mm at 12 months). Time for surface decontamination was significantly less in the test (3 min 1 s) when compared to the control group (5 min 27 s) ( p = 0.006). OHIP‐14 scores were statistically indifferent. Conclusion: Both groups showed favourable outcomes, demonstrating non‐inferiority of titanium brushes to implantoplasty. Trial Registration: The trial was registered with the Clinical Research Information Service of the National Research Institute of Health (South Korea), no. KCT007900. ( https://cris.nih.go.kr/cris/search/detailSearch.do?seq=23346&search_page=L )


  • Open Access

    Clinical Trends in the Prevention of Peri‐Implantitis: Spanish Society of Periodontology ( SEPA) Foundation Survey Using the Delphi Method

    by Alberto Monje, Ana Molina, Olalla Argibay, Beatriz de Tapia, Jan Derks, Elena Figuero, Adrián Guerrero, Fernando Luengo, Eduardo Montero, Ignacio Sanz‐Martín, et al.

    Objective: To assess clinical trends to prevent peri‐implantitis in applying a two‐step survey based on the Delphi method. Material and Methods: A panel of participants aged < 45 years old selected by the Spanish Society of Periodontology (SEPA) was asked to answer a survey with 75 statements prepared by a steering committee. Items were divided into 5 major areas: etiopathogenesis and epidemiology, surgical, implant, and prosthetic‐related factors on the onset/progression of peri‐implantitis, and self‐ and professional‐administered oral hygiene. Degree of agreement or disagreement among participants was reported. Results: In total, 44 participants responded favorably to participate in the survey. From the 75 statements formulated, 35 were agreed on in a first round (46.7%). From the 40 statements that did not reach consensus, 16 were agreed on in a second round (40.0%). Overall, 51 out of 75 statements (68.0%) achieved consensus in a second round. From these, 36 (48.0%) were in agreement, while 15 (20.0%) were in disagreement. The sections that explored surgical‐related factors and prosthesis‐related factors of peri‐implantitis yielded the highest level of conflict (9/18 and 8/14 statements demonstrated indeterminate agreement, respectively). In the sections on the etiopathogenesis and epidemiology of peri‐implantitis and implant‐related factors, most items reached consensus (14/17 and 10/13 items, respectively). The section on self‐ and professional‐administered oral hygiene obtained the highest level of consensus, with only 1/13 items showing dissent among the participants. Conclusion: The results of this study on the clinical trends in the prevention of peri‐implantitis showed consensus agreement for ∼70% of the statements evaluated.


  • Top Cited Papers
    Open Access

    Aesthetics and Patient‐Reported Outcomes in Periodontology and Implant Dentistry: Consensus Report

    by Maurizio Tonetti, Mariano Sanz, Francesco Cairo, Jose Nart, Iain Chapple, Mario Aimetti, Sofia Aroca, Gustavo Avila‐Ortiz, Juan Blanco, Antonio Bujaldón, et al.

    Background: Aesthetics and patient‐reported experiences (PREs) and outcomes (PROs) influence treatment choices, but have been largely overlooked in periodontology and implant dentistry. This consensus conference evaluated these factors by focusing on gingival recession defects (GRDs), immediate or early/delayed implant placement and peri‐implant buccal soft‐tissue dehiscences.Methods: The workshop discussions were informed by five specifically commissioned systematic reviews covering PREs, PROs and clinician‐reported outcomes (CROs), including effectiveness, aesthetics and other concerns.Results: Following treatments such as coronally advanced flaps (CAFs) with a connective tissue graft (CTG) for root coverage (RC), a positive correlation was noted between clinician‐reported aesthetic scores and RC measures for GRDs. However, a corresponding correlation for patient‐reported aesthetic perceptions was not evident. In dental implant procedures, the addition of a CTG immediately after implant placement significantly mitigated the apical shift in the mid‐facial mucosal level. However, clinician‐ and patient‐reported aesthetic scores were not reflective of these changes. Neither set of scores captured the impact of grafting on improving peri‐implant soft‐tissue volume. In the treatment of peri‐implant dehiscences, soft‐tissue augmentation (STA), using CTG beneath CAF, resulted in favourable outcomes in clinician‐ and patient‐perceived aesthetics.Conclusions: Clinician and patient views provide complementary perspectives for evidence‐based clinical decision making. They need to be integrated into select interventions. Specific trials are needed encompassing PREs, PROs and CROs and reporting benefits and harms.


  • Open Access

    Efficacy of the application of leukocyte and platelet‐rich fibrin (L‐PRF) on alveolar ridge preservation. A randomized controlled clinical trial

    by Carolina Encalada Abad, Ignacio Sanz‐Sanchez, Victor Serrano, Javier Sanz Esporrin, Ignacio Sanz‐Martin, Mariano Sanz

    Introduction: Alveolar ridge preservation (ARP) is a well‐defined treatment performed to reduce bone dimensional changes occurring during the healing of post‐extraction sockets to allow for adequate implant placement. Leukocyte and platelet‐rich fibrin (L‐PRF) has been showing to potentially promote bone and tissue regeneration during wound healing. Therefore, the aim of this study is to evaluate its efficacy for ARP when applied to fresh extraction sockets, in comparison with spontaneous healing.Materials and Methods: Twenty‐seven patients with hopeless non‐molar teeth were treated. After randomization, fresh extraction sockets were either filled with L‐PRF or allowed to heal spontaneously. CBCTs and intraoral scans were obtained immediately after extraction and at 4 months. Through superimposition of the obtained images, changes in the horizontal ridge width, height, buccal volume, and ridge contour changes were measured, as well as patient‐reported outcome measures (PROM's).Results: The ridge dimensions changed similarly in both groups. Although less reduction occurred in the test group at 1 mm from the bone crest, differences were not statistically significant (p > 0.05). Application of L‐PRF did not prevent reductions of ridge contours, neither in the linear vertical aspect nor in volumetric changes. There were no differences between groups in the need for bone regeneration when placing implants. Patients in both groups reported similar outcomes in terms of bleeding, pain, inflammation, and function at 1 and 4 weeks postoperatively.Conclusion: Alveolar preservation with L‐PRF neither minimized bone resorption occurring after tooth extraction in non‐molar sites nor reduced the need for bone regeneration when placing implants. Furthermore, its use did not improve PROM's.


  • Open Access

    In vitro effect of different implant decontamination methods in three intraosseous defect configurations

    by Fernando Luengo, Javier Sanz‐Esporrín, Fernando Noguerol, Ignacio Sanz‐Martín, Ignacio Sanz‐Sánchez, Mariano Sanz

    Objectives: This in vitro investigation was aimed to evaluate the cleaning ability of four mechanical devices designed for decontaminating implant surfaces.Material and methods: Ninety‐six implants were coated with permanent ink and inserted into 3D‐printed resin blocks simulating three different intraosseous defect configurations (types Ib, Ic, and Ie). The four tested mechanical decontamination devices (air‐polishing with glycine powder, rotating titanium brush, polyetheretherketone [PEEK]‐coated ultrasonic tip, and stainless steel ultrasonic tip) were randomly applied onto the 5 mm exposed implant surface. Standardized photographs were taken from a frontal perspective and with a 30° angle coronally and apically to the implant axis. The area with remnant ink on the implant surface was calculated.Results: Although none of the groups achieved complete ink removal, air‐polishing with glycine and titanium brushes demonstrated a higher cleaning ability when compared with ultrasonic devices either with standard or PEEK tips for all three defect configurations. For the three tested models, the best cleaning ability in all groups was shown on implant surfaces without facing an intraosseous wall. Titanium brush was the most effective when the intraosseous walls existed. Cleaning effectiveness diminished in the threads located in the apical third, especially when using air‐polishing and ultrasonic devices.Conclusions: Titanium brushes and air‐polishing devices were more effective in removing artificial biofilm using this in vitro model, although their effectiveness was influenced by the presence of the intrabony component.