NMNobuhiro Matsumoto

Nobuhiro Matsumoto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nobuhiro Matsumoto has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Nobuyuki Aoki

    Integrated Research Center for Nature Positive Technology, National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki 305-8567, Japan

    7 shared publications
  • Shigeyuki Ishidoya

    National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8569, Japan

    7 shared publications
  • Kenji Kato

    National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan

    6 shared publications
  • Takuya Shimosaka

    National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, 305-8563, Japan

    6 shared publications
  • Takuro Watanabe

    National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST)

    4 shared publications
  • Shohei Murayama

    Environmental Management Research Institute, National Institute of Advanced Industrial Science and Technology (EMRI/AIST), Tsukuba 305-8569, Japan

    3 shared publications

Latest Publications

  • Open Access

    Comment on egusphere-2026-4405

    by Nobuyuki Aoki, Shigeyuki Ishidoya, Nobuhiro Matsumoto

    Accurate determination of atmospheric Ar/N2 ratios requires primary standard gases with well-characterized uncertainties. However, an initial preparation approach based on the transfer of premixed gases introduced systematic deviations caused by transfer-induced composition changes, which limited the achievable accuracy. In this study, we developed an improved gravimetric preparation method for highly precise Ar standards (HPAs), in which CO2, Ar, O2, and N2 are introduced independently from source gases. This approach eliminates transfer-induced compositional changes and allows the Ar amount to be determined directly with high precision. The resulting uncertainty in Ar/N2 was reduced to approximately 5 per meg, corresponding to an Ar molar fraction of 0.05 µmol mol−1. Validation confirmed that the gravimetric and measured values for CO2, O2/N2, and Ar/N2 agreed within their uncertainties. Using the validated HPAs, the absolute Ar/N2 ratio of the AIST reference air was redetermined as 0.01195567 ± 0.000000011, a 8-fold reduction in uncertainty relative to the previous value. Application to atmospheric observations yielded an absolute Ar/N2 ratio of 0.01195497 ± 0.00000013 and an Ar mole fraction of 9335.71 ± 0.10 µmol mol−1 in 2021. The numbers following the symbol ± represent the standard uncertainty. These results establish a metrologically traceable framework for high-precision atmospheric Ar measurements.

  • Open Access

    Comment on egusphere-2026-4405

    by Nobuyuki Aoki, Shigeyuki Ishidoya, Nobuhiro Matsumoto

    Accurate determination of atmospheric Ar/N2 ratios requires primary standard gases with well-characterized uncertainties. However, an initial preparation approach based on the transfer of premixed gases introduced systematic deviations caused by transfer-induced composition changes, which limited the achievable accuracy. In this study, we developed an improved gravimetric preparation method for highly precise Ar standards (HPAs), in which CO2, Ar, O2, and N2 are introduced independently from source gases. This approach eliminates transfer-induced compositional changes and allows the Ar amount to be determined directly with high precision. The resulting uncertainty in Ar/N2 was reduced to approximately 5 per meg, corresponding to an Ar molar fraction of 0.05 µmol mol−1. Validation confirmed that the gravimetric and measured values for CO2, O2/N2, and Ar/N2 agreed within their uncertainties. Using the validated HPAs, the absolute Ar/N2 ratio of the AIST reference air was redetermined as 0.01195567 ± 0.000000011, a 8-fold reduction in uncertainty relative to the previous value. Application to atmospheric observations yielded an absolute Ar/N2 ratio of 0.01195497 ± 0.00000013 and an Ar mole fraction of 9335.71 ± 0.10 µmol mol−1 in 2021. The numbers following the symbol ± represent the standard uncertainty. These results establish a metrologically traceable framework for high-precision atmospheric Ar measurements.

  • Open Access

    High-precision gravimetric primary standards for atmospheric Ar/N 2 measurements and redetermination of atmospheric Ar abundance

    by Nobuyuki Aoki, Shigeyuki Ishidoya, Nobuhiro Matsumoto

    Accurate determination of atmospheric Ar/N2 ratios requires primary standard gases with well-characterized uncertainties. However, an initial preparation approach based on the transfer of premixed gases introduced systematic deviations caused by transfer-induced composition changes, which limited the achievable accuracy. In this study, we developed an improved gravimetric preparation method for highly precise Ar standards (HPAs), in which CO2, Ar, O2, and N2 are introduced independently from source gases. This approach eliminates transfer-induced compositional changes and allows the Ar amount to be determined directly with high precision. The resulting uncertainty in Ar/N2 was reduced to approximately 5 per meg, corresponding to an Ar molar fraction of 0.05 µmol mol−1. Validation confirmed that the gravimetric and measured values for CO2, O2/N2, and Ar/N2 agreed within their uncertainties. Using the validated HPAs, the absolute Ar/N2 ratio of the AIST reference air was redetermined as 0.01195567 ± 0.000000011, a 8-fold reduction in uncertainty relative to the previous value. Application to atmospheric observations yielded an absolute Ar/N2 ratio of 0.01195497 ± 0.00000013 and an Ar mole fraction of 9335.71 ± 0.10 µmol mol−1 in 2021. The numbers following the symbol ± represent the standard uncertainty. These results establish a metrologically traceable framework for high-precision atmospheric Ar measurements.

  • Investigation to replace the triple point of Hg in the ITS-90

    by Yasuki Kawamura, Nobuhiro Matsumoto, Tohru Nakano

    The triple points of sulfur hexafluoride (TPSF6), carbon dioxide (TPCO2) and xenon (TPXe) have possibility as candidates for replacing the triple point of mercu The triple points of sulfur hexafluoride (TPSF6), carbon dioxide (TPCO2) and xenon (TPXe) have possibility as candidates for replacing the triple point of mercu

  • Open Access

    Influence of CO 2 adsorption on cylinders and fractionation of CO 2 and air during the preparation of a standard mixture

    by Nobuyuki Aoki, Shigeyuki Ishidoya, Shohei Murayama, Nobuhiro Matsumoto

    We evaluated carbon dioxide (CO2) adsorption on the internal surface of the cylinder and the fractionation of CO2 and air during the preparation of standard mixtures with atmospheric CO2 level through multistep dilution. The CO2 molar fractions in the standard mixtures deviated from the gravimetric values by -0.207±0.060 µmol mol−1 on average, which is larger than the compatibility goal (0.1 µmol mol−1) recommended by the World Meteorological Organization. The deviation was consistent with those calculated using two fractionation factors: one was estimated by the mother–daughter transfer experiment in which CO2–air mixtures were transferred from a mother cylinder to an evacuated daughter cylinder, and another was computed by applying the Rayleigh model to the change in CO2 molar fractions in a source gas as its pressure was depleted from 11.5 to 1.1 MPa. The mother–daughter transfer experiments showed that the deviation was caused by the fractionation of CO2 and air during the transfer of the source gas (CO2–air mixture with a higher CO2 molar fraction than that in the prepared gas mixture). The CO2 fractionation was less significant when the transfer speed decreased to less than 3 L min−1, indicating that thermal diffusion mainly caused the fractionation. The CO2 adsorption on the internal cylinder surface was experimentally evaluated by emitting a CO2–air mixture from a cylinder. When the cylinder pressure was reduced from 11.0 to 0.1 MPa, the CO2 molar fractions in the mixture exiting the cylinder increased by 0.16±0.04 µmol mol−1. By applying the Langmuir adsorption–desorption model to the measured data, the amount of CO2 adsorbed on the internal surfaces of a 10 L aluminum cylinder when preparing a standard mixture with atmospheric CO2 level was estimated to be 0.027±0.004 µmol mol−1 at 11.0 MPa.


  • Absolute Quantification of Pure Free Radical Reagents by Combination of the Effective Magnetic Moment Method and Quantitative Electron Paramagnetic Resonance Method

    by Nobuhiro Matsumoto, Nobuyasu Itoh, Kazuhiko Yamasaki

    An absolute quantitative analysis of free radicals by combining the effective magnetic moment method and the quantitative electron paramagnetic resonance [qEPR] method is proposed. This combined method utilizes the advantages of both the analytical methods and compensates for their disadvantages. In the effective magnetic moment method, the magnetic moment under a constant magnetic field is measured accurately using a superconducting quantum interference device. The qEPR method compares a "primary standard sample" and "secondary standard sample". The effective magnetic moment method was used to determine the purity of the primary standard sample. The qEPR method realizes a simple purity analysis of free-radical reagents with traceability to the International System of Units (SI). The purity of the free radicals by the qEPR method for pure 4-hydroxy-2,2,6,6-tetramethylpiperidine 1-oxyl benzoate [4HTB], 1-oxyl-2,2,6,6-tetramethyl-4-hydroxypiperidine [TEMPOL], and di(phenyl)-(2,4,6-trinitrophenyl)iminoazanium [DPPH] reagents was obtained with a relative expanded uncertainty of 0.7% for 4HTB to 1.5% for the DPPH. These small uncertainties were almost equal to those of the purity of the primary standard samples and were achieved by adopting in-plane positioning of the measured sample perpendicular to the cylindrical axis of the sample space of the superconducting quantum interference device. Some purity values of the free radicals for these reagents differed from those stated by the manufacturers. This combined method enables short-time quality control of pure radical reagents, instead of quality control by separation analytical methods or titrations.


  • Open Access

    Influence of adsorption of CO 2 on cylinder and fractionation of CO 2 and air during preparation of a standard mixture

    by Nobuyuki Aoki, Shigeyuki Ishidoya, Shohei Murayama, Nobuhiro Matsumoto

    We conducted a study to fully understand carbon dioxide (CO2) adsorption to a cylinder’s internal surface and fractionation of CO2 and air during the preparation of standard mixtures of atmospheric CO2 levels through a multistep dilution. The CO2 molar fractions in standard mixtures prepared by diluting pure CO2 with air three times deviated by −0.207 ± 0.060 μmol mol−1 on average from the gravimetric values which were calculated from masses of source materials by evaluating their CO2 molar fractions based on standard mixtures by diluting the pure CO2 with the air only once. It indicates that the deviation is larger than a compatibility goal of 0.1 μmol mol−1, which has been recommended by the World Meteorological Organization (WMO). The deviations were consistent with those calculated from the fractionation factors of 0.99968 ± 0.00010 and 0.99975 ± 0.00004 estimated in mother–daughter transfer experiment that transfer CO2/Air mixtures from a cylinder to another evacuated receiving cylinder and by applying the Rayleigh model to the increase in CO2 molar fractions in source gas as pressure depleted from 11.5 MPa to 1.1 MPa. Both fractionation factors also agree within their uncertainties. Additionally, the mother–daughter transfer experiments showed that the deviation was caused by the fractionation of CO2 and air in the process of transferring a source gas (a CO2/Air mixture with a higher CO2 molar fraction than that in the prepared gas mixture). The fact that the CO2 molar fraction weakened significantly as the transfer speed decreased suggested that the main factor of the fractionation could be thermal diffusion. However, experiments exiting a CO2 in air mixture (CO2/Air mixture) from a cylinder were conducted to evaluate the CO2 adsorption to the internal surface of the cylinder. As the cylinder pressure was reduced from 11.0 to 0.1 MPa, the CO2 molar fractions in the mixture flow leaving from the cylinder increased the CO2 molar fractions by 0.16 ± 0.04 μmol mol−1. By applying the Langmuir adsorption-desorption model to the measured data, the amount of CO2 adsorbed on the internal surfaces of a 10 L aluminum cylinder when preparing a standard mixture with atmospheric CO2 level was estimated to be 0.027 ± 0.004 μmol mol−1 at 11.0 MPa.

  • Sample Length Dependence of Magnetic Moment Detected by a SQUID Magnetometer Using Nickel Cylinders

    by Nobuhiro Matsumoto, Cindi L. Dennis, Robert D. Shull

    We report here on sample length dependence measurements in a second-order gradiometer superconducting quantum interference device (SQUID) magnetometer of pure nickel (Ni) cylinders, having a diameter of 1 mm and length of 1 mm to 7 mm. The measured magnetic moment per unit mass significantly decreases with the sample length of the Ni cylinder, when a magnetic field of 7 T was applied parallel to the long axis of the cylinder. As an example, the magnetic moment per unit mass for the 5 mm Ni cylinder is between 97 % and 94% of that for the 1 mm Ni cylinder, the number depending on the specific type of magnetometer used. The magnitude of decrease also depends on the length of the second-order gradiometer superconducting coil which differs with different models of SQUID magnetometers.