Jeffrey Free
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jeffrey Free has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Carmen Seller Oria
Department of Radiation Oncology University Medical Center Groningen University of Groningen Groningen The Netherlands
2 shared publications - Christian Richter
Oncoray – National Center For Radiation Research In Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Technology, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany
2 shared publications Christina V. Dahlgren
The Skandion Clinic, Uppsala, Sweden
2 shared publications- Johannes Albertus Langendijk
Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
2 shared publications - Ludovic De Marzi
Institut Curie, PSL Research University, University Paris Saclay, IRIS UMR9029/U1353, Campus universitaire
2 shared publications - Patrick Wohlfahrt
Siemens Healthineers, Varian, Cancer Therapy Imaging, Forchheim, Germany
2 shared publications
Latest Publications
- Open Access
- 21 October 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (21) , 21NT02
Optimizing calibration settings for accurate water equivalent path length assessment using flat panel proton radiography
Objective: Proton range uncertainties can compromise the effectiveness of proton therapy treatments. Water equivalent path length (WEPL) assessment by flat panel detector proton radiography (FP-PR) can provide means of range uncertainty detection. Since WEPL accuracy intrinsically relies on the FP-PR calibration parameters, the purpose of this study is to establish an optimal calibration procedure that ensures high accuracy of WEPL measurements. To that end, several calibration settings were investigated. Approach: FP-PR calibration datasets were obtained simulating PR fields with different proton energies, directed towards water-equivalent material slabs of increasing thickness. The parameters investigated were the spacing between energy layers (Δ E ) and the increment in thickness of the water-equivalent material slabs (Δ X ) used for calibration. 30 calibrations were simulated, as a result of combining Δ E = 9, 7, 5, 3, 1 MeV and Δ X = 10, 8, 5, 3, 2, 1 mm. FP-PRs through a CIRS electron density phantom were simulated, and WEPL images corresponding to each calibration were obtained. Ground truth WEPL values were provided by range probing multi-layer ionization chamber simulations on each insert of the phantom. Relative WEPL errors between FP-PR simulations and ground truth were calculated for each insert. Mean relative WEPL errors and standard deviations across all inserts were computed for WEPL images obtained with each calibration. Main results: Large mean and standard deviations were found in WEPL images obtained with large Δ E values (Δ E = 9 or 7 MeV), for any Δ X . WEPL images obtained with Δ E ≤ 5 MeV and Δ X ≤ 5 mm resulted in a WEPL accuracy with mean values within ±0.5% and standard deviations around 1%. Significance: An optimal FP calibration in the framework of this study was established, characterized by 3 MeV ≤ Δ E ≤ 5 MeV and 2 mm ≤ Δ X ≤ 5 mm. Within these boundaries, highly accurate WEPL acquisitions using FP-PR are feasible and practical, holding the potential to assist future online range verification quality control procedures.
- 21 October 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (21) , 21NT02
Open AccessOptimizing calibration settings for accurate water equivalent path length assessment using flat panel proton radiography
Objective: Proton range uncertainties can compromise the effectiveness of proton therapy treatments. Water equivalent path length (WEPL) assessment by flat panel detector proton radiography (FP-PR) can provide means of range uncertainty detection. Since WEPL accuracy intrinsically relies on the FP-PR calibration parameters, the purpose of this study is to establish an optimal calibration procedure that ensures high accuracy of WEPL measurements. To that end, several calibration settings were investigated. Approach: FP-PR calibration datasets were obtained simulating PR fields with different proton energies, directed towards water-equivalent material slabs of increasing thickness. The parameters investigated were the spacing between energy layers (Δ E ) and the increment in thickness of the water-equivalent material slabs (Δ X ) used for calibration. 30 calibrations were simulated, as a result of combining Δ E = 9, 7, 5, 3, 1 MeV and Δ X = 10, 8, 5, 3, 2, 1 mm. FP-PRs through a CIRS electron density phantom were simulated, and WEPL images corresponding to each calibration were obtained. Ground truth WEPL values were provided by range probing multi-layer ionization chamber simulations on each insert of the phantom. Relative WEPL errors between FP-PR simulations and ground truth were calculated for each insert. Mean relative WEPL errors and standard deviations across all inserts were computed for WEPL images obtained with each calibration. Main results: Large mean and standard deviations were found in WEPL images obtained with large Δ E values (Δ E = 9 or 7 MeV), for any Δ X . WEPL images obtained with Δ E ≤ 5 MeV and Δ X ≤ 5 mm resulted in a WEPL accuracy with mean values within ±0.5% and standard deviations around 1%. Significance: An optimal FP calibration in the framework of this study was established, characterized by 3 MeV ≤ Δ E ≤ 5 MeV and 2 mm ≤ Δ X ≤ 5 mm. Within these boundaries, highly accurate WEPL acquisitions using FP-PR are feasible and practical, holding the potential to assist future online range verification quality control procedures.
- Open Access
- 1 October 2021
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 163, 7-13
Experimental assessment of inter-centre variation in stopping-power and range prediction in particle therapy
- 1 October 2021
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 163, 7-13
Open AccessExperimental assessment of inter-centre variation in stopping-power and range prediction in particle therapy
- Open Access
- 31 July 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (15) , 155014
Assessment of range uncertainty in lung-like tissue using a porcine lung phantom and proton radiography
Thoracic tumours are increasingly considered indications for pencil beam scanned proton therapy (PBS-PT) treatments. Conservative robustness settings have been suggested due to potential range straggling effects caused by the lung micro-structure. Using proton radiography (PR) and a 4D porcine lung phantom, we experimentally assess range errors to be considered in robust treatment planning for thoracic indications. A human-chest-size 4D phantom hosting inflatable porcine lungs and a corresponding 4DCT were used. Five PR frames were planned to intersect the phantom at various positions. Integral depth-dose curves (IDDs) per proton spot were measured using a multi-layer ionisation chamber (MLIC). Each PR frame consisted of 81 spots with an assigned energy of 210 MeV (FWHM 8.2 mm). Each frame was delivered 5 times while simultaneously acquiring the breathing signal of the 4D phantom, using an ANZAI load cell. The synchronised ANZAI and delivery log file information was used to retrospectively sort spots to their corresponding breathing phase. Based on this information, IDDs were simulated by the treatment planning system (TPS) Monte Carlo dose engine on a dose grid of 1 mm. In addition to the time-resolved TPS calculations on the 4DCT phases, IDD were calculated on the average CT. Measured IDDs were compared with simulated ones, calculating range error for each individual spot. In total 2025 proton spots were individually measured and analysed. Range error of a specific spot is reported relative to its water equivalent path length (WEPL). The mean relative range error was 1.2 % (1.5 SD 2.3 %) for the comparison with the time-resolved TPS calculations and 1.0 % (1.5 SD 2.2 %) when comparing to TPS calculations on the average CT. Determined mean relative range errors justify the use of 3% range uncertainty for robust treatment planning in clinical setting for thoracic indications.
- 31 July 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (15) , 155014
Open AccessAssessment of range uncertainty in lung-like tissue using a porcine lung phantom and proton radiography
Thoracic tumours are increasingly considered indications for pencil beam scanned proton therapy (PBS-PT) treatments. Conservative robustness settings have been suggested due to potential range straggling effects caused by the lung micro-structure. Using proton radiography (PR) and a 4D porcine lung phantom, we experimentally assess range errors to be considered in robust treatment planning for thoracic indications. A human-chest-size 4D phantom hosting inflatable porcine lungs and a corresponding 4DCT were used. Five PR frames were planned to intersect the phantom at various positions. Integral depth-dose curves (IDDs) per proton spot were measured using a multi-layer ionisation chamber (MLIC). Each PR frame consisted of 81 spots with an assigned energy of 210 MeV (FWHM 8.2 mm). Each frame was delivered 5 times while simultaneously acquiring the breathing signal of the 4D phantom, using an ANZAI load cell. The synchronised ANZAI and delivery log file information was used to retrospectively sort spots to their corresponding breathing phase. Based on this information, IDDs were simulated by the treatment planning system (TPS) Monte Carlo dose engine on a dose grid of 1 mm. In addition to the time-resolved TPS calculations on the 4DCT phases, IDD were calculated on the average CT. Measured IDDs were compared with simulated ones, calculating range error for each individual spot. In total 2025 proton spots were individually measured and analysed. Range error of a specific spot is reported relative to its water equivalent path length (WEPL). The mean relative range error was 1.2 % (1.5 SD 2.3 %) for the comparison with the time-resolved TPS calculations and 1.0 % (1.5 SD 2.2 %) when comparing to TPS calculations on the average CT. Determined mean relative range errors justify the use of 3% range uncertainty for robust treatment planning in clinical setting for thoracic indications.
- 1 February 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (3) , 03NT02
Validation of the proton range accuracy and optimization of CT calibration curves utilizing range probing
Proton therapy is affected by range uncertainty, which is partly caused by an ambiguous conversion from x-ray attenuation to proton stopping power. CT calibration curves, or Hounsfield look-up tables (HLUTs), are institution-specific and may be a source of systematic errors in treatment planning. A range probing method to verify, optimize and validate HLUTs for proton treatment is proposed. An initial HLUT was determined according to the stoichiometric approach. For HLUT validation, three types of animal tissue phantoms were prepared: a pig’s head, ‘thorax’ and femur. CT scans of the phantoms were taken and a structure, simulating a water slab, was added on the scan distal to the phantoms to mimic the detector used for integral depth-dose measurements. The CT scans were imported into the TPS to calculate individual pencil beams directed through the phantoms. The phantoms were positioned at the therapy system isocenter using x-ray imaging. Shoot-through pencil beams were delivered, and depth-dose profiles were measured using a multi-layer ionization chamber. Measured depth-dose curves were compared to the calculated curves and the range error per spot was determined. Based on the water equivalent path length (WEPL) of individual spot, a range error margin was defined. Ratios between measured error and theoretical margin were calculated per spot. The HLUT optimization was performed by identifying systematic shifts of the mean range error per phantom and minimizing the ratios between range errors and uncertainty margins. After optimization, the ratios of the actual range error and the uncertainty margin over the complete data set did not exceed 0.75 (1.5 SD), indicating that the actual errors are covered by the theoretical uncertainty recipe. The feasibility of using range probing to assess range errors was demonstrated. The theoretical uncertainty margins in the institution-specific setting potentially may be reduced by ~25%.
- 1 February 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (3) , 03NT02
Validation of the proton range accuracy and optimization of CT calibration curves utilizing range probing
Proton therapy is affected by range uncertainty, which is partly caused by an ambiguous conversion from x-ray attenuation to proton stopping power. CT calibration curves, or Hounsfield look-up tables (HLUTs), are institution-specific and may be a source of systematic errors in treatment planning. A range probing method to verify, optimize and validate HLUTs for proton treatment is proposed. An initial HLUT was determined according to the stoichiometric approach. For HLUT validation, three types of animal tissue phantoms were prepared: a pig’s head, ‘thorax’ and femur. CT scans of the phantoms were taken and a structure, simulating a water slab, was added on the scan distal to the phantoms to mimic the detector used for integral depth-dose measurements. The CT scans were imported into the TPS to calculate individual pencil beams directed through the phantoms. The phantoms were positioned at the therapy system isocenter using x-ray imaging. Shoot-through pencil beams were delivered, and depth-dose profiles were measured using a multi-layer ionization chamber. Measured depth-dose curves were compared to the calculated curves and the range error per spot was determined. Based on the water equivalent path length (WEPL) of individual spot, a range error margin was defined. Ratios between measured error and theoretical margin were calculated per spot. The HLUT optimization was performed by identifying systematic shifts of the mean range error per phantom and minimizing the ratios between range errors and uncertainty margins. After optimization, the ratios of the actual range error and the uncertainty margin over the complete data set did not exceed 0.75 (1.5 SD), indicating that the actual errors are covered by the theoretical uncertainty recipe. The feasibility of using range probing to assess range errors was demonstrated. The theoretical uncertainty margins in the institution-specific setting potentially may be reduced by ~25%.
- 7 August 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (5) , 055013
The effect of different CT scanners, scan parameters and scanning setup on Hounsfield units and calibrated bone density: a phantom study
This study investigated the effect of different CT scanners, reconstruction protocols, scan positions, and air gaps on HU and/or calibrated calcium hydroxyapatite concentrations (CaHA). Phantoms containing bone-like materials were scanned on four different CT scanners. The effect of slice thickness, field of view (FOV) and reconstruction kernel on HU was investigated. Using clinical scan and reconstruction protocols and a calibration phantom, HU and CaHA were determined for different positions, and air gaps between phantom and calibration phantom. Changing reconstruction kernel considerably affected the HU (range −31 HU to 64 HU), whereas slice thickness and FOV did not. Inter-scanner differences in HU were <88 HU and decreased to <47 CaHA after calibration. Different positions of the phantom resulted in differences (on average up to −26 HU and −24 CaHA). An air gap of 2.5 cm atop the calibration phantom resulted in errors up to −41 CaHA. If absolute HU and calibrated CaHA are needed, different reconstruction kernels and changes in position within the FOV as well as air gaps should be avoided.
- 7 August 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (5) , 055013
The effect of different CT scanners, scan parameters and scanning setup on Hounsfield units and calibrated bone density: a phantom study
This study investigated the effect of different CT scanners, reconstruction protocols, scan positions, and air gaps on HU and/or calibrated calcium hydroxyapatite concentrations (CaHA). Phantoms containing bone-like materials were scanned on four different CT scanners. The effect of slice thickness, field of view (FOV) and reconstruction kernel on HU was investigated. Using clinical scan and reconstruction protocols and a calibration phantom, HU and CaHA were determined for different positions, and air gaps between phantom and calibration phantom. Changing reconstruction kernel considerably affected the HU (range −31 HU to 64 HU), whereas slice thickness and FOV did not. Inter-scanner differences in HU were <88 HU and decreased to <47 CaHA after calibration. Different positions of the phantom resulted in differences (on average up to −26 HU and −24 CaHA). An air gap of 2.5 cm atop the calibration phantom resulted in errors up to −41 CaHA. If absolute HU and calibrated CaHA are needed, different reconstruction kernels and changes in position within the FOV as well as air gaps should be avoided.
- Open Access
- 1 April 2018
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 6, 25-30
Inter-centre variability of CT-based stopping-power prediction in particle therapy: Survey-based evaluation
- 1 April 2018
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 6, 25-30
Open AccessInter-centre variability of CT-based stopping-power prediction in particle therapy: Survey-based evaluation
- Open Access
- 6 March 2018
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 36 (8) , 2288-2295
Effect of different CT scanners and settings on femoral failure loads calculated by finite element models
In a multi‐center patient study, using different CT scanners, CT‐based finite element (FE) models are utilized to calculate failure loads of femora with metastases. Previous studies showed that using different CT scanners can result in different outcomes. This study aims to quantify the effects of (i) different CT scanners; (ii) different CT protocols with variations in slice thickness, field of view (FOV), and reconstruction kernel; and (iii) air between calibration phantom and patient, on Hounsfield Units (HU), bone mineral density (BMD), and FE failure load. Six cadaveric femora were scanned on four CT scanners. Scans were made with multiple CT protocols and with or without an air gap between the body model and calibration phantom. HU and calibrated BMD were determined in cortical and trabecular regions of interest. Non‐linear isotropic FE models were constructed to calculate failure load. Mean differences between CT scanners varied up to 7% in cortical HU, 6% in trabecular HU, 6% in cortical BMD, 12% in trabecular BMD, and 17% in failure load. Changes in slice thickness and FOV had little effect (≤4%), while reconstruction kernels had a larger effect on HU (16%), BMD (17%), and failure load (9%). Air between the body model and calibration phantom slightly decreased the HU, BMD, and failure loads (≤8%). In conclusion, this study showed that quantitative analysis of CT images acquired with different CT scanners, and particularly reconstruction kernels, can induce relatively large differences in HU, BMD, and failure loads. Additionally, if possible, air artifacts should be avoided. © 2018 Orthopaedic Research Society. © 2018 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of the Orthopaedic Research Society. J Orthop Res 36:2288–2295, 2018.
- 6 March 2018
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 36 (8) , 2288-2295
Open AccessEffect of different CT scanners and settings on femoral failure loads calculated by finite element models
In a multi‐center patient study, using different CT scanners, CT‐based finite element (FE) models are utilized to calculate failure loads of femora with metastases. Previous studies showed that using different CT scanners can result in different outcomes. This study aims to quantify the effects of (i) different CT scanners; (ii) different CT protocols with variations in slice thickness, field of view (FOV), and reconstruction kernel; and (iii) air between calibration phantom and patient, on Hounsfield Units (HU), bone mineral density (BMD), and FE failure load. Six cadaveric femora were scanned on four CT scanners. Scans were made with multiple CT protocols and with or without an air gap between the body model and calibration phantom. HU and calibrated BMD were determined in cortical and trabecular regions of interest. Non‐linear isotropic FE models were constructed to calculate failure load. Mean differences between CT scanners varied up to 7% in cortical HU, 6% in trabecular HU, 6% in cortical BMD, 12% in trabecular BMD, and 17% in failure load. Changes in slice thickness and FOV had little effect (≤4%), while reconstruction kernels had a larger effect on HU (16%), BMD (17%), and failure load (9%). Air between the body model and calibration phantom slightly decreased the HU, BMD, and failure loads (≤8%). In conclusion, this study showed that quantitative analysis of CT images acquired with different CT scanners, and particularly reconstruction kernels, can induce relatively large differences in HU, BMD, and failure loads. Additionally, if possible, air artifacts should be avoided. © 2018 Orthopaedic Research Society. © 2018 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of the Orthopaedic Research Society. J Orthop Res 36:2288–2295, 2018.