Erol Ozgur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Erol Ozgur has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Adrien Bartoli
University Hospital, Clermont-Ferrand, France
5 shared publicationsBertrand Le Roy
University Hospital, Saint-Etienne, France
3 shared publicationsEmmanuel Buc
University Hospital, Clermont-Ferrand, France
3 shared publications- Miguel Aranda
Instituto Universitario de Investigacin en Ingeniera de Aragn (I3A), Universidad de Zaragoza, Zaragoza, Spain
3 shared publications - Youcef Mezouar
CNRS, Clermont Auvergne INP, Institut Pascal, Universit Clermont Auvergne, Clermont-Ferrand, France
3 shared publications Bongjin Koo
EnCoV, IP, UMR 6602 CNRS, Universitè Clermont Auvergne, SIGMA, Aubière, France
2 shared publications
Latest Publications
- 29 April 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (9) , 2035-2045
Tumour-focused 3D-2D registration in liver laparoscopy
Purpose: Augmented reality (AR) is a promising tumour-resection guidance tool in liver laparoscopy. Existing methods register a preoperative liver 3D model (reconstructed from CT or MRI) to 2D laparoscopic images. They use surface landmarks to solve for registration and then transfer and overlay the internal tumour. This has two main weaknesses, hindering clinical adoption. First, computing the registration is highly challenging due to (i) multimodal and multidimensional correspondences (colourless 3D model to 2D RGB images), (ii) restricted field of view (proximity of laparoscope to parenchyma), and (iii) liver deformations (breathing and instrument interactions). Second, extrapolating from the surface to deeper tumours increases uncertainty and may result in inaccurate AR. Methods: We propose tumour-focused 3D-2D registration (Tf32), a method that registers the tumour, not the parenchyma. Tf32 exploits laparoscopic ultrasonography (LUS), which provides intraoperative cross-sections of the tumour and can be reliably localised with respect to the laparoscope. Tf32 matches the LUS tumour profile to a set of tumour profiles simulated preoperatively from the preoperative tumour 3D model. This initial registration is then refined using iterative closest point (ICP). A multiple-hypothesis implementation handles ambiguities and local minima arising from the finite profile sample set. Results: Tf32 achieved 91.07% success rate in meeting the \(10\,\text {mm}\) oncological margin on semi-synthetic data and established a new state-of-the-art on a public benchmark dataset. Conclusion: Compared with competitors, Tf32 does not require manual initialisation nor the full liver 3D model and is notably more accurate, making it well-adapted to clinical use.- 29 April 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (9) , 2035-2045
Tumour-focused 3D-2D registration in liver laparoscopy
Purpose: Augmented reality (AR) is a promising tumour-resection guidance tool in liver laparoscopy. Existing methods register a preoperative liver 3D model (reconstructed from CT or MRI) to 2D laparoscopic images. They use surface landmarks to solve for registration and then transfer and overlay the internal tumour. This has two main weaknesses, hindering clinical adoption. First, computing the registration is highly challenging due to (i) multimodal and multidimensional correspondences (colourless 3D model to 2D RGB images), (ii) restricted field of view (proximity of laparoscope to parenchyma), and (iii) liver deformations (breathing and instrument interactions). Second, extrapolating from the surface to deeper tumours increases uncertainty and may result in inaccurate AR. Methods: We propose tumour-focused 3D-2D registration (Tf32), a method that registers the tumour, not the parenchyma. Tf32 exploits laparoscopic ultrasonography (LUS), which provides intraoperative cross-sections of the tumour and can be reliably localised with respect to the laparoscope. Tf32 matches the LUS tumour profile to a set of tumour profiles simulated preoperatively from the preoperative tumour 3D model. This initial registration is then refined using iterative closest point (ICP). A multiple-hypothesis implementation handles ambiguities and local minima arising from the finite profile sample set. Results: Tf32 achieved 91.07% success rate in meeting the \(10\,\text {mm}\) oncological margin on semi-synthetic data and established a new state-of-the-art on a public benchmark dataset. Conclusion: Compared with competitors, Tf32 does not require manual initialisation nor the full liver 3D model and is notably more accurate, making it well-adapted to clinical use.- 6 March 2026
- Published by Springer Nature in International Journal of Computer Vision
- Vol. 134 (4) , 151
Reconstructing a Sphere and the Camera Focal Length from a Single View by Fitting Planes
- 6 March 2026
- Published by Springer Nature in International Journal of Computer Vision
- Vol. 134 (4) , 151
Reconstructing a Sphere and the Camera Focal Length from a Single View by Fitting Planes
- Open Access
ROBUSfT: Robust Real-Time Shape-from-Template, a C++ Library
Tracking the 3D shape of a deforming object using only monocular 2D vision is a challenging problem. This is because one should (i) infer the 3D shape from a 2D image, which is a severely underconstrained problem, and (ii) implement the whole solution pipeline in real-time. The pipeline typically requires feature detection and matching, mismatch filtering, 3D shape inference and feature tracking algorithms. We propose ROBUSfT, a conventional pipeline based on a template containing the object's rest shape, texturemap and deformation law. ROBUSfT is ready-to-use, wide-baseline, capable of handling large deformations, fast up to 30 fps, free of training, and robust against partial occlusions and discontinuity in video frames. It outperforms the state-of-the-art methods in challenging datasets. ROBUSfT is implemented as a publicly available C++ library and we provide a tutorial on how to use it in https://github.com/mrshetab/ROBUSfT
Open AccessROBUSfT: Robust Real-Time Shape-from-Template, a C++ Library
Tracking the 3D shape of a deforming object using only monocular 2D vision is a challenging problem. This is because one should (i) infer the 3D shape from a 2D image, which is a severely underconstrained problem, and (ii) implement the whole solution pipeline in real-time. The pipeline typically requires feature detection and matching, mismatch filtering, 3D shape inference and feature tracking algorithms. We propose ROBUSfT, a conventional pipeline based on a template containing the object's rest shape, texturemap and deformation law. ROBUSfT is ready-to-use, wide-baseline, capable of handling large deformations, fast up to 30 fps, free of training, and robust against partial occlusions and discontinuity in video frames. It outperforms the state-of-the-art methods in challenging datasets. ROBUSfT is implemented as a publicly available C++ library and we provide a tutorial on how to use it in https://github.com/mrshetab/ROBUSfT
- 9 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 40 (15523098) , 364-381
Lattice-Based Shape Tracking and Servoing of Elastic Objects
In this article, we propose a general unified tracking-servoing approach for controlling the shape of elastic deformable objects using robotic arms. Our approach works by forming a lattice around the object, binding the object to the lattice, and tracking and servoing the lattice instead of the object. This makes our approach have full control over the deformation of elastic deformable objects of any general form (linear, thin-shell, and volumetric) in 3-D space. Furthermore, it decouples the runtime complexity of the approach from the objects' geometric complexity. Our approach is based on the as-rigid-as-possible deformation model. It requires no mechanical parameter of the object to be known and can drive the object toward desired shapes through large deformations. The inputs to our approach are the point cloud of the object's surface in its rest shape and the point cloud captured by a 3-D camera in each frame. Overall, our approach is more broadly applicable than existing approaches. We validate the efficiency of our approach through numerous experiments with elastic deformable objects of various shapes and materials (paper, rubber, plastic, and foam).
- 9 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 40 (15523098) , 364-381
Lattice-Based Shape Tracking and Servoing of Elastic Objects
In this article, we propose a general unified tracking-servoing approach for controlling the shape of elastic deformable objects using robotic arms. Our approach works by forming a lattice around the object, binding the object to the lattice, and tracking and servoing the lattice instead of the object. This makes our approach have full control over the deformation of elastic deformable objects of any general form (linear, thin-shell, and volumetric) in 3-D space. Furthermore, it decouples the runtime complexity of the approach from the objects' geometric complexity. Our approach is based on the as-rigid-as-possible deformation model. It requires no mechanical parameter of the object to be known and can drive the object toward desired shapes through large deformations. The inputs to our approach are the point cloud of the object's surface in its rest shape and the point cloud captured by a 3-D camera in each frame. Overall, our approach is more broadly applicable than existing approaches. We validate the efficiency of our approach through numerous experiments with elastic deformable objects of various shapes and materials (paper, rubber, plastic, and foam).
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (2) , 3898-3905
As-Rigid-as-Possible Shape Servoing
Shape servoing is the problem of controlling the shape of a deformable object via robotic manipulation, exploiting sensory feedback. In many shape servoing scenarios of practical interest, the object has a natural tendency to preserve local rigidity. Motivated by this observation, we propose to use the As-Rigid-As-Possible deformation model for shape servoing. Specifically, we propose a novel control scheme based on a deformation Jacobian computed from this model. The proposed scheme drives the object to a desired 3D shape using as feedback the object’s measured current 3D shape. The scheme is simple to implement, and it avoids some typical requirements in existing work: specifically, (i) we do not need to know the object’s mechanical deformation parameters, and (ii) we do not use a Jacobian computed from data collected over a time window while the robots move. We test the proposed scheme in bi-arm shape servoing experiments with a variety of deformable objects of different material (paper, rubber, plastic). Tracking of the deformable object’s surface in 3D is performed in our experiments via an algorithm based on monocular vision. The experimental results validate the practicality of our scheme.
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (2) , 3898-3905
As-Rigid-as-Possible Shape Servoing
Shape servoing is the problem of controlling the shape of a deformable object via robotic manipulation, exploiting sensory feedback. In many shape servoing scenarios of practical interest, the object has a natural tendency to preserve local rigidity. Motivated by this observation, we propose to use the As-Rigid-As-Possible deformation model for shape servoing. Specifically, we propose a novel control scheme based on a deformation Jacobian computed from this model. The proposed scheme drives the object to a desired 3D shape using as feedback the object’s measured current 3D shape. The scheme is simple to implement, and it avoids some typical requirements in existing work: specifically, (i) we do not need to know the object’s mechanical deformation parameters, and (ii) we do not use a Jacobian computed from data collected over a time window while the robots move. We test the proposed scheme in bi-arm shape servoing experiments with a variety of deformable objects of different material (paper, rubber, plastic). Tracking of the deformable object’s surface in 3D is performed in our experiments via an algorithm based on monocular vision. The experimental results validate the practicality of our scheme.
- 9 August 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 13 (10) , 1629-1640
Preoperative liver registration for augmented monocular laparoscopy using backward–forward biomechanical simulation
Augmented reality for monocular laparoscopy from a preoperative volume such as CT is achieved in two steps. The first step is to segment the organ in the preoperative volume and reconstruct its 3D model. The second step is to register the preoperative 3D model to an initial intraoperative laparoscopy image. To date, there does not exist an automatic initial registration method to solve the second step for the liver in the de facto operating room conditions of monocular laparoscopy. Existing methods attempt to solve for both deformation and pose simultaneously, leading to nonconvex problems with no optimal solution algorithms.
- 9 August 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 13 (10) , 1629-1640
Preoperative liver registration for augmented monocular laparoscopy using backward–forward biomechanical simulation
Augmented reality for monocular laparoscopy from a preoperative volume such as CT is achieved in two steps. The first step is to segment the organ in the preoperative volume and reconstruct its 3D model. The second step is to register the preoperative 3D model to an initial intraoperative laparoscopy image. To date, there does not exist an automatic initial registration method to solve the second step for the liver in the de facto operating room conditions of monocular laparoscopy. Existing methods attempt to solve for both deformation and pose simultaneously, leading to nonconvex problems with no optimal solution algorithms.
- 4 September 2017
- Published by Springer Nature
- p. 326-334
Deformable Registration of a Preoperative 3D Liver Volume to a Laparoscopy Image Using Contour and Shading Cues
- 4 September 2017
- Published by Springer Nature
- p. 326-334
Deformable Registration of a Preoperative 3D Liver Volume to a Laparoscopy Image Using Contour and Shading Cues
- 3 November 2016
- Published by Springer Nature in International Journal of Computer Vision
- Vol. 123 (2) , 184-205
Particle-SfT: A Provably-Convergent, Fast Shape-from-Template Algorithm
- 3 November 2016
- Published by Springer Nature in International Journal of Computer Vision
- Vol. 123 (2) , 184-205
Particle-SfT: A Provably-Convergent, Fast Shape-from-Template Algorithm