Tracie R. Jackson
Research Subjects
Research Interests
Tracie R. Jackson has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Keith J. Halford
U.S. Geological Survey, Carson City, NV 89701, USA
6 shared publications - Joseph M. Fenelon
US Geological Survey (retired), Henderson, USA
5 shared publications Guosheng Zhan
3 shared publications- Donald S. Sweetkind
U.S. Geological Survey
2 shared publications U.S. Geological Survey
2 shared publicationsAmanda Garcia
US Geological Survey, Oregon Water Science Center, 2130 SW 5th Ave., Portland, OR 97201
1 shared publication
Latest Publications
- 18 May 2026
- Published by Springer Nature in Mine Water and the Environment
- Vol. 45 (2) , 322-339
Tailings Storage Facility Iterative Simulation Model (TSFISM): A Dynamic Simulator
- 18 May 2026
- Published by Springer Nature in Mine Water and the Environment
- Vol. 45 (2) , 322-339
Tailings Storage Facility Iterative Simulation Model (TSFISM): A Dynamic Simulator
- 11 February 2026
- Published by Springer Nature in Mine Water and the Environment
- Vol. 45 (2) , 340-352
Pit-Lake Iterative Simulation Model (PLISM): An Iterative Solver
- 11 February 2026
- Published by Springer Nature in Mine Water and the Environment
- Vol. 45 (2) , 340-352
Pit-Lake Iterative Simulation Model (PLISM): An Iterative Solver
- 1 June 2024
- Published by Springer Nature in Mine Water and the Environment
- Vol. 43 (2) , 294-312
Coupled Baseline Estimation and Trend Analysis Approach to Differentiate Natural and Mine-Related Stresses on Groundwater Levels
- 1 June 2024
- Published by Springer Nature in Mine Water and the Environment
- Vol. 43 (2) , 294-312
Coupled Baseline Estimation and Trend Analysis Approach to Differentiate Natural and Mine-Related Stresses on Groundwater Levels
- Open Access
- 31 January 2024
- Published by Springer Nature in Research Square
Coupled Baseline Estimation and Trend Analysis Approach to Differentiate Natural and Mine-Related Stresses on Groundwater Levels
Permitting and regulatory obligations require mine operators to periodically report the spatial extent of mine-induced water-level changes, and to provide water-level monitoring data for review, along with explanations of all hydrologic stresses causing water-level trends. This study couples a baseline-estimation method with a curve-fitting trend-analysis approach to determine all natural, mining, and non-mining aquifer stresses affecting water levels in wells. The approach was applied to the Twin Creeks Mine monitoring network in north-central Nevada, USA. Stresses identified in wells were used to delineate the approximate extent of pumping effects and indicated that drawdowns have not coalesced between mining and non-mining pumping areas. Trend-analysis results indicated that ten study-area well hydrographs have natural trends, and statistical methods identified three of these wells as having statistically significant downward trends. Thus, caution should be used when interpreting the meaning of statistically significant downward trends, because the downward trend may be climate driven rather than pumping related. The curve-matching approach requires the development of a baseline water-level trend to understand expected natural fluctuations. The baseline trend assumes a dynamic-equilibrium natural condition, where long-term net changes in groundwater levels are zero. The baseline trend and trend analysis require a recharge proxy for the study area. This study developed recharge proxies using winter precipitation data, peak reservoir-storage volumes, and metered mine-water discharge to a surface-water channel. The curve-matching approach also can be used to identify and remove erroneous data, reconcile water-level and pumping datasets, or build hydrologic conceptualizations.
- 31 January 2024
- Published by Springer Nature in Research Square
Open AccessCoupled Baseline Estimation and Trend Analysis Approach to Differentiate Natural and Mine-Related Stresses on Groundwater Levels
Permitting and regulatory obligations require mine operators to periodically report the spatial extent of mine-induced water-level changes, and to provide water-level monitoring data for review, along with explanations of all hydrologic stresses causing water-level trends. This study couples a baseline-estimation method with a curve-fitting trend-analysis approach to determine all natural, mining, and non-mining aquifer stresses affecting water levels in wells. The approach was applied to the Twin Creeks Mine monitoring network in north-central Nevada, USA. Stresses identified in wells were used to delineate the approximate extent of pumping effects and indicated that drawdowns have not coalesced between mining and non-mining pumping areas. Trend-analysis results indicated that ten study-area well hydrographs have natural trends, and statistical methods identified three of these wells as having statistically significant downward trends. Thus, caution should be used when interpreting the meaning of statistically significant downward trends, because the downward trend may be climate driven rather than pumping related. The curve-matching approach requires the development of a baseline water-level trend to understand expected natural fluctuations. The baseline trend assumes a dynamic-equilibrium natural condition, where long-term net changes in groundwater levels are zero. The baseline trend and trend analysis require a recharge proxy for the study area. This study developed recharge proxies using winter precipitation data, peak reservoir-storage volumes, and metered mine-water discharge to a surface-water channel. The curve-matching approach also can be used to identify and remove erroneous data, reconcile water-level and pumping datasets, or build hydrologic conceptualizations.
- Open Access
- 31 March 2023
- Published by Springer Nature in Communications Earth & Environment
- Vol. 4 (1) , 1-10
A 350,000-year history of groundwater recharge in the southern Great Basin, USA
Estimating groundwater recharge under various climate conditions is important for predicting future freshwater availability. This is especially true for the water-limited region of the southern Great Basin, USA. To investigate the response of groundwater recharge to different climate states, we calculate the paleo recharge to a groundwater basin in southern Nevada over the last 350,000 years. Our approach combines a groundwater model with paleo-water-table data from Devils Hole cave. The minimum water-table during peak interglacial conditions was more than 1.6 m below modern levels, representing a recharge decline of less than 17% from present-day conditions. During peak glacial conditions, the water-table elevation was at least 9.5 m above modern levels, representing a recharge increase of more than 233–244% compared to present-day conditions. The elevation of the Devils Hole water-table is 3–4 times more sensitive to groundwater recharge during dry interglacial periods, compared to wet glacial periods. This study can serve as a benchmark for understanding long-term effects of past and future climate change on groundwater resources.
- 31 March 2023
- Published by Springer Nature in Communications Earth & Environment
- Vol. 4 (1) , 1-10
Open AccessA 350,000-year history of groundwater recharge in the southern Great Basin, USA
Estimating groundwater recharge under various climate conditions is important for predicting future freshwater availability. This is especially true for the water-limited region of the southern Great Basin, USA. To investigate the response of groundwater recharge to different climate states, we calculate the paleo recharge to a groundwater basin in southern Nevada over the last 350,000 years. Our approach combines a groundwater model with paleo-water-table data from Devils Hole cave. The minimum water-table during peak interglacial conditions was more than 1.6 m below modern levels, representing a recharge decline of less than 17% from present-day conditions. During peak glacial conditions, the water-table elevation was at least 9.5 m above modern levels, representing a recharge increase of more than 233–244% compared to present-day conditions. The elevation of the Devils Hole water-table is 3–4 times more sensitive to groundwater recharge during dry interglacial periods, compared to wet glacial periods. This study can serve as a benchmark for understanding long-term effects of past and future climate change on groundwater resources.
- Open Access
- 1 January 2023
- Published by US Geological Survey
Evaluation of potential stresses and hydrologic conditions driving water-level fluctuations in well ER-5-3-2, Frenchman Flat, southern Nevada
Well ER-5-3-2 is part of a well network designed to monitor long-term water levels and radionuclide concentrations downgradient from underground nuclear tests that occurred in Frenchman Flat, an area of the U.S. Department of Energy Nevada National Security Site in southern Nevada. Interpretation of monitoring records for well ER-5-3-2 was confounded by previously unexplained water-level fluctuations in the well hydrograph. This study integrated geologic, hydrologic, and water-chemistry data to evaluate potential stresses and hydrologic conditions that likely affected the well ER-5-3-2 hydrograph. Numerical groundwater models were applied to evaluate four model scenarios: (1) wellbore leakage without recharge, (2) wellbore leakage with recharge, (3) equilibration to vertical heterogeneities between shallow (low transmissivity) and deep (higher transmissivity) carbonate zones, and (4) equilibration to lateral heterogeneities in carbonate rocks.Meteoric recharge was not the cause of the 21-foot (ft) water-level rise in well ER-5-3-2 from 2001 to 2011 or the 4-ft decline from 2012 to 2016. Based on observed water-level fluctuations in nearby wells, the water-level rise and decline from recharge for these periods was less than 3 and 1 ft, respectively. The lateral-heterogeneity scenario is based on the assumption that the 21-ft water-level rise from 2001 to 2011 was a natural water-level reequilibration following the pumping-induced depressurization of a large volume of high transmissivity and low-storage carbonate rock that is surrounded by low transmissivity and high-storage carbonate rock. The lateral-heterogeneity scenario was discounted because simulated water levels cannot match the well ER-5-3-2 hydrograph. Underground nuclear testing and temperature effects were discounted based on hydraulic connections and water-temperature data.Wellbore-leakage scenarios are based on the assumption that the water-level rise was sustained from leakage rates required to cause a localized mounding in the carbonate system near well ER-5-3-2, where the carbonate transmissivity is 530 square feet per day. Even though simulated and measured water levels compare favorably for scenarios of wellbore leakage with and without recharge, large volumes (178–184 million gallons) of groundwater from volcanic rocks would be required to leak into the carbonate system, which is not supported by water-chemistry data.An alternative conceptualization of wellbore leakage is based on the assumption that the 21-ft water-level rise from 2001 to 2011 was sustained by the hydraulic disconnection of well ER-5-3-2 from the carbonate system. The disconnection occurred several months after a constant-rate test in well ER-5-3-2 when carbonate rocks were hydraulically disconnected from the well by either (1) the shifting of sloughed fill in the open hole or (2) the encrusting of carbonate precipitate in the well screen. The hydraulic disconnection effectively sealed the well and caused a 21-ft water-level rise from wellbore leakage during 2001–11. In this case, total wellbore leakage from 2001 to 2011 was about 50 gallons. The 4-ft water-level decline from 2012 to 2016 was conceptualized to have occurred from the slow breaking of the seal and reconnection of the well to the carbonate system. This alternative conceptualization of wellbore leakage was consistent with water-chemistry analyses because the computed wellbore leakage (50 gallons) was small relative to purged volumes (30,000–40,000 gallons) for sampling, and the water chemistry would not be expected to change.The shallow-deep carbonate scenario provided another explanation for the well ER-5-3-2 hydrograph. This scenario is based on the assumption that well-construction effects and vertical heterogeneity of the carbonate system explain the ER-5-3-2 water-level trend. Well-construction effects are attributed to a temporary clogging of the open interval below the well screen that was opened during pumping events, which affected the hydraulic connection of deep transmissive carbonate rocks to the wellbore. The 21-ft water-level rise from 2001 to 2011 was a natural equilibration to shallow, low-transmissivity carbonate rocks during a period when the lower open interval was clogged. The 4-ft decline from 2012 to 2016 represents equilibration between the shallow and deep intervals, because of a partial unclogging of the connection between the two intervals. The low water levels from 2016 to 2021 resulted from pumping for sampling and an unclogging of the open interval so that the low head in the deep carbonate dominated the water level. Despite potential well-construction effects, from either a wellbore leakage or shallow-deep carbonate scenario, samples collected from well ER-5-3-2 are representative of the carbonate system.
- 1 January 2023
- Published by US Geological Survey
Open AccessEvaluation of potential stresses and hydrologic conditions driving water-level fluctuations in well ER-5-3-2, Frenchman Flat, southern Nevada
Well ER-5-3-2 is part of a well network designed to monitor long-term water levels and radionuclide concentrations downgradient from underground nuclear tests that occurred in Frenchman Flat, an area of the U.S. Department of Energy Nevada National Security Site in southern Nevada. Interpretation of monitoring records for well ER-5-3-2 was confounded by previously unexplained water-level fluctuations in the well hydrograph. This study integrated geologic, hydrologic, and water-chemistry data to evaluate potential stresses and hydrologic conditions that likely affected the well ER-5-3-2 hydrograph. Numerical groundwater models were applied to evaluate four model scenarios: (1) wellbore leakage without recharge, (2) wellbore leakage with recharge, (3) equilibration to vertical heterogeneities between shallow (low transmissivity) and deep (higher transmissivity) carbonate zones, and (4) equilibration to lateral heterogeneities in carbonate rocks.Meteoric recharge was not the cause of the 21-foot (ft) water-level rise in well ER-5-3-2 from 2001 to 2011 or the 4-ft decline from 2012 to 2016. Based on observed water-level fluctuations in nearby wells, the water-level rise and decline from recharge for these periods was less than 3 and 1 ft, respectively. The lateral-heterogeneity scenario is based on the assumption that the 21-ft water-level rise from 2001 to 2011 was a natural water-level reequilibration following the pumping-induced depressurization of a large volume of high transmissivity and low-storage carbonate rock that is surrounded by low transmissivity and high-storage carbonate rock. The lateral-heterogeneity scenario was discounted because simulated water levels cannot match the well ER-5-3-2 hydrograph. Underground nuclear testing and temperature effects were discounted based on hydraulic connections and water-temperature data.Wellbore-leakage scenarios are based on the assumption that the water-level rise was sustained from leakage rates required to cause a localized mounding in the carbonate system near well ER-5-3-2, where the carbonate transmissivity is 530 square feet per day. Even though simulated and measured water levels compare favorably for scenarios of wellbore leakage with and without recharge, large volumes (178–184 million gallons) of groundwater from volcanic rocks would be required to leak into the carbonate system, which is not supported by water-chemistry data.An alternative conceptualization of wellbore leakage is based on the assumption that the 21-ft water-level rise from 2001 to 2011 was sustained by the hydraulic disconnection of well ER-5-3-2 from the carbonate system. The disconnection occurred several months after a constant-rate test in well ER-5-3-2 when carbonate rocks were hydraulically disconnected from the well by either (1) the shifting of sloughed fill in the open hole or (2) the encrusting of carbonate precipitate in the well screen. The hydraulic disconnection effectively sealed the well and caused a 21-ft water-level rise from wellbore leakage during 2001–11. In this case, total wellbore leakage from 2001 to 2011 was about 50 gallons. The 4-ft water-level decline from 2012 to 2016 was conceptualized to have occurred from the slow breaking of the seal and reconnection of the well to the carbonate system. This alternative conceptualization of wellbore leakage was consistent with water-chemistry analyses because the computed wellbore leakage (50 gallons) was small relative to purged volumes (30,000–40,000 gallons) for sampling, and the water chemistry would not be expected to change.The shallow-deep carbonate scenario provided another explanation for the well ER-5-3-2 hydrograph. This scenario is based on the assumption that well-construction effects and vertical heterogeneity of the carbonate system explain the ER-5-3-2 water-level trend. Well-construction effects are attributed to a temporary clogging of the open interval below the well screen that was opened during pumping events, which affected the hydraulic connection of deep transmissive carbonate rocks to the wellbore. The 21-ft water-level rise from 2001 to 2011 was a natural equilibration to shallow, low-transmissivity carbonate rocks during a period when the lower open interval was clogged. The 4-ft decline from 2012 to 2016 represents equilibration between the shallow and deep intervals, because of a partial unclogging of the connection between the two intervals. The low water levels from 2016 to 2021 resulted from pumping for sampling and an unclogging of the open interval so that the low head in the deep carbonate dominated the water level. Despite potential well-construction effects, from either a wellbore leakage or shallow-deep carbonate scenario, samples collected from well ER-5-3-2 are representative of the carbonate system.
- 16 November 2022
- Published by Springer Nature in Hydrogeology Journal
- Vol. 30 (8) , 2417-2432
Relation of hydraulic conductivity to depth, alteration, and rock type in the volcanic rocks of Pahute Mesa, Nevada, USA
- 16 November 2022
- Published by Springer Nature in Hydrogeology Journal
- Vol. 30 (8) , 2417-2432
Relation of hydraulic conductivity to depth, alteration, and rock type in the volcanic rocks of Pahute Mesa, Nevada, USA
- Open Access
- 9 March 2022
- Published by Wiley in Groundwater
- Vol. 60 (4) , 496-509
Pervasive, Preferential Flow through Mega‐Thick Unsaturated Zones in the Southern Great Basin
Recharge from preferential flow through mega‐thick (100–1000 m) unsaturated zones is a pervasive phenomenon, as demonstrated with a case study of volcanic highland recharge areas in the Great Basin province in southern Nevada, USA. Statistically significant rising water‐level trends occur for most study‐area wells and resulted from a relatively wet period (1969–2005) in south‐central Nevada. Wet and dry winters control water‐level trends, with water levels rising within a few months to a year following a wet‐winter recharge event and declining during sustained dry periods. Even though a megadrought has persisted since 2000, this drought condition did not preclude major recharge events. Modern groundwater reaching the water table is consistent with previous geochemical studies of the study area that indicate mixing of modern and late Pleistocene recharge water. First‐order approximations and simple mixing models of modern and late Pleistocene water indicate that 10% to 40% of recharge is preferential flow and that modern recharge may play a larger role in the water budget than previously thought.
- 9 March 2022
- Published by Wiley in Groundwater
- Vol. 60 (4) , 496-509
Open AccessPervasive, Preferential Flow through Mega‐Thick Unsaturated Zones in the Southern Great Basin
Recharge from preferential flow through mega‐thick (100–1000 m) unsaturated zones is a pervasive phenomenon, as demonstrated with a case study of volcanic highland recharge areas in the Great Basin province in southern Nevada, USA. Statistically significant rising water‐level trends occur for most study‐area wells and resulted from a relatively wet period (1969–2005) in south‐central Nevada. Wet and dry winters control water‐level trends, with water levels rising within a few months to a year following a wet‐winter recharge event and declining during sustained dry periods. Even though a megadrought has persisted since 2000, this drought condition did not preclude major recharge events. Modern groundwater reaching the water table is consistent with previous geochemical studies of the study area that indicate mixing of modern and late Pleistocene recharge water. First‐order approximations and simple mixing models of modern and late Pleistocene water indicate that 10% to 40% of recharge is preferential flow and that modern recharge may play a larger role in the water budget than previously thought.
- Open Access
- 1 January 2021
- Published by US Geological Survey
Permeable groundwater pathways and tritium migration patterns from the HANDLEY underground nuclear test, Pahute Mesa, Nevada
First posted June 16, 2021 Director, Nevada Water Science Center U.S. Geological Survey 2730 N. Deer Run Road Carson City, Nevada 89701 The HANDLEY nuclear test was detonated at about 2,700 feet below the water table on March 26, 1970, in Pahute Mesa, south-central Nevada. Measured tritium concentrations in boreholes ER-20-12 and PM-3 indicate that a shallow tritium plume has migrated more than 1 mile (mi) downgradient from the HANDLEY test within a semi-perched aquifer and deeper tritium plumes have migrated 4.5 miles (mi) within underlying regional aquifers. Boreholes ER-20-12 and PM-3 are in an area of moderate-to-low transmissivity, but observation of tritium moving 4.5 mi within 40 years of the detonation indicates that high-transmissivity intervals exist. However, the location of these permeable pathways is unknown. This report integrates geologic, hydrologic, and tritium data to infer the location of permeable pathways near and downgradient from the HANDLEY test. Numerical groundwater-flow and tritium-transport models were developed to estimate hydraulic and transport properties between the HANDLEY test and boreholes ER-20-12 and PM-3. Recharge, hydraulic-conductivity, specific-yield, specific-storage, and effective-porosity distributions were estimated with the numerical models by fitting simulated water-level altitudes, vertical-head differences, aquifer-test transmissivities, tritium concentrations, and drawdowns in wells PM-3-1 and PM-3-2 to measured equivalents. Drawdowns were estimated in wells PM-3-1 and PM-3-2 in response to groundwater withdrawals during the drilling of borehole ER-20-12. A modified hydrostratigraphic framework model (mHFM) was developed that incorporates hydrostratigraphic units (HSUs) from the Pahute Mesa–Oasis Valley hydrostratigraphic framework model (PMOV HFM). HSUs in the mHFM were modified from the PMOV HFM by grouping HSUs that, conceptually, are hydraulically similar and splitting HSUs based on water-level, aquifer-test, and tritium data. Shallow and deeper tritium plumes have migrated to borehole ER-20-12 from the HANDLEY test. The shallow plume migrated from the HANDLEY test through the Timber Mountain welded tuff aquifer, whereas the deeper plumes moved through the Belted Range aquifer (BRA) and modified pre-Belted Range lava flow aquifer (mPBRLFA). Simulated tritium concentrations indicate that the leading edges of tritium plumes reached borehole ER-20-12 by 1990. From 1970 to 2020, the simulated tritium load mostly occurs between borehole ER-20-12 and the HANDLEY test. An unmapped permeable feature was simulated between borehole ER-20-12 and the downgradient Ribbon Cliff structural zone. This permeable feature hydraulically connects the BRA and mPBRLFA with the Tiva Canyon aquifer (TCA). The TCA is the most transmissive unit in the study area. Simulated tritium from the deeper plumes moves through the permeable feature downgradient from borehole ER-20-12 and then migrates toward well PM-3-1 through the TCA. The leading edge of the deeper simulated tritium plumes reaches well PM-3-1 by 2010. The mHFM and PMOV HFM do not include a permeable HSU at the water table near borehole PM-3, which is necessary for numerical flow and transport models to match measured water levels, transmissivities, and tritium concentrations in well PM-3-2. Consistently higher measured tritium concentrations in shallow well PM-3-2, compared to deeper well PM-3-1, and a downward vertical gradient between these wells indicate that a permeable feature exists near the water table that causes faster tritium migration toward the shallow well. Reevaluation of the PMOV HFM and geologic investigations, such as drilling another well, are needed to more precisely understand the shallow permeable pathway from the Handley test to well PM-3-2.
- 1 January 2021
- Published by US Geological Survey
Open AccessPermeable groundwater pathways and tritium migration patterns from the HANDLEY underground nuclear test, Pahute Mesa, Nevada
First posted June 16, 2021 Director, Nevada Water Science Center U.S. Geological Survey 2730 N. Deer Run Road Carson City, Nevada 89701 The HANDLEY nuclear test was detonated at about 2,700 feet below the water table on March 26, 1970, in Pahute Mesa, south-central Nevada. Measured tritium concentrations in boreholes ER-20-12 and PM-3 indicate that a shallow tritium plume has migrated more than 1 mile (mi) downgradient from the HANDLEY test within a semi-perched aquifer and deeper tritium plumes have migrated 4.5 miles (mi) within underlying regional aquifers. Boreholes ER-20-12 and PM-3 are in an area of moderate-to-low transmissivity, but observation of tritium moving 4.5 mi within 40 years of the detonation indicates that high-transmissivity intervals exist. However, the location of these permeable pathways is unknown. This report integrates geologic, hydrologic, and tritium data to infer the location of permeable pathways near and downgradient from the HANDLEY test. Numerical groundwater-flow and tritium-transport models were developed to estimate hydraulic and transport properties between the HANDLEY test and boreholes ER-20-12 and PM-3. Recharge, hydraulic-conductivity, specific-yield, specific-storage, and effective-porosity distributions were estimated with the numerical models by fitting simulated water-level altitudes, vertical-head differences, aquifer-test transmissivities, tritium concentrations, and drawdowns in wells PM-3-1 and PM-3-2 to measured equivalents. Drawdowns were estimated in wells PM-3-1 and PM-3-2 in response to groundwater withdrawals during the drilling of borehole ER-20-12. A modified hydrostratigraphic framework model (mHFM) was developed that incorporates hydrostratigraphic units (HSUs) from the Pahute Mesa–Oasis Valley hydrostratigraphic framework model (PMOV HFM). HSUs in the mHFM were modified from the PMOV HFM by grouping HSUs that, conceptually, are hydraulically similar and splitting HSUs based on water-level, aquifer-test, and tritium data. Shallow and deeper tritium plumes have migrated to borehole ER-20-12 from the HANDLEY test. The shallow plume migrated from the HANDLEY test through the Timber Mountain welded tuff aquifer, whereas the deeper plumes moved through the Belted Range aquifer (BRA) and modified pre-Belted Range lava flow aquifer (mPBRLFA). Simulated tritium concentrations indicate that the leading edges of tritium plumes reached borehole ER-20-12 by 1990. From 1970 to 2020, the simulated tritium load mostly occurs between borehole ER-20-12 and the HANDLEY test. An unmapped permeable feature was simulated between borehole ER-20-12 and the downgradient Ribbon Cliff structural zone. This permeable feature hydraulically connects the BRA and mPBRLFA with the Tiva Canyon aquifer (TCA). The TCA is the most transmissive unit in the study area. Simulated tritium from the deeper plumes moves through the permeable feature downgradient from borehole ER-20-12 and then migrates toward well PM-3-1 through the TCA. The leading edge of the deeper simulated tritium plumes reaches well PM-3-1 by 2010. The mHFM and PMOV HFM do not include a permeable HSU at the water table near borehole PM-3, which is necessary for numerical flow and transport models to match measured water levels, transmissivities, and tritium concentrations in well PM-3-2. Consistently higher measured tritium concentrations in shallow well PM-3-2, compared to deeper well PM-3-1, and a downward vertical gradient between these wells indicate that a permeable feature exists near the water table that causes faster tritium migration toward the shallow well. Reevaluation of the PMOV HFM and geologic investigations, such as drilling another well, are needed to more precisely understand the shallow permeable pathway from the Handley test to well PM-3-2.