Katherine Marlene McKendy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Katherine Marlene McKendy has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Evan Gordon Wong
Department of General Surgery and Critical Care Medicine McGill University Montréal Quebec Canada
3 shared publications - Gerald M. Fried
Department of Surgery, McGill University, Montreal, QC, Canada
3 shared publications Melina C. Vassiliou
Steinberg-Bernstein Centre for Minimally Invasive Surgery, McGill University Health Centre, Montreal, Canada
3 shared publications- Melina C. Vassiliou
Steinberg-Bernstein Centre for Minimally Invasive Surgery and Innovation, McGill University Health Centre, 1650, Cedar Avenue, L9. 313, Montreal, QC, H3G 1A4, Canada.
3 shared publications Amani Munshi
Steinberg-Bernstein Centre for Minimally Invasive Surgery and Innovation, Department of Surgery, McGill University Health Centre, Montreal, QC, Canada
2 shared publications- Atif Jastaniah
Division of Trauma and General Surgery, Department of Surgery, McGill University, Montreal, QC, Canada
2 shared publications
Latest Publications
- Open Access
- 10 February 2023
- Published by Springer Nature in Canadian Journal of Public Health
- Vol. 114 (2) , 195-206
Factors associated with bicycle helmet use and proper fit: a cross-sectional survey of Montreal cyclists during the COVID-19 pandemic
With increased bicycle use during the COVID-19 pandemic and growing availability of bicycle-sharing programs in Montreal, we hypothesize helmet use has dec
- 10 February 2023
- Published by Springer Nature in Canadian Journal of Public Health
- Vol. 114 (2) , 195-206
Open AccessFactors associated with bicycle helmet use and proper fit: a cross-sectional survey of Montreal cyclists during the COVID-19 pandemic
With increased bicycle use during the COVID-19 pandemic and growing availability of bicycle-sharing programs in Montreal, we hypothesize helmet use has dec
- 21 June 2022
- Published by Springer Nature in Surgical Endoscopy
- Vol. 36 (12) , 9099-9105
Establishing validity evidence for device-assisted advanced laparoscopic suturing tasks using simulation
Background Laparoscopic suturing (LS) is an essential technique required for a wide range of procedures, and it is one of the most challenging for surgical trainees to master. We designed and collected validity evidence for advanced LS tasks using an automated suturing device and evaluated the perceived educational value of the tasks. Methods This project was a multicentre prospective study involving McGill University, University of Toronto (UofT), and Louisiana State University (LSU) Health New Orleans. Novice (NS) and experienced (ES) surgeons performed suturing under tension (UT) and continuous suturing (CS) tasks. ES performed the tasks twice to establish proficiency benchmarks, and they were interviewed to develop formative feedback tools (FFT). Participants were assessed on completion time, error, Global Operative Assessment of Laparoscopic Skills (GOALS), and FFT. Data were analyzed using descriptive and inferential statistical methods. Results Twenty-seven participants (13 ES, 14 NS, median age 34 years; 85% male) completed the study. Eight were attending surgeons, 7 fellows, 4 PGY5, 5 PGY4, and 3 PGY3 (18 from McGill, 5 UofT, and 4 LSU). Comparing ES and NS, for UT task, ES had significantly greater task scores (570 [563–648] vs 323 [130–464], p value 0.00036) and GOALS scores (14 [13–16] vs 10 [8–12], p value 0.0038). Similarly, for CS, ES had significantly greater task scores (976 [959–1010] vs 785 [626–856], p value 0.00009) and GOALS scores (16 [12–17] vs 12.5 [8.25–15], p value 0.028). After FFTs were developed, comparing ES and NS, for both UT and CS tasks, ES had significantly greater FFT scores (UT 25 [24–26] vs 17 [14–20], p value 0.0016 and CS 30 [27–32] vs 22[17.2–25.8], p value 0.00061). Conclusion In conclusion, preliminary validity evidence was provided for the tasks. Once further validity evidence is established, incorporating the tasks into the training curricula could improve trainee skills and help to meet the need for better advanced suturing models.
- 21 June 2022
- Published by Springer Nature in Surgical Endoscopy
- Vol. 36 (12) , 9099-9105
Establishing validity evidence for device-assisted advanced laparoscopic suturing tasks using simulation
Background Laparoscopic suturing (LS) is an essential technique required for a wide range of procedures, and it is one of the most challenging for surgical trainees to master. We designed and collected validity evidence for advanced LS tasks using an automated suturing device and evaluated the perceived educational value of the tasks. Methods This project was a multicentre prospective study involving McGill University, University of Toronto (UofT), and Louisiana State University (LSU) Health New Orleans. Novice (NS) and experienced (ES) surgeons performed suturing under tension (UT) and continuous suturing (CS) tasks. ES performed the tasks twice to establish proficiency benchmarks, and they were interviewed to develop formative feedback tools (FFT). Participants were assessed on completion time, error, Global Operative Assessment of Laparoscopic Skills (GOALS), and FFT. Data were analyzed using descriptive and inferential statistical methods. Results Twenty-seven participants (13 ES, 14 NS, median age 34 years; 85% male) completed the study. Eight were attending surgeons, 7 fellows, 4 PGY5, 5 PGY4, and 3 PGY3 (18 from McGill, 5 UofT, and 4 LSU). Comparing ES and NS, for UT task, ES had significantly greater task scores (570 [563–648] vs 323 [130–464], p value 0.00036) and GOALS scores (14 [13–16] vs 10 [8–12], p value 0.0038). Similarly, for CS, ES had significantly greater task scores (976 [959–1010] vs 785 [626–856], p value 0.00009) and GOALS scores (16 [12–17] vs 12.5 [8.25–15], p value 0.028). After FFTs were developed, comparing ES and NS, for both UT and CS tasks, ES had significantly greater FFT scores (UT 25 [24–26] vs 17 [14–20], p value 0.0016 and CS 30 [27–32] vs 22[17.2–25.8], p value 0.00061). Conclusion In conclusion, preliminary validity evidence was provided for the tasks. Once further validity evidence is established, incorporating the tasks into the training curricula could improve trainee skills and help to meet the need for better advanced suturing models.
- 5 January 2021
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 48 (1) , 315-319
Feasibility of intraoperative angioembolization for trauma patients using C-arm digital subtraction angiography
Purpose Hemodynamically unstable trauma patients who would benefit from angioembolization (AE) typically also require emergent surgery for their injuries. The critical decision of transferring a patient to the operating room versus the interventional radiology (IR) suite can be bypassed with the advent of intra-operative AE (IOAE). Previously limited by the availability of costly rooms termed RAPTOR (resuscitation with angiography, percutaneous techniques and open repair) suites, it has been suggested that using C-arm digital subtraction angiography (DSA) is a comparable alternative. This case series aims to establish the feasibility and safety of IOAE. Methods We conducted a retrospective analysis of all trauma patients at our level 1 trauma center who underwent IOAE with a concomitant surgical intervention from January 2011 to May 2019. Descriptive analyses were conducted. Results A total of 49 patients (80% male, 44 ± 17 years, 92% blunt) underwent IOAE using the C-arm DSA during the study period. All but one patient underwent exploratory laparotomy, 56% of which underwent an additional surgical procedure (ex. exploratory thoracotomy, orthopedic). Either Gelfoam® (Pfizer, New York, USA) (90%), coils (2.0%), or a combination (8.2%) were used for embolization. Internal iliac embolization was performed in 88% of cases (59% bilateral). IOAE was successful in all but four cases (8.2%) and thirty-day mortality was 31%. Conclusion IOAE appears to be a feasible and safe management option in severe trauma patients with the advantage of concurrent operative intervention and ongoing active resuscitation with good success in hemorrhage control.
- 5 January 2021
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 48 (1) , 315-319
Feasibility of intraoperative angioembolization for trauma patients using C-arm digital subtraction angiography
Purpose Hemodynamically unstable trauma patients who would benefit from angioembolization (AE) typically also require emergent surgery for their injuries. The critical decision of transferring a patient to the operating room versus the interventional radiology (IR) suite can be bypassed with the advent of intra-operative AE (IOAE). Previously limited by the availability of costly rooms termed RAPTOR (resuscitation with angiography, percutaneous techniques and open repair) suites, it has been suggested that using C-arm digital subtraction angiography (DSA) is a comparable alternative. This case series aims to establish the feasibility and safety of IOAE. Methods We conducted a retrospective analysis of all trauma patients at our level 1 trauma center who underwent IOAE with a concomitant surgical intervention from January 2011 to May 2019. Descriptive analyses were conducted. Results A total of 49 patients (80% male, 44 ± 17 years, 92% blunt) underwent IOAE using the C-arm DSA during the study period. All but one patient underwent exploratory laparotomy, 56% of which underwent an additional surgical procedure (ex. exploratory thoracotomy, orthopedic). Either Gelfoam® (Pfizer, New York, USA) (90%), coils (2.0%), or a combination (8.2%) were used for embolization. Internal iliac embolization was performed in 88% of cases (59% bilateral). IOAE was successful in all but four cases (8.2%) and thirty-day mortality was 31%. Conclusion IOAE appears to be a feasible and safe management option in severe trauma patients with the advantage of concurrent operative intervention and ongoing active resuscitation with good success in hemorrhage control.
- Open Access
- 17 January 2019
- Published by Springer Nature in Canadian Journal of Emergency Medicine
- Vol. 21 (3) , 430-434
In the Zone: lessons from the first Canadian emergency department application of resuscitative endovascular balloon occlusion of the aorta (REBOA)
- 17 January 2019
- Published by Springer Nature in Canadian Journal of Emergency Medicine
- Vol. 21 (3) , 430-434
Open AccessIn the Zone: lessons from the first Canadian emergency department application of resuscitative endovascular balloon occlusion of the aorta (REBOA)
- 1 July 2017
- Published by Elsevier in The American Journal of Surgery
- Vol. 214 (1) , 117-126
Perioperative feedback in surgical training: A systematic review
- 1 July 2017
- Published by Elsevier in The American Journal of Surgery
- Vol. 214 (1) , 117-126
Perioperative feedback in surgical training: A systematic review
- 25 April 2017
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31 (12) , 5057-5065
Establishing meaningful benchmarks: the development of a formative feedback tool for advanced laparoscopic suturing
Time and accuracy are commonly used metrics to assess laparoscopic skills in a simulated environment. However, they do not provide trainees with meaningful information about how to improve their skills. The objective of this study was to provide preliminary validity evidence for the creation a formative feedback tool (FFT) for advanced laparoscopic suturing skills.
- 25 April 2017
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31 (12) , 5057-5065
Establishing meaningful benchmarks: the development of a formative feedback tool for advanced laparoscopic suturing
Time and accuracy are commonly used metrics to assess laparoscopic skills in a simulated environment. However, they do not provide trainees with meaningful information about how to improve their skills. The objective of this study was to provide preliminary validity evidence for the creation a formative feedback tool (FFT) for advanced laparoscopic suturing skills.
- 30 April 2016
- Published by Elsevier in Journal of Surgical Education
- Vol. 73 (4) , 559-566
A Learner-Created Virtual Patient Curriculum for Surgical Residents: Successes and Failures
- 30 April 2016
- Published by Elsevier in Journal of Surgical Education
- Vol. 73 (4) , 559-566
A Learner-Created Virtual Patient Curriculum for Surgical Residents: Successes and Failures
- 1 February 2016
- Published by Elsevier in The American Journal of Surgery
- Vol. 211 (2) , 426-430
Reliable assessment of operative performance
- 1 February 2016
- Published by Elsevier in The American Journal of Surgery
- Vol. 211 (2) , 426-430
Reliable assessment of operative performance
- 28 May 2015
- Published by Springer Nature in Surgical Endoscopy
- Vol. 30 (2) , 581-587
New models for advanced laparoscopic suturing: taking it to the next level
Current simulations for laparoscopic suturing do not reflect the complexity of the skills required in the operating room. The purpose of this study was to develop three novel advanced suturing tasks with assessment metrics and to collect validity evidence for their measures of suturing skill. We developed three tasks based on training gaps identified through a previous needs assessment: needle handling (NH), suturing under tension (UT), and continuous suturing (CS). Minimally invasive surgeons (MIS) and senior surgical residents (SR) completed these tasks and a questionnaire regarding their educational value. Performance was assessed by two raters based on time and accuracy. Validity was assessed by comparing performance according to the level of training and self-reported experience. The inter-rater reliability and internal consistency of the tasks were calculated. Thirty-one subjects (13 MIS, 18 SR) were enrolled in the study (median age 32; 77 % male). Compared to the SR group, the MIS group had significantly greater scores on all tasks. While all MIS surgeons completed the three tasks within the allotted time, six (33 %) residents could not complete at least one out of the three tasks. Laparoscopic suturing experience correlated positively with the scores of all tasks (NH 0.51, UT 0.70, CS 0.65. p < 0.01). Inter-rater reliability for all tasks was 0.99, and internal consistency was 0.80. The majority of participants agreed that the tasks were relevant to practice, helped improve technical competence, and adequately measured suturing ability. This study provides validity evidence for three novel advanced laparoscopic suturing tasks. Performance on all tasks correlated significantly with training level and self-reported experience. Integrating these tasks into educational curricula may help improve residents’ suturing skills and better prepare residents for the operating room.
- 28 May 2015
- Published by Springer Nature in Surgical Endoscopy
- Vol. 30 (2) , 581-587
New models for advanced laparoscopic suturing: taking it to the next level
Current simulations for laparoscopic suturing do not reflect the complexity of the skills required in the operating room. The purpose of this study was to develop three novel advanced suturing tasks with assessment metrics and to collect validity evidence for their measures of suturing skill. We developed three tasks based on training gaps identified through a previous needs assessment: needle handling (NH), suturing under tension (UT), and continuous suturing (CS). Minimally invasive surgeons (MIS) and senior surgical residents (SR) completed these tasks and a questionnaire regarding their educational value. Performance was assessed by two raters based on time and accuracy. Validity was assessed by comparing performance according to the level of training and self-reported experience. The inter-rater reliability and internal consistency of the tasks were calculated. Thirty-one subjects (13 MIS, 18 SR) were enrolled in the study (median age 32; 77 % male). Compared to the SR group, the MIS group had significantly greater scores on all tasks. While all MIS surgeons completed the three tasks within the allotted time, six (33 %) residents could not complete at least one out of the three tasks. Laparoscopic suturing experience correlated positively with the scores of all tasks (NH 0.51, UT 0.70, CS 0.65. p < 0.01). Inter-rater reliability for all tasks was 0.99, and internal consistency was 0.80. The majority of participants agreed that the tasks were relevant to practice, helped improve technical competence, and adequately measured suturing ability. This study provides validity evidence for three novel advanced laparoscopic suturing tasks. Performance on all tasks correlated significantly with training level and self-reported experience. Integrating these tasks into educational curricula may help improve residents’ suturing skills and better prepare residents for the operating room.