RKRobab Kazemi

Robab Kazemi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Robab Kazemi has a total of 44 co-authors. Here are the top co-authors by number of shared publications:

  • Aly E. Fathy

    Department of Electrical Engineering and Computer Science, University of Tennessee, Knoxville, USA

    16 shared publications
  • Aly Fathy

    Department of Electrical Eng. and Computer Science, University of Tennessee, Knoxville, US

    4 shared publications
  • R. Ali Sadeghzadeh

    Faculty of Electrical and Computer Engineering, K.N. Toosi University of Technology, Tehran, Iran

    4 shared publications
  • Aly E. Fathy

    The University of Tennessee,Department of Electrical Engineering and Computer Science,Knoxville,Tennessee,USA

    3 shared publications
  • Aslan Nouri Moqadam

    Faculty of Electrical and Computer Engineering, University of Tabriz, Tabriz, Iran

    3 shared publications
  • Yun Seo Koo

    Department of Electrical Engineering and Computer Science, University of Tennessee, Knoxville, TN, USA

    3 shared publications

Latest Publications

  • Open Access

    Design of a Compact Slot Antenna Array for Hyperthermia Treatment in Noncentral Breast Cancer Therapy

    by Zahra Hemmati, Robab Kazemi

    This paper presents a compact conformal antenna for breast cancer hyperthermia treatment. The design integrates two rectangular patches within a slot and a fork‐shaped feedline, achieving over 50% bandwidth. Its conformal geometry adapts to tissue contours, improving treatment efficiency. To optimize electromagnetic (EM) power delivery to tumors while reducing undesired back radiation toward the operator, the design incorporates a hemispherical reflector and a neoprene layer at the back of the antenna for effective reflection and absorption. Additionally, a water bolus is utilized between the antenna and the skin to prevent hotspot formation. Operating at 2.45 GHz, the antenna measures 18 × 12 mm (0.15 λ 0 × 0.1 λ 0 ), making it over 50% smaller than conventional patch antennas, and maintains stable performance despite tissue property variations. The antenna effectively targets deep‐seated tumors while minimizing skin heating. Its compactness supports array configurations for improved penetration and off‐center tumor targeting through phase control. Performance evaluation of single and multielement arrays—considering reflection coefficient, SAR, penetration depth (PD), effective field size (EFS), and time–temperature response—shows that the single element achieves a PD of 21.15 mm and EFS of ∼119 mm 2 . Arrays with 3, 5, and 7 elements further enhance PD and EFS, confirming the antenna’s potential for efficient, localized, and safe hyperthermia therapy. By applying appropriate phase differences between array elements, tumors located up to 50° from the tissue center can be effectively treated without repositioning the applicator or patient.

  • Open Access

    Design and Implementation of a Compact Dual‐Band MIMO Antenna Module With Enhanced Bandwidth and Isolation

    by Hamed Hamlbar Gerami, Robab Kazemi, Aly E. Fathy

    In this paper, a compact dual‐band antenna module has been developed, achieving significant isolation between the ports. The design integrates an open‐edge slot antenna for the lower frequency band (5.15–7.1 GHz) with a 1 × 2 MIMO metasurface antenna for the mmWave frequency range (24.5–29.5 GHz), resulting in a high‐performance, compact dual‐band solution. The slot antenna is optimized for a reduced size configuration with enhanced bandwidth for lower frequencies, while the metasurface antenna delivers wider bandwidth and stable performance in the mmWave range with minimal mutual coupling and high efficiency. This makes the overall design highly effective for modern compact dual‐band applications. The dual‐band antenna module has dimensions of 20 × 16.5 × 0.99 mm (0.39 λ 0 × 0.32 λ 0 × 0.01 λ 0 , where λ 0 represents the free‐space wavelength at 5.85 GHz). It achieves a measured peak gain of 3.8 dB for the lower band and 8.81 dB for the mmWave band. Additionally, the output of the mmWave antennas can be combined for higher gain or used in a MIMO configuration, enhancing channel capacity and communication reliability, which are critical for modern wireless systems.


  • Open Access

    Development of a compact metasurface antenna with reconfigurable pattern through mode combination technique for 5G mm‐wave applications

    by Hamed Hamlbar Gerami, Robab Kazemi

    This paper presents a compact metasurface antenna with reconfigurable radiation patterns designed for 5G mm‐wave applications. The antenna consists of a metasurface with 3 × 3 unit cells of modified patches, two coupling slots on the ground plane, and a reconfigurable feeding network. The method of characteristic mode analysis is initially employed to identify the modes of the metasurface layer which are responsible for steering the radiation pattern of the antenna at angles of 0° and ±30°. By analysing the surface currents of these modes, the locations of the coupling slots are determined, making it easier to excite and combine the desired modes and steer the main beam of the antenna in specific directions. The pattern reconfigurability is achieved by switching PIN diodes in the microstrip feed network to excite the appropriate coupling slots. The proposed metasurface antenna, with dimensions of 0.9 λ 0 × 0.9 λ 0 × 0.08 λ 0 (where λ 0 is the free space wavelength at the centre frequency of 27 GHz), was fabricated and tested. The experimental results showed a wide bandwidth of 22.71% achieved by combining the resonance frequencies of the slots and metasurface layer. Furthermore, the antenna exhibits three distinct main beams at +30°, 0°, and −30° with a peak gain of 8.95 dB.


  • Open Access

    Optimizing Isolation in Interleaved Co-Frequency Orthogonally Polarized Circular Patch Array Antennas Using Conformal Mantle Cloaks and Integrated Decoupling Patches

    by Reza Masoumi, Robab Kazemi, Aly E. Fathy

    Employing two closely spaced arrays operating at the same frequency with orthogonal polarizations and independent operations present significant potential for miniaturizing telecommunication systems. This paper presents two interleaved, tightly spaced circular patch array antennas that operate at the same frequency but with orthogonal polarizations. The arrays are arranged in the E-plane, with one array rotated 90 degrees to achieve orthogonal polarization―Array-I is x-polarized, while Array-II is y-polarized. This configuration provides both spatial and polarization diversity, which helps reduce signal degradation caused by multipath fading and enhances overall channel capacity. However, the inherent symmetry of the circular patches typically results in significant coupling between adjacent arrays when they are closely spaced, which can severely degrade antenna performance. In this study, we investigate the effectiveness of conformal mantle cloaks and decoupling patches in isolating two interleaved co-frequency circular patch array antennas. Our designed mantle cloak, composed of a conformal substrate with parallel metallic strips, successfully eliminates cross-coupling between adjacent elements in the interleaved arrays, although it does not fully mitigate inter-element coupling within each array. To further address this issue, we employ small patches with shorting pins to minimize mutual coupling among the elements of each array. These isolating techniques enable minimal proximity between the arrays, achieving a center-to-center spacing of 28.88 mm (0.54λ0) and an edge-to-edge gap of less than 1 mm (λ0/50), theoretically approaching zero at the resonant frequency of 5.6 GHz. The conformal substrate of the cloak, produced using 3D printing technology, simplifies the fabrication process by covering only the top surface of the patches. The proposed design has been successfully fabricated and evaluated using detailed comparison metrics, including return loss, mutual coupling, radiation patterns, gain, and efficiency across cloaked and uncloaked configurations. The simulation and experimental results closely match, confirming that the cloaked antennas exhibit similar radiation performance to isolated elements.


  • Open Access

    Development of a metasurface-based slot antenna for 5G MIMO applications with minimized cross-polarization and stable radiation patterns through mode manipulation

    by Hamed Hamlbar Gerami, Robab Kazemi, Aly E. Fathy

    This paper presents an approach for designing metasurface antennas using the characteristic mode analysis method for 5G mm-wave multiple input–multiple output (MIMO) systems. The proposed metasurface antenna consists of a 3 × 3 array of modified patches with additional slits and stubs, which are fed by a coupling slot. This configuration reshapes surface currents and improves the radiation performance across a broad frequency range. The design offers significant advantages such as reduced antenna size, minimized influence of higher-order modes, and maintained low cross-polarization (XP) level. Experimental results demonstrate that the proposed metasurface-based slot antenna provides a bandwidth of 29.6% (23–31 GHz) with a return loss better than 10 dB. It achieves a peak gain of 9.43 dB and exhibits an XP level below − 26 dB and − 48 dB at $$\varphi = 0^{ \circ }$$ φ = 0 ∘ and $$\varphi = 90^{ \circ }$$ φ = 90 ∘ planes, respectively. The physical dimensions of the antenna are 0.9λ0 × 0.9λ0 × 0.08λ0, where λ0 is the free space wavelength at 27 GHz, resulting in an approximately 41% reduction compared to the conventional metasurface patch antenna. Moreover, the design proves to be well-suited for MIMO systems, enabling close placement of antenna elements without degrading their radiation patterns. The experimental results in 1 × 2 and 2 × 2 MIMO configurations represent that the isolation between antenna elements are better than 18 dB and 21 dB, respectively. The performance of the antennas remains stable in both configurations, effectively addressing concerns such as beam squint and eliminating the common issue of beam splitting observed in conventional metasurface MIMO antennas. Moreover, the envelope correlation coefficient value in both MIMO configurations is lower than 0.003. This significant advancement offers a promising solution for compact 5G mm-wave massive MIMO applications.


  • Radial Power Combiners—An Overview: A Comprehensive Analysis of Power Combiners, Their Structures and Evolution From Their Inception to the Present

    by Robab Kazemi, Aly E. Fathy

    The demand for progressively higher microwave power levels is growing fast. In the past, traveling-wave tubes (TWTs) played a key role in constructing a wide range of microwave systems for various applications, such as radars, satellites, and wireless communication links. However, their poor resilience to degradation significantly affects system reliability. Meanwhile, TWT amplifiers (TWTAs) are expensive, bulky, and require a considerable warm-up time and high-dc voltage levels, especially in low-frequency bands [1] , [2] .


  • High-Resolution Imaging of Narrow Bone Fractures With a Novel Microwave Transceiver Sensor Utilizing Dual-Polarized RIS and SRR Array Antennas

    by Aslan Nouri Moqadam, Robab Kazemi

    In this study, a new transceiver system is presented for detecting the location and orientation of narrow bone fractures. The system comprises a multilayer patch resonator integrated with a reactive impedance surface as the transmitter, and a 3-element array of SRR probes as the receiver. It operates at 2.45 GHz in the ISM frequency band. Dielectric plano-concave lenses are used in the transmitter and receiver to improve impedance matching and adapt to the human body curvature. By using three adjacent SRR probes to divide the area being investigated into smaller sections, the system concentrates power in the fractured region, improving image resolution. The high capacitance of the split gap in the SRR probes allows for precise tracking of small changes. The system performs longitudinal and rotational raster scans to localize bone cracks, and achieves an impressive resolution of 1 mm. Experimental measurements were conducted using a gelatin-based arm phantom and a real arm with various healthy and broken bones. The dual-polarized configuration of the system enables effectively detecting the orientation of fractures. The presence of fractures can be determined by comparing the power received from the three SRR probes. When the crack is parallel to the incident E-field, the probe directly facing the crack receives more power than the adjacent probes. This power difference is significantly reduced in healthy bone and also when the incident wave is perpendicular to the crack. The results from both measurement and simulation support each other, validating the reliability of the proposed transceiver system.


  • Open Access

    Development of a Broadband and High-Gain Circularly Polarized Array of Multilayer Slot Antennas for X-Band Wireless Communication Networks

    by Hosein Saghafi, Robab Kazemi, Hamed Hamlbar Gerami

    This paper presents a wideband cavity-backed slot antenna array designed for X-band wireless communication systems. The antenna element consists of a circular slot combined with a cross-slotted patch; both are fed by an L-shaped microstrip line through proximity coupling to extend the impedance bandwidth and gain. The reduction of beam squint in the radiation patterns, caused by the asymmetric feed line, is achieved through intelligent optimization of the dimensions and position of the cross slot on the patch. Additionally, a back cavity is included to provide unidirectional radiation and enhance gain. The antenna exhibits right-hand circularly polarized (RHCP) radiation patterns with high gain over a wideband frequency range. To further improve the axial ratio (AR) bandwidth and gain, the antenna is utilized in a array configuration with a sequential rotation feed network. The overall dimensions of the proposed array are , where represents the wavelength at the center frequency of 10 GHz. The fabricated array is then tested, and the measurements show an impedance bandwidth of 60% (7 GHz-13 GHz) with dB, a 3 dB AR bandwidth of 42% (7.45-11.65 GHz), and a peak gain of 11.14 dB. The simulated and measured results exhibit good agreement, validating the effectiveness of the design.


  • Open Access

    Design of a novel dual-polarized microwave sensor for human bone fracture detection using reactive impedance surfaces

    by Aslan Nouri Moqadam, Robab Kazemi

    This paper presents a novel miniaturized dual-polarized transceiver sensor system for detecting fractures in human bone tissues. The system features a patch antenna and a Reactive Impedance Surface (RIS) layer that reduces its size by 30% compared to conventional designs, resulting in enhanced fracture detection accuracy. Additionally, the system includes a dielectric plano-concave lens that adapts to the human body and improves impedance matching for optimal performance. The lens contains via holes filled with a lossy dielectric material similar to human fat tissue, which concentrates electromagnetic (EM) power and increases penetration depth for more effective crack detection. To detect fractures, two identical sensors are placed opposite each other on the tissue and moved simultaneously. The amount of EM power collected by the receiver sensor is measured using S-parameters; the transmission coefficient (S21) phases and contrast between the crack and surrounding tissue are used to construct images of fractured bones. Full-wave simulations and experimental measurements on a semi-solid human arm mimicking phantom demonstrate the proposed dual-polarized sensor's ability to detect the location and orientation of narrow cracks in the millimeter range. The system exhibits reliable performance across different human bodies.


  • Open Access

    Design and implementation of elliptical mantle cloaks for polarization decoupling of two tightly spaced interleaved co-frequency patch array antennas

    by Reza Masoumi, Robab Kazemi, Aly E. Fathy

    In this paper, we utilized the method of mantle cloaking to decouple/isolate two densely packed interleaved patch array antennas operating at the same frequency but with orthogonal polarizations. To reduce mutual coupling between the adjacent elements, vertical strips, as a type of elliptical mantle cloaks, are located in close proximity to the patches. At the operating frequency of f0 = 3.7 GHz, the edge-to-edge spacing of the elements of the two interleaved arrays is less than λ0/80 (1 mm) and the center-to-center spacing of each array element is 0.7 λ0 (57 mm). The proposed design is implemented using 3D printing technology, and its performance in terms of return loss, efficiency, gain, radiation patterns, and isolation is measured for evaluation. The results show the radiation characteristics of the arrays are perfectly retrieved after cloaking similar to the isolated arrays. Decoupling tightly spaced patch antenna arrays on a single substrate paves the way to achieve miniaturized communication systems with full duplex operation or dual polarization communication.