JKJong-Pil Kim

Jong-Pil Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jong-Pil Kim has a total of 73 co-authors. Here are the top co-authors by number of shared publications:

  • Won-Jeong Shin

    Hand & Upper Extremity Center, Naeun Pil Hospital, Cheonan, Korea

    4 shared publications
  • Joong Bae Seo

    Departments of Orthopedic Surgery and Department of Kinesiology and Medical Science Dankook University College of Medicine Cheonan Republic of Korea

    3 shared publications
  • Kwang-Hee Park

    Department of Orthopaedic Surgery, Dankook University College of Medicine, Cheonan, Korea

    3 shared publications
  • Jae-Sung Yoo

    Department of Orthopedic Surgery, Dankook University Hospital, 201 MangHyang-ro, Dongnam-gu, Cheonan 31116, Republic of Korea

    2 shared publications
  • Jae-Uk Jung

    Department of Orthopedic Surgery, Dankook University College of Medicine, Cheonan, Korea

    2 shared publications
  • Jai-Hyang Go

    Department of Pathology, Dankook University College of Medicine, Cheonan, Korea

    2 shared publications

Latest Publications

  • Open Access

    Comparison of ulnar shortening osteotomy for idiopathic ulnar impaction syndrome using conventional or ulnar osteotomy plates and with or without interfragmentary screw fixation

    by Kyung Wook Kim, Ju Hyun Kim, Jeong Sang Kim, Bum Jin Shin, Jong Pil Kim

    Purpose This study investigated the impact of plate type on the clinical and radiological outcomes of ulnar shortening osteotomy (USO) by comparing conventional and ulnar osteotomy plates. The effect of interfragmentary screw fixation (ISF) during USO was also assessed.Methods Seventy-eight patients were divided into three groups according to the type of plate: 3.5-mm dynamic compression plate (DCP), 3.5-mm limited contact DCP, and 2.7-mm locking compression plate ulna osteotomy system (all from Depuy-Synthes). The patients were also divided into two groups according to whether ISF was performed. Clinical and radiological outcomes, including time to bone union, presence of delayed union, and refracture after hardware removal, were analyzed. Other factors that might affect bone union, such as smoking and underlying diseases, were also evaluated.Results No significant differences were found in clinical and radiological outcomes according to the type of plate. Eight of 51 patients (15.7%) in the without-ISF group showed delayed bone union. Forty-three patients in the without-ISF group underwent hardware removal, and refracture due to low-energy trauma after hardware removal was observed in five of those 43 patients (11.6%). Bone union time was significantly shorter in the with-ISF group (7.6±2.7 weeks vs. 9.8±6.6 weeks). Diabetes mellitus and ISF were associated with the delayed bone union.Conclusion The plate type had no influence on the clinical and radiological outcomes of USO in patients with idiopathic ulnar impaction syndrome. However, ISF during USO has several advantages, such as early bony union and prevention of refracture after hardware removal.

  • Open Access

    Topographic and Histologic Analysis of the Collateral Ligament Complex around the Elbow

    by Jong-Pil Kim, Ji-Kang Park, Joon-Young Yoo, Won-Jeong Shin, Jeong-Sang Kim, Young-Il Kim

    Purpose: The purpose of this study was to evaluate topographic anatomy of the footprints of key ligaments of the elbow and assess their relationships with bony parameters using micro-computed tomography (micro-CT). Additionally, the ratios of type I/III collagen at the medial collateral ligament (MCL) and lateral collateral ligament (LCL) of elbow were investigated.Methods: Eleven cadaveric elbows attached by both the MCL and LCL were scanned using micro-CT and reconstructed three-dimensionally. Additionally, the ligaments were examined under polarized light microscopy to determine the histological characteristics of collagen patterns. Results: Areas of footprints of the MCL and LCL attaching onto the humerus were 133.2±25.8 mm² and 128.3±23.2 mm², respectively. Footprint sizes of anterior and posterior bundles of the MCL in the proximal ulna and lateral ulnar collateral ligament (LUCL) attaching to the proximal ulna averaged to 109.9 mm², 89.2 mm², and 89.7 mm², respectively. There were a positive correlation between footprint size of the MCL and LUCL at the humeral side and a negative correlation between the footprint size of the MCL at humeral side and maximal diameter of the radial head. The collagen I/III ratio of the humeral attachment of the MCL was higher than distal attachment of the MCL. Conclusion: This study provides a better understanding of the pathologies of the MCL and LCL complex of the elbow and their relationships with osseous anatomy and may assist the clinician with an anatomic reconstruction of the ligaments.

  • Evaluation of the Use of a Molybdenum Filter for Dose Reduction in Pediatric Digital X-ray Imaging

    by Su-Jin Park, Jae Hyuk Kim, Jong Chul Han, Jungha Kim, Jungmin Kim, Jong-Pil Kim, Minkook Cho, Jung Ho Kim

    Pediatric dosimetry requires extra attention as young children are three times more sensitive to radiation than the average population. Soft tissues of patients absorb low-energy photons without affecting useful diagnostic information. X-ray filters can decrease the exposure dose of radiation by removing low-energy photons from the X-ray beam. Several studies have dealt with the advantages of a conventional filter, copper (Cu), in pediatric digital X-ray radiography. Only a few studies, however, have examined the use of molybdenum (Mo) filters and their impact on the radiation dose and image quality in pediatric digital X-ray imaging. In this study, we investigated the impact of a Mo filter on the image quality and the entrance surface exposure (ESE) in pediatric X-ray imaging and assessed the potential of additional dose reduction compared to a conventional Cu filter. The performance of the Mo filter was investigated and compared with that of Cu filter. Two types of phantoms were used: a customized quantitative phantom (Phantom A) for quantitative comparison and a computational anthropomorphic extended cardiac-torso (XCAT) phantom for qualitative comparison. A clinical radiography system was modeled, and the clinical setting for pediatric chest X-ray imaging was considered. Geant4 simulations using Monte Carlo toolkits were performed to obtain the images for pediatric chest X-ray examinations. Quantitative and qualitative comparisons using the quantitative phantom (Phantom A) and the XCAT phantom, respectively, were performed for both filters. From the customized quantitative phantom study, the ESE for the Mo filter was compared with that for the Cu filter when contrast-to-noise ratio (CNR) was equal. In addition, to validate our Monte Carlo model, we compared simulated and experimentally acquired images. From the results, the ESE for the Cu filter was 22.62 μGy while the ESE for the Mo filter was 18.18 μGy for 5-mm soft tissue. The use of a Mo filter results in a reduction in the dose by 19.60%. From the XCAT phantom study, the image for the Mo filter was superior to that for Cu filter in terms of noise and recognition of blood vessels. The performance characteristics of the Mo filter were evaluated in terms of image quality and radiation dose by comparing those characteristics to the ones for a conventional Cu filter. Our results demonstrated that the use of the Mo filter can significantly reduce the radiation dose. Based on this result, Mo filters are recommended for use in pediatric digital X-ray imaging.


  • Open Access

    Efficiency of magnetic resonance imaging for diagnosing unstable ligament injuries around the thumb metacarpophalangeal joint: A comparison to arthroscopy

    by Yong-Eun Shin, Sung-Joon Kim, Jeong-Sang Kim, Kwon-Young Kwak, Ji-Hyo Kim, Jong-Pil Kim

    Purpose: This study aimed to assess the accuracy of MRI in identifying ulnar collateral ligament (UCL), radial collateral ligament (RCL), and volar plate (VP) injuries of the metacarpophalangeal joint (MCPJ) of the thumb by comparing with diagnostic arthroscopy. Methods: A total of 56 consecutive patients (56 thumbs) who underwent arthroscopy of MCPJ of thumb were enrolled. MRI findings reviewed by consensus reading of two blinded radiologists were compared with arthroscopic examination. Statistical data, including sensitivity, specificity, accuracy, were analyzed. Additionally, the performance characteristics between 3.0-tesla (39 thumbs) and 1.5-tesla (17 thumbs) MRI and acute (≤4 weeks after injury) and chronic (>4 weeks) injuries were compared. Results: Of the 56 thumbs, 38 thumbs (67.9%) showed complete correspondence between MRI and arthroscopic findings. The sensitivity, specificity and accuracy of MRI for detecting UCL injuries were 78.8%, 87.0%, and 82.1%, respectively. The sensitivity, specificity and accuracy of MRI for detecting RCL injuries were 85.7%, 91.4%, and 85.7%, respectively. The sensitivity, specificity, and accuracy of MRI for detecting VP injuries were 89.5%, 89.2%, and 81.0%, respectively. 3.0-tesla MRI showed higher correspondence with arthroscopic observation (76.9%) than 1.5-tesla MRI (47.1%) (p = 0.028). For acute injuries, 78.4% showed complete correspondence between MRI and arthroscopic findings, whereas 47.4% with chronic injuries revealed complete agreement (p = 0.019). Conclusion: Overall, MRI is moderately effective in evaluating ligamentous lesions around MCPJ of thumb, but MRI is more sensitive in diagnosing acute injuries. Furthermore, 3.0-tesla MRI can provide results with better accuracy for diagnosing ligamentous lesions around MCPJ of thumb. However, the sensitivity and the specificity are not applicable to all ligament injuries, but only the severe one which would agree for surgical options.


  • Motor Loss

    by Jong-Pil Kim, Jae-Sung Yoo

  • Open Access

    The Effect of Cryopreservation of Allograft Nerve on the Recovery of Motor Function

    by Seung-Sik Choi, Ilyong Park, Jung Keun Hyun, Jae-Uk Jung, Jong-Pil Kim

    Choi SS, et al. Arch Hand Microsurg. 2019 Sep;24(3):273-284. https://doi.org/10.12790/ahm.2019.24.3.273


  • Open Access

    Spontaneous Rupture of the Extensor Pollicis Longus Tendon in a Rhythm Gamer: A Case Report

    by Seokwon Yang, Sung-Hyun Yoon, Sung-Hyun Kim, Soon-Min Kwon, Jong-Pil Kim

    Yang S, et al. Arch Hand Microsurg. 2019 Mar;24(1):63-67. https://doi.org/10.12790/ahm.2019.24.1.63


  • Open Access

    Hand Fractures

    by Seokwon Yang, Jong-Pil Kim

    Yang S, et al. J Korean Fract Soc. 2018 Apr;31(2):61-70. https://doi.org/10.12671/jkfs.2018.31.2.61