Kevin Clesham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kevin Clesham has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Eoin Sheehan
Trauma and Orthopaedic Surgery, Midland Regional Hospital Tullamore, Tullamore, Offaly, Ireland
3 shared publications- Andrew Jerome Hughes
Adult Reconstruction and Joint Replacement Service Hospital for Special Surgery New York City New York USA
2 shared publications - Colin Gerard Murphy
University Hospital Galway, Galway, Ireland
2 shared publications Ahmed Karkuri
Department of Orthopaedic & Trauma Surgery, Sligo University Hospital, Sligo, Ireland
1 shared publication- Ailbhe White-Gibson
Department Trauma & Orthopaedics, Tallaght University Hospital, Dublin, Ireland
1 shared publication Andrew Hughes
Department of Orthopaedic Surgery, Midlands Regional Hospital Tullamore, Co. Offaly, Ireland
1 shared publication
Latest Publications
- Open Access
- 26 May 2025
- Published by Elsevier in The Surgeon
- Vol. 23 (6) , 359-364
The impact of direct consultant-to-consultant referrals on the spinal care pathway: A clinical audit
- 26 May 2025
- Published by Elsevier in The Surgeon
- Vol. 23 (6) , 359-364
Open AccessThe impact of direct consultant-to-consultant referrals on the spinal care pathway: A clinical audit
- Open Access
- 4 January 2023
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 57 (4) , 176-182
Pronator quadratus repair after volar plating for distal radius fractures: A systematic review and meta-analysis of randomized controlled trials
Objective: The purpose of the current study is to meta-analyze the randomized controlled trials in the literature comparing pronator quadratus repair versus no repair alongside volar plating of distal radius fractures. Methods: A search of the PUBMED/MEDLINE, EMBASE, and The Cochrane Library databases was performed. Any randomized con- trolled trials comparing pronator quadratus repair versus no repair alongside volar plating of distal radius fractures were included. The relevant information was collected by 2 blinded reviewers using a predetermined data sheet. Clinical outcomes were compared, with all statistical analyses performed using Review Manager Version 5.3. Results: Five randomized controlled trials with 273 patients were included. There was no significant difference in the range of motion in flexion-extension, ulnar-radial deviation, or pronation-supination. There was a significant difference in favor of the no repair group for Disabilities of the Arm, Shoulder and Hand (DASH) Score (MD [Mean Difference]: 2.63, P < .0001) and pronation strength (MD: 13, P < .0001). Furthermore, there was no significant difference in the visual analog scale score. There were 3 complications relating to pronator quadratus repair, in which patients developed carpal tunnel syndrome requiring a release. There was no significant difference in the re-operation rate. Conclusion: This study found that pronator quadratus repair when performing volar plating for distal radius fractures did not result in a significant improvement in functional outcome, range of motion, or strength. Level of Evidence: I, Systematic Review of Level 1 Studies, Level I, Therapeutic Study Cite this article as: Turley LP, Hurley ET, White-Gibson A, Clesham K, Lyons F. Pronator quadratus repair after volar plating for distal radius fractures: A systematic review and meta-analysis of randomized controlled trials. Acta Orthop Traumatol Turc., 2023;57(4):176-182.
- 4 January 2023
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 57 (4) , 176-182
Open AccessPronator quadratus repair after volar plating for distal radius fractures: A systematic review and meta-analysis of randomized controlled trials
Objective: The purpose of the current study is to meta-analyze the randomized controlled trials in the literature comparing pronator quadratus repair versus no repair alongside volar plating of distal radius fractures. Methods: A search of the PUBMED/MEDLINE, EMBASE, and The Cochrane Library databases was performed. Any randomized con- trolled trials comparing pronator quadratus repair versus no repair alongside volar plating of distal radius fractures were included. The relevant information was collected by 2 blinded reviewers using a predetermined data sheet. Clinical outcomes were compared, with all statistical analyses performed using Review Manager Version 5.3. Results: Five randomized controlled trials with 273 patients were included. There was no significant difference in the range of motion in flexion-extension, ulnar-radial deviation, or pronation-supination. There was a significant difference in favor of the no repair group for Disabilities of the Arm, Shoulder and Hand (DASH) Score (MD [Mean Difference]: 2.63, P < .0001) and pronation strength (MD: 13, P < .0001). Furthermore, there was no significant difference in the visual analog scale score. There were 3 complications relating to pronator quadratus repair, in which patients developed carpal tunnel syndrome requiring a release. There was no significant difference in the re-operation rate. Conclusion: This study found that pronator quadratus repair when performing volar plating for distal radius fractures did not result in a significant improvement in functional outcome, range of motion, or strength. Level of Evidence: I, Systematic Review of Level 1 Studies, Level I, Therapeutic Study Cite this article as: Turley LP, Hurley ET, White-Gibson A, Clesham K, Lyons F. Pronator quadratus repair after volar plating for distal radius fractures: A systematic review and meta-analysis of randomized controlled trials. Acta Orthop Traumatol Turc., 2023;57(4):176-182.
- 1 October 2021
- Published by Elsevier in The Surgeon
- Vol. 19 (5) , e217-e221
Challenges faced by orthopaedic trainees during the Covid-19 pandemic – An Irish perspective
- 1 October 2021
- Published by Elsevier in The Surgeon
- Vol. 19 (5) , e217-e221
Challenges faced by orthopaedic trainees during the Covid-19 pandemic – An Irish perspective
- 4 February 2021
- Published by Springer Nature in SN Comprehensive Clinical Medicine
- Vol. 3 (2) , 654-658
The Clinical Significance of Full Blood Count Day 1 Post-op After Total Joint Arthroplasty
- 4 February 2021
- Published by Springer Nature in SN Comprehensive Clinical Medicine
- Vol. 3 (2) , 654-658
The Clinical Significance of Full Blood Count Day 1 Post-op After Total Joint Arthroplasty
- Open Access
- 28 June 2020
- Published by BMJ in BMJ Case Reports
- Vol. 13 (6) , e235426
High-energy traumatic proximal and distal interphalangeal joint dislocation in the same finger
- 28 June 2020
- Published by BMJ in BMJ Case Reports
- Vol. 13 (6) , e235426
Open AccessHigh-energy traumatic proximal and distal interphalangeal joint dislocation in the same finger
- 1 January 2020
- Published by Elsevier in Journal of Surgical Education
- Vol. 77 (1) , 115-123
A Prospective Review of a Novel Electronic Journal Club Format in an Orthopedic Residency Unit
- 1 January 2020
- Published by Elsevier in Journal of Surgical Education
- Vol. 77 (1) , 115-123
A Prospective Review of a Novel Electronic Journal Club Format in an Orthopedic Residency Unit
- 28 August 2019
- Published by BMJ in BMJ Case Reports
- Vol. 12 (8) , e230783
Displaced Salter-Harris I fracture of the distal ulna physis
A 10-year-old girl presented to the emergency department having sustained a fall onto an outstretched left hand while playing soccer. Clinical and radiographical assessment identified a Salter-Harris I distal ulna fracture, as well as a buckle fracture of the distal radius. The injury was closed, and she had no neurovascular deficits on examination. She was brought to the operating theatre the following morning for closed reduction under general anaesthesia. Image intensification was used to confirm anatomical reduction, and an above-elbow moulded plaster-of-paris cast was applied. Follow-up clinical assessment at 6 weeks confirmed healing of the fracture, and she proceeded to make a full recovery. This case describes the anatomy and physiology of such rare injuries and outlines treatment principles and potential pitfalls based on best available evidence.
- 28 August 2019
- Published by BMJ in BMJ Case Reports
- Vol. 12 (8) , e230783
Displaced Salter-Harris I fracture of the distal ulna physis
A 10-year-old girl presented to the emergency department having sustained a fall onto an outstretched left hand while playing soccer. Clinical and radiographical assessment identified a Salter-Harris I distal ulna fracture, as well as a buckle fracture of the distal radius. The injury was closed, and she had no neurovascular deficits on examination. She was brought to the operating theatre the following morning for closed reduction under general anaesthesia. Image intensification was used to confirm anatomical reduction, and an above-elbow moulded plaster-of-paris cast was applied. Follow-up clinical assessment at 6 weeks confirmed healing of the fracture, and she proceeded to make a full recovery. This case describes the anatomy and physiology of such rare injuries and outlines treatment principles and potential pitfalls based on best available evidence.
- 15 February 2019
- Published by Springer Nature in Irish Journal of Medical Science (1971 -)
- Vol. 188 (4) , 1233-1237
Arthroscopic anterior shoulder stabilisation in overhead sport athletes: 5-year follow-up
Shoulder instability following traumatic glenohumeral dislocation is a common injury sustained by athletes particularly in contact and collision sports. Overhead contact sports such as gaelic football and hurling pose a unique hazard to the glenohumeral joint, increasing the risk of dislocation.
- 15 February 2019
- Published by Springer Nature in Irish Journal of Medical Science (1971 -)
- Vol. 188 (4) , 1233-1237
Arthroscopic anterior shoulder stabilisation in overhead sport athletes: 5-year follow-up
Shoulder instability following traumatic glenohumeral dislocation is a common injury sustained by athletes particularly in contact and collision sports. Overhead contact sports such as gaelic football and hurling pose a unique hazard to the glenohumeral joint, increasing the risk of dislocation.
- Open Access
- 25 September 2018
- Published by Cureus, Inc. in Cureus
- Vol. 10 (9) , e3356
The Role of Circular Frames in the Management of Tibial Fractures
Introduction The purpose of this study is to evaluate the factors that impact the clinical and radiographic outcomes in a patient cohort undergoing external fixation for tibial fractures. We also aim to investigate the use of autograft, allograft, and synthetic bone graft in varying combinations in the setting of tibial bone loss with respect to optimal times to union. Methods This was a retrospective study, including 46 patients treated with a circular external fixator for the management of acute tibial fractures. The study was carried out over a 10-year period, between 2007 and 2017, at our institution. The mean follow-up at the time of review was 4.6 years. Primary outcome measures were ‘time to union,’ ‘delayed union’ (> 6 months), ‘infection,’ and ‘duration of external fixation.’ Secondary outcomes included 'length of hospital stay' and functional scores using the 'Short Form-12 (SF-12).' The statistical analysis included both univariate and multivariate analyses to control for confounding variables when assessing predictors of delayed union and infection. Results Forty-six patients fulfilled the study criteria. Fifteen fractures were classified as open. The mean number of procedures per patient was 3.8 and the mean length of stay per patient was 33 days. The mean time to union was 8.6 months overall. Significant predictors of prolonged time to union were the ‘number of interventions’ (p<0.01) the patient underwent and the ‘bone graft type’ (p<0.01) used. The time to union in the presence of either autograft or allograft was lengthened by the addition of synthetic graft. Five patients developed a deep tissue infection. The use of synthetic bone graft was significantly associated with infection (p<0.05). On subgroup analysis, it was found that the use of synthetic graft in any combination leads to significantly higher rates of deep tissue infection (p<0.05). The mean time to full weight bearing was 10.6 months (s=9.78, 3-36). The majority (57%) were using walking aids and 67% reported that the injury was still affecting their lifestyle. Conclusion Tibial fractures with bone loss are a complex group of injuries that often require multiple surgical interventions, prolonged hospital inpatient stay, and suboptimal functional outcomes in many cases. The best times to union are achieved when autograft is used alone without any other combination of bone graft type. The use of synthetic bone graft also significantly increases the rate of deep tissue infection in this cohort. We recommend the use of autograft alone when treating bone defects in tibial fractures with external fixators.
- 25 September 2018
- Published by Cureus, Inc. in Cureus
- Vol. 10 (9) , e3356
Open AccessThe Role of Circular Frames in the Management of Tibial Fractures
Introduction The purpose of this study is to evaluate the factors that impact the clinical and radiographic outcomes in a patient cohort undergoing external fixation for tibial fractures. We also aim to investigate the use of autograft, allograft, and synthetic bone graft in varying combinations in the setting of tibial bone loss with respect to optimal times to union. Methods This was a retrospective study, including 46 patients treated with a circular external fixator for the management of acute tibial fractures. The study was carried out over a 10-year period, between 2007 and 2017, at our institution. The mean follow-up at the time of review was 4.6 years. Primary outcome measures were ‘time to union,’ ‘delayed union’ (> 6 months), ‘infection,’ and ‘duration of external fixation.’ Secondary outcomes included 'length of hospital stay' and functional scores using the 'Short Form-12 (SF-12).' The statistical analysis included both univariate and multivariate analyses to control for confounding variables when assessing predictors of delayed union and infection. Results Forty-six patients fulfilled the study criteria. Fifteen fractures were classified as open. The mean number of procedures per patient was 3.8 and the mean length of stay per patient was 33 days. The mean time to union was 8.6 months overall. Significant predictors of prolonged time to union were the ‘number of interventions’ (p<0.01) the patient underwent and the ‘bone graft type’ (p<0.01) used. The time to union in the presence of either autograft or allograft was lengthened by the addition of synthetic graft. Five patients developed a deep tissue infection. The use of synthetic bone graft was significantly associated with infection (p<0.05). On subgroup analysis, it was found that the use of synthetic graft in any combination leads to significantly higher rates of deep tissue infection (p<0.05). The mean time to full weight bearing was 10.6 months (s=9.78, 3-36). The majority (57%) were using walking aids and 67% reported that the injury was still affecting their lifestyle. Conclusion Tibial fractures with bone loss are a complex group of injuries that often require multiple surgical interventions, prolonged hospital inpatient stay, and suboptimal functional outcomes in many cases. The best times to union are achieved when autograft is used alone without any other combination of bone graft type. The use of synthetic bone graft also significantly increases the rate of deep tissue infection in this cohort. We recommend the use of autograft alone when treating bone defects in tibial fractures with external fixators.
- 1 July 2018
- Published by Elsevier in Journal of Hospital Infection
- Vol. 99 (3) , 299-302
Assessment of theatre shoe contamination in an orthopaedic theatre
- 1 July 2018
- Published by Elsevier in Journal of Hospital Infection
- Vol. 99 (3) , 299-302
Assessment of theatre shoe contamination in an orthopaedic theatre