Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kun Liu has a total of 106 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Full-range CO 2 detection using dual-path WMS–DAS and multi-regime adaptive fusion

    by Chuan Li, Jie Wang, Ruifeng Wang, Guishi Wang, Xuezhe Xu, Xiaoming Gao, Kun Liu

    Tunable diode laser absorption spectroscopy (TDLAS) offers high sensitivity, selectivity, robustness, and real-time detection. However, most TDLAS-based sensors have a limited dynamic range, typically below 10 4 . Here, we propose a TDLAS-based method for full-dynamic-range CO 2 detection. A dual-path absorption cell is combined with a wavelength modulation spectroscopy–direct absorption spectroscopy (WMS–DAS) measurement strategy to realize full-range detection. A dual-logistic adaptive weighting algorithm is developed to fuse adjacent channels and suppress range-boundary discontinuities, enabling smooth and continuous transitions across adjacent detection regimes without hard switching. Experiments demonstrate that the proposed configuration and detection scheme enable CO 2 measurements from sub-ppm levels to 100% concentration, with a dynamic range of 3.3 × 10 6 , while achieving a 1σ detection limit of 0.3 ppm at an integration time of 72 s. The proposed method shows strong potential for applications ranging from trace-level environmental monitoring to industrial gas purity analysis.

  • Single-sideband spectrally resolution-enhanced laser heterodyne spectrometer for upper atmospheric sensing

    by Jun Li, Guishi Wang, Kun Liu, Xiaoming Gao, Tan Tu

    A single-sideband laser heterodyne spectrometer (LHS) was developed for the first time, to the best of our knowledge. A multi-channel configuration employing different band-pass filters and frequency-shifted LOs achieves single-sideband detection at the hardware level, thereby eliminating the central dip distortion inherent in conventional dual-sideband LHS. The operation of the single-sideband LHS was analyzed and experimentally validated through optimization of the frequency shift of acousto-optic modulators and the bandwidth of radio-frequency filters, yielding a two-fold enhancement in spectral resolution. The performance of the single-sideband LHS was evaluated and validated through measurements of methane absorption spectra. The results demonstrate a significant improvement in spectral fidelity, with the error reduced by 64% compared with conventional dual-sideband LHS. The single-sideband LHS reported in this paper is expected to provide a powerful tool with high spectral resolution and high accuracy for remote sensing of upper atmospheric gases and planetary atmospheric molecules.

  • Improving the classification performance of microplastics by noise reduction and baseline correction of Raman spectra with a neural network-based algorithm

    by Jiajin Chen, Weixiang Huang, Ligang Shao, Jiaoxu Mei, Tu Tan, Guishi Wang, Kun Liu, Xiaoming Gao

    Microplastics have emerged as global environmental pollutants, with Raman spectroscopy serving as an effective method for detecting and identifying them. However, conventional Raman preprocessing methods are often constrained by parameter sensitivity, a heavy reliance on manual intervention, and limited efficacy in handling complex signals. To overcome these limitations, we report the application of a ResUNet model integrated with Squeeze-and-Excitation (SE) blocks for the denoising and baseline correction of Raman spectra of microplastics, acquired under nonideal conditions characterized by low laser power and short acquisition times. Compared with the traditional combination of Wavelet Threshold Denoising and AirPLS baseline correction, a more than 15-fold improvement in the signal-to-noise ratio was achieved. In downstream classification tasks, even under stringent conditions (29.63 mW laser power and 750 ms integration time), the identification accuracy for microplastics was significantly enhanced from 35.13% in the raw data to 96.90%, notably outperforming the 55.70% accuracy attained by traditional methods. This work demonstrates the effectiveness of the SE-ResUNet neural network in enhancing spectral quality and optimizing post-processing outcomes.


  • Open Access

    Refined laser heterodyne spectroscopy technology for precise greenhouse gas monitoring

    by Guishi Wang, Zhao Chen, Hao Xiong, Nianna Fu, Kun Liu, Xiaoming Gao

    Carbon dioxide and methane are key greenhouse gases emitted by human activities, accounting for ~75% and ~18% of total greenhouse gases emissions at the global scale. However, current knowledge about the sources and sinks of both gases is still insufficient for reliable climate predictions. Space-based observations (such as GOSAT, OCO-2 and TANSAT), primary means for quantification of the sources and sinks on large scales, suffer from limited precision and sparse observational density. Whilst ground-based observations such as TCCON, equipped with high spectral resolution Fourier transform spectrometer (FTS, Bruker, IFS125HR), provide column-averaged abundances with high precision and accuracy, however the shortfalls (such as large dimensions and high cost of maintenance) limit further expansion of the observing network. Over the last decade, COCCON, which equipped with middle spectral resolution portable FTS (Bruker, EM27/SUN), has proven to be a promising complement to the ground-based observations. With the objective to develop a portable instrument maintained with high spectral resolution, a refined laser heterodyne radiometer (LHR) for precise remote sensing of greenhouse gases will be presented.

  • Open Access

    Cavity enhanced absorption spectroscopy for high precision measurement of greenhouse gases

    by Kun Liu, Weidong Chen, Xiaoming Gao

    Greenhouse gases (GHGs) emissions from human activities provided the majority contribution towards global warming, which make our world is now warming faster than at any point in recorded history. High precision measurement of GHGs are very important for monitoring or scientific studies. Here, laser absorption spectroscopy, especially, high sensitivity optical cavity enhanced absorption spectroscopy techniques and instruments for measurement of greenhouse gases were developed. High precision of 0.25 ppm and 2ppb was achieved for measurement of CO2 and CH4, by employing off-axis integrated cavity output spectroscopy technique. Using multi-pass cell based mid-infrared absorption spectroscopy, a precision of 0.1 ppb was achieved for N2O measurement. Results of the developed instruments for applications in GHGs measurements will be presented.

  • Real-time wavelength-calibrated laser heterodyne radiometer based on an all-fiber unbalanced Mach-Zehnder interferometer

    by Jun Li, Jingjing Wang, Guishi Wang, Kun Liu, Xiaoming Gao, Tu Tan

    Laser heterodyne spectroscopy is facilitating groundbreaking advances across multiple fields, including planetary atmospheric exploration, terrestrial greenhouse gas monitoring, wind field measurements, isotopic ratio analysis, and industrial gas emission monitoring. Nevertheless, Laser heterodyne radiometers (LHRs) lack effective wavelength calibration methods, which hinders their application in scenarios requiring miniaturization, high stability, and high precision. In this paper, what we believe to be a novel all-fiber LHR capable of real-time wavelength calibration is presented. The wavelength calibration scheme for this LHR was implemented using an all-fiber unbalanced Mach-Zehnder interferometer (MZI) combined with a corresponding wavelength calibration algorithm. Key performance-limiting factors of unbalanced MZI were experimentally analyzed. The criteria for determining the optimal optical path difference of the unbalanced MZI were established for the first time specifically for LHR applications. With a 22 cm unbalanced arm design, the system achieved a calibration resolution of 0.01623 cm -1 and demonstrated a calibration uncertainty of 2 × 10 −5  cm -1 at an averaging time of 1s. Its performance was validated through absorption spectra measurements conducted in a gas cell. Field measurements of atmospheric CO 2 absorption spectra were performed with the developed real-time wavelength-calibrated LHR. The unbalanced MZI wavelength calibration scheme not only provides a high-precision, environmentally robust frequency scale for laser heterodyne absorption spectroscopy but also exhibits great potential to serve as a reliable calibration solution for other high-resolution spectroscopic techniques.


  • Open Access

    Optical sensing platform based on tunable laser absorption spectroscopy for the measurement of carbon dioxide dissolved in seawater

    by Yongyong Hu, Patrick Augustin, Jingjing Wang, Kun Liu, Ruyue Cui, Hongpeng Wu, Lei Dong, Xiaoming Gao, Marc Fourmentin, Tong Nguyen Ba, et al.

    Ocean-atmosphere gas exchange plays a critical role in the global carbon cycle, as the ocean acts as both a major sink and source of atmospheric CO2. This exchange process regulates the Earth's carbon balance and influences climate systems on a global scale. Understanding the mechanisms of CO2 absorption and release at the ocean surface is essential for accurately assessing the ocean’s contribution to carbon fluxes [1].The present work introduces the development of a optical sensor based on Tunable Diode Laser Absorption Spectroscopy (TDLAS) for measurement of CO2 dissolved in seawater. This approach enables real-time measurement of CO2 concentrations in seawater for evaluation of CO2 distribution and study of exchange processes between ocean and atmosphere. The developed sensing platform involves a 2008 nm distributed feedback laser coupled to a compact 30-m multipass cell with 7-circle spot dense pattern [2] using wavelength modulation spectroscopy approach [Figure 1]. CO2 dissolved in seawater is extracted using a custom-designed membrane contactor extraction device.Figure 1. Experimental measurements of 2f absorption spectra of CO2 in air and dissolved in seawater.Performance of the CO2 sensing platform, experimental details and the preliminary results will be discussed and presented. AcknowledgmentsThis work is partially supported by the French national research agency (ANR) under the Labex CaPPA (ANR-10-LABX-005) and the ICAR-HO2 (ANR-20-CE04-0003) contracts, the EU H2020-ATMOS project (Marie Skłodowska-Curie grant agreement No 872081), the regional CPER ECRIN program, and the National Natural Science Foundation of China (Grant No. 62235010). The Région Hauts-de-France and the Pôle Métropolitain de la Côte d’Opale are gratefully acknowledged for PhD scholarship support. References[1] Tim DeVries, “The ocean carbon cycle”, Annual Review of Environment and Resources 47 (2022) 317-341.[2] Kun Liu, Lei Wang, Tu Tan, Guishi Wang, Weijun Zhang, Weidong Chen, Xiaoming Gao, “Highly sensitive detection of methane by near-infrared laser absorption spectroscopy using a compact dense-pattern multipass cell”, Sensors and Actuators B: Chemical 220 (2015) 1000-1005.

  • Open Access

    Sensitivity improvement of quartz-enhanced photoacoustic spectroscopy using the stochastic resonance method

    by Yingchao Xie, Hao Xiong, Shiling Feng, Ning Pan, Chuan Li, Yixuan Liu, Ye Zhang, Ligang Shao, Gaopeng Lu, Kun Liu, et al.


  • Improving the reconstruction accuracy of tomographic absorption spectroscopy sensor by optimizing laser beam arrangements

    by Pengfei Yu, Ruifeng Wang, Zhao Chen, Tianxu Huang, Jiaoxu Mei, Guishi Wang, Xiaoming Gao, Kun Liu

    Tomographic absorption spectroscopy (TAS) typically employs multiple projections to reconstruct the spatial distribution of temperature and species concentration, making it a promising method for combustion diagnostics. However, the geometric arrangement of the laser beams significantly affects its accuracy, especially under limited beam conditions. In this work, we propose a beam arrangement optimization method to maximize the utilization efficiency of limited beams, thereby improving reconstruction accuracy in a simpler and more intuitive manner. We designed a cost function that combines the beam number matrix (BNM) and the total weight matrix (TWM). This approach ensures that the maximum number of rays passes through each grid while also maximizing the optical path length in the regions covered by the beam distribution. The optimization is performed using a simulated annealing algorithm to obtain the optimal beam arrangement. For a TAS sensor comprising 12 laser beams, numerical simulations demonstrate that the BNM-TWM optimized beam arrangement achieves lower reconstruction errors across various synthetic temperature fields when compared to traditional orthogonal beam arrangements and those optimized for orthogonality (OD). This improvement is particularly significant when the performance of the orthogonal and OD-optimized arrangements is suboptimal. Finally, we demonstrate the application of the BNM-TWM optimized beam arrangement for reconstructing temperature distributions of asymmetric butane flames, where parallel beam distributions were ineffective. The results effectively pinpoint the location of the flame, showing a temperature difference of less than 3% compared to thermocouple measurements for the center of the flame. These findings indicate that the developed beam arrangement optimization method has the potential to enhance the accuracy of TAS reconstruction under limited beam conditions and could be extended to other tomographic imaging systems.


  • Baseline-free retrieval algorithm for broadband absorption spectra of H2O at high temperatures and pressures

    by Tianxu Huang, Ruifeng Wang, Guishi Wang, Jiaoxu Mei, Xiaoming Gao, Kun Liu

    Absorption spectroscopy is a widely used non-contact combustion diagnostic technique. H2O is frequently used as the target molecule for combustion temperature measurement. However, correcting the baseline in broadened absorption spectroscopy under high pressure remains challenging. In this Letter, we propose a new, to the best of our knowledge, processing algorithm, the Interpolated Envelope Correction Method (IECM), for baseline-free correction in broadband absorption spectra, enabling simultaneous retrieving of pressure, temperature, and H2O concentration in high-temperature and high-pressure scenarios. The IECM first calculates the lower envelope from the measured spectrum and subtracts it from the spectrum and then processes least-squares fit based on the theory of absorption spectroscopy, to retrieve measured pressure, temperature, and concentration. Experimental results indicate that the IECM outperforms the background polynomial method at temperatures below 1273 K and pressures below 70 bar. An RMSE (root mean squared error) of 1.49 bar and 17 K was achieved using the IECM to retrieve pressure and temperature, which are smaller than other commonly used methods. The proposed IECM avoids the problem of the baseline, making it more convenient in the application of high-pressure combustion diagnostics.