Eric James Davis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eric James Davis has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
William F. Siems
Washington State University
9 shared publicationsHerbert H. Hill
Washington State University
5 shared publications- Herbert Henderson Hill
Department of Chemistry, Washington State University, Pullman, Washington 99163, United States
5 shared publications Brian H. Clowers
Washington State University, Department of Chemistry, PO Box 644630, Pullman, WA 99164, United States
3 shared publicationsSteve Pauls
Fresno Pacific University, Fresno, California 93702, United States
3 shared publicationsCharles S. Harden
Leidos at US Army Edgewood Chemical Biological Center, Aberdeen Proving Ground, USA
2 shared publications
Latest Publications
- Open Access
- 16 November 2026
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
“Vibe-Coding” Process with AI in Analytical Chemistry: A Rapid Development Method for Prototyping Instrumentation and Data Workflows
Modern analytical instrumentation research is fundamentally built upon custom software to manage data input/output (I/O) and hardware control. However, development of such software requires extensive experience and expertise in software engineering, limiting the ability of many research groups to develop new instrumental prototypes. The advent of agentic, large-language model (LLM) Artificial Intelligence (AI) software engineering where AI handles all writing, testing, debugging, and execution of code under the direction and validation of the researcher (“Vibe Coding”) provides a mechanism to rapidly bridge this experience gap and give researchers functional, high-level code without necessitating expertise in software development. In this tutorial, we describe a lightweight, four-stage software development lifecycle (SDLC) for agentic coding (prompt engineering and architecture design, iterative agentic debugging, human-in-the-loop validation, and regression testing via simulation) and demonstrate it through the development of a control and analysis software suite for atmospheric pressure Ion Mobility Spectrometry (IMS). This process is easily expanded to any analytical instrumentation in the research laboratory through commonly available Python libraries. As the agent is guided by user prompts, prior knowledge of such libraries is helpful, but not required as modern agents can “plan” a process through both user input and open web search background information. With proper understanding of crafting AI prompts and using them in the SDLC, agentic coding promises to allow rapid prototyping in the research lab at minimal cost.
- 16 November 2026
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
Open Access“Vibe-Coding” Process with AI in Analytical Chemistry: A Rapid Development Method for Prototyping Instrumentation and Data Workflows
Modern analytical instrumentation research is fundamentally built upon custom software to manage data input/output (I/O) and hardware control. However, development of such software requires extensive experience and expertise in software engineering, limiting the ability of many research groups to develop new instrumental prototypes. The advent of agentic, large-language model (LLM) Artificial Intelligence (AI) software engineering where AI handles all writing, testing, debugging, and execution of code under the direction and validation of the researcher (“Vibe Coding”) provides a mechanism to rapidly bridge this experience gap and give researchers functional, high-level code without necessitating expertise in software development. In this tutorial, we describe a lightweight, four-stage software development lifecycle (SDLC) for agentic coding (prompt engineering and architecture design, iterative agentic debugging, human-in-the-loop validation, and regression testing via simulation) and demonstrate it through the development of a control and analysis software suite for atmospheric pressure Ion Mobility Spectrometry (IMS). This process is easily expanded to any analytical instrumentation in the research laboratory through commonly available Python libraries. As the agent is guided by user prompts, prior knowledge of such libraries is helpful, but not required as modern agents can “plan” a process through both user input and open web search background information. With proper understanding of crafting AI prompts and using them in the SDLC, agentic coding promises to allow rapid prototyping in the research lab at minimal cost.
- Open Access
- 8 December 2025
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 37 (1) , 86-94
Asynchronous Stepped Fourier Transform Ion Mobility Spectrometry
Fourier Transform is a low-cost method for improving duty cycle, resolving power, and signal-to-noise ratio in the Ion Mobility Spectrometry (IMS) experiment in a 2-gate IMS cell. By simultaneously pulsing both gates through a frequency sweep, the resulting data may be deconvoluted into a time-based mobility spectrum through a Fast Fourier Transform (FT). However, inconsistencies common in low-cost function generators result in spectral artifacts. In this work, an asynchronous stepped frequency FTIMS method is demonstrated, which uses a simple, software timed pulse generator compatible with any modern Analog-Digital Converter (ADC) system. By unlinking the frequency initiation and data collection using a long rise-time amplifier circuit, a stand-alone FTIMS with Faraday Plate detection was characterized in both single gate and FT modes of operation using the same IMS cell. Asynchronous stepped FTIMS parameters were investigated for system optimization with respect to resolving power, signal-to-noise ratio, and experimental time. Once optimized, asynchronous FTIMS demonstrated significant improvements in resolving power and signal-to-noise ratios without a significant increase in experimental time. By unlinking the frequency generation and data analysis, a simple Python script was demonstrated using a variety of commercially available ADC systems ranging in cost from several thousand to several hundred dollars (USD) without sacrificing spectral fidelity. A custom circuit was developed to allow a Raspberry Pi 4 Single Board Computer (SBC) to function as the data acquisition and control (DAC) interface for a low-cost stand-alone FTIMS solution.
- 8 December 2025
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 37 (1) , 86-94
Open AccessAsynchronous Stepped Fourier Transform Ion Mobility Spectrometry
Fourier Transform is a low-cost method for improving duty cycle, resolving power, and signal-to-noise ratio in the Ion Mobility Spectrometry (IMS) experiment in a 2-gate IMS cell. By simultaneously pulsing both gates through a frequency sweep, the resulting data may be deconvoluted into a time-based mobility spectrum through a Fast Fourier Transform (FT). However, inconsistencies common in low-cost function generators result in spectral artifacts. In this work, an asynchronous stepped frequency FTIMS method is demonstrated, which uses a simple, software timed pulse generator compatible with any modern Analog-Digital Converter (ADC) system. By unlinking the frequency initiation and data collection using a long rise-time amplifier circuit, a stand-alone FTIMS with Faraday Plate detection was characterized in both single gate and FT modes of operation using the same IMS cell. Asynchronous stepped FTIMS parameters were investigated for system optimization with respect to resolving power, signal-to-noise ratio, and experimental time. Once optimized, asynchronous FTIMS demonstrated significant improvements in resolving power and signal-to-noise ratios without a significant increase in experimental time. By unlinking the frequency generation and data analysis, a simple Python script was demonstrated using a variety of commercially available ADC systems ranging in cost from several thousand to several hundred dollars (USD) without sacrificing spectral fidelity. A custom circuit was developed to allow a Raspberry Pi 4 Single Board Computer (SBC) to function as the data acquisition and control (DAC) interface for a low-cost stand-alone FTIMS solution.
- Open Access
- 10 November 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (46) , 25576-25582
Solving the “General Elution Problem” of Ion Mobility Spectrometry: Single-Run Voltage Sweep
While modern mobility methods have shifted toward vacuum-based techniques that allow advanced ion manipulations to improve resolution, atmospheric pressure ion mobility spectrometry (IMS) cells continue to find utility in primary security and screening applications. These small units generally demonstrate low resolution due to both their size and inability to perform advanced ion manipulations at atmospheric pressure. Existing drift time IMS cells utilize a static voltage typically tuned to optimize both total signal and separation efficiency for the ions of particular interest in a given application. These static voltage IMS cells suffer from a phenomenon similar to the general elution problem of chromatography, wherein the separation conditions are optimized for a particular species at the expense of the other analytes in the system. Through the application of an external high voltage sweep (VS) tuned to match the theoretical optimum potential at every drift time, this work solves the General Elution Problem of IMS. In comparison to static mode, VSIMS demonstrates significantly improved resolution and resolving power while maintaining fidelity in reduced mobility measurements. When applied to a library of IMS standards, VSIMS demonstrates consistent, reproducible resolving powers regardless of the mobility of the ion introduced to the instrument.
- 10 November 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (46) , 25576-25582
Open AccessSolving the “General Elution Problem” of Ion Mobility Spectrometry: Single-Run Voltage Sweep
While modern mobility methods have shifted toward vacuum-based techniques that allow advanced ion manipulations to improve resolution, atmospheric pressure ion mobility spectrometry (IMS) cells continue to find utility in primary security and screening applications. These small units generally demonstrate low resolution due to both their size and inability to perform advanced ion manipulations at atmospheric pressure. Existing drift time IMS cells utilize a static voltage typically tuned to optimize both total signal and separation efficiency for the ions of particular interest in a given application. These static voltage IMS cells suffer from a phenomenon similar to the general elution problem of chromatography, wherein the separation conditions are optimized for a particular species at the expense of the other analytes in the system. Through the application of an external high voltage sweep (VS) tuned to match the theoretical optimum potential at every drift time, this work solves the General Elution Problem of IMS. In comparison to static mode, VSIMS demonstrates significantly improved resolution and resolving power while maintaining fidelity in reduced mobility measurements. When applied to a library of IMS standards, VSIMS demonstrates consistent, reproducible resolving powers regardless of the mobility of the ion introduced to the instrument.
- 25 February 2025
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 102 (3) , 1281-1284
Green Calorimetry through 3D Printing─Coffee Cup Calorimetry
- 25 February 2025
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 102 (3) , 1281-1284
Green Calorimetry through 3D Printing─Coffee Cup Calorimetry
- 3 November 2021
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 98 (12) , 4078-4087
Implementation of a Socially Distanced In-Person Laboratory Experience Across the Chemistry Curriculum during the COVID-19 Pandemic at a Small, Liberal Arts University
- 3 November 2021
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 98 (12) , 4078-4087
Implementation of a Socially Distanced In-Person Laboratory Experience Across the Chemistry Curriculum during the COVID-19 Pandemic at a Small, Liberal Arts University
- 11 October 2021
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 413 (28) , 6905-6915
3D printing lifts the lid on black box instruments
- 11 October 2021
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 413 (28) , 6905-6915
3D printing lifts the lid on black box instruments
- Open Access
- 27 May 2021
- Published by American Chemical Society (ACS)
Arcspray optical emission spectroscopy: Simple and robust method elemental analysis towards field-based measurements
- 27 May 2021
- Published by American Chemical Society (ACS)
Open AccessArcspray optical emission spectroscopy: Simple and robust method elemental analysis towards field-based measurements
- 4 August 2020
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 97 (9) , 2691-2695
Use of 3D Printing to Manufacture Document Camera Mounts in Support of Online Education Shifts during the COVID-19 Pandemic
The 2020 pandemic involving SARS-CoV-2 (COVID-19) resulted in a rapid shift to online education for instructors at every level around the world. This shift occurred with little training and minimal resources available due to the rapidity of onset. In this technology report, we describe the use of 3D printing to rapidly manufacture mounts for commonly used webcams, which allow them to be pointed downward and serve as document cameras for those instructors and students accustomed to board-based pedagogical methods. These mounts were designed to connect a webcam to a standard laboratory ring stand and could be printed using as little as 55 g of plastic ($1.38 per unit using plastic at $25.00 per 1000 g) in about 3 h per mount using default printer settings. The use of these mounts allowed a semblance of normality in pedagogy for both students and instructors during the rapid shift to online education, and this was reflected in student evaluations from a General Chemistry II and Organic Chemistry II course where they were utilized.
- 4 August 2020
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 97 (9) , 2691-2695
Use of 3D Printing to Manufacture Document Camera Mounts in Support of Online Education Shifts during the COVID-19 Pandemic
The 2020 pandemic involving SARS-CoV-2 (COVID-19) resulted in a rapid shift to online education for instructors at every level around the world. This shift occurred with little training and minimal resources available due to the rapidity of onset. In this technology report, we describe the use of 3D printing to rapidly manufacture mounts for commonly used webcams, which allow them to be pointed downward and serve as document cameras for those instructors and students accustomed to board-based pedagogical methods. These mounts were designed to connect a webcam to a standard laboratory ring stand and could be printed using as little as 55 g of plastic ($1.38 per unit using plastic at $25.00 per 1000 g) in about 3 h per mount using default printer settings. The use of these mounts allowed a semblance of normality in pedagogy for both students and instructors during the rapid shift to online education, and this was reflected in student evaluations from a General Chemistry II and Organic Chemistry II course where they were utilized.