AFAllen J. Flynn

Allen J. Flynn

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Allen J. Flynn has a total of 135 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Potential for a Benefit-Estimating Algorithm to Improve Recommendations for Preventive Services: Comparing Algorithm Recommendations with Those of Primary Care Providers

    by Marisa L. Conte, Philip Boonstra, Tanner J. Caverly, Astrid Fishstrom, Allen Flynn, Glen B. Taksler, Charles P. Friedman

    Purpose: To compare an established benefit-estimating algorithm for recommending and prioritizing preventive services for a patient (Individualized Precision Prevention; IPP) with concordant rankings from primary care providers (PCPs). Methods: We developed 12 realistic routine patient care scenarios focused on preventive services and recruited 40 PCPs to rank the priority of recommended preventive services. Our analysis compared the benefit-estimating algorithm’s rankings of preventive services for each of the 12 patient scenarios to the PCPs’ rankings using length-dependent rank-biased overlap (LDRBO) calculations. Moderate concordance would suggest that the computer algorithm presented an opportunity to improve preventive care, whereas very high or low concordance would call into question what the algorithm could contribute to clinical practice. Results: For all 12 patient care scenarios, comparing the benefit-estimating algorithm’s output to the combined priority rankings from all PCPs yields a mean value of 0.45, corresponding to a moderate level of concordance or agreement between the numeric rankings of the algorithm and the expert provider rankings. This study illustrates the potential importance of having computed IPP recommendations readily available for point-of-care decision making by PCPs. Conclusion: We demonstrate that this approach aligned with the overall judgment of clinical experts and may help providers prioritize preventive services in time-constrained clinical contexts. The modest correlation between the benefit-estimating algorithm and expert providers suggests that, in some cases, the algorithm has the potential to provide useful advice about preventive services during care. Highlights: Using scenarios, we compared how primary care providers and an algorithm prioritized recommendations for preventive services based on individual information about a patient. The providers’ rankings of the clinical importance of preventive services were moderately concordant with rankings produced by the algorithm, suggesting that the algorithm presents an opportunity to improve the effects of preventive care. For half of the scenarios, the algorithm recommended one preventive service that was not in the PCPs’ consensus top 3, suggesting that the algorithm may raise provider awareness of services that may be beneficial to specific patients. An algorithm-driven approach to individualized precision prevention that uses a patient’s data to generate personalized recommendations of preventive services can help providers and patients identify and prioritize high-priority preventive services together.

  • Open Access

    Linking FHIR ‐Based Medication Data to a Computable Algorithm for Heart Medication Optimization: A Critical Component of Any Medication Learning Health System

    by Joey LeGrand, Mohamed S. Ali, Allen Flynn, Juan Arzac, Corey Lester, Michael P. Dorsch

    Introduction: Despite strong evidence supporting guideline‐directed medical therapy (GDMT) for heart failure with reduced ejection fraction (HFrEF), a significant gap persists in the consistent application of these therapies. This shortfall has prompted organizations like the American College of Cardiology to recommend leveraging electronic health records (EHR) to optimize GDMT. This paper discusses the development of SmartHF, a clinical decision support system designed to enhance therapy adherence by effectively linking Fast Healthcare Interoperability Resources (FHIR)‐based medication data with clinical algorithms tailored for the management of HFrEF. Methods: The SmartHF system integrates FHIR‐based medication data with clinical algorithms through a multi‐step approach. Central to this process is data from CodeRx, a platform that utilizes streamlined data pipelines to map medication products to their ingredients using RxNorm. The methodology addresses the challenge of interpreting both structured and unstructured medication instructions, ensuring a precise linkage of product identifiers to algorithm‐relevant ingredients and their corresponding strengths. Specific attention is given to the data granularity needed for distinguishing precise ingredients within complex formulations, such as sacubitril/valsartan and metoprolol salt form variants. Results: The deployment of SmartHF involved rigorous testing using actual and synthetic patient datasets to validate its functionality. Results demonstrated the system's ability to process FHIR MedicationRequest data resources accurately, convert free‐text dosing instructions into usable formats, and handle edge cases, including non‐standard products and missing dose information. Conclusions: This article describes the potential of FHIR‐based medication data integration for enhancing clinical decision support tools and improving care quality. It highlights the challenges and solutions for this integration.

  • Open Access

    A prototype ETL pipeline that uses HL7 FHIR RDF resources when deploying pure functions to enrich knowledge graph patient data

    by Adeel Ansari, Marisa Conte, Allen Flynn, Avanti Paturkar

    For clinical care and research, knowledge graphs with patient data can be enriched by extracting parameters from a knowledge graph and then using them as inputs to compute new patient features with pure functions. Systematic and transparent methods for enriching knowledge graphs with newly computed patient features are of interest. When enriching the patient data in knowledge graphs this way, existing ontologies and well-known data resource standards can help promote semantic interoperability. We developed and tested a new data processing pipeline for extracting, computing, and returning newly computed results to a large knowledge graph populated with electronic health record and patient survey data. We show that RDF data resource types already specified by Health Level 7's FHIR RDF effort can be programmatically validated and then used by this new data processing pipeline to represent newly derived patient-level features. Knowledge graph technology can be augmented with standards-based semantic data processing pipelines for deploying and tracing the use of pure functions to derive new patient-level features from existing data. Semantic data processing pipelines enable research enterprises to report on new patient-level computations of interest with linked metadata that details the origin and background of every new computation.


  • Open Access

    A Web-Based Tool to Perform a Values Clarification for Stroke Prevention in Patients With Atrial Fibrillation: Design and Preliminary Testing Study

    by Michael P Dorsch, Allen J Flynn, Kaitlyn M Greer, Sabah Ganai, Geoffrey D Barnes, Brian Zikmund-Fisher

    Background: Atrial fibrillation (AF) is associated with an increased risk of stroke. Oral anticoagulation (OAC) is used for stroke prevention in AF, but it also increases bleeding risk. Clinical guidelines do not definitively recommend for or against OAC for patients with borderline stroke risk. Decision-making may benefit from values clarification exercises to communicate risk trade-offs. Objective: This study aimed to evaluate if a visual with a values clarification alters the understanding of the trade-offs of anticoagulation in AF. Methods: Participants aged 45‐64 years were recruited across the United States via an online survey. While answering the survey, they were asked to imagine they were newly diagnosed with AF with a CHA2DS2-VASc (congestive heart failure; hypertension; age ≥75 years [doubled]; type 2 diabetes; previous stroke, transient ischemic attack, or thromboembolism [doubled]; vascular disease; age 65 to 75 years; and sex category) score of 1 for men and 2 for women. Eligibility criteria included no diagnosis of AF and no prior OAC use. Participants were randomized to one of three conditions: (1) standard text-based information only (n=255), (2) visual aids showing stroke-risk probabilities (n=218), or (3) visual aids plus a values clarification exercise (visual+VC; n=200). Participants were subrandomized within the 2 visual-based groups to view either a gauge display or an icon array representing stroke risk. All participants read a hypothetical scenario of being newly diagnosed with AF and hypertension. The primary outcome was decision confidence as measured by the SURE (Sure of Myself; Understand Information; Risk-Benefit Ratio; Encouragement) test. Secondary measures included participants’ perceived stroke risk reduction, worry about stroke or bleeding, and likelihood to choose OAC. Results: A total of 673 participants completed the survey. The overall SURE test was 61.2% (156/255) for the standard, 66.5% (145/218) for the visual, and 67% (134/200) for the visual+VC group (visual vs standard P=.23; visual+VC vs standard P=.20). Participants were less likely to choose OAC in the visual groups (standard: mean 58.3, SD 30; visual: mean 51.4, SD 32; visual+VC: 51.9, SD 28; P=.03). Participants felt the reduction in stroke risk from an OAC was less in the visual groups (standard: mean 63.8, SD 22; visual: mean 54.2, SD 28; visual+VC: mean 58.6, SD 25; P<.001). Visualization methods (gauge vs icon array) showed no significant differences in overall SURE test results. Participants were less likely to choose OAC and perceived a smaller stroke risk reduction with gauge than icon array (OAC choice: gauge 48.8, icon array 55.4; P=.03; stroke risk reduction: gauge 52.1, icon array 60.4; P=.001). Conclusions: Visual aids can modestly affect decision confidence and perceptions regarding the benefits of OAC but do not significantly alter decision certainty in a scenario where the guidelines do not recommend for or against OAC. Future work should determine the role of a gauge versus icon array visual for decision-making in stroke prevention in AF.


  • Using name overlap analysis to understand medication name search safety

    by Allen Flynn, Katherine D Mieure, Conor Myers

    In an effort to expedite the publication of articles, AJHP is posting manuscripts online as soon as possible after acceptance. Accepted manuscripts have been peer-reviewed and copyedited, but are posted online before technical formatting and author proofing. These manuscripts are not the final version of record and will be replaced with the final article (formatted per AJHP style and proofed by the authors) at a later time. To examine the degree of left-to-right character overlap in medication names as they appear in real-world computer systems. We programmed a computer to create and automatically analyze left-to-right character overlap in names appearing on 20,020 lists of real-world medications. The lists varied in length from 100 to 500 medication names and were created by randomly drawing names from a pool of 2,249 medication names extracted from an operating medication use system database. Overall maximum left-to-right character overlap varied in lists of 100 to 500 medication names from 4 to 29 characters (mode of 14 characters). For a small subset of names for high-alert medications that must never be administered in error, overall maximum left-to-right character overlap varied from 3 to 10 characters (mode of 6 characters). Further, for users searching for medications by name in computer systems, the keystrokes that do the most work to disambiguate medication names on a list are always the initial few keystrokes. Medication name left-to-right character overlap on lists of names searched ranges widely. Instead of requiring all users to type a set number of characters when searching for medications by name, search safety can potentially be improved by upgrading computer systems to dynamically respond to each keystroke entered. Using incremental dynamic search, searchers would often be able to type fewer than 5 characters to isolate a single medication by name but would sometimes have to type many more than 5 characters to do so.

  • Open Access

    Digital objects to make computable biomedical knowledge FAIR: an infrastructural approach to knowledge representation, dissemination and implementation

    by Marisa Conte, Allen Flynn, Philip Barrison, Peter Boisvert, Zach Landis-Lewis, Charles Friedman

    We present our work to develop digital objects to represent and convey a specific category of scientific knowledge: computable biomedical knowledge (CBK). Properly developed, validated, implemented and stewarded, CBK has the potential to accelerate the translation of actionable knowledge from scientific discovery to clinical application. Our research takes an infrastructural approach to CBK, initially by focusing on the creation of a conceptual model for packaging computable biomedical knowledge - the Knowledge Object (KO) - and on corresponding efforts to create an architecture for KO management and implementation. Additionally, our work is grounded in the FAIR principles, such that KO artefacts should be findable, accessible, interoperable and reusable and we are exploring aligning KOs with emerging best practices for FAIR Digital Objects (FDO). The outcomes of this work resonate in clinical contexts, health professions education, healthcare quality improvement, biomedical and translational research and population care. Our KO model is also of interest to researchers and practitioners interested in knowledge science, including those working with semantic technologies and other forms of digital objects.


  • Open Access

    Computable phenotypes for cohort identification: core content for a new class of FAIR Digital Objects

    by Marisa Conte, Allen Flynn, Peter Boisvert, Zach Landis-Lewis, Rachel Richesson, Charles Friedman

    Introduction We present current work to develop and define a class of digital objects that facilitates patient cohort identification for clinical studies, such that these objects are Findable, Accessible, Interoperable, and Reusable (FAIR) (Wilkinson et al. 2016). Developing this class of FAIR Digital Objects (FDOs) builds on the work of several years to develop the Knowledge Grid (https://kgrid.org/), which facilitates the development, description and implementation of biomedical knowledge packaged in machine-readable and machine-executable formats (Flynn et al. 2018). Additionally, this work aligns with the goals of the Mobilizing Computable Biomedical Knowledge (MCBK) community (https://mobilizecbk.med.umich.edu/) (Mobilizing Computable Biomedical Knowledge 2018). In this abstract, we describe our work to develop a FDO carrying a computable phenotype. Defining computable phenotypes In biomedical informatics, 'phenotyping' describes a data-driven approach to identifying a group of individuals sharing observable characteristics of interest, generally related to a disease or condition, and a 'computable phenotype' (CP) is a machine-processable expression of a phenotypic pattern of these characteristics (Hripcsak and Albers 2018). For the purposes of this work, we are interested in CPs derived from data contained in electronic health record (EHR) systems. This includes both structured data, e.g. codes for diseases, diagnoses, procedures, or laboratory tests, and unstructured data, e.g. free text including patient histories, clinical observations, discharge summaries, and reports. Thus, we define computable phenotype FDOs (CP-FDOs) as a class of FDO that packages an executable EHR-derived CP together with documentation needed to implement and use it effectively for creating cohorts of individuals with similar observable characteristics from EHR data sets. Importance of portable and FAIR CPs There is tremendous excitement for using real-world EHR data to discover important findings about human health and well-being. However, for discovery to happen, researchers need mechanisms like CPs to identify study cohorts for analysis. Beginning in the early 2010s, a growing literature explores various methods for the secondary use of EHR data for patient phenotyping to arrive at consistent study cohorts (Shivade et al. 2014, Banda et al. 2018). The heterogeneous nature of EHR data has inspired a wide variety of phenotyping methods, from those which rely solely on documented codes linked to terms in existing vocabularies to those which combine such codes with other concepts extracted from free text using natural language processing. Our current focus is on packaging CPs inside FDOs for classifying patients as having or not having a phenotype of interest. This can be done within an individual health system, or at scale across a clinical data research network. Using CPs for cohort identification can reduce the time and expense of traditional data set building and clincal trial recruitment, and expand the potential scope of a study population(Boland et al. 2013). Creating and validating CPs requires time, resources, and both clinical and technical expertise. One estimate is that it can take 6-10 months to develop and validate a CP (Shang et al. 2019). And, as there is no standard data model within EHRs in the United States, many CPs are designed for performance at a single site, rather than for portability, which is understood as the ability to implement a phenotype at a different site with similar performance (Shang et al. 2019). While portability is increasingly recognized as an important element of phenotyping, and there have been recent efforts to develop more portable CPs, many of these processes still require significant technical expertise at the implementation site to adapt the phenotype for use on local data. There may also be significant advantages to making CPs FAIR. These include transparency in cohort selection, and better generalizability of results. FAIR CPs may also increase the potential for robust comparisons of data from related studies, leading to better evidence synthesis to improve delivery of care and ultimately human health. Defining a new class of FDOs to hold and convey CPs We believe that packaging validated CPs inside digital objects may alleviate many of the pressures mentioned above, and contributes to making both the processes and products of clinical research more FAIR. To this end, our current work focuses on packaging a validated CP inside a machine-processable FDO. The phenotype of interest identifies pediatric and adult patients with a rare disease (Oliverio et al. 2021), and has several features which make it ideal for transformation to an executable FDO. First, the phenotype utilizes standards to define the clinical characteristics of interest, and is based on a common data model; these features increase the potential for both interoperability and reuse. Additionally, because the phenotype has been validated across three sites, its portability has already been demonstrated. Finally, the full computable phenotype has been shared as a series of SQL queries, including scripts for patient identification, deriving statistics, and validation, which have been annotated with instructions for implementation at other sites. The goals of this work are: To develop CPs as executable DOs, leveraging previous work to develop executable Knowledge Objects (KO) (Flynn et al. 2018) To advance our understanding of how to define computable phenotypes as a class of FDO, including what is needed to meet the requirements of binding, abstraction, and encapsulation (Wittenburg et al. 2019) To develop CPs as executable DOs, leveraging previous work to develop executable Knowledge Objects (KO) (Flynn et al. 2018) To advance our understanding of how to define computable phenotypes as a class of FDO, including what is needed to meet the requirements of binding, abstraction, and encapsulation (Wittenburg et al. 2019) Conclusion Computable phenotypes, packaged as FDOs, may increase the potential both for the portability of a phenotype and the reusability of data resulting from its implementation. Providing CPs as executable FDOs may also reduce barriers to portability and local implementation. In this presentation, we describe our work to develop a FDO computable phenotype from an existing validated phenotype. Lessons learned from this process will increase our understanding of both the technical requirements, and how to address necessary components of abstraction, binding, and encapsulation so that these can function as FAIR Digital Objects.


  • Open Access

    CBKmodel composition using paired web services and executable functions: A demonstration for individualizing preventive services

    by Allen Flynn, Glen Taksler, Tanner Caverly, Adam Beck, Peter Boisvert, Philip Boonstra, Nate Gittlen, George Meng, Brooke Raths, Charles P. Friedman

    Introduction: Learning health systems are challenged to combine computable biomedical knowledge (CBK) models. Using common technical capabilities of the World Wide Web (WWW), digital objects called Knowledge Objects, and a new pattern of activating CBK models brought forth here, we aim to show that it is possible to compose CBK models in more highly standardized and potentially easier, more useful ways.Methods: Using previously specified compound digital objects called Knowledge Objects, CBK models are packaged with metadata, API descriptions, and runtime requirements. Using open‐source runtimes and a tool we developed called the KGrid Activator, CBK models can be instantiated inside runtimes and made accessible via RESTful APIs by the KGrid Activator. The KGrid Activator then serves as a gateway and provides a means to interconnect CBK model outputs and inputs, thereby establishing a CBK model composition method.Results: To demonstrate our model composition method, we developed a complex composite CBK model from 42 CBK submodels. The resulting model called CM‐IPP is used to compute life‐gain estimates for individuals based their personal characteristics. Our result is an externalized, highly modularized CM‐IPP implementation that can be distributed and made runnable in any common server environment.Discussion: CBK model composition using compound digital objects and the distributed computing technologies is feasible. Our method of model composition might be usefully extended to bring about large ecosystems of distinct CBK models that can be fitted and re‐fitted in various ways to form new composites. Remaining challenges related to the design of composite models include identifying appropriate model boundaries and organizing submodels to separate computational concerns while optimizing reuse potential.Conclusion: Learning health systems need methods for combining CBK models from a variety of sources to create more complex and useful composite models. It is feasible to leverage Knowledge Objects and common API methods in combination to compose CBK models into complex composite models.


  • Open Access

    A Scalable Service to Improve Health Care Quality Through Precision Audit and Feedback: Proposal for a Randomized Controlled Trial

    by Zach Landis-Lewis, Allen Flynn, Allison Janda, Nirav Shah

    Background: Health care delivery organizations lack evidence-based strategies for using quality measurement data to improve performance. Audit and feedback (A&F), the delivery of clinical performance summaries to providers, demonstrates the potential for large effects on clinical practice but is currently implemented as a blunt one size fits most intervention. Each provider in a care setting typically receives a performance summary of identical metrics in a common format despite the growing recognition that precisionizing interventions hold significant promise in improving their impact. A precision approach to A&F prioritizes the display of information in a single metric that, for each recipient, carries the highest value for performance improvement, such as when the metric’s level drops below a peer benchmark or minimum standard for the first time, thereby revealing an actionable performance gap. Furthermore, precision A&F uses an optimal message format (including framing and visual displays) based on what is known about the recipient and the intended gist meaning being communicated to improve message interpretation while reducing the cognitive processing burden. Well-established psychological principles, frameworks, and theories form a feedback intervention knowledge base to achieve precision A&F. From an informatics perspective, precision A&F requires a knowledge-based system that enables mass customization by representing knowledge configurable at the group and individual levels. Objective: This study aims to implement and evaluate a demonstration system for precision A&F in anesthesia care and to assess the effect of precision feedback emails on care quality and outcomes in a national quality improvement consortium. Methods: We propose to achieve our aims by conducting 3 studies: a requirements analysis and preferences elicitation study using human-centered design and conjoint analysis methods, a software service development and implementation study, and a cluster randomized controlled trial of a precision A&F service with a concurrent process evaluation. This study will be conducted with the Multicenter Perioperative Outcomes Group, a national anesthesia quality improvement consortium with >60 member hospitals in >20 US states. This study will extend the Multicenter Perioperative Outcomes Group quality improvement infrastructure by using existing data and performance measurement processes. Results: The proposal was funded in September 2021 with a 4-year timeline. Data collection for Aim 1 began in March 2022. We plan for a 24-month trial timeline, with the intervention period of the trial beginning in March 2024. Conclusions: The proposed aims will collectively demonstrate a precision feedback service developed using an open-source technical infrastructure for computable knowledge management. By implementing and evaluating a demonstration system for precision feedback, we create the potential to observe the conditions under which feedback interventions are effective. International Registered Report Identifier (IRRID): PRR1-10.2196/34990


  • Open Access

    A Scalable Service to Improve Health Care Quality Through Precision Audit and Feedback: Proposal for a Randomized Controlled Trial (Preprint)

    by Zach Landis-Lewis, Allen Flynn, Allison Janda, Nirav Shah

    BACKGROUND Health care delivery organizations lack evidence-based strategies for using quality measurement data to improve performance. Audit and feedback (A&F), the delivery of clinical performance summaries to providers, demonstrates the potential for large effects on clinical practice but is currently implemented as a blunt one size fits most intervention. Each provider in a care setting typically receives a performance summary of identical metrics in a common format despite the growing recognition that precisionizing interventions hold significant promise in improving their impact. A precision approach to A&F prioritizes the display of information in a single metric that, for each recipient, carries the highest value for performance improvement, such as when the metric’s level drops below a peer benchmark or minimum standard for the first time, thereby revealing an actionable performance gap. Furthermore, precision A&F uses an optimal message format (including framing and visual displays) based on what is known about the recipient and the intended gist meaning being communicated to improve message interpretation while reducing the cognitive processing burden. Well-established psychological principles, frameworks, and theories form a feedback intervention knowledge base to achieve precision A&F. From an informatics perspective, precision A&F requires a knowledge-based system that enables mass customization by representing knowledge configurable at the group and individual levels. OBJECTIVE This study aims to implement and evaluate a demonstration system for precision A&F in anesthesia care and to assess the effect of precision feedback emails on care quality and outcomes in a national quality improvement consortium. METHODS We propose to achieve our aims by conducting 3 studies: a requirements analysis and preferences elicitation study using human-centered design and conjoint analysis methods, a software service development and implementation study, and a cluster randomized controlled trial of a precision A&F service with a concurrent process evaluation. This study will be conducted with the Multicenter Perioperative Outcomes Group, a national anesthesia quality improvement consortium with >60 member hospitals in >20 US states. This study will extend the Multicenter Perioperative Outcomes Group quality improvement infrastructure by using existing data and performance measurement processes. RESULTS The proposal was funded in September 2021 with a 4-year timeline. Data collection for Aim 1 began in March 2022. We plan for a 24-month trial timeline, with the intervention period of the trial beginning in March 2024. CONCLUSIONS The proposed aims will collectively demonstrate a precision feedback service developed using an open-source technical infrastructure for computable knowledge management. By implementing and evaluating a demonstration system for precision feedback, we create the potential to observe the conditions under which feedback interventions are effective. INTERNATIONAL REGISTERED REPORT PRR1-10.2196/34990