Carlas S. Smith
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Carlas S. Smith has a total of 171 co-authors. Here are the top co-authors by number of shared publications:
Shih-Te Hung
Delft Center for Systems and Control, Delft University of Technology, Delft, The Netherlands
14 shared publicationsJelmer Cnossen
Delft University of Technology, Delft Center for Systems and Control
11 shared publicationsDaniel Fan
Delft Center for Systems and Control, Delft University of Technology, Delft, The Netherlands
8 shared publicationsDylan Kalisvaart
5 shared publications- Kirti Prakash
National Physical Laboratory, Teddington, UK
5 shared publications - Daniel Spengler
Delft Center for Systems and Control, Delft University of Technology, Delft, The Netherlands
4 shared publications
Latest Publications
- Open Access
- 23 September 2026
- Published by Elsevier in Biophysical Reports
- Vol. 6 (4)
Quantifying the spatio-temporal image degradation under motion blur in fluorescence microscopy
- 23 September 2026
- Published by Elsevier in Biophysical Reports
- Vol. 6 (4)
Open AccessQuantifying the spatio-temporal image degradation under motion blur in fluorescence microscopy
- Open Access
- 1 July 2026
- Published by Springer Nature in Communications Biology
- Vol. 9 (1) , 879
Publisher Correction: CLEAR-IT, a framework for contrastive learning to capture the immune composition of tumor microenvironments
- 1 July 2026
- Published by Springer Nature in Communications Biology
- Vol. 9 (1) , 879
Open AccessPublisher Correction: CLEAR-IT, a framework for contrastive learning to capture the immune composition of tumor microenvironments
- Open Access
System Identification and Control for Optogenetics in Mammalian Nucleocytoplasmic Transport
Optogenetics enables experiments in out-of-equilibrium conditions to clarify biological mechanisms and quantify biophysical parameters. However, modelling and control techniques to study mammalian cell biology under optogenetic perturbation remain underutilised. Here, we benchmark these methods within mammalian cells by steering nucleocytoplasmic transport via the optogenetic LEXY protein in outcome-driven microscopy. First, we employ system identification to obtain models that predict transport dynamics by minimising the prediction error. We quantify this prediction accuracy for one biophysical model and two black-box models. Second, we evaluate closed-loop control efficacy by steering transport along a predefined trajectory using model-free Proportional Integral (PI) control, model-based Linear Quadratic Regulation (LQR) and Model Predictive Control (MPC). Both the predictive models and the applied control techniques demonstrate robust performance against cell-to-cell variation. This biological variation is quantified by the parameter distributions obtained from model identification with single-cell trajectories. While we show that model-free techniques such as PI and gain-scheduled PI achieve steering without explict model knowledge, predictive architectures offer better performance under this cell-to-cell variation and time-varying setpoints. Moreover, black-box predictive accuracy suggests that this model-based control is possible, even when explicit mechanistic understanding is missing. Ultimately, we demonstrate that predictive modelling and optogenetics enable quantitative characterisation and precise manipulation of mammalian cells, while offering practical guidelines for the implementation of these techniques.
Open AccessSystem Identification and Control for Optogenetics in Mammalian Nucleocytoplasmic Transport
Optogenetics enables experiments in out-of-equilibrium conditions to clarify biological mechanisms and quantify biophysical parameters. However, modelling and control techniques to study mammalian cell biology under optogenetic perturbation remain underutilised. Here, we benchmark these methods within mammalian cells by steering nucleocytoplasmic transport via the optogenetic LEXY protein in outcome-driven microscopy. First, we employ system identification to obtain models that predict transport dynamics by minimising the prediction error. We quantify this prediction accuracy for one biophysical model and two black-box models. Second, we evaluate closed-loop control efficacy by steering transport along a predefined trajectory using model-free Proportional Integral (PI) control, model-based Linear Quadratic Regulation (LQR) and Model Predictive Control (MPC). Both the predictive models and the applied control techniques demonstrate robust performance against cell-to-cell variation. This biological variation is quantified by the parameter distributions obtained from model identification with single-cell trajectories. While we show that model-free techniques such as PI and gain-scheduled PI achieve steering without explict model knowledge, predictive architectures offer better performance under this cell-to-cell variation and time-varying setpoints. Moreover, black-box predictive accuracy suggests that this model-based control is possible, even when explicit mechanistic understanding is missing. Ultimately, we demonstrate that predictive modelling and optogenetics enable quantitative characterisation and precise manipulation of mammalian cells, while offering practical guidelines for the implementation of these techniques.
- Open Access
- 16 April 2026
- Published by Springer Nature in Communications Biology
- Vol. 9 (1)
CLEAR-IT, a framework for contrastive learning to capture the immune composition of tumor microenvironments
Accurate phenotyping of cells in the tumor microenvironment is essential for understanding cancer biology but typically requires precise cell segmentation, limiting scalability. Here, we introduce Contrastive Learning Enabled Accurate Registration of Immune and Tumor cells (CLEAR-IT), a self-supervised framework that learns cell-level features from multiplexed images using only cell locations. CLEAR-IT encoders achieve strong linear evaluation performance, improve substantially with hyperparameter optimization, and maintain high accuracy across imaging modalities and with up to 90% fewer labels. When substituted for handcrafted features in a state-of-the-art classifier, CLEAR-IT features yield higher performance, and their combination enables comparable accuracy with less than half of the labeled data otherwise required. The learned representations also support prognostic modeling: using annotations from a single patient, CLEAR-IT-based phenotyping identifies survival-associated tissue features that generalize across two cohorts and modalities. CLEAR-IT provides a segmentation-light, label-efficient approach for scalable cell phenotyping and enhances existing workflows in digital pathology and tumor microenvironment analysis.
- 16 April 2026
- Published by Springer Nature in Communications Biology
- Vol. 9 (1)
Open AccessCLEAR-IT, a framework for contrastive learning to capture the immune composition of tumor microenvironments
Accurate phenotyping of cells in the tumor microenvironment is essential for understanding cancer biology but typically requires precise cell segmentation, limiting scalability. Here, we introduce Contrastive Learning Enabled Accurate Registration of Immune and Tumor cells (CLEAR-IT), a self-supervised framework that learns cell-level features from multiplexed images using only cell locations. CLEAR-IT encoders achieve strong linear evaluation performance, improve substantially with hyperparameter optimization, and maintain high accuracy across imaging modalities and with up to 90% fewer labels. When substituted for handcrafted features in a state-of-the-art classifier, CLEAR-IT features yield higher performance, and their combination enables comparable accuracy with less than half of the labeled data otherwise required. The learned representations also support prognostic modeling: using annotations from a single patient, CLEAR-IT-based phenotyping identifies survival-associated tissue features that generalize across two cohorts and modalities. CLEAR-IT provides a segmentation-light, label-efficient approach for scalable cell phenotyping and enhances existing workflows in digital pathology and tumor microenvironment analysis.
- Open Access
- 23 December 2025
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Closed-loop optogenetic control of cell biology enables outcome-driven microscopy
Smart microscopy is transforming biological imaging by integrating real-time analysis with adaptive acquisition to enhance imaging efficiency. Whereas many emerging implementations are event-driven and focus on on-demand data acquisition to reduce phototoxicity, we here present ‘outcome-driven’ microscopy, a framework combining smart microscopy with optogenetics to control cell biological processes and achieve predefined outcomes. We validate this approach using light-based control of cell migration and nucleocytoplasmic transport, demonstrating robust spatiotemporal control of cellular behaviour in single cells and in cell populations.
- 23 December 2025
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Open AccessClosed-loop optogenetic control of cell biology enables outcome-driven microscopy
Smart microscopy is transforming biological imaging by integrating real-time analysis with adaptive acquisition to enhance imaging efficiency. Whereas many emerging implementations are event-driven and focus on on-demand data acquisition to reduce phototoxicity, we here present ‘outcome-driven’ microscopy, a framework combining smart microscopy with optogenetics to control cell biological processes and achieve predefined outcomes. We validate this approach using light-based control of cell migration and nucleocytoplasmic transport, demonstrating robust spatiotemporal control of cellular behaviour in single cells and in cell populations.
- Open Access
- 2 December 2025
- Published by Elsevier in Forensic Science International
- Vol. 379, 112714
Reducing manual labour in forensic microtrace recognition with deep learning
- 2 December 2025
- Published by Elsevier in Forensic Science International
- Vol. 379, 112714
Open AccessReducing manual labour in forensic microtrace recognition with deep learning
- Open Access
- 15 May 2025
- Published by The Company of Biologists in Journal of Cell Science
- Vol. 138 (10)
Resolution in super-resolution microscopy – facts, artifacts, technological advancements and biological applications
Super-resolution microscopy (SRM) has undeniable potential for scientific discovery, yet still presents many challenges that hinder its widespread adoption, including technical trade-offs between resolution, speed and photodamage, as well as limitations in imaging live samples and larger, more complex biological structures. Furthermore, SRM often requires specialized expertise and complex instrumentation, which can deter biologists from fully embracing the technology. In this Perspective, a follow-up to our recent Q&A article, we aim to demystify these challenges by addressing common questions and misconceptions surrounding SRM. Experts offer practical insights into how biologists can maximize the benefits of SRM while navigating issues such as photobleaching, image artifacts and the limitations of existing techniques. We also highlight recent developments in SRM that continue to push the boundaries of resolution. Our goal is to equip researchers with the crucial knowledge they need to harness the full potential of SRM.
- 15 May 2025
- Published by The Company of Biologists in Journal of Cell Science
- Vol. 138 (10)
Open AccessResolution in super-resolution microscopy – facts, artifacts, technological advancements and biological applications
Super-resolution microscopy (SRM) has undeniable potential for scientific discovery, yet still presents many challenges that hinder its widespread adoption, including technical trade-offs between resolution, speed and photodamage, as well as limitations in imaging live samples and larger, more complex biological structures. Furthermore, SRM often requires specialized expertise and complex instrumentation, which can deter biologists from fully embracing the technology. In this Perspective, a follow-up to our recent Q&A article, we aim to demystify these challenges by addressing common questions and misconceptions surrounding SRM. Experts offer practical insights into how biologists can maximize the benefits of SRM while navigating issues such as photobleaching, image artifacts and the limitations of existing techniques. We also highlight recent developments in SRM that continue to push the boundaries of resolution. Our goal is to equip researchers with the crucial knowledge they need to harness the full potential of SRM.
- Open Access
Reducing Manual Labour in Forensic Microtrace Recognition with Deep Learning
Forensic microtrace investigation relies on time- and labor-intensive microscopic analyses. To aid forensic experts in their investigations, an image recognition model for microtrace localisation and classification is needed. In this work, we use deep learning to automate trace recognition in images captured with automated microscopy. We localise and classify fibres, hairs, skin, glass and sand in microscopy scans through pixel-wise classification of tape-lift samples. As deep learning requires extensive amounts of annotated training data, we additionally investigate various pretraining strategies to minimise the required annotation workload. We compare ImageNet pretraining, pretraining with self-supervised learning and a sequential application of these approaches. We find that pretrained models are able to reduce the required annotated data twofold compared to models trained from scratch while retaining the prediction accuracy. While our ImageNet-pretrained models outperform our self-supervised-pretrained models, we achieve the highest accuracy by combining the two approaches, resulting in a factor of 4 reduction of manual annotated microtraces or a 65 % improvement in recognition and localisation accuracy (mean intersection over union increases from 0.34 to 0.56 due to pretraining) when training on only 2.2 dm 2 of annotated tape lift scans. Our model is, therefore, the method of choice for the automatic analysis of large forensic microtrace scans.
Open AccessReducing Manual Labour in Forensic Microtrace Recognition with Deep Learning
Forensic microtrace investigation relies on time- and labor-intensive microscopic analyses. To aid forensic experts in their investigations, an image recognition model for microtrace localisation and classification is needed. In this work, we use deep learning to automate trace recognition in images captured with automated microscopy. We localise and classify fibres, hairs, skin, glass and sand in microscopy scans through pixel-wise classification of tape-lift samples. As deep learning requires extensive amounts of annotated training data, we additionally investigate various pretraining strategies to minimise the required annotation workload. We compare ImageNet pretraining, pretraining with self-supervised learning and a sequential application of these approaches. We find that pretrained models are able to reduce the required annotated data twofold compared to models trained from scratch while retaining the prediction accuracy. While our ImageNet-pretrained models outperform our self-supervised-pretrained models, we achieve the highest accuracy by combining the two approaches, resulting in a factor of 4 reduction of manual annotated microtraces or a 65 % improvement in recognition and localisation accuracy (mean intersection over union increases from 0.34 to 0.56 due to pretraining) when training on only 2.2 dm 2 of annotated tape lift scans. Our model is, therefore, the method of choice for the automatic analysis of large forensic microtrace scans.
- Open Access
Patterned illumination enables denser deep-learning based single-molecule localization microscopy
Single-molecule localization microscopy (SMLM) improves resolution beyond diffraction limits by imaging cellular structures at the nanometer scale. Recent advances include using modulation patterns to improve localization precision, and deep learning to accurately process high-density samples with overlapping fluorophore emissions, thus improving imaging speed. A method combining these two advances, SIMCODE, is presented here, allowing high-density modulation-enhanced SMLM. SIMCODE achieved resolution improvements in high-density areas compared to SMLM, deep learning-based SMLM (DECODE), and modulation-enhanced SMLM alone (SIMFLUX). In DNA-PAINT imaging of COS-7 cells, SIMCODE showed improvements in the Fourier Ring Correlation and resolution-scaled Pearson coefficient, with overall improvement increasing as imaging buffer concentration increased five-fold. Modulation-enhanced localization microscopy combined with deep learning thus produced higher quality reconstructions at higher emitter densities (i.e., $\sim$3$\times$ the number of detected spots). This will enable faster imaging, higher labeling densities, and more flexibility in fluorophore choice, which are important for studying dynamic processes and densely labeled structures.Open AccessPatterned illumination enables denser deep-learning based single-molecule localization microscopy
Single-molecule localization microscopy (SMLM) improves resolution beyond diffraction limits by imaging cellular structures at the nanometer scale. Recent advances include using modulation patterns to improve localization precision, and deep learning to accurately process high-density samples with overlapping fluorophore emissions, thus improving imaging speed. A method combining these two advances, SIMCODE, is presented here, allowing high-density modulation-enhanced SMLM. SIMCODE achieved resolution improvements in high-density areas compared to SMLM, deep learning-based SMLM (DECODE), and modulation-enhanced SMLM alone (SIMFLUX). In DNA-PAINT imaging of COS-7 cells, SIMCODE showed improvements in the Fourier Ring Correlation and resolution-scaled Pearson coefficient, with overall improvement increasing as imaging buffer concentration increased five-fold. Modulation-enhanced localization microscopy combined with deep learning thus produced higher quality reconstructions at higher emitter densities (i.e., $\sim$3$\times$ the number of detected spots). This will enable faster imaging, higher labeling densities, and more flexibility in fluorophore choice, which are important for studying dynamic processes and densely labeled structures. - Open Access
- 1 December 2024
- Published by AIP Publishing in APL Photonics
- Vol. 9 (12)
Speckle-based 3D sub-diffraction imaging of sparse samples through a multimode fiber
A flexible multimode fiber is an exceptionally efficient tool for in vivo deep tissue imaging. Recent advances in compressive multimode fiber sensing allow for imaging with sub-diffraction spatial resolution and sub-Nyquist speed. At present, the technology is limited to imaging in a two-dimensional (2D) plane near the fiber distal facet, while in real applications it is very important to visualize three-dimensional (3D) structures. Here, we propose a new approach for fast sub-diffraction 3D imaging of sparse samples through a multimode fiber by using a single 2D scan, speckle illumination, and bucket detection. We experimentally demonstrate precise image plane location as well as 3D imaging of samples with various scattering coefficients. The full width at half maximum of the point spread function along the axial direction is three times smaller than the diffraction limit. Our study grants depth-resolving capacity to ultra-thin super-resolution fiber endoscopes for life science and medical applications.
- 1 December 2024
- Published by AIP Publishing in APL Photonics
- Vol. 9 (12)
Open AccessSpeckle-based 3D sub-diffraction imaging of sparse samples through a multimode fiber
A flexible multimode fiber is an exceptionally efficient tool for in vivo deep tissue imaging. Recent advances in compressive multimode fiber sensing allow for imaging with sub-diffraction spatial resolution and sub-Nyquist speed. At present, the technology is limited to imaging in a two-dimensional (2D) plane near the fiber distal facet, while in real applications it is very important to visualize three-dimensional (3D) structures. Here, we propose a new approach for fast sub-diffraction 3D imaging of sparse samples through a multimode fiber by using a single 2D scan, speckle illumination, and bucket detection. We experimentally demonstrate precise image plane location as well as 3D imaging of samples with various scattering coefficients. The full width at half maximum of the point spread function along the axial direction is three times smaller than the diffraction limit. Our study grants depth-resolving capacity to ultra-thin super-resolution fiber endoscopes for life science and medical applications.