HHHans W. Herrmann

Hans W. Herrmann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hans W. Herrmann has a total of 276 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design considerations and forward modeling signal levels for a high dynamic range fusion reaction history diagnostic

    by K. D. Meaney, H. Geppert-Kleinrath, R. H. Dwyer, B. H. Haines, Y. Kim, R. M. Malone, H. W. Herrmann, J. Sauppe, M. P. Springstead, C. Trosseille, et al.

    A high-dynamic-range fusion reaction history measurement would offer powerful insight into the detailed dynamic evolution, energy balance, hotspot formation, and explosion of igniting fusion hotspots. We review the design principles of potential detector choices to make such a measurement. Results from a forward model using a detector similar to the existing Gamma Reaction History diagnostic, but placed farther from the target chamber and assuming an achieved signal-to-background, are shared. The results show that an optical splitter, a high-gain photomultiplier, and modest attenuation can meet the dynamic-range measurement requirements. The multichannel plate-charge limit, space-charge requirement, voltage, and multiplexing requirement can all be met for yields up to 70 MJ.

  • Open Access

    Inferring fusion nuclear burnwidths with low gain photomultiplier impulse response functions

    by K. D. Meaney, J. Jeet, J. Carrera, E. Mariscal, D. Schlossberg, A. Moore, M. Eckart, J. Milnes, P. Hink, P. Hillyard, et al.

    When an inertial confinement fusion implosion is compressed, it maintains thermonuclear density and temperatures for a very short time scale, about 100 ps. The Gamma Reaction History diagnostic measures the time evolution of the fusion burn, but its temporal resolution is limited by the use of a photomultiplier tube (PMT) to amplify the photon signal. Multichannel plate-based PMTs have a fast (∼120 ps) full-width at half-max impulse response function (IRF), but the time scale is similar to the incoming physics signal. An analysis routine is used to remove the effect of the PMT IRF and infer the incident fusion burnwidth. With the National Ignition Facility achieving ignition and creating much brighter signals, the PMTs are run at gains three orders of magnitude lower than nominal operation. Calibration at these settings shows the PMT IRFs get ∼15% wider. Taking the gain-dependent IRF can affect the inferred nuclear burnwidths by up to ∼15%.


  • Open Access

    Separated reactant mix width across diffusion-dominated and hydrodynamically dominated interface mix in inertial confinement fusion implosions

    by K. D. Meaney, Y. Kim, N. M. Hoffman, Z. L. Mohamed, W. T. Taitano, H. W. Herrmann, H. Geppert-Kleinrath, M. P. Springstead, A. B. Zylstra, A. Leatherland, et al.

    Diffusion-dominated mix in inertial confinement fusion (ICF) is characterized where the majority of the mix occurs in the immediate fuel-shell interface while hydrodynamic-dominated mix pulls shell material from farther away into the central fuel. A thin (150 nm) separated reactants ICF mix platform is highly sensitive to the amount of mix from the first micron of shell-fuel interface. This fine-spatial resolution platform has revealed that material mix in moderate convergence ( CR ∼ 12 ) ICF implosions is dominated by a diffusion mechanism. This technique has now been expanded across a set of OMEGA ICF implosions, observing an increase in mix width and mix amount for cooler, slower, and more compressive implosions. Hydrodynamic simulations require a buoyancy-drag mix model to capture the increasing mix width, suggesting a transition between these two mix mechanisms. Published by the American Physical Society 2024


  • Open Access

    Measurements of fusion reaction history in inertially confined burning plasmas

    by Y. Kim, K. D. Meaney, H. Geppert-Kleinrath, H. W. Herrmann, T. J. Murphy, C. S. Young, N. M. Hoffman, H. J. Jorgenson, T. Morrow, D. C. Wilson, et al.

    Direct evidence of inertially confined fusion ignition appears in the abrupt temperature increase and consequent rapid increase in the thermonuclear burn rate as seen in the reaction history. The Gamma Reaction History (GRH) and Gas Cherenkov Detector (GCD) diagnostics are γ-based Cherenkov detectors that provide high quality measurements of deuterium–tritium fusion γ ray production and are, thus, capable of monitoring the thermonuclear burn rate. Temporal shifts in both peak burn time and burn width have been observed during recent high-yield shots (yields greater than 1017 neutrons) and are essential diagnostic signatures of the ignition process. While the current GRH and GCD detectors are fast enough to sense the changes of reaction history due to alpha heating, they do not have enough dynamic range to capture the onset of alpha heating. The next generation of instrumentation, GRH-15m, is proposed to increase the yield-rate coverage to measure the onset of alpha-heating.


  • Open Access

    Gamma-ray measurements for inertial confinement fusion applications

    by Yongho Kim, Hans W. Herrmann

    High-energy γ rays generated from inertial confinement fusion (ICF) experiments have become an important signature for studying the dynamics of implosion processes. Due to their high-energy and penetrating nature, γ rays are the most unperturbed fusion products, which can preserve the original birth information of the fusion process. Fusion γ rays provide a direct measure of nuclear reaction rates (unlike x rays) without being compromised by Doppler spreading (unlike neutrons). However, unambiguous γ-ray measurements for ICF study further required a decade-long period of technological development, which included a deepening understanding of fusion γ-ray characteristics and innovations in instrument performance. This review article introduces the production mechanism of the prompt and secondary γ rays and various ICF performance parameters (e.g., bang time and burn width), which can be derived from γ-ray measurement. A technical overview will be followed by summarizing γ-ray detectors fielded or proposed, especially for high-yield ICF experiments at the Omega Laser Facility and National Ignition Facility. Over the past few years, γ-ray diagnostic technologies have been extended beyond ICF research. A few examples of non-ICF applications of γ-ray detectors are introduced at the end of this article.


  • Open Access

    Publisher Correction: Burning plasma achieved in inertial fusion

    by A. B. Zylstra, O. A. Hurricane, D. A. Callahan, A. L. Kritcher, J. E. Ralph, H. F. Robey, J. S. Ross, C. V. Young, K. L. Baker, D. T. Casey, et al.


  • Top Cited Papers
    Open Access

    Burning plasma achieved in inertial fusion

    by A. B. Zylstra, O. A. Hurricane, D. A. Callahan, A. L. Kritcher, J. E. Ralph, H. F. Robey, J. S. Ross, C. V. Young, K. L. Baker, D. T. Casey, et al.

    Obtaining a burning plasma is a critical step towards self-sustaining fusion energy1. A burning plasma is one in which the fusion reactions themselves are the primary source of heating in the plasma, which is necessary to sustain and propagate the burn, enabling high energy gain. After decades of fusion research, here we achieve a burning-plasma state in the laboratory. These experiments were conducted at the US National Ignition Facility, a laser facility delivering up to 1.9 megajoules of energy in pulses with peak powers up to 500 terawatts. We use the lasers to generate X-rays in a radiation cavity to indirectly drive a fuel-containing capsule via the X-ray ablation pressure, which results in the implosion process compressing and heating the fuel via mechanical work. The burning-plasma state was created using a strategy to increase the spatial scale of the capsule2,3 through two different implosion concepts4–7. These experiments show fusion self-heating in excess of the mechanical work injected into the implosions, satisfying several burning-plasma metrics3,8. Additionally, we describe a subset of experiments that appear to have crossed the static self-heating boundary, where fusion heating surpasses the energy losses from radiation and conduction. These results provide an opportunity to study α-particle-dominated plasmas and burning-plasma physics in the laboratory.


  • Inertial-confinement fusion-plasma-based cross-calibration of the deuterium-tritium γ-to-neutron branching ratio

    by J. Jeet, A. B. Zylstra, M. Rubery, Y. Kim, K. D. Meaney, C. Forrest, V. Glebov, C. J. Horsfield, A. M. McEvoy, H. W. Herrmann

    The deuterium-tritium (D-T) γ-to-neutron branching ratio [H3(d,γ)He5/H3(d,n)He4] has been determined previously under inertial-confinement fusion (ICF) conditions and in beam-target based experiments. In the former case, neutron-induced backgrounds are mitigated compared to the latter due to the short pulse nature of ICF implosions and the use of gas Cherenkov γ-ray detectors. An added benefit of ICF based measurements is the ability to achieve lower center-of-mass energies as compared to accelerators. Previous ICF based experiments however report a large uncertainty in the D-T γ-to-neutron branching ratio of ≈48%, which arises from the necessity of an absolute detector calibration and/or a cross-calibration against the D-He3 γ-to-proton branching ratio. A more precise value for the branching ratio based on data taken at the OMEGA laser facility is reported here, which relies on a cross-calibration against the better known C12 neutron inelastic scattering cross section. A D-T branching ratio value of (4.6±0.6)×10−5 is determined by this method.


  • Total fusion yield measurements using deuterium–tritium gamma rays

    by K. D. Meaney, Y. Kim, H. Geppert-Kleinrath, H. W. Herrmann, A. S. Moore, E. P. Hartouni, D. J. Schlossberg, E. Mariscal, J. Carrera, J. A. Church

    The deuterium–tritium (DT) fusion reaction, D(T,γ)5He , has a rare (4.2 ×10−5 ) branching ratio that releases a ∼16 MeV gamma ray instead of the more common 14.1 MeV fusion neutron. These fusion gamma rays can be used as a complementary source of measuring the net fusion yield of experiments. Fusion gamma rays have the advantage of having negligible Doppler broadening, being isotropic and less down-scattered compared to fusion neutrons. At the National Ignition Facility, the DT fusion gamma rays are measured by the Gamma Reaction History diagnostic that thresholds to only measure >10 MeV gamma rays. After removing a ∼12% contribution from neutron capture interactions in deuterium, D(n,γ)T , and carbon, 12C(n,γ)13C , the deviation between GRH measurements and neutron-based yield measurements has been reduced to 10%. Further improvements are needed for detailed physics comparison.


  • C13(n,2nγ)C12 γ -ray production in the 14–16 MeV incident neutron energy range

    by A. M. McEvoy, H. W. Herrmann, Y. Kim, T. S. Sedillo, H. Geppert-Kleinrath, C. R. Brune, T. N. Massey, A. V. Voinov, C. E. Parker, M. S. Rubery, et al.

    γ-ray emission from C12 and C13 samples irradiated with deuterium-tritium fusion neutrons was experimentally measured at the Omega Laser Facility and at the Ohio University Edwards Accelerator Laboratory. The intent of these measurements was to determine the feasibility of using C13-based plastic ablators with embedded C12 layers for “dark mix” diagnosis of inertial confinement fusion implosions. Spectrally resolved measurements at Ohio University identified significant 4.44-MeV γ-ray emission from the C13(n,2nγ)C12-L1 reaction channel. The recorded 4.44-MeV C13 signal was compared against emission from an identically irradiated C12 target with known C12(n,n′γ)C12-L1 cross section, which resulted in an average C13(n,2nγ)C12-L1 cross section of 117 ± 17 mb over the incident neutron energy distribution range from 14.4 to 15.8 MeV. Integrated C13 γ-ray signals above 2.9 MeV recorded with the Gas Cherenkov Detector at Omega exceeded MCNP6.1 predictions by a factor of 3. The additional signal was attributed to 4.44-MeV γs resulting in an inferred C13(n,2nγ)C12-L1 cross section of 95±11 mb at 14.1-MeV average incident neutron energy. As a result, the C13-based “dark mix” diagnostic concept was deemed infeasible.