Kenji Sueyoshi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kenji Sueyoshi has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Tatsuro Endo
Department of Applied Chemistry, Graduate School of Engineering, Osaka Metropolitan University, 1-1 Gakuen-cho, Naka-ku, Sakai, Osaka, 599-8531 Japan
15 shared publications - Hideaki Hisamoto
Department of Applied Chemistry, Graduate School of Engineering, Osaka Metropolitan University, 1-1 Gakuen-cho, Naka-ku, Sakai, Osaka, 599-8531 Japan
10 shared publications Hideaki Hisamoto
Graduate School of Engineering, Osaka Prefecture University, Osaka, Japan
5 shared publications- Hirotaka Yamada
Department of Applied Chemistry, Graduate School of Engineering, Osaka Prefecture University, Sakai 599-8531, Japan
3 shared publications - Daiki Kawasaki
Department of Applied Chemistry, Graduate School of Engineering, Osaka Prefecture University, Sakai 599-8531, Japan
2 shared publications Terence G. Henares
Graduate School of Engineering, Osaka Prefecture University, 1-1 Gakuen-cho Nakaku, Sakai City, Osaka 599-8531, Japan.
2 shared publications
Latest Publications
- Open Access
- 28 March 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (4) , 200
Imprinted Photonic Crystal-Film-Based Smartphone-Compatible Label-Free Optical Sensor for SARS-CoV-2 Testing
The coronavirus disease (COVID-19) caused by SARS-CoV-2 has caused a global pandemic. To manage and control the spread of the infection, it is crucial to develop and implement technologies for the early identification of infected individuals and rapid informatization in communities. For the realization of such a technology, a widely available and highly usable sensor for sensitive and specific assay of the virus plays a fundamental role. In this study, we developed an optical sensor based on an imprinted photonic crystal film (IPCF) for quick, simple, and cost-effective detection of SARS-CoV-2 spike protein in artificial saliva. Our IPCF sensor enabled label-free and highly sensitive detection with a smartphone-equipped optical setup. The IPCF surface was functionalized with an anti-SARS-CoV-2 spike protein antibody for immunoassay. We evaluated the specificity and sensitivity of the IPCF sensor for quantitative detection of the spike protein in artificial saliva using simple reflectometry with a spectrometer-equipped optical setup. Specific and quantitative detection of the spike protein was successfully achieved, with a low detection limit of 429 fg/mL. In the demonstration of reflectometric detection with a smartphone-equipped setup, the sensitivity was comparable with that with a spectrometer-equipped setup. The test result is returned immediately and can be saved to cloud storage. In addition, it costs less than USD 1 for one IPCF to be used for diagnosis. Thus, the developed IPCF has the potential to realize a widely available and highly usable sensor.
- 28 March 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (4) , 200
Open AccessImprinted Photonic Crystal-Film-Based Smartphone-Compatible Label-Free Optical Sensor for SARS-CoV-2 Testing
The coronavirus disease (COVID-19) caused by SARS-CoV-2 has caused a global pandemic. To manage and control the spread of the infection, it is crucial to develop and implement technologies for the early identification of infected individuals and rapid informatization in communities. For the realization of such a technology, a widely available and highly usable sensor for sensitive and specific assay of the virus plays a fundamental role. In this study, we developed an optical sensor based on an imprinted photonic crystal film (IPCF) for quick, simple, and cost-effective detection of SARS-CoV-2 spike protein in artificial saliva. Our IPCF sensor enabled label-free and highly sensitive detection with a smartphone-equipped optical setup. The IPCF surface was functionalized with an anti-SARS-CoV-2 spike protein antibody for immunoassay. We evaluated the specificity and sensitivity of the IPCF sensor for quantitative detection of the spike protein in artificial saliva using simple reflectometry with a spectrometer-equipped optical setup. Specific and quantitative detection of the spike protein was successfully achieved, with a low detection limit of 429 fg/mL. In the demonstration of reflectometric detection with a smartphone-equipped setup, the sensitivity was comparable with that with a spectrometer-equipped setup. The test result is returned immediately and can be saved to cloud storage. In addition, it costs less than USD 1 for one IPCF to be used for diagnosis. Thus, the developed IPCF has the potential to realize a widely available and highly usable sensor.
- 22 March 2022
- Published by Springer Nature in Analytical Sciences
- Vol. 38 (6) , 851-859
Evaluation of the interactions between oligonucleotides and small molecules by partial filling–nonequilibrium affinity capillary electrophoresis
Recently, high-throughput analysis with minimal reagent consumption has been desired to assess interactions between drug candidates and disease-related oligonucleotides. To realize an ideal assay for drug screening, a rapid assay based on affinity capillary electrophoresis was generated to reduce the consumption of samples/reagents by a partial-filling technique under nonequilibrium conditions. In the proposed method, the first sample, oligonucleotide as a ligand, and second sample zones were injected into a capillary with spacers of background solution between the samples and oligonucleotide zones. After applying voltages, only the second sample zone passed through the partially filled oligonucleotide zone, resulting in variations in the peak parameters owing to this interaction. The electropherograms obtained were analyzed using equilibrium, reaction kinetics, and moment theories. In the interaction analyses between small molecules and DNA aptamers, only the small molecules binding to the aptamer showed significant changes in their peak heights and shapes. The estimated kinetic parameters were in good agreement with the reported values, indicating the applicability of the proposed method for drug screening. When interactions between drug candidates and disease-related RNAs were analyzed, one of the candidates showed remarkable variation in the peak parameters upon the addition of potassium ions. Consequently, the proposed method could be one of the ideal assays for drug screening. Graphical abstract
- 22 March 2022
- Published by Springer Nature in Analytical Sciences
- Vol. 38 (6) , 851-859
Evaluation of the interactions between oligonucleotides and small molecules by partial filling–nonequilibrium affinity capillary electrophoresis
Recently, high-throughput analysis with minimal reagent consumption has been desired to assess interactions between drug candidates and disease-related oligonucleotides. To realize an ideal assay for drug screening, a rapid assay based on affinity capillary electrophoresis was generated to reduce the consumption of samples/reagents by a partial-filling technique under nonequilibrium conditions. In the proposed method, the first sample, oligonucleotide as a ligand, and second sample zones were injected into a capillary with spacers of background solution between the samples and oligonucleotide zones. After applying voltages, only the second sample zone passed through the partially filled oligonucleotide zone, resulting in variations in the peak parameters owing to this interaction. The electropherograms obtained were analyzed using equilibrium, reaction kinetics, and moment theories. In the interaction analyses between small molecules and DNA aptamers, only the small molecules binding to the aptamer showed significant changes in their peak heights and shapes. The estimated kinetic parameters were in good agreement with the reported values, indicating the applicability of the proposed method for drug screening. When interactions between drug candidates and disease-related RNAs were analyzed, one of the candidates showed remarkable variation in the peak parameters upon the addition of potassium ions. Consequently, the proposed method could be one of the ideal assays for drug screening. Graphical abstract
- Open Access
- 3 February 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (2) , 257
Fabrication of Metal-Insulator-Metal Nanostructures Composed of Au-MgF2-Au and Its Potential in Responding to Two Different Factors in Sample Solutions Using Individual Plasmon Modes
In this paper, metal–insulator–metal (MIM) nanostructures, which were designed to exhibit two absorption peaks within 500–1100 nm wavelength range, were fabricated using magnesium difluoride (MgF2) as the insulator layer. Since the MIM nanostructures have two plasmon modes corresponding to the absorption peaks, they independently responded to the changes in two phases: the surrounding medium and the inside insulator layer, the structure is expected to obtain multiple information from sample solution: refractive index (RI) and molecular interaction between solution components and the insulator layer. The fabricated MIM nanostructure had a diameter of 139.6 ± 2.8 nm and a slope of 70°, and exhibited absorption peaks derived from individual plasmon modes at the 719 and 907 nm wavelengths. The evaluation of the response to surrounding solution component of the MIM nanostructures revealed a linear response of one plasmon mode toward the RI of the surrounding medium and a large blue shift of the other plasmon mode under conditions where glycerol was present at high concentration. From optical simulation and the evaluation of the MgF2 fabricated by deposition, the blue shift was expected to be due to the swelling of MgF2 interacting with the hydroxyl groups abundantly included in the glycerol molecules. The results indicated the individual responses of two plasmon modes in MIM nanostructures toward medium components, and brought the prospect for the simultaneous measurement of multiple elements using two or more plasmon modes.
- 3 February 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (2) , 257
Open AccessFabrication of Metal-Insulator-Metal Nanostructures Composed of Au-MgF2-Au and Its Potential in Responding to Two Different Factors in Sample Solutions Using Individual Plasmon Modes
In this paper, metal–insulator–metal (MIM) nanostructures, which were designed to exhibit two absorption peaks within 500–1100 nm wavelength range, were fabricated using magnesium difluoride (MgF2) as the insulator layer. Since the MIM nanostructures have two plasmon modes corresponding to the absorption peaks, they independently responded to the changes in two phases: the surrounding medium and the inside insulator layer, the structure is expected to obtain multiple information from sample solution: refractive index (RI) and molecular interaction between solution components and the insulator layer. The fabricated MIM nanostructure had a diameter of 139.6 ± 2.8 nm and a slope of 70°, and exhibited absorption peaks derived from individual plasmon modes at the 719 and 907 nm wavelengths. The evaluation of the response to surrounding solution component of the MIM nanostructures revealed a linear response of one plasmon mode toward the RI of the surrounding medium and a large blue shift of the other plasmon mode under conditions where glycerol was present at high concentration. From optical simulation and the evaluation of the MgF2 fabricated by deposition, the blue shift was expected to be due to the swelling of MgF2 interacting with the hydroxyl groups abundantly included in the glycerol molecules. The results indicated the individual responses of two plasmon modes in MIM nanostructures toward medium components, and brought the prospect for the simultaneous measurement of multiple elements using two or more plasmon modes.
- Open Access
- 28 October 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (11) , 1323
Modulating Optical Characteristics of Nanoimprinted Plasmonic Device by Re-Shaping Process of Polymer Mold
Metal nanostructures exhibit specific optical characteristics owing to their localized surface plasmon resonance (LSPR) and have been studied for applications in various optical devices. The LSPR property strongly depends on the size and shape of metal nanostructures; thus, plasmonic devices must be designed and fabricated according to their uses. Nanoimprint lithography (NIL) is an effective process for repeatedly fabricating metal nanostructures with controlled sizes and shapes and require optical properties. NIL is a powerful method for mass-producible, low-cost, and large-area fabrication. However, the process lacks flexibility in adjusting the size and shape according to the desirable optical characteristics because the size and shape of metal nanostructures are determined by a single corresponding mold. Here, we conducted a re-shaping process through the air-plasma etching of a polymer’s secondary mold (two-dimensional nanopillar array made of cyclo-olefin polymer (COP)) to modulate the sizes and shapes of nanopillars; then, we controlled the spectral characteristics of the imprinted plasmonic devices. The relationship between the structural change of the mold, which was based on etching time, and the optical characteristics of the corresponding plasmonic device was evaluated through experiments and simulations. According to evaluation results, the diameter of the nanopillar was controlled from 248 to 139 nm due to the etching time and formation of a pit structure. Consequently, the spectral properties changed, and responsivity to the surrounding dielectric environment was improved. Therefore, plasmonic devices based on the re-shaped COP mold exhibited a high responsivity to a refractive index of 906 nm/RIU at a wavelength of 625 nm.
- 28 October 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (11) , 1323
Open AccessModulating Optical Characteristics of Nanoimprinted Plasmonic Device by Re-Shaping Process of Polymer Mold
Metal nanostructures exhibit specific optical characteristics owing to their localized surface plasmon resonance (LSPR) and have been studied for applications in various optical devices. The LSPR property strongly depends on the size and shape of metal nanostructures; thus, plasmonic devices must be designed and fabricated according to their uses. Nanoimprint lithography (NIL) is an effective process for repeatedly fabricating metal nanostructures with controlled sizes and shapes and require optical properties. NIL is a powerful method for mass-producible, low-cost, and large-area fabrication. However, the process lacks flexibility in adjusting the size and shape according to the desirable optical characteristics because the size and shape of metal nanostructures are determined by a single corresponding mold. Here, we conducted a re-shaping process through the air-plasma etching of a polymer’s secondary mold (two-dimensional nanopillar array made of cyclo-olefin polymer (COP)) to modulate the sizes and shapes of nanopillars; then, we controlled the spectral characteristics of the imprinted plasmonic devices. The relationship between the structural change of the mold, which was based on etching time, and the optical characteristics of the corresponding plasmonic device was evaluated through experiments and simulations. According to evaluation results, the diameter of the nanopillar was controlled from 248 to 139 nm due to the etching time and formation of a pit structure. Consequently, the spectral properties changed, and responsivity to the surrounding dielectric environment was improved. Therefore, plasmonic devices based on the re-shaped COP mold exhibited a high responsivity to a refractive index of 906 nm/RIU at a wavelength of 625 nm.
- 30 April 2021
- Published by Springer Nature in Analytical Sciences
- Vol. 37 (6) , 799-802
Fractionation of Single-stranded DNAs with/without Stable Preorganized Structures Using Capillary Sieving Electrophoresis for Aptamer Selection
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 30 April 2021
- Published by Springer Nature in Analytical Sciences
- Vol. 37 (6) , 799-802
Fractionation of Single-stranded DNAs with/without Stable Preorganized Structures Using Capillary Sieving Electrophoresis for Aptamer Selection
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- Open Access
- 9 April 2021
- Published by Springer Nature in Analytical Sciences
- Vol. 37 (10) , 1439-1446
Direct Measurement of Initial Rate of Enzyme Reaction by Electrokinetic Filtration Using a Hydrogel-plugged Capillary Device
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 9 April 2021
- Published by Springer Nature in Analytical Sciences
- Vol. 37 (10) , 1439-1446
Open AccessDirect Measurement of Initial Rate of Enzyme Reaction by Electrokinetic Filtration Using a Hydrogel-plugged Capillary Device
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 15 February 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (9) , 4143-4148
Lipophilic Fluorescent Dye Liquids: Förster Resonance Energy Transfer-Based Fluorescence Amplification for Ion Selective Optical Sensors Based on a Solvent Polymeric Membrane
Optical sensors based on solvent polymeric membranes have the potential to measure analytes present in an aqueous solution through the development of a tailored method for a specific target. However, limits in the concentrations of the component dyes have prevented improvements in sensitivity. We propose a Förster resonance energy transfer (FRET)-based fluorescence amplification system for ion-selective optical sensors using a highly fluorescent liquid material composed of a lipophilic phosphonium cation and a pyrene modifying sulfonate anion ([P66614][HP-SO3]), as both the plasticizer and donor, in addition to a combination of the lipophilic phosphonium cation and the fluorescein dodecyl ester anion ([P66614][12-FL]) as the fluorescent sensing dye acceptor. For ion extraction-based sensing, the donor and acceptor were retained in the plasticized PVC membrane with negligible leaching upon exposure to acidic and basic aqueous solutions. Systematic investigation of the donor and acceptor ratios clarified the effect of the amplification factor and the sensitivity of the sensor. At an acceptor doping level of 0.5 mol % (vs donor), an approximately 22-fold higher sensitivity was obtained compared to that of a conventional PVC membrane optical sensor. During ion measurement based on the coextraction of protons and anions, selectivity following the Hofmeister order was observed, which was controlled by the addition of ionophores. The proposed FRET system based on a lipophilic fluorescent liquid material has the potential to significantly improve the sensitivities of optical sensors using solvent polymeric membranes with high selectivities for various target analytes.
- 15 February 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (9) , 4143-4148
Lipophilic Fluorescent Dye Liquids: Förster Resonance Energy Transfer-Based Fluorescence Amplification for Ion Selective Optical Sensors Based on a Solvent Polymeric Membrane
Optical sensors based on solvent polymeric membranes have the potential to measure analytes present in an aqueous solution through the development of a tailored method for a specific target. However, limits in the concentrations of the component dyes have prevented improvements in sensitivity. We propose a Förster resonance energy transfer (FRET)-based fluorescence amplification system for ion-selective optical sensors using a highly fluorescent liquid material composed of a lipophilic phosphonium cation and a pyrene modifying sulfonate anion ([P66614][HP-SO3]), as both the plasticizer and donor, in addition to a combination of the lipophilic phosphonium cation and the fluorescein dodecyl ester anion ([P66614][12-FL]) as the fluorescent sensing dye acceptor. For ion extraction-based sensing, the donor and acceptor were retained in the plasticized PVC membrane with negligible leaching upon exposure to acidic and basic aqueous solutions. Systematic investigation of the donor and acceptor ratios clarified the effect of the amplification factor and the sensitivity of the sensor. At an acceptor doping level of 0.5 mol % (vs donor), an approximately 22-fold higher sensitivity was obtained compared to that of a conventional PVC membrane optical sensor. During ion measurement based on the coextraction of protons and anions, selectivity following the Hofmeister order was observed, which was controlled by the addition of ionophores. The proposed FRET system based on a lipophilic fluorescent liquid material has the potential to significantly improve the sensitivities of optical sensors using solvent polymeric membranes with high selectivities for various target analytes.
- Open Access
- 28 April 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (5) , 458
Size Sorting of Exosomes by Tuning the Thicknesses of the Electric Double Layers on a Micro-Nanofluidic Device
Exosomes, a type of extracellular vesicle with a diameter of 30–150 nm, perform key biological functions such as intercellular communication. Recently, size sorting of exosomes has received increasing attention in order to clarify the correlation between their size and components. However, such sorting remains extremely difficult. Here, we propose to sort their size by controlling their electrokinetic migration in nanochannels in a micro-nanofluidic device, which is achieved by tuning the thickness of the electric double layers in the nanochannels. This approach was demonstrated experimentally for exosomes smaller than 250 nm. Using different running buffer concentrations (1 × 10−3, 1 × 10−4, and 1 × 10−5 M), most of the exosomes larger than 140, 110, and 80 nm were successfully cut off at the downstream of the nanochannels, respectively. Therefore, it is clarified that the proposed method is applicable for the size sorting of exosomes.
- 28 April 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (5) , 458
Open AccessSize Sorting of Exosomes by Tuning the Thicknesses of the Electric Double Layers on a Micro-Nanofluidic Device
Exosomes, a type of extracellular vesicle with a diameter of 30–150 nm, perform key biological functions such as intercellular communication. Recently, size sorting of exosomes has received increasing attention in order to clarify the correlation between their size and components. However, such sorting remains extremely difficult. Here, we propose to sort their size by controlling their electrokinetic migration in nanochannels in a micro-nanofluidic device, which is achieved by tuning the thickness of the electric double layers in the nanochannels. This approach was demonstrated experimentally for exosomes smaller than 250 nm. Using different running buffer concentrations (1 × 10−3, 1 × 10−4, and 1 × 10−5 M), most of the exosomes larger than 140, 110, and 80 nm were successfully cut off at the downstream of the nanochannels, respectively. Therefore, it is clarified that the proposed method is applicable for the size sorting of exosomes.
- 10 July 2019
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 2 (8) , 4983-4990
Core–Shell-Structured Gold Nanocone Array for Label-Free DNA Sensing
- 10 July 2019
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 2 (8) , 4983-4990
Core–Shell-Structured Gold Nanocone Array for Label-Free DNA Sensing
- Open Access
- 17 August 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (8) , 410
Design and Fabrication of a Visible-Light-Compatible, Polymer-Based Photonic Crystal Resonator and Waveguide for Sensing Applications
In this paper, we have proposed a polymer-based photonic crystal (PhC) resonator, with multiple sizes of cavities, and a waveguide to be used as highly sensitive optical sensor components. Properties of the proposed PhC were simulated by the finite-difference time-domain method, and the polymer-based PhC resonator and waveguide were fabricated on a photoresist (polymer) by electron beam lithography, which was prepared on an Au-layer-deposited Si substrate. We detected the resonant light that penetrated through the waveguide and was trapped in the PhC resonator. Optical characteristics of the fabricated PhC were evaluated by detecting the polymer layer deposition process by using the layer-by-layer (LbL) method to deposit polymer layers. As a result, by using an optimized design of a polymer-based PhC resonator with a long cavity (equivalent to a defect of three holes), the PhC structure changes caused by LbL deposition lead to changes in resonant light wavelength (peak shift: 5.26 nm/layer). Therefore, we suggest that a PhC resonator and a waveguide is applicable as an optical sensor.
- 17 August 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (8) , 410
Open AccessDesign and Fabrication of a Visible-Light-Compatible, Polymer-Based Photonic Crystal Resonator and Waveguide for Sensing Applications
In this paper, we have proposed a polymer-based photonic crystal (PhC) resonator, with multiple sizes of cavities, and a waveguide to be used as highly sensitive optical sensor components. Properties of the proposed PhC were simulated by the finite-difference time-domain method, and the polymer-based PhC resonator and waveguide were fabricated on a photoresist (polymer) by electron beam lithography, which was prepared on an Au-layer-deposited Si substrate. We detected the resonant light that penetrated through the waveguide and was trapped in the PhC resonator. Optical characteristics of the fabricated PhC were evaluated by detecting the polymer layer deposition process by using the layer-by-layer (LbL) method to deposit polymer layers. As a result, by using an optimized design of a polymer-based PhC resonator with a long cavity (equivalent to a defect of three holes), the PhC structure changes caused by LbL deposition lead to changes in resonant light wavelength (peak shift: 5.26 nm/layer). Therefore, we suggest that a PhC resonator and a waveguide is applicable as an optical sensor.