Carlos Sánchez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Carlos Sánchez has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Esther Pueyo
Universidad de Zaragoza
9 shared publications - Pablo Laguna
University of Zaragoza
6 shared publications - Alfonso Bueno-Orovio
Department of Computer Science, University of Oxford, Oxford, United Kingdom
5 shared publications - Blanca Rodriguez
Department of Computer Science, British Heart Foundation Centre of Research Excellence, University of Oxford, Oxford, UK
5 shared publications - Mark Potse
Department of Biomedical Engineering, Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, The Netherlands
4 shared publications - Syed Hassaan Ahmed Bukhari
Department of Biomedical Engineering Cleveland Clinic Research Cleveland Ohio USA
4 shared publications
Latest Publications
- Open Access
Heart Rate Variability to Automatically Identify Hyperbaric States Considering Respiratory Component
This study’s primary objective was to identify individuals whose physiological responses deviated from the rest of the study population by automatically monitoring atmospheric pressure levels to which they are exposed and using parameters derived from their heart rate variability (HRV). To achieve this, 28 volunteers were placed in a dry hyperbaric chamber, where they experienced varying pressures from 1 to 5 atmospheres, with five sequential stops lasting five minutes each at different atmospheric pressures. The HRV was dissected into two components: the respiratory component, which is linked to respiration; and the residual component, which is influenced by factors beyond respiration. Nine parameters were assessed, including the respiratory rate, four classic HRV temporal parameters, and four frequency parameters. A k-nearest neighbors classifier based on cosine distance successfully identified the atmospheric pressures to which the subjects were exposed to. The classifier achieved an 88.5% accuracy rate in distinguishing between the 5 atm and 3 atm stages using only four features: respiratory rate, heart rate, and two frequency parameters associated with the subjects’ sympathetic responses. Furthermore, the study identified 6 out of 28 subjects as having atypical responses across all pressure levels when compared to the majority. Interestingly, two of these subjects stood out in terms of gender and having less prior diving experience, but they still exhibited normal responses to immersion. This suggests the potential for establishing distinct safety protocols for divers based on their previous experience and gender.
Open AccessHeart Rate Variability to Automatically Identify Hyperbaric States Considering Respiratory Component
This study’s primary objective was to identify individuals whose physiological responses deviated from the rest of the study population by automatically monitoring atmospheric pressure levels to which they are exposed and using parameters derived from their heart rate variability (HRV). To achieve this, 28 volunteers were placed in a dry hyperbaric chamber, where they experienced varying pressures from 1 to 5 atmospheres, with five sequential stops lasting five minutes each at different atmospheric pressures. The HRV was dissected into two components: the respiratory component, which is linked to respiration; and the residual component, which is influenced by factors beyond respiration. Nine parameters were assessed, including the respiratory rate, four classic HRV temporal parameters, and four frequency parameters. A k-nearest neighbors classifier based on cosine distance successfully identified the atmospheric pressures to which the subjects were exposed to. The classifier achieved an 88.5% accuracy rate in distinguishing between the 5 atm and 3 atm stages using only four features: respiratory rate, heart rate, and two frequency parameters associated with the subjects’ sympathetic responses. Furthermore, the study identified 6 out of 28 subjects as having atypical responses across all pressure levels when compared to the majority. Interestingly, two of these subjects stood out in terms of gender and having less prior diving experience, but they still exhibited normal responses to immersion. This suggests the potential for establishing distinct safety protocols for divers based on their previous experience and gender.
- Open Access
Enhancing Safety in Hyperbaric Environments through Analysis of Autonomic Nervous System Responses: A Comparison of Dry and Humid Conditions
Diving can have significant cardiovascular effects on the human body and increase the risk of developing cardiac health issues. This study aimed to investigate the autonomic nervous system (ANS) responses of healthy individuals during simulated dives in hyperbaric chambers and explore the effects of the humid environment on these responses. Electrocardiographic- and heart-rate-variability ()-derived indices were analyzed, and their statistical ranges were compared at different depths during simulated immersions under dry and humid conditions. The results showed that humidity significantly affected the ANS responses of the subjects, leading to reduced parasympathetic activity and increased sympathetic dominance. The power of the high-frequency band of the after removing the influence of respiration, , and the number of pairs of successive normal-to-normal intervals that differ by more than 50 ms divided by the total number of normal-to-normal intervals, , indices were found to be the most informative in distinguishing the ANS responses of subjects between the two datasets. Additionally, the statistical ranges of the indices were calculated, and the classification of subjects as “normal” or “abnormal” was determined based on these ranges. The results showed that the ranges were effective at identifying abnormal ANS responses, indicating the potential use of these ranges as a reference for monitoring the activity of divers and avoiding future immersions if many indices are out of the normal ranges. The bagging method was also used to include some variability in the datasets’ ranges, and the classification results showed that the ranges computed without proper bagging represent reality and its associated variability. Overall, this study provides valuable insights into the ANS responses of healthy individuals during simulated dives in hyperbaric chambers and the effects of humidity on these responses.Open AccessEnhancing Safety in Hyperbaric Environments through Analysis of Autonomic Nervous System Responses: A Comparison of Dry and Humid Conditions
Diving can have significant cardiovascular effects on the human body and increase the risk of developing cardiac health issues. This study aimed to investigate the autonomic nervous system (ANS) responses of healthy individuals during simulated dives in hyperbaric chambers and explore the effects of the humid environment on these responses. Electrocardiographic- and heart-rate-variability ()-derived indices were analyzed, and their statistical ranges were compared at different depths during simulated immersions under dry and humid conditions. The results showed that humidity significantly affected the ANS responses of the subjects, leading to reduced parasympathetic activity and increased sympathetic dominance. The power of the high-frequency band of the after removing the influence of respiration, , and the number of pairs of successive normal-to-normal intervals that differ by more than 50 ms divided by the total number of normal-to-normal intervals, , indices were found to be the most informative in distinguishing the ANS responses of subjects between the two datasets. Additionally, the statistical ranges of the indices were calculated, and the classification of subjects as “normal” or “abnormal” was determined based on these ranges. The results showed that the ranges were effective at identifying abnormal ANS responses, indicating the potential use of these ranges as a reference for monitoring the activity of divers and avoiding future immersions if many indices are out of the normal ranges. The bagging method was also used to include some variability in the datasets’ ranges, and the classification results showed that the ranges computed without proper bagging represent reality and its associated variability. Overall, this study provides valuable insights into the ANS responses of healthy individuals during simulated dives in hyperbaric chambers and the effects of humidity on these responses. - Open Access
- 5 March 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 157, 106719
Steady-state and transient effects of SK channel block and adrenergic stimulation to counteract acetylcholine-induced arrhythmogenic effects in the human atria: A computational study
- 5 March 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 157, 106719
Open AccessSteady-state and transient effects of SK channel block and adrenergic stimulation to counteract acetylcholine-induced arrhythmogenic effects in the human atria: A computational study
- Open Access
Monitoring of Serum Potassium and Calcium Levels in End-Stage Renal Disease Patients by ECG Depolarization Morphology Analysis
Objective: Non-invasive estimation of serum potassium, , and calcium, , can help to prevent life-threatening ventricular arrhythmias in patients with advanced renal disease, but current methods for estimation of electrolyte levels have limitations. We aimed to develop new markers based on the morphology of the QRS complex of the electrocardiogram (ECG). Methods: ECG recordings from 29 patients undergoing hemodialysis (HD) were processed. Mean warped QRS complexes were computed in two-minute windows at the start of an HD session, at the end of each HD hour and 48 h after it. We quantified QRS width, amplitude and the proposed QRS morphology-based markers that were computed by warping techniques. Reference and were determined from blood samples acquired at the time points where the markers were estimated. Linear regression models were used to estimate electrolyte levels from the QRS markers individually and in combination with T wave morphology markers. Leave-one-out cross-validation was used to assess the performance of the estimators. Results: All markers, except for QRS width, strongly correlated with (median Pearson correlation coefficients, r, ranging from 0.81 to 0.87) and with (r ranging from 0.61 to 0.76). QRS morphology markers showed very low sensitivity to heart rate (HR). Actual and estimated serum electrolyte levels differed, on average, by less than 0.035 mM (relative error of 0.018) for and 0.010 mM (relative error of 0.004) for when patient-specific multivariable estimators combining QRS and T wave markers were used. Conclusion: QRS morphological markers allow non-invasive estimation of and with low sensitivity to HR. The estimation performance is improved when multivariable models, including T wave markers, are considered. Significance: Markers based on the QRS complex of the ECG could contribute to non-invasive monitoring of serum electrolyte levels and arrhythmia risk prediction in patients with renal disease.Open AccessMonitoring of Serum Potassium and Calcium Levels in End-Stage Renal Disease Patients by ECG Depolarization Morphology Analysis
Objective: Non-invasive estimation of serum potassium, , and calcium, , can help to prevent life-threatening ventricular arrhythmias in patients with advanced renal disease, but current methods for estimation of electrolyte levels have limitations. We aimed to develop new markers based on the morphology of the QRS complex of the electrocardiogram (ECG). Methods: ECG recordings from 29 patients undergoing hemodialysis (HD) were processed. Mean warped QRS complexes were computed in two-minute windows at the start of an HD session, at the end of each HD hour and 48 h after it. We quantified QRS width, amplitude and the proposed QRS morphology-based markers that were computed by warping techniques. Reference and were determined from blood samples acquired at the time points where the markers were estimated. Linear regression models were used to estimate electrolyte levels from the QRS markers individually and in combination with T wave morphology markers. Leave-one-out cross-validation was used to assess the performance of the estimators. Results: All markers, except for QRS width, strongly correlated with (median Pearson correlation coefficients, r, ranging from 0.81 to 0.87) and with (r ranging from 0.61 to 0.76). QRS morphology markers showed very low sensitivity to heart rate (HR). Actual and estimated serum electrolyte levels differed, on average, by less than 0.035 mM (relative error of 0.018) for and 0.010 mM (relative error of 0.004) for when patient-specific multivariable estimators combining QRS and T wave markers were used. Conclusion: QRS morphological markers allow non-invasive estimation of and with low sensitivity to HR. The estimation performance is improved when multivariable models, including T wave markers, are considered. Significance: Markers based on the QRS complex of the ECG could contribute to non-invasive monitoring of serum electrolyte levels and arrhythmia risk prediction in patients with renal disease. - Open Access
- 4 April 2022
- Published by Zotarelli-Filho Scientific Works in MedNEXT Journal of Medical and Health Sciences
- Vol. 3 (2)
Optimization of the dental implant with the use of ILIB: major considerations
Introduction: In the context of implantology and osseointegration for the stabilization of dental implants, the use of ILIB (Intravascular Laser Irradiation of Blood) to stimulate tissues, cells, and molecules at the systemic level stands out. In this sense, ILIB can be used with postoperative applications in the osseointegration and stability of dental implants. Objective: Conducted a concise systematic review of the main findings of using the ILIB to improve dental implant practices. Methods: The research was carried out from May 2021 to June 2021 and developed based on Scopus, PubMed, Science Direct, Scielo, and Google Scholar, following the Systematic Review-PRISMA rules. The quality of the studies was based on the GRADE instrument and the risk of bias was analyzed according to the Cochrane instrument. Results: A total of 58 studies were analyzed, with only 10 medium and high-quality studies selected, according to GRADE rules, and with risks of bias that do not compromise scientific development. After analyzing the major studies, it was analyzed that, with the use of ILIB, several bone regeneration factors can be promoted and optimized for implant dentistry. Other authors have shown that ILIB therapy has oral sterilization properties, facilitating tissue healing after surgical procedures and the osseointegration process for placement of stable implants. Despite this, low-intensity laser irradiation may have limitations, as it requires specific dosimetry and few published studies on the use of ILIB in Dentistry. Conclusion: Literary findings point to the safety and efficacy of ILIB in dental implant treatments. The ILIB power is included as an eligibility criterion equal to other low power lasers. Furthermore, ILIB enables local and systemic treatment, optimizing the benefits of its use by dentists, mainly to improve the stabilization of osseointegrated implants and prevent or eliminate contamination.
- 4 April 2022
- Published by Zotarelli-Filho Scientific Works in MedNEXT Journal of Medical and Health Sciences
- Vol. 3 (2)
Open AccessOptimization of the dental implant with the use of ILIB: major considerations
Introduction: In the context of implantology and osseointegration for the stabilization of dental implants, the use of ILIB (Intravascular Laser Irradiation of Blood) to stimulate tissues, cells, and molecules at the systemic level stands out. In this sense, ILIB can be used with postoperative applications in the osseointegration and stability of dental implants. Objective: Conducted a concise systematic review of the main findings of using the ILIB to improve dental implant practices. Methods: The research was carried out from May 2021 to June 2021 and developed based on Scopus, PubMed, Science Direct, Scielo, and Google Scholar, following the Systematic Review-PRISMA rules. The quality of the studies was based on the GRADE instrument and the risk of bias was analyzed according to the Cochrane instrument. Results: A total of 58 studies were analyzed, with only 10 medium and high-quality studies selected, according to GRADE rules, and with risks of bias that do not compromise scientific development. After analyzing the major studies, it was analyzed that, with the use of ILIB, several bone regeneration factors can be promoted and optimized for implant dentistry. Other authors have shown that ILIB therapy has oral sterilization properties, facilitating tissue healing after surgical procedures and the osseointegration process for placement of stable implants. Despite this, low-intensity laser irradiation may have limitations, as it requires specific dosimetry and few published studies on the use of ILIB in Dentistry. Conclusion: Literary findings point to the safety and efficacy of ILIB in dental implant treatments. The ILIB power is included as an eligibility criterion equal to other low power lasers. Furthermore, ILIB enables local and systemic treatment, optimizing the benefits of its use by dentists, mainly to improve the stabilization of osseointegrated implants and prevent or eliminate contamination.
- Open Access
- 8 February 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 143, 105304
Estimation of potassium levels in hemodialysis patients by T wave nonlinear dynamics and morphology markers
- 8 February 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 143, 105304
Open AccessEstimation of potassium levels in hemodialysis patients by T wave nonlinear dynamics and morphology markers
- Open Access
- 11 August 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12
Location of Parasympathetic Innervation Regions From Electrograms to Guide Atrial Fibrillation Ablation Therapy: An in silico Modeling Study
The autonomic nervous system (ANS) plays an essential role in the generation and maintenance of cardiac arrhythmias. The cardiac ANS can be divided into its extrinsic and intrinsic components, with the latter being organized in an epicardial neural network of interconnecting axons and clusters of autonomic ganglia called ganglionated plexi (GPs). GP ablation has been associated with a decreased risk of AF recurrence, but accurate location of GPs is required for ablation to be effective. Although GP stimulation triggers both sympathetic and parasympathetic ANS branches, predominance of parasympathetic activity has been shown. The aim of this study was to develop a method to locate atrial parasympathetic innervation sites based on measurements from a grid of electrograms (EGMs). Electrophysiological models representative of non-AF, paroxysmal AF (PxAF) and persistent AF (PsAF) tissues were developed. Parasympathetic effects were modeled by increasing the concentration of the neurotransmitter acetylcholine (ACh) in randomly distributed circles across the tissue. Different ACh circle sizes and fibrosis geometries were considered, accounting for both uniform diffuse and non-uniform diffuse fibrosis. Computational simulations were performed, from which unipolar EGMs were computed in a 16$\times$16 electrode mesh. Different distances of the electrodes to the tissue (0.5, 1 and 2 mm) and noise levels with SNR values of 0, 5, 10, 15 and 20 dB were tested. The amplitude of the atrial EGM repolarization wave was found to be representative of the presence or absence of ACh release sites, with larger positive amplitudes indicating that the electrode was placed over an ACh region. Statistical analysis was performed to identify the optimal thresholds for identification of ACh sites. In all non-AF, PxAF and PsAF tissues, the repolarization amplitude rendered successful identification. The algorithm performed better in the absence of fibrosis or when fibrosis was uniformly diffuse, with a mean accuracy of 0.94 in contrast with a mean accuracy of 0.89 for non-uniform diffuse fibrotic cases. The algorithm was robust against noise, and worked for the tested ranges of electrode-to-tissue distance. In conclusion, the results from this study support the feasibility to locate atrial parasympathetic innervation sites from the amplitude of the EGMs' repolarization wave.
- 11 August 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12
Open AccessLocation of Parasympathetic Innervation Regions From Electrograms to Guide Atrial Fibrillation Ablation Therapy: An in silico Modeling Study
The autonomic nervous system (ANS) plays an essential role in the generation and maintenance of cardiac arrhythmias. The cardiac ANS can be divided into its extrinsic and intrinsic components, with the latter being organized in an epicardial neural network of interconnecting axons and clusters of autonomic ganglia called ganglionated plexi (GPs). GP ablation has been associated with a decreased risk of AF recurrence, but accurate location of GPs is required for ablation to be effective. Although GP stimulation triggers both sympathetic and parasympathetic ANS branches, predominance of parasympathetic activity has been shown. The aim of this study was to develop a method to locate atrial parasympathetic innervation sites based on measurements from a grid of electrograms (EGMs). Electrophysiological models representative of non-AF, paroxysmal AF (PxAF) and persistent AF (PsAF) tissues were developed. Parasympathetic effects were modeled by increasing the concentration of the neurotransmitter acetylcholine (ACh) in randomly distributed circles across the tissue. Different ACh circle sizes and fibrosis geometries were considered, accounting for both uniform diffuse and non-uniform diffuse fibrosis. Computational simulations were performed, from which unipolar EGMs were computed in a 16$\times$16 electrode mesh. Different distances of the electrodes to the tissue (0.5, 1 and 2 mm) and noise levels with SNR values of 0, 5, 10, 15 and 20 dB were tested. The amplitude of the atrial EGM repolarization wave was found to be representative of the presence or absence of ACh release sites, with larger positive amplitudes indicating that the electrode was placed over an ACh region. Statistical analysis was performed to identify the optimal thresholds for identification of ACh sites. In all non-AF, PxAF and PsAF tissues, the repolarization amplitude rendered successful identification. The algorithm performed better in the absence of fibrosis or when fibrosis was uniformly diffuse, with a mean accuracy of 0.94 in contrast with a mean accuracy of 0.89 for non-uniform diffuse fibrotic cases. The algorithm was robust against noise, and worked for the tested ranges of electrode-to-tissue distance. In conclusion, the results from this study support the feasibility to locate atrial parasympathetic innervation sites from the amplitude of the EGMs' repolarization wave.
- 1 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (5) , 1550-1560
Photoplethysmographic Waveform and Pulse Rate Variability Analysis in Hyperbaric Environments
The main aim of this work is to identify alterations in the morphology of the pulse photoplethysmogram (PPG) signal, due to the exposure of the subjects to a hyperbaric environment. Additionally, their Pulse Rate Variability (PRV) is analysed to characterise the response of their Autonomic Nervous System (ANS). To do that, 28 volunteers are introduced into a hyperbaric chamber and five sequential stages with different atmospheric pressures from 1 atm to 5 atm are performed. In this work, nineteen morphological parameters of the PPG signal are analysed: the pulse amplitude; eight parameters related to pulse width; eight parameters related to pulse area; and the two two pulse slopes. Also, classical time and frequency parameters of PRV are computed. Notable widening of the pulses width is observed in the stages analysed. The PPG area increases with pressure, with no significant changes when the initial pressure is recovered. These changes in PPG waveform may be caused by an increase in the systemic vascular resistance as a consequence of of vasoconstriction in the extremities, suggesting a sympathetic activation. However, the PRV results show an augmented parasympathetic activity and a reduction in the parameters that characterise the sympathetic response. So, only a sympathetic activation is detected in the peripheral region, as reflected by PPG morphology. The information regarding the ANS and the cardiovascular response that can be extracted from the PPG signal, as well as its compatibility with wet conditions make this signal the most suitable for studying the physiological response in hyperbaric environments.
- 1 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (5) , 1550-1560
Photoplethysmographic Waveform and Pulse Rate Variability Analysis in Hyperbaric Environments
The main aim of this work is to identify alterations in the morphology of the pulse photoplethysmogram (PPG) signal, due to the exposure of the subjects to a hyperbaric environment. Additionally, their Pulse Rate Variability (PRV) is analysed to characterise the response of their Autonomic Nervous System (ANS). To do that, 28 volunteers are introduced into a hyperbaric chamber and five sequential stages with different atmospheric pressures from 1 atm to 5 atm are performed. In this work, nineteen morphological parameters of the PPG signal are analysed: the pulse amplitude; eight parameters related to pulse width; eight parameters related to pulse area; and the two two pulse slopes. Also, classical time and frequency parameters of PRV are computed. Notable widening of the pulses width is observed in the stages analysed. The PPG area increases with pressure, with no significant changes when the initial pressure is recovered. These changes in PPG waveform may be caused by an increase in the systemic vascular resistance as a consequence of of vasoconstriction in the extremities, suggesting a sympathetic activation. However, the PRV results show an augmented parasympathetic activity and a reduction in the parameters that characterise the sympathetic response. So, only a sympathetic activation is detected in the peripheral region, as reflected by PPG morphology. The information regarding the ANS and the cardiovascular response that can be extracted from the PPG signal, as well as its compatibility with wet conditions make this signal the most suitable for studying the physiological response in hyperbaric environments.
- Open Access
- 30 December 2020
- Published by Computing in Cardiology
Analysis of T Wave Nonlinear Dynamics for Serum Potassium Monitoring in End-Stage Renal Disease Patients
- 30 December 2020
- Published by Computing in Cardiology
Open AccessAnalysis of T Wave Nonlinear Dynamics for Serum Potassium Monitoring in End-Stage Renal Disease Patients
- Open Access
- 10 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (8) , 2467-2478
Characterization of T Wave Amplitude, Duration and Morphology Changes During Hemodialysis: Relationship With Serum Electrolyte Levels and Heart Rate
Objective: Chronic kidney disease affects more than 10% of the world population. Changes in serum ion concentrations increase the risk for ventricular arrhythmias and sudden cardiac death, particularly in end-stage renal disease (ESRD) patients. We characterized how T wave amplitude, duration and morphology descriptors change with variations in serum levels of potassium and calcium and in heart rate, both in ESRD patients and in simulated ventricular fibers. Methods: Electrocardiogram (ECG) recordings from twenty ESRD patients undergoing hemodialysis (HD) and pseudo-ECGs (pECGs) calculated from twenty-two simulated ventricular fibers at varying transmural heterogeneity levels were processed to quantify T wave width ( ${\rm T_{w}}$ ), T wave slope-to-amplitude ratio ( ${\rm T_{S/A}}$ ) and four indices of T wave morphological variability based on time warping ( ${\rm d_{w}, d_{w}^{NL},d_{a}\ and\ d_{a}^{NL}}$ ). Serum potassium and calcium levels and heart rate were measured along HD. Results: ${\rm d_{w}^{NL}}$ was the marker most strongly correlated with serum potassium, ${\rm d_{w}}$ with calcium and ${\rm d_{a}}$ with heart rate, after correction for covariates. Median values of partial correlation coefficients were 0.75, -0.74 and -0.90, respectively. For all analyzed T wave descriptors, high inter-patient variability was observed in the pattern of such relationships. This variability, accentuated during the first HD time points, was reproduced in the simulations and shown to be influenced by differences in transmural heterogeneity. Conclusion: Changes in serum potassium and calcium levels and in heart rate have markable effects on T wave descriptors, particularly those quantifying morphological variability. Significance: ECG markers have the potential to be used for monitoring serum ion concentrations in ESRD patients.- 10 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (8) , 2467-2478
Open AccessCharacterization of T Wave Amplitude, Duration and Morphology Changes During Hemodialysis: Relationship With Serum Electrolyte Levels and Heart Rate
Objective: Chronic kidney disease affects more than 10% of the world population. Changes in serum ion concentrations increase the risk for ventricular arrhythmias and sudden cardiac death, particularly in end-stage renal disease (ESRD) patients. We characterized how T wave amplitude, duration and morphology descriptors change with variations in serum levels of potassium and calcium and in heart rate, both in ESRD patients and in simulated ventricular fibers. Methods: Electrocardiogram (ECG) recordings from twenty ESRD patients undergoing hemodialysis (HD) and pseudo-ECGs (pECGs) calculated from twenty-two simulated ventricular fibers at varying transmural heterogeneity levels were processed to quantify T wave width ( ${\rm T_{w}}$ ), T wave slope-to-amplitude ratio ( ${\rm T_{S/A}}$ ) and four indices of T wave morphological variability based on time warping ( ${\rm d_{w}, d_{w}^{NL},d_{a}\ and\ d_{a}^{NL}}$ ). Serum potassium and calcium levels and heart rate were measured along HD. Results: ${\rm d_{w}^{NL}}$ was the marker most strongly correlated with serum potassium, ${\rm d_{w}}$ with calcium and ${\rm d_{a}}$ with heart rate, after correction for covariates. Median values of partial correlation coefficients were 0.75, -0.74 and -0.90, respectively. For all analyzed T wave descriptors, high inter-patient variability was observed in the pattern of such relationships. This variability, accentuated during the first HD time points, was reproduced in the simulations and shown to be influenced by differences in transmural heterogeneity. Conclusion: Changes in serum potassium and calcium levels and in heart rate have markable effects on T wave descriptors, particularly those quantifying morphological variability. Significance: ECG markers have the potential to be used for monitoring serum ion concentrations in ESRD patients.