TATricia Adjei

Tricia Adjei

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tricia Adjei has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Danilo P. Mandic

    Department of Electrical and Electronic Engineering, Imperial College London, London, UK

    4 shared publications
  • Danilo P. Mandic

    Communications and Signal Processing, Department of Electrical and Electronic Engineering, Imperial College London, London, United Kingdom

    2 shared publications
  • Jingwen Xue

    Communications and Signal Processing, Department of Electrical and Electronic Engineering, Imperial College London, London, United Kingdom

    2 shared publications
  • Allan J. Pettipher

    Department of Electrical and Electronic Engineering, Imperial College London, London SW7 2AZ, UK

    1 shared publication
  • Apit Hemakom

    Biomedical Electronics and Systems Research Team, National Electronics and Computer Technology Center, National Science and Technology Development Agency, 111 Thailand Science Park, Phahonyothin Road, Klong 1, Klong Luang, Pathumthani 12120, Thailand

    1 shared publication
  • Daniel Abásolo

    Centre for Biomedical Engineering, School of Engineering, University of Surrey, Guildford GU2 7XH, UK

    1 shared publication

Latest Publications

  • Open Access

    A Pilot Study of Heart Rate Variability Synchrony as a Marker of Intraoperative Surgical Teamwork and Its Correlation to the Length of Procedure

    by Katarzyna Powezka, Allan Pettipher, Apit Hemakom, Tricia Adjei, Pasha Normahani, Danilo P. Mandic, Usman Jaffer

    Objective: Quality of intraoperative teamwork may have a direct impact on patient outcomes. Heart rate variability (HRV) synchrony may be useful for objective assessment of team cohesion and good teamwork. The primary aim of this study was to investigate the feasibility of using HRV synchrony in surgical teams. Secondary aims were to investigate the association of HRV synchrony with length of procedure (LOP), complications, number of intraoperative glitches and length of stay (LOS). We also investigated the correlation between HRV synchrony and team familiarity, pre- and intraoperative stress levels (STAI questionnaire), NOTECHS score and experience of team members. Methods: Ear, nose and throat (ENT) and vascular surgeons (consultant and registrar team members) were recruited into the study. Baseline demographics including level of team members’ experience were gathered before each procedure. For each procedure, continuous electrocardiogram (ECG) recording was performed and questionnaires regarding pre- and intraoperative stress levels and non-technical skills (NOTECHS) scores were collected for each team member. An independent observer documented the time of each intraoperative glitch. Statistical analysis was conducted using stepwise multiple linear regression. Results: Four HRV synchrony metrics which may be markers of efficient surgical collaboration were identified from the data: 1. number of HRV synchronies per hour of procedure, 2. number of HRV synchrony trends per hour of procedure, 3. length of HRV synchrony trends per hour of procedure, 4. area under the HRV synchrony trend curve per hour of procedure. LOP was inversely correlated with number of HRV synchrony trends per hour of procedure (p < 0.0001), area under HRV synchrony trend curve per hour of procedure (p = 0.001), length of HRV synchrony trends per hour of procedure (p = 0.002) and number of HRV synchronies per hour of procedure (p < 0.0001). LOP was positively correlated with: FS (p = 0.043; R = 0.358) and intraoperative STAI score of the whole team (p = 0.007; R = 0.493). Conclusions: HRV synchrony metrics within operating teams may be used as an objective marker to quantify surgical teamwork. We have shown that LOP is shorter when the intraoperative surgical teams’ HRV is more synchronised.


  • Open Access

    The Female Heart: Sex Differences in the Dynamics of ECG in Response to Stress

    by Tricia Adjei, Jingwen Xue, Danilo P. Mandic

    Sex differences in the study of the human physiological response to mental stress are often erroneously ignored. To this end, we set out to show that our understanding of the stress response is fundamentally altered once sex differences are taken into account. This is achieved by comparing the heart rate variability (HRV) signals acquired during mental maths tests from ten females and ten males of similar maths ability; all females were in the follicular phase of their menstrual cycle. For rigor, the HRV signals from this pilot study were analyzed using temporal, spectral and nonlinear signal processing techniques, which all revealed significant statistical differences between the sexes, with the stress-induced increases in the heart rates from the males being significantly larger than those from the females (p-value = 4.4 × 10−4). In addition, mental stress produced an overall increase in the power of the low frequency component of HRV in the males, but caused an overall decrease in the females. The stress-induced changes in the power of the high frequency component were even more profound; it greatly decreased in the males, but increased in the females. We also show that mental stress was followed by the expected decrease in sample entropy, a nonlinear measure of signal regularity, computed from the males' HRV signals, while overall, stress manifested in an increase in the sample entropy computed from the females' HRV signals. This finding is significant, since mental stress is commonly understood to be manifested in the decreased entropy of HRV signals. The significant difference (p-value = 2.1 × 10−9) between the changes in the entropies from the males and females highlights the pitfalls in ignoring sex in the formation of a physiological hypothesis. Furthermore, it has been argued that estrogen attenuates the effect of catecholamine stress hormones; the findings from this investigation suggest for the first time that the conventionally cited cardiac changes, attributed to the fight-or-flight stress response, are not universally applicable to females. Instead, this pilot study provides an alternative interpretation of cardiac responses to stress in females, which indicates a closer alignment to the evolutionary tend-and-befriend response.


  • Open Access

    The Female Heart: Sex Differences in the Dynamics of ECG in Response to Stress

    by Tricia Adjei, Jingwen Xue, Danilo P. Mandic

    Sex differences in the study of the human physiological response to mental stress are often erroneously ignored. To this end, we set out to show that our understanding of the stress response is fundamentally altered once sex differences are taken into account. This is achieved by comparing the heart rate variability (HRV) signals acquired during mental maths tests from ten females and ten males of similar maths ability; all females were in the follicular phase of their menstrual cycle. For rigour, the HRV signals from this pilot study were analysed using temporal, spectral and nonlinear signal processing techniques, which all revealed significant statistical differences between the sexes, with the stress-induced increases in the heart rates from the males being significantly larger than those from the females (p-value=2.2×10 −3 ). In addition, mental stress produced an overall increase in the power of the low frequency component of HRV in the males, but caused an overall decrease in the females. The stress-induced changes in the power of the high frequency component were even more profound; it greatly decreased in the males, but increased in the females. We also show that mental stress was followed by the expected decrease in sample entropy, a nonlinear measure of signal regularity, computed from the males’ HRV signals, while overall, stress manifested in an increase in the sample entropy computed from the females’ HRV signals. This finding is significant, since mental stress is commonly understood to be manifested in the decreased entropy of HRV signals, however, the significant difference (p-value=2×10 −9 ) in the changes in the entropies from the males and females highlights the pitfalls in ignoring sex in the formation of a physiological hypothesis. Furthermore, it has been argued that oestrogen attenuates the effect of catecholamine stress hormones; the findings from this investigation suggest for the first time that the conventionally cited cardiac changes, attributed to the fight-or-flight stress response, are not universally applicable to females. Instead, this pilot study provides an alternative interpretation of cardiac responses to stress in females, which indicates a closer alignment to the evolutionary tend-and-befriend response.

  • Open Access

    A Novel Multivariate Sample Entropy Algorithm for Modeling Time Series Synchronization

    by David Looney, Tricia Adjei, Danilo P. Mandic

    Approximate and sample entropy (AE and SE) provide robust measures of the deterministic or stochastic content of a time series (regularity), as well as the degree of structural richness (complexity), through operations at multiple data scales. Despite the success of the univariate algorithms, multivariate sample entropy (mSE) algorithms are still in their infancy and have considerable shortcomings. Not only are existing mSE algorithms unable to analyse within- and cross-channel dynamics, they can counter-intuitively interpret increased correlation between variates as decreased regularity. To this end, we first revisit the embedding of multivariate delay vectors (DVs), critical to ensuring physically meaningful and accurate analysis. We next propose a novel mSE algorithm and demonstrate its improved performance over existing work, for synthetic data and for classifying wake and sleep states from real-world physiological data. It is furthermore revealed that, unlike other tools, such as the correlation of phase synchrony, synchronized regularity dynamics are uniquely identified via mSE analysis. In addition, a model for the operation of this novel algorithm in the presence of white Gaussian noise is presented, which, in contrast to the existing algorithms, reveals for the first time that increasing correlation between different variates reduces entropy.


  • Open Access

    Pain Prediction From ECG in Vascular Surgery

    by Tricia Adjei, Wilhelm Von Rosenberg, Valentin Goverdovsky, Katarzyna Powezka, Usman Jaffer, Danilo P. Mandic

    Varicose vein surgeries are routine outpatient procedures, which are often performed under local anaesthesia. The use of local anaesthesia both minimises the risk to patients and is cost effective, however, a number of patients still experience pain during surgery. Surgical teams must therefore decide to administer either a general or local anaesthetic based on their subjective qualitative assessment of patient anxiety and sensitivity to pain, without any means to objectively validate their decision. To this end, we develop a 3-D polynomial surface fit, of physiological metrics and numerical pain ratings from patients, in order to model the link between the modulation of cardiovascular responses and pain in varicose vein surgeries. Spectral and structural complexity features found in heart rate variability signals, recorded immediately prior to 17 varicose vein surgeries, are used as pain metrics. The so obtained pain prediction model is validated through a leave-one-out validation, and achieved a Kappa coefficient of 0.72 (substantial agreement) and an area below a receiver operating characteristic curve of 0.97 (almost perfect accuracy). This proof-of-concept study conclusively demonstrates the feasibility of the accurate classification of pain sensitivity, and introduces a mathematical model to aid clinicians in the objective administration of the safest and most cost-effective anaesthetic to individual patients.


  • Open Access

    Complexity science for sleep stage classification from EEG

    by Takashi Nakamura, Tricia Adjei, Yousef Alqurashi, David Looney, Mary J. Morrell, Danilo P. Mandic

    Automatic sleep stage classification is an important paradigm in computational intelligence and promises considerable advantages to the health care. Most current automated methods require the multiple electroencephalogram (EEG) channels and typically cannot distinguish the S1 sleep stage from EEG. The aim of this study is to revisit automatic sleep stage classification from EEGs using complexity science methods. The proposed method applies fuzzy entropy and permutation entropy as kernels of multi-scale entropy analysis. To account for sleep transition, the preceding and following 30 seconds of epoch data were used for analysis as well as the current epoch. Combining the entropy and spectral edge frequency features extracted from one EEG channel, a multi-class support vector machine (SVM) was able to classify 93.8% of 5 sleep stages for the SleepEDF database [expanded], with the sensitivity of S1 stage was 49.1%. Also, the Kappa's coefficient yielded 0.90, which indicates almost perfect agreement.


  • Open Access

    Characterisation of the complexity of intracranial pressure signals measured from idiopathic and secondary normal pressure hydrocephalus patients

    by Tricia Adjei, Daniel Abásolo, David Santamarta

    Hydrocephalus is a condition characterised by enlarged cerebral ventricles, which in turn affects intracranial pressure (ICP); however, the mechanisms regulating ICP are not fully understood. A nonlinear signal processing approach was applied to ICP signals measured during infusion studies from patients with two forms of hydrocephalus, in a bid to compare the differences. This is the first study of its kind. The two forms of hydrocephalus were idiopathic normal pressure hydrocephalus (iNPH) and secondary normal pressure hydrocephalus (SH). Following infusion tests, the Lempel–Ziv (LZ) complexity was calculated from the iNPH and SH ICP signals. The LZ complexity values were averaged for the baseline, infusion, plateau and recovery stages of the tests. It was found that as the ICP increased from basal levels, the LZ complexities decreased, reaching their lowest during the plateau stage. However, the complexities computed from the SH ICP signals decreased to a lesser extent when compared with the iNPH ICP signals. Furthermore, statistically significant differences were found between the plateau and recovery stage complexities when comparing the iNPH and SH results ( p = 0.05). This Letter suggests that advanced signal processing of ICP signals with LZ complexity can help characterise different types of hydrocephalus in more detail.