RYR. F. Yunusov

R. F. Yunusov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


R. F. Yunusov has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Impact of Glow Discharge Energy Characteristics on Gas Temperature

    by R. F. Yunusov, Z. D. Zakirov, E. R. Yunusova

    The paper examines experimentally the dependence of gas temperature in a glow discharge on gas-dynamic flow parameters and discharge energy parameters. The gas pressure P and its flow rate G in the discharge chamber varied from 2.5 to 5.5 kPa and from 0 to 0.035 g/s, respectively. The discharge current strength I and the power input N to the discharge also ranged from 30 to 80 mA and from 30 to 80 W. The gas temperature was measured by the thermocouple method at six points of the discharge gap, which also made it possible to estimate the change in gas temperature along the axis of the cylindrical channel and along its radius. At low gas consumption, the discharge was found to be axisymmetric and fill the entire volume of the discharge gap. As the current and discharge power increased, the gas temperature increased approximately linearly with an average rate of 5 K/W. With increasing air flow rate G from 0.017 to 0.035 g/s, the discharge rearranged from a bulk shape to a cord shape, and the temperature field of the discharge changed significantly: in the center of the discharge, the temperature decreased sharply and practically did not change with increasing discharge power, while near the discharge localization, the gas temperature increased linearly with increasing power at an average rate of 3 K/W.

  • Open Access

    Investigation of the electric field of the plasma ball

    by R F Yunusov, E R Yunusova

    Currently produced plasma balls have various design features and purposes. At the same time, the principle of operation of the plasma ball (PB) is described only in general terms and is of both scientific and practical interest. For the possibility of using PB in various technological areas [1-6], including in medicine, it is necessary to investigate the electric field created by this device. In this work, experiments were conducted on the study of the electric field PB: the interaction of PB with the conductor, gas-discharge light sources, and the propagation of the electromagnetic field PB over a distance. The values of the electric field strength outside PB and its dependence on distance were obtained experimentally.


  • Open Access

    Experimental study of transient processes in a Glow Discharge

    by R F Yunusov, M M Garipov

    The article experimentally investigated the features of a glow discharge with a hollow cathode in a longitudinal air flow. The discharge chamber consisted of glass sections separated by copper plates serving as probes. The channel formed by such sections and probes had a cylindrical shape. Air flowed through the hollow cathode into the cylindrical channel. The anode served as a metal grid. Probes and electrodes were made of copper. The distance between the electrodes was 6.5 cm. The air pressure P, its speed V, the discharge current I and its voltage U changed respectively in the ranges: P = (6, 4 - 19) kPa, V = (0 - 10) m / c, I = (5-100) mA, U = (1, 0 - 2, 2, 0) kV. Volt-ampere characteristic had negative differential resistance. It was found that in the range of discharge currents I = (40-80) mA, the forward and reverse branches of the current-voltage characteristics do not match. When the current decreases (reverse branch), the discharge voltage rises sharply. This is due to the process of transition of a glow discharge into its non-stationary form, which was observed visually and was recorded photographically for all the characteristic modes of discharge. It was also shown that the flow of air allows a reverse transition to the usual form of discharge.

  • Open Access

    Effect of gas flow on the form and characteristics of Glow Discharge

    by R F Yunusov, M M Garipov

    The article is devoted to an experimental study of the effect of gas flow on the characteristics of a glow discharge. The design of the discharge chamber made it possible to change the interelectrode distance a = (2–8) cm. The family of current-voltage characteristics was measured in the following ranges of gas pressure P, its flow rate G, discharge current I and voltage U: P = (4. 7 - 26) kPa, G = (0 – 0.05) g / s, I = (20 - 100) mA, U = (1. 5 – 4. 2) kV. The oscillations of the discharge voltage were recorded with an oscilloscope, the current-voltage characteristic of the discharge was recorded by a two-coordinate recorder. The current-voltage characteristics had a negative differential resistance. The influence of the interelectrode distance on the type and quantitative relationships of these characteristics is analyzed. When gas is pumped through the discharge chamber, the current-voltage characteristics do not change qualitatively, but the discharge voltage and the steepness of the characteristics increase compared to a discharge without gas flow. At pressures of the order of P = 26 kPa, the discharge stability deteriorates, and high-frequency oscillations of the discharge voltage are observed in the gas flow (f ~ 100 kHz). In this case, the discharge voltage decreases by a value of the order of tens of volts, and the glow of the positive column of discharge becomes intermittent. The typical oscillograms of discharge voltage pulsations are given.

  • Open Access

    Experimental study of the energy characteristics of a longitudinal Glow Discharge

    by R F Yunusov, M M Garipov

    Currently, a glow discharge is widely used not only as a gas-discharge light source or as an active medium for gas lasers, but also as an element of a plasma-chemical reactor, which allows for various chemical transformations in order to obtain new materials, modify and clean surfaces. Despite the fact that the structure and distribution of parameters in a classical glow discharge without gas flow and flat cylindrical electrodes are well known, to solve new technological problems, it is necessary to study glow discharge in discharge chambers with different electrode geometries and gas flow organization methods.The presence of a gas flow causes heterogeneity in the distribution of the parameters of a glow discharge, and can also affect the structure of its individual zones. Experimental study of the parameters of a longitudinal glow discharge will allow not only a better understanding of the physics of gas discharge, but also will make it possible to find ways to control these parameters, which is important for designing discharge chambers of various technological purposes. The article is devoted to a comprehensive experimental study of the distribution of potentials, field strength, current-voltage characteristics in a longitudinal glow discharge. The gas pressure P, its flow rate G, the discharge current strength I and its voltage U vary respectively in the ranges: P = (2–9) kPa, G = (0–0. 05) g / s, I = (30-80) mA, U = (1 - 2) kV.


  • Open Access

    Heat Balance in the Positive Column of a Glow Discharge

    by R F Yunusov, M M Garipov, E R Yunusova

    According to classical concepts, a cylindrical positive column (PC) of the glow discharge (GD) is a luminous volume of ionized gas that fills up the whole space in the discharge chamber (DC) and which parameters are indiscrete, i.e. they do not vary along the axis of the chamber. In this case, the heat balance of the PC is that the electric power released in the discharge is expended on the heat flux to the wall of the discharge chamber (DC) due to heat transfer; also, a certain fraction of energy is carried away due to heat transfer by radiation. In case of an open system when gas flows through the area of the PC, it is possible to change the discharge parameters along its axis, and it is necessary to take into account heat transfer by convection in the energy balance. It is important to have knowledge of heat balance and its components both for gas discharge physics and for any DC designed for various applications. This paper is devoted to a comprehensive experimental study of the distribution of potential, electric field intensity, and gas temperature in the longitudinal GD. The gas pressure P, its flow rate G, the discharge current I and its voltage U varied accordingly in the following ranges: P = (2 – 9) kPa, G = (0 – 0.05) g/s, I = (30 – 80) mA, U= (1 – 2) kV. The obtained distribution of potential, electric field intensity, and gas temperature make it possible to calculate all the heat fluxes in the plasma of the discharge PC.


  • Open Access

    Transients in a longitudinal Glow Discharge

    by R F Yunusov, M M Garipov, E R Yunusova

    The article is devoted to an experimental study of transient processes in a glow discharge (GD). The longitudinal GD was ignited in a stream of air in a cylindrical discharge chamber (DC). Copper hollow electrodes were located at a distance of a = (2 ? 8) cm from each other along the axis of the DC. The gas pressure P, its flow rate G, discharge current I and its voltage U varied accordingly in the ranges: P = (4.7 ? 26) kPa, G = (0 ? 0.05) g / s, I = (20 ?100) mA, U = (1. 5 ? 4. 2) kV. The current-voltage characteristics of the discharge were measured. The voltage decreased with increasing current, which is typical for a given type of discharge. The oscillations of the discharge voltage were registered by an oscilloscope; the current-voltage characteristic of the discharge was recorded by a two-coordinate recorder. Low-frequency (f ~ 300 Hz) and high-frequency (f ~ 100 kHz) oscillations of the discharge voltage were observed. The influence of the gas flow on the current-voltage characteristics of the discharge, its shape and the frequency of the detected oscillations is shown.


  • Open Access

    Experimental study of heat transfer in a glow discharge

    by R F Yunusov, M M Garipov

    The article is devoted to the experimental study of heat transfer in a glow discharge. The longitudinal discharge was ignited in a stream of air moving in a cylindrical discharge chamber (DC). Copper electrodes were located at a distance of 9 cm from each other perpendicular to the axis of the DC. The gas pressure P = (2 - 9) kPa and its flow rate G = (0 - 0.035) g / s were monitored. The discharge current and voltage varied accordingly in the ranges: I = (30-80) mA, U = (1-2) kV. Falling current-voltage characteristics were observed. The temperature of the neutral particles was measured using chromel-alumel thermocouples located along the DC in three sections. The location of the thermocouples made it possible to measure the temperature distribution both along the DC and across it. The discharge shape was monitored photographically and visually. It was found that with an air flow rate G = 0.017 g / s, the discharge loses its axial symmetry and contracts to the wall of the DC. The temperature field of neutral particles also changes significantly.


  • Open Access

    Experimental study of voltage fluctuations in a glow discharge

    by R F Yunusov, M M Garipov

    The article is devoted to the experimental study of voltage pulsations in a glow discharge. The longitudinal discharge was ignited in a stream of air moving in a cylindrical discharge chamber (DC). Copper hollow electrodes were located at a distance of a = (2-8) cm from each other along the axis of the DC. The gas pressure P = (4.7 - 26) kPa and its flow rate G = (0-0.06) g/s were monitored. The discharge current and voltage varied accordingly in the ranges: I = (20-100) mA, U = (1, 5 - 4, 2) kV. The current-voltage characteristics of the discharge were measured. The voltage decreased with increasing current, which is typical for a given type of discharge. The oscillations of the discharge voltage were registered by an oscilloscope; the current-voltage characteristic of the discharge was recorded by a two-coordinate recorder. Three regions of the current-voltage characteristic were detected. The luminous positive discharge column (PC) occupied the entire interelectrode space in the current region I = (100-70) mA. In the current range I = (70-40) mA there is a smooth transition to the discharge without visible glow of the PC with a significant increase in the discharge voltage. With further reduction of the current intensity (the third region), the discharge exists almost at a constant voltage until its quenching. Low-frequency and high-frequency oscillations of the discharge voltage were observed at the boundary of the second and third regions of the current-voltage characteristic.


  • Open Access

    Heat transfer in a longitudinal glow discharge

    by R F Yunusov

    This article is devoted to the experimental study of heat transfer in a longitudinal glow discharge. The discharge was ignited in the discharge chamber (DC), consisting of a glass tube 10 mm in diameter and two electrodes. Copper electrodes were placed in the side branches, so that the average distance between them was 9 cm. The discharge pressure was varied in the range of P = (2.5 – 8.5) kPa. The air flow rate was varied from zero to G = 0.06 g / s. Current was varied in the range of I = (30-80) mA. Current-voltage characteristics of the discharge had falling form, and the voltage was varied in the range of U = (1-2) kV. The temperature of neutral particles in the plasma glow discharge was measured by six thermocouples, which were insertedon radius of DC. The aim of the article was to compare achieved experiment data with theoretical studies: recombination and diffusion plasma models.