Bolatbek Utegulov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bolatbek Utegulov has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Aigul Uakhitova
Department of Electric Power Supply, Seifullin Kazakh Agrotechnical Research University, Astana, Kazakhstan
7 shared publications - Arman Utegulov
S. Seifullin Kazakh Agrotechnical research University
7 shared publications Meiram Begentayev
7 shared publicationsNazhmitden Zhakipov
7 shared publicationsBagustar Begentayev
4 shared publications- Serik Zhumazhanov
L.N. Gumilyov Eurasian National University, Kazakhstan
3 shared publications
Latest Publications
- Open Access
- 1 November 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 643 (1) , 012062
The influence of some natural factors on efficiency of operation of photoelectric elements under conditions of North Kazakhstan
The article presents the results of studies of some natural factors on the productivity of solar cells. In the study of output characteristics, the dependence of the generation of electrical energy on the number of incident solar radiation on photoelectric converters was obtained. From these characteristics it can be precisely said that the dependence of the operating current and voltage on solar radiation and temperature is not completely proportional. The humidity exerts the most insignificant influence on the solar installation. Particular attention should be paid to the dependence of voltage changes on the magnitude of solar radiation. It has been revealed that in low power plants the influence of temperature will not play an extremely important role on the output parameters, but at higher powers the losses associated with the increase in temperature will be correspondingly large. The generation of electrical energy from solar photoelectric converters depends on many factors, not only on incoming radiation, but also on aspects such as: the location of the solar transducer to the sun, pollution of solar cells, icing and snow cover of solar cells. In this scientific work was made an analysis of the effect of snow precipitation on the productivity of solar cells in the characteristic climatic conditions of North Kazakhstan.
- 1 November 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 643 (1) , 012062
Open AccessThe influence of some natural factors on efficiency of operation of photoelectric elements under conditions of North Kazakhstan
The article presents the results of studies of some natural factors on the productivity of solar cells. In the study of output characteristics, the dependence of the generation of electrical energy on the number of incident solar radiation on photoelectric converters was obtained. From these characteristics it can be precisely said that the dependence of the operating current and voltage on solar radiation and temperature is not completely proportional. The humidity exerts the most insignificant influence on the solar installation. Particular attention should be paid to the dependence of voltage changes on the magnitude of solar radiation. It has been revealed that in low power plants the influence of temperature will not play an extremely important role on the output parameters, but at higher powers the losses associated with the increase in temperature will be correspondingly large. The generation of electrical energy from solar photoelectric converters depends on many factors, not only on incoming radiation, but also on aspects such as: the location of the solar transducer to the sun, pollution of solar cells, icing and snow cover of solar cells. In this scientific work was made an analysis of the effect of snow precipitation on the productivity of solar cells in the characteristic climatic conditions of North Kazakhstan.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 01-04
The Method for Determining the Insulation Parameters in an Asymmetric Network With a Voltage of Up to 1000 V
In this paper a method for determining insulation parameters in an asymmetric network with a voltage of up to 1000 V for mining companies was developed. It is based on measuring the magnitude of the linear voltage, the phase-to-ground voltage, which has a minimum value before and after connecting capacitive additional conductivity between the phases of electrical network and the ground, and the phase angle between the phase-to-ground voltage vector and the linear voltage vector between other two phases.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 01-04
The Method for Determining the Insulation Parameters in an Asymmetric Network With a Voltage of Up to 1000 V
In this paper a method for determining insulation parameters in an asymmetric network with a voltage of up to 1000 V for mining companies was developed. It is based on measuring the magnitude of the linear voltage, the phase-to-ground voltage, which has a minimum value before and after connecting capacitive additional conductivity between the phases of electrical network and the ground, and the phase angle between the phase-to-ground voltage vector and the linear voltage vector between other two phases.
- Open Access
- 1 August 2016
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 40 (1) , 012024
The method of determining the insulation parameters in three-phase electrical networks with isolated neutral with voltages up to and above 1000 V
In work the new method of definition of isolation's parameters in a three-phase symmetric electrical network with isolated neutral which is based on measurement of modules sizes of a linear voltage, voltages of phases C and A concerning to ground, after connection of active additional conductivity between phase A of electrical network and ground is shown and the analysis of a blunder of the developed method is made. The analysis of a blunder has shown, that the developed method provides satisfactory accuracy at definition of isolation's parameters, and also simplicity and the safety of operations in working electro installations of up to above 1000 V voltage.
- 1 August 2016
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 40 (1) , 012024
Open AccessThe method of determining the insulation parameters in three-phase electrical networks with isolated neutral with voltages up to and above 1000 V
In work the new method of definition of isolation's parameters in a three-phase symmetric electrical network with isolated neutral which is based on measurement of modules sizes of a linear voltage, voltages of phases C and A concerning to ground, after connection of active additional conductivity between phase A of electrical network and ground is shown and the analysis of a blunder of the developed method is made. The analysis of a blunder has shown, that the developed method provides satisfactory accuracy at definition of isolation's parameters, and also simplicity and the safety of operations in working electro installations of up to above 1000 V voltage.
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Development of mathematical models of digital protection devices from a single phase earth faults in networks with voltage 6–10 kV
The paper proposes an algorithm of a mathematical model of devices for digital protection from single-phase earth faults in 6-10 kV networks with automatic change of setpoint. It is achieved using the Mealy machine (Moore machine) for formalization and automatization of designing digital logic devices to determine a value of current single-phase earth fault and insulation conditions of 6-10 kV production networks at mining enterprises. The obtained flow-graph of the algorithm and the graph of the Mealy machine for digital devices are the basis for development of the control program, which defines the order for device operation. The developed algorithm for automatic determining the single-phase earth fault current in the 6-10 kV network provides the basis for developing a method and the device for automatic determining the single-phase earth fault current in the 6-10 kV network with an unambiguous definition of the necessary functional elements and their relationships.
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Development of mathematical models of digital protection devices from a single phase earth faults in networks with voltage 6–10 kV
The paper proposes an algorithm of a mathematical model of devices for digital protection from single-phase earth faults in 6-10 kV networks with automatic change of setpoint. It is achieved using the Mealy machine (Moore machine) for formalization and automatization of designing digital logic devices to determine a value of current single-phase earth fault and insulation conditions of 6-10 kV production networks at mining enterprises. The obtained flow-graph of the algorithm and the graph of the Mealy machine for digital devices are the basis for development of the control program, which defines the order for device operation. The developed algorithm for automatic determining the single-phase earth fault current in the 6-10 kV network provides the basis for developing a method and the device for automatic determining the single-phase earth fault current in the 6-10 kV network with an unambiguous definition of the necessary functional elements and their relationships.
- 1 January 2012
- Published by ACTA Press
Method for Determining Parameters of Isolation Network Voltage up to 1000 V in Mining Enterprises
- 1 January 2012
- Published by ACTA Press
Method for Determining Parameters of Isolation Network Voltage up to 1000 V in Mining Enterprises
- 1 January 2011
- Published by ACTA Press
Method for Determining Parameters of Isolation Network Voltage up to 1000 V in Mining Enterprises
- 1 January 2011
- Published by ACTA Press
Method for Determining Parameters of Isolation Network Voltage up to 1000 V in Mining Enterprises