Noureddine Ait Messaoudene
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Noureddine Ait Messaoudene has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Mohamed Wahib Naceur
Chemical Engineering Department, Faculty of Engineering, University of Blida, Blida, Algeria
6 shared publications - Khaled Imessad
Centre de Développement des Energies Renouvelables, CDER BP 62
3 shared publications - Mohamed Aichouni
Industrial Engineering Department, College of Engineering, University of Ha’il, Ha’il 81451, Saudi Arabia
3 shared publications - Abdellah Abdellah El-Hadj
Laboratory of Mechanics, Physics and Mathematical Modelling (LMP2M), University of Medea, Medea 26000, Algeria
2 shared publications Abdulaziz Ibraheem Al-Ghonamy
Binladin Research Chair on Quality and Productivity Improvement in the Construction Industry; College of Engineering, University of Hail, PO Box 2440, Ha’il 81441
2 shared publicationsB. Cheknane
2 shared publications
Latest Publications
- Open Access
Laminar mixed convection in an eccentric annular horizontal duct for a thermodependent non-Newtonian fluid
The present work focuses on the study of mixed convection of a purely viscous shear-thinning fluid in a horizontal annular eccentric duct. The inner and outer cylinders are heated with constant and uniform heat flux densities. The objective of this work is to study the effect of the variation of eccentricity, rheological behavior of the fluid as well as the thermodependency of the rheological parameters on the reorganization of the flow and thermal stratification caused by the buoyancy forces. At the entrance of the heating zone, the dynamic regime is assumed to be established and the temperature profile uniform. The conservation equations are solved numerically using a finite difference method with implicit schemes. A secondary azimuthal flow, induced by natural convection, develops downstream of the inlet section. This flow creates a stratification of the thermal field on a given section of the duct, which intensifies downstream from the entrance. On the other hand, the decrease in consistency with increasing temperature near the heated walls produces a centrifugal radial flow towards the walls. The presence of an eccentricity induces in turn a significant effect on the main dynamic field and the stratification of the thermal field. Two cases of upward and downward eccentricity are treated. These show that an upward shift increases the stratification of the thermal field, while the stratification begins to weaken from a certain amount of eccentricity in the case of downward shift. This represents an important result in terms of possible industrial applications. We may indeed conclude that an appropriate choice of downward eccentricity can reduce the thermal stratification, observed experimentally in the case of a concentric heated annular duct [1], when this stratification is undesirable. The choice of this eccentricity depends on rheological and thermal properties of the fluid.
Open AccessLaminar mixed convection in an eccentric annular horizontal duct for a thermodependent non-Newtonian fluid
The present work focuses on the study of mixed convection of a purely viscous shear-thinning fluid in a horizontal annular eccentric duct. The inner and outer cylinders are heated with constant and uniform heat flux densities. The objective of this work is to study the effect of the variation of eccentricity, rheological behavior of the fluid as well as the thermodependency of the rheological parameters on the reorganization of the flow and thermal stratification caused by the buoyancy forces. At the entrance of the heating zone, the dynamic regime is assumed to be established and the temperature profile uniform. The conservation equations are solved numerically using a finite difference method with implicit schemes. A secondary azimuthal flow, induced by natural convection, develops downstream of the inlet section. This flow creates a stratification of the thermal field on a given section of the duct, which intensifies downstream from the entrance. On the other hand, the decrease in consistency with increasing temperature near the heated walls produces a centrifugal radial flow towards the walls. The presence of an eccentricity induces in turn a significant effect on the main dynamic field and the stratification of the thermal field. Two cases of upward and downward eccentricity are treated. These show that an upward shift increases the stratification of the thermal field, while the stratification begins to weaken from a certain amount of eccentricity in the case of downward shift. This represents an important result in terms of possible industrial applications. We may indeed conclude that an appropriate choice of downward eccentricity can reduce the thermal stratification, observed experimentally in the case of a concentric heated annular duct [1], when this stratification is undesirable. The choice of this eccentricity depends on rheological and thermal properties of the fluid.
- 19 November 2020
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 144 (5) , 1749-1759
Modeling and optimization of a proton exchange membrane fuel cell using particle swarm algorithm with constriction coefficient
- 19 November 2020
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 144 (5) , 1749-1759
Modeling and optimization of a proton exchange membrane fuel cell using particle swarm algorithm with constriction coefficient
- 1 March 2017
- Published by Elsevier in Journal of Non-Newtonian Fluid Mechanics
- Vol. 241, 43-59
Energy growth in Hagen–Poiseuille flow of Herschel–Bulkley fluid
- 1 March 2017
- Published by Elsevier in Journal of Non-Newtonian Fluid Mechanics
- Vol. 241, 43-59
Energy growth in Hagen–Poiseuille flow of Herschel–Bulkley fluid
- 1 August 2015
- Published by Elsevier in Journal of Electrostatics
- Vol. 76, 171-177
Effects of corona discharges on a turbulent air flow: Simulation on a high-lift system
- 1 August 2015
- Published by Elsevier in Journal of Electrostatics
- Vol. 76, 171-177
Effects of corona discharges on a turbulent air flow: Simulation on a high-lift system
- Open Access
- 1 July 2015
- Published by Elsevier in Procedia - Social and Behavioral Sciences
- Vol. 195, 1371-1379
Creativity and Innovation among Gifted Saudi Students-An Empirical Study
- 1 July 2015
- Published by Elsevier in Procedia - Social and Behavioral Sciences
- Vol. 195, 1371-1379
Open AccessCreativity and Innovation among Gifted Saudi Students-An Empirical Study
- Open Access
- 5 December 2014
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 4 (4) , 271-283
Influence of operating parameters on electrocoagulation of C.I. disperse yellow 3
Influence of operating parameters on electrocoagulation of C.I. disperse yellow 3
- 5 December 2014
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 4 (4) , 271-283
Open AccessInfluence of operating parameters on electrocoagulation of C.I. disperse yellow 3
Influence of operating parameters on electrocoagulation of C.I. disperse yellow 3
- 20 November 2014
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 50 (9) , 1413-1420
Electrocoagulation of Direct Brown 2 (DB) and BF Cibacete Blue (CB) Using Aluminum Electrodes
This work studies the electrocoagulation (EC) process for the treatment of colored solutions of two dyes used in the textile industry: direct brown 2 (DB) and BF cibacete blue (CB) using aluminum electrodes in batch mode. Key EC parameters are investigated. The pH effect is found to be more important than the supporting electrolyte on the electrochemical process. The best EC efficiencies are as follows: for DB, 99.89% removal at 40 mg/L (pH 10, U = 12 V, tEC = 60 min); and for CB, 99.74% removal at 40 mg/L (pH 2.5, U = 12 V, tEC = 60 min). The power consumption is 16.56 and 17.04 kWh/m3 for DB and CB, respectively.
- 20 November 2014
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 50 (9) , 1413-1420
Electrocoagulation of Direct Brown 2 (DB) and BF Cibacete Blue (CB) Using Aluminum Electrodes
This work studies the electrocoagulation (EC) process for the treatment of colored solutions of two dyes used in the textile industry: direct brown 2 (DB) and BF cibacete blue (CB) using aluminum electrodes in batch mode. Key EC parameters are investigated. The pH effect is found to be more important than the supporting electrolyte on the electrochemical process. The best EC efficiencies are as follows: for DB, 99.89% removal at 40 mg/L (pH 10, U = 12 V, tEC = 60 min); and for CB, 99.74% removal at 40 mg/L (pH 2.5, U = 12 V, tEC = 60 min). The power consumption is 16.56 and 17.04 kWh/m3 for DB and CB, respectively.
- 1 November 2014
- Published by Elsevier in Renewable Energy
- Vol. 71, 589-597
Impact of passive cooling techniques on energy demand for residential buildings in a Mediterranean climate
- 1 November 2014
- Published by Elsevier in Renewable Energy
- Vol. 71, 589-597
Impact of passive cooling techniques on energy demand for residential buildings in a Mediterranean climate
- Open Access
- 23 September 2014
- Published by Science Publishing Group in International Journal of Environmental Monitoring and Analysis
- Vol. 2 (6) , 23-34
Coagulation and Chlorination of NOM and Algae in Water Treatment: A Review
Due to health concerns of natural organic matter (NOM) and algae presence in surface water and difficulties encountered in their removal in the water treatment, this paper reviews coagulation and chlorination processes which are largely used in water treatment technology. In the conventional water treatment, coagulation and slow filtration treatments have better efficiency to reduce the NOM in water especially for the hydrophobic portion than the hydrophilic one. However, the pre-chlorination treatment for raw water has been proved to increase the dissolved organic carbon concentration due to the lysis of algae cells and disinfection by-products formation. The impact of water treatment processes on disinfection by-products formation remains complex and variable, as demonstrated by recent literature. It is concluded that no pre-, no inter-, only post-chlorination preceded by optimised coagulation for NOM and algae removal is the best available technology for the conventional water treatment which would be reinforced by at least adsorption on powdered activated carbon or nanofiltration in the short terms. Finally, the conventional water treatment will not remain a viable solution for drinking water from source waters containing NOM as their quality deteriorates and water quality standards become more difficult to achieve.
- 23 September 2014
- Published by Science Publishing Group in International Journal of Environmental Monitoring and Analysis
- Vol. 2 (6) , 23-34
Open AccessCoagulation and Chlorination of NOM and Algae in Water Treatment: A Review
Due to health concerns of natural organic matter (NOM) and algae presence in surface water and difficulties encountered in their removal in the water treatment, this paper reviews coagulation and chlorination processes which are largely used in water treatment technology. In the conventional water treatment, coagulation and slow filtration treatments have better efficiency to reduce the NOM in water especially for the hydrophobic portion than the hydrophilic one. However, the pre-chlorination treatment for raw water has been proved to increase the dissolved organic carbon concentration due to the lysis of algae cells and disinfection by-products formation. The impact of water treatment processes on disinfection by-products formation remains complex and variable, as demonstrated by recent literature. It is concluded that no pre-, no inter-, only post-chlorination preceded by optimised coagulation for NOM and algae removal is the best available technology for the conventional water treatment which would be reinforced by at least adsorption on powdered activated carbon or nanofiltration in the short terms. Finally, the conventional water treatment will not remain a viable solution for drinking water from source waters containing NOM as their quality deteriorates and water quality standards become more difficult to achieve.
- Open Access
- 1 July 2014
- Published by AIP Publishing in Physics of Fluids
- Vol. 26 (7)
Numerical nonlinear analysis of subcritical Rayleigh-Bénard convection in a horizontal confined enclosure filled with non-Newtonian fluids
Non-Newtonian subcritical convection in a Rayleigh-Bénard configuration was investigated numerically, using rigid boundary conditions. The flow configuration consisted of a finite aspect ratio enclosure subject to a vertical temperature gradient, which was established by heating and cooling the lower and the upper walls by either a constant heat flux or by applying constant temperatures. The non-Newtonian fluid viscosity was modeled using the Carreau-Yasuda model. The convective flow was governed by the conservation equations, which were solved numerically using a finite difference method with a time-accurate scheme. For a shallow enclosure, when the walls were subject to constant heat fluxes, an asymptotic solution was derived assuming a parallel flow behavior. A comparison between the numerical and asymptotic solutions was performed. The effects of the controlling parameters, namely, the Rayleigh and the Prandtl numbers, and the fluid rheological parameters on the onset of subcritical convective flow were investigated. The threshold for the onset of subcritical convection was found to be well below the threshold of stationary convection and decreased considerably (with the fluid rheological parameters variation) as the fluid became more and more shear thinning. Depending on the governing parameters, steady and unsteady-periodic flow solutions were possible. Within a square enclosure with slip or no-slip vertical walls, maintaining the active walls at a constant heat flux or at constant temperature, the rheological subcritical flow behavior remained qualitatively the same, but led to different subcritical convection thresholds.
- 1 July 2014
- Published by AIP Publishing in Physics of Fluids
- Vol. 26 (7)
Open AccessNumerical nonlinear analysis of subcritical Rayleigh-Bénard convection in a horizontal confined enclosure filled with non-Newtonian fluids
Non-Newtonian subcritical convection in a Rayleigh-Bénard configuration was investigated numerically, using rigid boundary conditions. The flow configuration consisted of a finite aspect ratio enclosure subject to a vertical temperature gradient, which was established by heating and cooling the lower and the upper walls by either a constant heat flux or by applying constant temperatures. The non-Newtonian fluid viscosity was modeled using the Carreau-Yasuda model. The convective flow was governed by the conservation equations, which were solved numerically using a finite difference method with a time-accurate scheme. For a shallow enclosure, when the walls were subject to constant heat fluxes, an asymptotic solution was derived assuming a parallel flow behavior. A comparison between the numerical and asymptotic solutions was performed. The effects of the controlling parameters, namely, the Rayleigh and the Prandtl numbers, and the fluid rheological parameters on the onset of subcritical convective flow were investigated. The threshold for the onset of subcritical convection was found to be well below the threshold of stationary convection and decreased considerably (with the fluid rheological parameters variation) as the fluid became more and more shear thinning. Depending on the governing parameters, steady and unsteady-periodic flow solutions were possible. Within a square enclosure with slip or no-slip vertical walls, maintaining the active walls at a constant heat flux or at constant temperature, the rheological subcritical flow behavior remained qualitatively the same, but led to different subcritical convection thresholds.