Laura A. Watkins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Laura A. Watkins has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Krzysztof Laudanski
Department of Anesthesiology and Perioperative Care, Mayo Clinic, Rochester, MN 55902, USA
3 shared publications D Kurepa
Division of Neonatal-Perinatal Medicine, Cohen Children's Medical Center, New Hyde Park, NY, USA
1 shared publicationDalibor Kurepa
Department of Pediatrics, Division of Neonatology, Cohen Children's Medical Center, New Hyde Park, NY, USA
1 shared publicationDalibor N. Kurepa
Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY, USA
1 shared publicationDianxu Ren
Health and Community Systems, School of Nursing, University of Pittsburgh, Pennsylvania
1 shared publicationElizabeth Crago
Department of Acute and Tertiary Care, School of Nursing
1 shared publication
Latest Publications
- 9 October 2021
- Published by SAGE Publications in Journal of Intensive Care Medicine
- Vol. 37 (8) , 1029-1036
The Utility of Point-of-Care Ultrasound in the Pediatric Intensive Care Unit
Objectives: Point of care ultrasound (POCUS) in adult critical care environments has become the standard of care in many hospitals. A robust literature shows its benefits for both diagnosis and delivery of care. The utility of POCUS in the pediatric intensive care unit (PICU), however, is understudied. This study describes in a series of PICU patients the clinical indications, protocols, findings and impact of pediatric POCUS on clinical management. Design: Retrospective analysis of 200 consecutive POCUS scans performed by a PICU physician. Patients: Pediatric critical care patients who required POCUS scans over a 15-month period. Setting: The pediatric and cardiac ICUs at a tertiary pediatric care center. Interventions: Performance of a POCUS scan by a pediatric critical care attending with advanced training in ultrasonography. Measurement and Main Results: A total of 200 POCUS scans comprised of one or more protocols (lung and pleura, cardiac, abdominal, or vascular diagnostic protocols) were performed on 155 patients over a 15-month period. The protocols used for each scan reflected the clinical question to be answered. These 200 scans included 133 thoracic protocols, 110 cardiac protocols, 77 abdominal protocols, and 4 vascular protocols. In this series, 42% of scans identified pathology that required a change in therapy, 26% confirmed pathology consistent with the ongoing plans for new therapy, and 32% identified pathology that did not result in initiation of a new therapy. Conclusions: POCUS performed by a trained pediatric intensivist provided useful clinical information to guide patient management.
- 9 October 2021
- Published by SAGE Publications in Journal of Intensive Care Medicine
- Vol. 37 (8) , 1029-1036
The Utility of Point-of-Care Ultrasound in the Pediatric Intensive Care Unit
Objectives: Point of care ultrasound (POCUS) in adult critical care environments has become the standard of care in many hospitals. A robust literature shows its benefits for both diagnosis and delivery of care. The utility of POCUS in the pediatric intensive care unit (PICU), however, is understudied. This study describes in a series of PICU patients the clinical indications, protocols, findings and impact of pediatric POCUS on clinical management. Design: Retrospective analysis of 200 consecutive POCUS scans performed by a PICU physician. Patients: Pediatric critical care patients who required POCUS scans over a 15-month period. Setting: The pediatric and cardiac ICUs at a tertiary pediatric care center. Interventions: Performance of a POCUS scan by a pediatric critical care attending with advanced training in ultrasonography. Measurement and Main Results: A total of 200 POCUS scans comprised of one or more protocols (lung and pleura, cardiac, abdominal, or vascular diagnostic protocols) were performed on 155 patients over a 15-month period. The protocols used for each scan reflected the clinical question to be answered. These 200 scans included 133 thoracic protocols, 110 cardiac protocols, 77 abdominal protocols, and 4 vascular protocols. In this series, 42% of scans identified pathology that required a change in therapy, 26% confirmed pathology consistent with the ongoing plans for new therapy, and 32% identified pathology that did not result in initiation of a new therapy. Conclusions: POCUS performed by a trained pediatric intensivist provided useful clinical information to guide patient management.
- 1 June 2019
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 20 (6) , 591-592
Let’s Do It Right
- 1 June 2019
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 20 (6) , 591-592
Let’s Do It Right
- Open Access
- 30 May 2019
- Published by MDPI AG in Healthcare
- Vol. 7 (2) , 74
Self-Assessment of Preparedness among Critical Care Trainees Transitioning from Fellowship to Practice
This study evaluated the subjective assessment of preparedness needs of critical care trainees and recent graduates between 2013 and 2014. A questionnaire was developed and validated by the subcommittee of the In-Training Section of Society of Critical Care Medicine (SCCM). The survey was deployed twice between December 2013 and January 2014 via email to any trainee or individual graduated from a critical care fellowship within the previous three years. Six percent (180) of all individuals completed the survey, and 67% of respondents had recently interviewed for a job. Northeast was the preferred location for a job (47%), and academia was favored over private practice (80% vs. 15%). Of the respondents that secured an interview, 55% felt prepared for the interview, 67% felt prepared to build an adequate job portfolio, 33% received formal guidance from their mentor/training program. 89% of total respondents agreed it is important to participate in a formal training course in job search, portfolio development, and interviewing process. The preferred sources of training were equally distributed between their home institution, webinars, and SCCM. There is an ongoing need in education regarding the transition period from fellowship to practice.
- 30 May 2019
- Published by MDPI AG in Healthcare
- Vol. 7 (2) , 74
Open AccessSelf-Assessment of Preparedness among Critical Care Trainees Transitioning from Fellowship to Practice
This study evaluated the subjective assessment of preparedness needs of critical care trainees and recent graduates between 2013 and 2014. A questionnaire was developed and validated by the subcommittee of the In-Training Section of Society of Critical Care Medicine (SCCM). The survey was deployed twice between December 2013 and January 2014 via email to any trainee or individual graduated from a critical care fellowship within the previous three years. Six percent (180) of all individuals completed the survey, and 67% of respondents had recently interviewed for a job. Northeast was the preferred location for a job (47%), and academia was favored over private practice (80% vs. 15%). Of the respondents that secured an interview, 55% felt prepared for the interview, 67% felt prepared to build an adequate job portfolio, 33% received formal guidance from their mentor/training program. 89% of total respondents agreed it is important to participate in a formal training course in job search, portfolio development, and interviewing process. The preferred sources of training were equally distributed between their home institution, webinars, and SCCM. There is an ongoing need in education regarding the transition period from fellowship to practice.
- Open Access
- 28 December 2018
- Published by MDPI AG in Healthcare
- Vol. 7 (1) , 2
Interventions for Pediatric Sepsis and Their Impact on Outcomes: A Brief Review
In the current era, pediatric sepsis remains a public health problem of significant prevalence and impact. With mortality rates practically unchanged over the years, this review hopes to briefly summarize the epidemiology and the current interventions for pediatric sepsis and point towards possible areas of improvement. Most pediatric studies of sepsis are either small, retrospective or observational. Given information technology spreading across country, and a stronger presence of clinical networks, development of multicenter prospective studies over the next decade should enable better treatments for pediatric sepsis, and improved outcomes.
- 28 December 2018
- Published by MDPI AG in Healthcare
- Vol. 7 (1) , 2
Open AccessInterventions for Pediatric Sepsis and Their Impact on Outcomes: A Brief Review
In the current era, pediatric sepsis remains a public health problem of significant prevalence and impact. With mortality rates practically unchanged over the years, this review hopes to briefly summarize the epidemiology and the current interventions for pediatric sepsis and point towards possible areas of improvement. Most pediatric studies of sepsis are either small, retrospective or observational. Given information technology spreading across country, and a stronger presence of clinical networks, development of multicenter prospective studies over the next decade should enable better treatments for pediatric sepsis, and improved outcomes.
- 29 October 2018
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 178 (2) , 173-179
The superiority of point of care ultrasound in localizing central venous line tip position over time
The primary objective was to study agreement between X-rays and point of care ultrasound (POC-US) in determining central venous line (CVL) tip position. The secondary objective was to examine malposition rates over time using POC-US. Fifty-six neonates were enrolled who had a CVL placed. Initial X-rays and POC-US were obtained. POC-US was performed daily thereafter for the total of 6 days. US video clips were acquired in four standard echocardiographic views: subcostal, four-chamber, and short- and long-axis parasternal views. Gwet’s agreement coefficient (AC1) for agreement measured inter-rater reliability of X-rays and POC-US (correct position/malposition). A generalized linear mixed model for binary clustered data estimated malposition rate over time. All analyses were conducted using SAS version 9.4 and Agree Stat. The study included 108 “pairs” of X-rays and POC-US images. Agreement coefficient (AC1), with respect to correct position/malposition of CVL tip, was high AC1 = 0.872 (UVC-AC1 = 0.814, PICC-AC1 = 0.94). Among birth weight (BW) < 1000 g, 1000–1499 g, and BW > 1500 g, AC1 values were 0.922, 0.774, and 0.873, respectively. CVL tip malposition rate decreased over time.
- 29 October 2018
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 178 (2) , 173-179
The superiority of point of care ultrasound in localizing central venous line tip position over time
The primary objective was to study agreement between X-rays and point of care ultrasound (POC-US) in determining central venous line (CVL) tip position. The secondary objective was to examine malposition rates over time using POC-US. Fifty-six neonates were enrolled who had a CVL placed. Initial X-rays and POC-US were obtained. POC-US was performed daily thereafter for the total of 6 days. US video clips were acquired in four standard echocardiographic views: subcostal, four-chamber, and short- and long-axis parasternal views. Gwet’s agreement coefficient (AC1) for agreement measured inter-rater reliability of X-rays and POC-US (correct position/malposition). A generalized linear mixed model for binary clustered data estimated malposition rate over time. All analyses were conducted using SAS version 9.4 and Agree Stat. The study included 108 “pairs” of X-rays and POC-US images. Agreement coefficient (AC1), with respect to correct position/malposition of CVL tip, was high AC1 = 0.872 (UVC-AC1 = 0.814, PICC-AC1 = 0.94). Among birth weight (BW) < 1000 g, 1000–1499 g, and BW > 1500 g, AC1 values were 0.922, 0.774, and 0.873, respectively. CVL tip malposition rate decreased over time.
- 16 November 2017
- Published by Springer Nature in Journal of Perinatology
- Vol. 38 (1) , 11-22
Neonatal lung ultrasound exam guidelines
Point-of-care ultrasound (POC-US) is increasingly used especially in emergency and critical-care medicine. It is focused, quick and does not expose patients to ionizing radiation. It encompasses all organ systems and has well-defined indications. Lung ultrasound (LUS) represents one of the most exciting applications in the field of POC-US. It is particularly important to emphasize the role of LUS in neonatology due to the specific pathology inherent in lung immaturity as well as in the particular sensitivity of neonates to repeated radiation exposure. One of the main barriers to the more extensive use of the ultrasound technology is a lack of efficient and attractive training solutions followed by the structured quality-check assurance. In an effort to help bridge this gap, based on the most current literature, we developed creative and intuitive neonatal LUS algorithms. We hope they can serve as a clinical imaging guidelines and a valuable complement to the history and physical exam.
- 16 November 2017
- Published by Springer Nature in Journal of Perinatology
- Vol. 38 (1) , 11-22
Neonatal lung ultrasound exam guidelines
Point-of-care ultrasound (POC-US) is increasingly used especially in emergency and critical-care medicine. It is focused, quick and does not expose patients to ionizing radiation. It encompasses all organ systems and has well-defined indications. Lung ultrasound (LUS) represents one of the most exciting applications in the field of POC-US. It is particularly important to emphasize the role of LUS in neonatology due to the specific pathology inherent in lung immaturity as well as in the particular sensitivity of neonates to repeated radiation exposure. One of the main barriers to the more extensive use of the ultrasound technology is a lack of efficient and attractive training solutions followed by the structured quality-check assurance. In an effort to help bridge this gap, based on the most current literature, we developed creative and intuitive neonatal LUS algorithms. We hope they can serve as a clinical imaging guidelines and a valuable complement to the history and physical exam.
- 1 July 2017
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 125 (1) , 357-358
Wind of Change or Siren Song?
- 1 July 2017
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 125 (1) , 357-358
Wind of Change or Siren Song?
- 1 May 2017
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 45 (5) , 921-922
Times Are Changing in Pediatric Delirium*
- 1 May 2017
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 45 (5) , 921-922
Times Are Changing in Pediatric Delirium*
- 1 December 2014
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 42, A1438
324