Julien Chantel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Julien Chantel has a total of 424 co-authors. Here are the top co-authors by number of shared publications:
- Sébastien Merkel
Univ. Lille, CNRS, INRAE, Centrale Lille, UMR 8207—UMET—Unité Matériaux et Transformations 12 , F-59000 Lille
15 shared publications - Guillaume Morard
Sorbonne Universite
12 shared publications - Clemens Prescher
Institut für Geo- und Umweltnaturwissenschaften, Albert-Ludwigs-Universität Freiburg 31 , Hermann-Herder-Straße 5, 79104 Freiburg
11 shared publications - James D. McHardy
University of Edinburgh
11 shared publications - Karen Appel
European XFEL
11 shared publications - Rachel J. Husband
Deutsches Elektronen-Synchrotron DESY
11 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by American Physical Society (APS) in Physical Review B
- Vol. 114 (15) , 154101
Structure of niobium to 365 GPa using ultrafast x-ray diffraction and shock compression
The phase stability, crystal structure, and melting of Nb have been examined under high pressure shock compression to 365 GPa using ultrafast x-ray diffraction measurements on two x-ray free electron laser facilities. On compression, Nb remains stable in the bcc phase up to 220 GPa, with coexistence of bcc-Nb and liquid from 249 to 298 GPa, and complete melting at 301 GPa, with melt identified by diffuse liquid diffraction. Melting initiates at higher pressure than expected based on theoretical predictions, and the data consistently excludes the presence of other suggested phases of Nb at these pressures, including and hcp, thereby resolving the long-standing structural discrepancy. Singh-type strength analysis provides experimental evidence for a change in sign of the elastic anisotropy parameter at 121 GPa, consistent with the previously reported heat-induced hardening to heat-induced softening transition in Nb.
- 1 September 2026
- Published by American Physical Society (APS) in Physical Review B
- Vol. 114 (15) , 154101
Open AccessStructure of niobium to 365 GPa using ultrafast x-ray diffraction and shock compression
The phase stability, crystal structure, and melting of Nb have been examined under high pressure shock compression to 365 GPa using ultrafast x-ray diffraction measurements on two x-ray free electron laser facilities. On compression, Nb remains stable in the bcc phase up to 220 GPa, with coexistence of bcc-Nb and liquid from 249 to 298 GPa, and complete melting at 301 GPa, with melt identified by diffuse liquid diffraction. Melting initiates at higher pressure than expected based on theoretical predictions, and the data consistently excludes the presence of other suggested phases of Nb at these pressures, including and hcp, thereby resolving the long-standing structural discrepancy. Singh-type strength analysis provides experimental evidence for a change in sign of the elastic anisotropy parameter at 121 GPa, consistent with the previously reported heat-induced hardening to heat-induced softening transition in Nb.
- Open Access
- 10 August 2026
- Published by American Physical Society (APS) in Physical Review B
- Vol. 114 (9)
Observation of body-centered cubic iron above 200 gigapascals
The crystallographic structure of iron under extreme conditions is a key benchmark for state-of-the-art experimental and computational methods. Moreover, it plays a crucial role in our understanding of planetary cores, as it strongly influences the interpretation of observational data and, consequently, our knowledge of their internal structure and dynamics. However, even the crystal structure of pure solid iron under Earth's core conditions remains uncertain, with the commonly expected hexagonal close-packed phase being energetically competitive with several cubic structures. In this study, iron was compressed in a diamond anvil cell to pressures exceeding 200 GPa and dynamically probed near its melting point using MHz-frequency x-ray pulses from the European X-ray Free-Electron Laser. In the pressure range between 120 and 160 GPa, the high temporal resolution of the structural snapshots at elevated temperatures revealed the face-centered cubic phase, extending its observed stability to higher pressures than previously reported. Brief appearances of intermediate or disordered phases, including body-centered cubic (bcc) and stacking-faulted structures, were also observed. Above 230 GPa, new diffraction reflections emerged at high temperatures and are interpreted as evidence for the nucleation of a previously unreported phase, which subsequently evolved into a powderlike diffraction pattern characteristic of the bcc structure. The unprecedented time resolution of the structural data acquired during rapid heating and cooling cycles provides insights into the kinetics and mechanisms of phase transformations in iron at these extreme pressures.
- 10 August 2026
- Published by American Physical Society (APS) in Physical Review B
- Vol. 114 (9)
Open AccessObservation of body-centered cubic iron above 200 gigapascals
The crystallographic structure of iron under extreme conditions is a key benchmark for state-of-the-art experimental and computational methods. Moreover, it plays a crucial role in our understanding of planetary cores, as it strongly influences the interpretation of observational data and, consequently, our knowledge of their internal structure and dynamics. However, even the crystal structure of pure solid iron under Earth's core conditions remains uncertain, with the commonly expected hexagonal close-packed phase being energetically competitive with several cubic structures. In this study, iron was compressed in a diamond anvil cell to pressures exceeding 200 GPa and dynamically probed near its melting point using MHz-frequency x-ray pulses from the European X-ray Free-Electron Laser. In the pressure range between 120 and 160 GPa, the high temporal resolution of the structural snapshots at elevated temperatures revealed the face-centered cubic phase, extending its observed stability to higher pressures than previously reported. Brief appearances of intermediate or disordered phases, including body-centered cubic (bcc) and stacking-faulted structures, were also observed. Above 230 GPa, new diffraction reflections emerged at high temperatures and are interpreted as evidence for the nucleation of a previously unreported phase, which subsequently evolved into a powderlike diffraction pattern characteristic of the bcc structure. The unprecedented time resolution of the structural data acquired during rapid heating and cooling cycles provides insights into the kinetics and mechanisms of phase transformations in iron at these extreme pressures.
- Open Access
- 23 January 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (4)
Metrology for femtosecond pulsed x-ray heating in diamond anvil cell experiments at the European XFEL: Revisiting the iron phase diagram up to 150 GPa
The development of pulsed intense x-ray sources, such as free electron laser, offers new avenues for high pressure experiments. Here, we study the feasibility and metrology of x-ray heating in diamond anvil cells at the European x-ray free electron laser. This method enables one to volumetrically heat the sample while inhibiting chemical migration and probing the crystallographic structure of the sample throughout the heating with a high repetition rate. We focus our study on iron, whose phase diagram is well established up to 100 GPa, to explore the possibilities and limitations of this technique. We volumetrically heat iron samples at starting pressures ranging from 10 to 138 GPa, using the x-ray beam pulsed at 4.5 MHz in a serial pump-and-probe experimental design. Experimental challenges arise from temperature gradients within the sample, changes in temperature at the 100 ns timescale, the difficulty of direct temperature estimates, the effect of thermal pressure, and the presence of metastable crystallites due to rapid cycles of heating and cooling. Hence, we develop a multi-crystal-like data processing method that allows us to account for sample heterogeneity in probed conditions. We then calibrate our measurements using known physical properties of iron under pressure. Thermal pressure in our experiments increases from 4% of the isochoric prediction at 10 GPa to 23% at 138 GPa, and we show that our data are in agreement with most previous observations of iron in this pressure range. The method can now be implemented at higher pressures and temperatures and on materials with unknown phase diagrams.
- 23 January 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (4)
Open AccessMetrology for femtosecond pulsed x-ray heating in diamond anvil cell experiments at the European XFEL: Revisiting the iron phase diagram up to 150 GPa
The development of pulsed intense x-ray sources, such as free electron laser, offers new avenues for high pressure experiments. Here, we study the feasibility and metrology of x-ray heating in diamond anvil cells at the European x-ray free electron laser. This method enables one to volumetrically heat the sample while inhibiting chemical migration and probing the crystallographic structure of the sample throughout the heating with a high repetition rate. We focus our study on iron, whose phase diagram is well established up to 100 GPa, to explore the possibilities and limitations of this technique. We volumetrically heat iron samples at starting pressures ranging from 10 to 138 GPa, using the x-ray beam pulsed at 4.5 MHz in a serial pump-and-probe experimental design. Experimental challenges arise from temperature gradients within the sample, changes in temperature at the 100 ns timescale, the difficulty of direct temperature estimates, the effect of thermal pressure, and the presence of metastable crystallites due to rapid cycles of heating and cooling. Hence, we develop a multi-crystal-like data processing method that allows us to account for sample heterogeneity in probed conditions. We then calibrate our measurements using known physical properties of iron under pressure. Thermal pressure in our experiments increases from 4% of the isochoric prediction at 10 GPa to 23% at 138 GPa, and we show that our data are in agreement with most previous observations of iron in this pressure range. The method can now be implemented at higher pressures and temperatures and on materials with unknown phase diagrams.
- Open Access
- 21 October 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (15)
X-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids
We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren [B. E. Warren, Acta Crystallogr. 6, 803 (1953)]. We compare the predictions of our model with femtosecond x-ray diffraction patterns gathered from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density instrument of the European X-Ray Free-Electron Laser facility and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.
- 21 October 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (15)
Open AccessX-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids
We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren [B. E. Warren, Acta Crystallogr. 6, 803 (1953)]. We compare the predictions of our model with femtosecond x-ray diffraction patterns gathered from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density instrument of the European X-Ray Free-Electron Laser facility and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.
- Open Access
X-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids
We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren. We compare the predictions of our model with femtosecond x-ray diffraction patterns obtained from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density (HED) instrument of the European X-Ray Free-Electron Laser (EuXFEL), and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show that: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.
Open AccessX-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids
We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren. We compare the predictions of our model with femtosecond x-ray diffraction patterns obtained from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density (HED) instrument of the European X-Ray Free-Electron Laser (EuXFEL), and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show that: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.
- Open Access
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL
In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
Open AccessCalibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL
In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.
- Top Cited PapersOpen Access
- 21 May 2025
- Published by Springer Nature in Nature
- Vol. 642 (8067) , 351-355
The structure of liquid carbon elucidated by in situ X-ray diffraction
Carbon has a central role in biology and organic chemistry, and its solid allotropes provide the basis of much of our modern technology1. However, the liquid form of carbon remains nearly uncharted2, and the structure of liquid carbon and most of its physical properties are essentially unknown3. But liquid carbon is relevant for modelling planetary interiors4,5 and the atmospheres of white dwarfs6, as an intermediate state for the synthesis of advanced carbon materials7,8, inertial confinement fusion implosions9, hypervelocity impact events on carbon materials10 and our general understanding of structured fluids at extreme conditions11. Here we present a precise structure measurement of liquid carbon at pressures of around 1 million atmospheres obtained by in situ X-ray diffraction at an X-ray free-electron laser. Our results show a complex fluid with transient bonding and approximately four nearest neighbours on average, in agreement with quantum molecular dynamics simulations. The obtained data substantiate the understanding of the liquid state of one of the most abundant elements in the universe and can test models of the melting line. The demonstrated experimental abilities open the path to performing similar studies of the structure of liquids composed of light elements at extreme conditions.
- 21 May 2025
- Published by Springer Nature in Nature
- Vol. 642 (8067) , 351-355
Top Cited PapersOpen AccessThe structure of liquid carbon elucidated by in situ X-ray diffraction
Carbon has a central role in biology and organic chemistry, and its solid allotropes provide the basis of much of our modern technology1. However, the liquid form of carbon remains nearly uncharted2, and the structure of liquid carbon and most of its physical properties are essentially unknown3. But liquid carbon is relevant for modelling planetary interiors4,5 and the atmospheres of white dwarfs6, as an intermediate state for the synthesis of advanced carbon materials7,8, inertial confinement fusion implosions9, hypervelocity impact events on carbon materials10 and our general understanding of structured fluids at extreme conditions11. Here we present a precise structure measurement of liquid carbon at pressures of around 1 million atmospheres obtained by in situ X-ray diffraction at an X-ray free-electron laser. Our results show a complex fluid with transient bonding and approximately four nearest neighbours on average, in agreement with quantum molecular dynamics simulations. The obtained data substantiate the understanding of the liquid state of one of the most abundant elements in the universe and can test models of the melting line. The demonstrated experimental abilities open the path to performing similar studies of the structure of liquids composed of light elements at extreme conditions.
- Open Access
- 21 April 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 137 (15)
Femtosecond temperature measurements of laser-shocked copper deduced from the intensity of the x-ray thermal diffuse scattering
We present 50-fs, single-shot measurements of the x-ray thermal diffuse scattering (TDS) from copper foils that have been shocked via nanosecond laser ablation up to pressures above ∼135 GPa. We hence deduce the x-ray Debye–Waller factor, providing a temperature measurement. The targets were laser-shocked with the DiPOLE 100-X laser at the High Energy Density endstation of the European X-ray Free-Electron Laser. Single x-ray pulses, with a photon energy of 18 keV, were scattered from the samples and recorded on Varex detectors. Despite the targets being highly textured (as evinced by large variations in the elastic scattering) and with such texture changing upon compression, the absolute intensity of the azimuthally averaged inelastic TDS between the Bragg peaks is largely insensitive to these changes, and allowing for both Compton scattering and the low-level scattering from a sacrificial ablator layer provides a reliable measurement of T/ΘD2, where ΘD is the Debye temperature. We compare our results with the predictions of the SESAME 3336 and LEOS 290 equations of state for copper and find good agreement within experimental errors. We, thus, demonstrate that single-shot temperature measurements of dynamically compressed materials can be made via thermal diffuse scattering of XFEL radiation.
- 21 April 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 137 (15)
Open AccessFemtosecond temperature measurements of laser-shocked copper deduced from the intensity of the x-ray thermal diffuse scattering
We present 50-fs, single-shot measurements of the x-ray thermal diffuse scattering (TDS) from copper foils that have been shocked via nanosecond laser ablation up to pressures above ∼135 GPa. We hence deduce the x-ray Debye–Waller factor, providing a temperature measurement. The targets were laser-shocked with the DiPOLE 100-X laser at the High Energy Density endstation of the European X-ray Free-Electron Laser. Single x-ray pulses, with a photon energy of 18 keV, were scattered from the samples and recorded on Varex detectors. Despite the targets being highly textured (as evinced by large variations in the elastic scattering) and with such texture changing upon compression, the absolute intensity of the azimuthally averaged inelastic TDS between the Bragg peaks is largely insensitive to these changes, and allowing for both Compton scattering and the low-level scattering from a sacrificial ablator layer provides a reliable measurement of T/ΘD2, where ΘD is the Debye temperature. We compare our results with the predictions of the SESAME 3336 and LEOS 290 equations of state for copper and find good agreement within experimental errors. We, thus, demonstrate that single-shot temperature measurements of dynamically compressed materials can be made via thermal diffuse scattering of XFEL radiation.
- Open Access
- 25 February 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-9
The structure and stability of Fe4+xS3 and its potential to form a Martian inner core
Seismic, geodetic and cosmochemical evidence point to Mars having a sulfur-rich liquid core. Due to the similarity between estimates of the core’s sulfur content and the iron–iron sulfide eutectic composition at core conditions, it has been concluded that temperatures are too high for Mars to have an inner core. Recent low density estimates for the core, however, appear consistent with sulfur contents that are higher than the eutectic composition, leading to the possibility that an inner core could form from a high-pressure iron sulfide phase. Here we report the crystal structure of a phase with the formula Fe4+xS3, the iron content of which increases with temperature, approaching the stoichiometry Fe5S3 under Martian inner core conditions. We show that Fe4+xS3 has a higher density than the liquid Martian core and that a Fe4+xS3 inner core would crystalize if temperatures fall below 1960 (±105) K at the center of Mars.
- 25 February 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-9
Open AccessThe structure and stability of Fe4+xS3 and its potential to form a Martian inner core
Seismic, geodetic and cosmochemical evidence point to Mars having a sulfur-rich liquid core. Due to the similarity between estimates of the core’s sulfur content and the iron–iron sulfide eutectic composition at core conditions, it has been concluded that temperatures are too high for Mars to have an inner core. Recent low density estimates for the core, however, appear consistent with sulfur contents that are higher than the eutectic composition, leading to the possibility that an inner core could form from a high-pressure iron sulfide phase. Here we report the crystal structure of a phase with the formula Fe4+xS3, the iron content of which increases with temperature, approaching the stoichiometry Fe5S3 under Martian inner core conditions. We show that Fe4+xS3 has a higher density than the liquid Martian core and that a Fe4+xS3 inner core would crystalize if temperatures fall below 1960 (±105) K at the center of Mars.
- Open Access
- 16 December 2024
- Published by Springer Nature in Research Square
The structure and stability of Fe4+xS3 and its potential to form a Martian inner core
Seismic, geodetic and cosmochemical evidence point to Mars having a sulfur-rich liquid core. Due to the similarity between estimates of the core’s sulfur content and the iron - iron sulfide eutectic composition at core conditions, it has been concluded that temperatures are too high for Mars to have an inner core. Recent low density estimates for the core, however, appear consistent with sulfur contents that are higher than the eutectic composition, leading to the possibility that an inner core could form from a high-pressure iron sulfide phase. Here we report the crystal structure of a phase with the formula Fe4 + xS3, the iron content of which increases with temperature, approaching the stoichiometry Fe5S3 under Martian inner core conditions. We show that Fe4 + xS3 has a higher density than the liquid Martian core and that a Fe4 + xS3 inner core would crystalize if temperatures fall below 1960 (± 105) K at the center of Mars.
- 16 December 2024
- Published by Springer Nature in Research Square
Open AccessThe structure and stability of Fe4+xS3 and its potential to form a Martian inner core
Seismic, geodetic and cosmochemical evidence point to Mars having a sulfur-rich liquid core. Due to the similarity between estimates of the core’s sulfur content and the iron - iron sulfide eutectic composition at core conditions, it has been concluded that temperatures are too high for Mars to have an inner core. Recent low density estimates for the core, however, appear consistent with sulfur contents that are higher than the eutectic composition, leading to the possibility that an inner core could form from a high-pressure iron sulfide phase. Here we report the crystal structure of a phase with the formula Fe4 + xS3, the iron content of which increases with temperature, approaching the stoichiometry Fe5S3 under Martian inner core conditions. We show that Fe4 + xS3 has a higher density than the liquid Martian core and that a Fe4 + xS3 inner core would crystalize if temperatures fall below 1960 (± 105) K at the center of Mars.