GFGuy R. Fogel

Guy R. Fogel

*This is an algorithmically generated author record based on publicly available information.

Guy R. Fogel has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Biomechanics of Artificial Disc Replacements Adjacent to a 2-Level Fusion in 4-Level Hybrid Constructs: An In Vitro Investigation

    by Zhenhua Liao, Guy R. Fogel, Na Wei, Hongsheng Gu, Weiqiang Liu

    The ideal procedure for multilevel cervical degenerative disc diseases remains controversial. Recent studies on hybrid surgery combining anterior cervical discectomy and fusion (ACDF) and artificial cervical disc replacement (ACDR) for 2-level and 3-level constructs have been reported in the literature. The purpose of this study was to estimate the biomechanics of 3 kinds of 4-level hybrid constructs, which are more likely to be used clinically compared to 4-level arthrodesis. Eighteen human cadaveric spines (C2–T1) were evaluated in different testing conditions: intact, with 3 kinds of 4-level hybrid constructs (hybrid C3–4 ACDR+C4–6 ACDF+C6–7ACDR; hybrid C3–5ACDF+C5–6ACDR+C6–7ACDR; hybrid C3–4ACDR+C4–5ACDR+C5–7ACDF); and 4-level fusion. Four-level fusion resulted in significant decrease in the C3–C7 ROM compared with the intact spine. The 3 different 4-level hybrid treatment groups caused only slight change at the instrumented levels compared to intact except for flexion. At the adjacent levels, 4-level fusion resulted in significant increase of contribution of both upper and lower adjacent levels. However, for the 3 hybrid constructs, significant changes of motion increase far lower than 4P at adjacent levels were only noted in partial loading conditions. No destabilizing effect or hypermobility were observed in any 4-level hybrid construct. Four-level fusion significantly eliminated motion within the construct and increased motion at the adjacent segments. For all 3 different 4-level hybrid constructs, ACDR normalized motion of the index segment and adjacent segments with no significant hypermobility. Compared with the 4-level ACDF condition, the artificial discs in 4-level hybrid constructs had biomechanical advantages compared to fusion in normalizing adjacent level motion.


  • Open Access

    Biomechanics of Hybrid Anterior Cervical Fusion and Artificial Disc Replacement in 3-Level Constructs: An In Vitro Investigation

    by Zhenhua Liao, Guy R. Fogel, Ting Pu, Hongsheng Gu, Weiqiang Liu

    The ideal surgical approach for cervical disk disease remains controversial, especially for multilevel cervical disease. The purpose of this study was to investigate the biomechanics of the cervical spine after 3-level hybrid surgery compared with 3-level anterior cervical discectomy and fusion (ACDF). Eighteen human cadaveric spines (C2-T1) were evaluated under displacement-input protocol. After intact testing, a simulated hybrid construct or fusion construct was created between C3 to C6 and tested in the following 3 conditions: 3-level disc plate disc (3DPD), 3-level plate disc plate (3PDP), and 3-level plate (3P). Compared to intact, almost 65~80% of motion was successfully restricted at C3-C6 fusion levels (p0.05). 3PDP construct resulted in significant decrease of ROM at C3-C6 levels less than 3P (p<0.05). Both 3DPD and 3PDP caused significant reduction of ROM at the arthrodesis level and produced motion increase at the arthroplasty level. For adjacent levels, 3P resulted in markedly increased contribution of both upper and lower adjacent levels (p<0.05). Significant motion increases lower than 3P were only noted at partly adjacent levels in some conditions for 3DPD and 3PDP (p<0.05). ACDF eliminated motion within the construct and greatly increased adjacent motion. Artificial cervical disc replacement normalized motion of its segment and adjacent segments. While hybrid conditions failed to restore normal motion within the construct, they significantly normalized motion in adjacent segments compared with the 3-level ACDF condition. The artificial disc in 3-level constructs has biomechanical advantages compared to fusion in normalizing motion.


  • Biomechanical Analysis of TLIF Constructs with Cortical versus Pedicle Bilateral Screw-Rod Fixation

    by Edward K. Nomoto, Alexandre Rasouli, Guy R. Fogel, Alexander W. Turner

  • Biomechanical Stability of Lateral Interbody Implants and Supplemental Fixation in a Cadaveric Degenerative Spondylolisthesis Model

    by Guy R. Fogel, Alexander W. L. Turner, Zachary A. Dooley, G. Bryan Cornwall

    In vitro cadaveric biomechanical study of lateral interbody cages and supplemental fixation in a degenerative spondylolisthesis (DS) model. To investigate changes in shear and flexion-extension stability of lateral interbody fusion constructs. Instability associated with DS may increase postoperative treatment complications. Several groups have investigated DS in cadaveric spines. Extreme lateral interbody fusion (XLIF) cages with supplemental fixation have not previously been examined using a DS model. Seven human cadaveric L4-L5 motion segments were evaluated using flexion-extension moments to ±7.5 N·m and anterior-posterior (A-P) shear loading of 150 N with a static axial compressive load of 300 N. Conditions were: (1) intact segment, (2) DS simulation with facet resection and lateral discectomy, (3) standalone XLIF cage, (4) XLIF cage with (1) lateral plate, (2) lateral plate and unilateral pedicle screws contralateral to the plate (PS), (3) unilateral PS, (4) bilateral PS, (5) spinous process plate, and (6) lateral plate and spinous process plate. Flexion-extension range of motion (ROM) data were compared between conditions and with results from a previous study without DS simulation. A-P shear displacements were compared between conditions. Flexion-extension ROM after DS destabilization increased significantly by 181% of intact ROM. With the XLIF cage alone, ROM decreased to 77% of intact. All conditions were less stable than corresponding conditions with intact posterior elements except those including the spinous process plate. Under shear loading, A-P displacement with the XLIF cage alone increased by 2.2 times intact. Bilateral PS provided the largest reduction of A-P displacement, whereas the spinous process plate alone provided the least. This is the first in vitro shear load testing of XLIF cages with supplemental fixation in a cadaveric DS model. The variability in sagittal plane construct stability, including significantly increased flexion-extension ROM found with most fixation conditions including bilateral PS may explain some clinical treatment complications in DS with residual instability. N/A.


  • Biomechanics of lateral lumbar interbody fusion constructs with lateral and posterior plate fixation

    by Guy R. Fogel, Rachit D. Parikh, Stephen I. Ryu, Alexander W. L. Turner

    Object: Lumbar interbody fusion is indicated in the treatment of degenerative conditions. Laterally inserted interbody cages significantly decrease range of motion (ROM) compared with other cages. Supplemental fixation options such as lateral plates or spinous process plates have been shown to provide stability and to reduce morbidity. The authors of the current study investigate the in vitro stability of the interbody cage with a combination of lateral and spinous process plate fixation and compare this method to the established bilateral pedicle screw fixation technique. Methods: Ten L1–5 specimens were evaluated using multidirectional nondestructive moments (± 7.5 N·m), with a custom 6 degrees-of-freedom spine simulator. Intervertebral motions (ROM) were measured optoelectronically. Each spine was evaluated under the following conditions at the L3–4 level: intact; interbody cage alone (stand-alone); cage supplemented with lateral plate; cage supplemented with ipsilateral pedicle screws; cage supplemented with bilateral pedicle screws; cage supplemented with spinous process plate; and cage supplemented with a combination of lateral plate and spinous process plate. Intervertebral rotations were calculated, and ROM data were normalized to the intact ROM data. Results: The stand-alone laterally inserted interbody cage significantly reduced ROM with respect to the intact state in flexion-extension (31.6% intact ROM, p < 0.001), lateral bending (32.5%, p < 0.001), and axial rotation (69.4%, p = 0.002). Compared with the stand-alone condition, addition of a lateral plate to the interbody cage did not significantly alter the ROM in flexion-extension (p = 0.904); however, it was significantly decreased in lateral bending and axial rotation (p < 0.001). The cage supplemented with a lateral plate was not statistically different from bilateral pedicle screws in lateral bending (p = 0.579). Supplemental fixation using a spinous process plate was not significantly different from bilateral pedicle screws in flexion-extension (p = 0.476). The combination of lateral plate and spinous process plate was not statistically different from the cage supplemented with bilateral pedicle screws in all the loading modes (p ≥ 0.365). Conclusions: A combination of lateral and spinous process plate fixation to supplement a laterally inserted interbody cage helps achieve rigidity in all motion planes similar to that achieved with bilateral pedicle screws.


  • Evaluation of a Single-Dose, Extended-Release Epidural Morphine Formulation for Pain Control After Lumbar Spine Surgery

    by Joseph C. Vineyard, John S. Toohey, Arvo Neidre, Guy Fogel, Robert Joyner

    DepoDur, an extended-release epidural morphine, has been used effectively for postoperative pain control following many orthopaedic and general surgery procedures and has provided prolonged analgesia when compared with Duramorph. The goal of this article was to compare the safety and analgesic efficacy of DepoDur versus Duramorph after lumbar spine surgery. A prospective, randomized, double-blind clinical study was completed at a single extended-stay ambulatory surgery center. All patients over 18 undergoing posterior lumbar spine fusions were considered for the study. Sixty patients were randomly assigned to a control or treatment group. The control group received DepoDur before surgery, while the treatment group received Duramorph. Although results show no significant differences between the two groups in postoperative visual analog pain scale scores, use of pain medication, and adverse events, subjects receiving DepoDur were less likely to receive Naloxone and oxygen supplementation, experience nausea or fever, and were more likely to experience hypotension. DepoDur proved to be safe and effective, offering similar prolonged analgesic activity when compared with Duramorph.


  • Biomechanical Analysis and Review of Lateral Lumbar Fusion Constructs

    by Andrew Cappuccino, G. Bryan Cornwall, Alexander W. L. Turner, Guy R. Fogel, Huy T. Duong, Kee D. Kim, Darrel S. Brodke

    Biomechanical study and the review of literature on lumbar interbody fusion constructs. To demonstrate the comparative stabilizing effects of lateral interbody fusion with various supplemental internal fixation options. Lumbar interbody fusion procedures are regularly performed using anterior, posterior, and more recently, lateral approaches. The biomechanical profile of each is determined by the extent of resection of local supportive structures, implant size and orientation, and the type of supplemental internal fixation used. Pure moment flexibility testing was performed using a custom-built 6 degree-of-freedom system to apply a moment of ±7.5 Nm in each motion plane, while motion segment kinematics were evaluated using an optoelectronic motion system. Constructs tested included the intact spine, stand-alone extreme lateral interbody implant, interbody implant with lateral plate, unilateral and bilateral pedicle screw fixation. These results were evaluated against those from literature-reported biomechanical studies of other lumbar interbody constructs. All conditions demonstrated a statistically significant reduction in range of motion (ROM) as a percentage of intact. In flexion-extension, ROM was 31.6% stand-alone, 32.5% lateral fixation, and 20.4% and 13.0% unilateral and bilateral pedicle screw fixation, respectively. In lateral bending, the trend was similar with greater reduction with lateral fixation than in flexion-extension; ROM was 32.5% stand-alone, 15.9% lateral fixation, and 21.6% and 14.4% unilateral and bilateral pedicle screw fixation. ROM was greatest in axial rotation; 69.4% stand-alone, 53.4% lateral fixation, and 51.3% and 41.7% unilateral and bilateral pedicle screw fixation, respectively. The extreme lateral interbody construct provided the largest stand-alone reduction in ROM compared with literature-reported ALIF and TLIF constructs. Supplemental bilateral pedicle screw-based fixation provided the overall greatest reduction in ROM, similar among all interbody approach techniques. Lateral fixation and unilateral pedicle screw fixation provided intermediate reductions in ROM. Clinically, surgeons may evaluate these comparative results to choose fixation options commensurate with the stability requirements of individual patients.


    • 1 January 2009
      • Vol. 18  (2) , 77-82

    Outcomes of posterior lumbar interbody fusion with the 9-mm width lumbar I/F cage and the variable screw placement system.

    by Guy R Fogel, John S Toohey, Arvo Neidre, John W Brantigan

    Posterior lumbar interbody fusion (PLIF) using interbody cages and posterior pedicle screw fixation has increased the successful fusion rate to nearly 100% in the lumbar spine. In the design of the cage, only the surface area of the opening for bone graft contact with the endplates varied with the width of the cage. When space is limited, the 9-mm width cages may be the largest size that can be used. Fusion is potentially compromised by the smaller surface area of bone graft. It is important to study the clinical and fusion success of these narrow cages. The authors report 90 patients who had PLIF with 9-mm Lumbar I/F Cages and pedicle screws. Minimum follow-up was 24 months (range, 2-5 years). Seventy-five patients (83%) had clinical success, and 15 (17%) were clinically unsuccessful. Fusion was successful in 82 patients (91.1%). Fusion success with the 9-mm cage was statistically lower than previously reported for the implant system as a whole (p = .0015). Mechanical failure did not occur with 9-mm cage usage.