TDTammy Lynn Haut Donahue

Tammy Lynn Haut Donahue

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tammy Lynn Haut Donahue has a total of 95 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Removal of the infrapatellar fat pad and associated synovium benefits female guinea pigs in the Dunkin Hartley model of idiopathic osteoarthritis

    by Maryam F. Afzali, Madeline M. Sykes, Lindsey H. Burton, Kayley M. Patton, Koryn R. Lee, Cassie Seebart, Nicole Vigon, Ryan Ek, Gerardo E. Narez, Angela J. Marolf, et al.

    Background: Several tissues contribute to the onset and advancement of knee osteoarthritis (OA). One tissue type that is worthy of closer evaluation, particularly in the context of sex, is the infrapatellar fat pad (IFP). We previously demonstrated that removal of the IFP had short-term beneficial effects for a cohort of male Dunkin-Hartley guinea pigs. The present project was designed to elucidate the influence of IFP removal in females of this OA-prone strain. It was hypothesized that resection of the IFP would reduce the development of OA in knees of a rodent model predisposed to the disease. Methods: Female guinea pigs (n=16) were acquired at an age of 2.5 months. Surgical removal of the IFP and associated synovium complex (IFP/SC) was executed at 3 months of age. One knee had the IFP/SC resected; a comparable sham surgery was performed on the contralateral knee. All animals were subjected to voluntary enclosure monitoring and dynamic weight-bearing, as well as compulsory treadmill-based gait analysis monthly; baseline data was collected prior to surgery. Guinea pigs were euthanized at 7 months. Knees from eight animals were evaluated via histology, mRNA expression, and immunohistochemistry (IHC); knees from the remaining eight animals were allocated to microcomputed tomography (microCT), biomechanical analyses (whole joint testing and indentation relaxation testing), and atomic absorption spectroscopy (AAS). Results: Fibrous connective tissue (FCT) replaced the IFP/SC. Mobility/gait data indicated that unilateral IFP/SC removal did not affect bilateral hindlimb movement. MicroCT demonstrated that osteophytes were not a significant feature of OA in this sex; however, trabecular thickness (TbTh) in medial femorae decreased in knees containing the FCT. Histopathology scores were predominantly influenced by changes in the lateral tibia, which demonstrated that histologic signs of OA were increased in knees containing the native IFP/SC versus those with the FCT. Similarly, indentation testing demonstrated higher instantaneous and equilibrium moduli in the lateral tibial articular cartilage of control knees with native IFPs. AAS of multiple tissue types associated with the knee revealed that zinc was the major trace element influenced by removal of the IFP/SC. Conclusions: Our data suggest that the IFP/SC is a significant component driving knee OA in female guinea pigs and that resection of this tissue prior to disease has short-term benefits. Specifically, the formation of the FCT in place of the native tissue resulted in decreased cartilage-related OA changes, as demonstrated by reduced Osteoarthritis Research Society International (OARSI) histology scores, as well as changes in transcript, protein, and cartilage indentation analyses. Importantly, this model provides evidence that sex needs to be considered when investigating responses and associated mechanisms seen with this intervention.


  • The Effect of Anterior Cruciate Ligament Reconstruction with an Electropsun Scaffold on Tibiofemoral Contact Mechanics

    by Hannah Pauly, Kristine Fischenich, Daniel Kelly, Ketul Popat, Jeremiah Easley, Ross H. Palmer, Tammy L. Haut Donahue

    Surgical reconstruction of the torn ACL is performed to restore native contact mechanics. Drawbacks to traditional ACL repair techniques motivate the development of a tissue engineered ACL scaffold. Our group has developed a hierarchical electrospun polycaprolactone (PCL) scaffold that consists of rolled nanofiber bundles attached at each end with solvent-case blocks of PCL. The goal of this study was to compare ovine cadaver tibiofemoral contact mechanics after ACL reconstruction with the electrospun scaffold to a clinically applicable ACL reconstruction with a soft tissue graft and the ACL transected condition (ACLX). In the ACLX group and after ACL reconstruction with either the electrospun scaffold or soft tissue graft, pressure sensors were inserted under the menisci. Loads up to 890 N were applied at various flexion angles. The scaffold performed the best at restoring contact mechanics in the medial hemijoint to that of the native ACL. The scaffold was good at maintaining a medial-lateral balance of pressures as in the native joint whereas the ACLX shifted pressure off the lateral and on to the medial hemijoint. While the ACL scaffold didn’t restore mechanics to that of the native condition, it improved contact mechanics compared to the standard graft replacement and ACLX condition.


  • Hypoxia mimicking hydrogels to regulate the fate of transplanted stem cells

    by Binulal N. Sathy, Andrew Daly, Tomas Gonzalez-Fernandez, Dinorath Olvera, Grainne Cunniffe, Helen O. McCarthy, Nicholas Dunne, Oju Jeon, Eben Alsberg, Tammy L. Haut Donahue, et al.


  • Assessment of the compressive and tensile mechanical properties of materials used in the Jaipur Foot prosthesis

    by Rachel H Teater, Kristine M Fischenich, Benjamin B Wheatley, Lisa Abrams, Sheryl A Sorby, Harlal Singh Mali, Anil Jain, Tammy L Haut Donahue

    Designed by Dr. Sethi, the Jaipur Foot prosthesis is ideally suited for amputees in developing countries as it utilizes locally sourced, biodegradable, inexpensive materials and is focused on affordability and functionality. To date, however, no data have been reported on the material properties of the foot components. The goal of this work was to evaluate mechanical properties of the Jaipur Foot components to guide foot design and manufacturing and reduce weight. Experimental. Mechanical testing was conducted on two types of woods (ardu and cheed), microcellular rubber, tire cord, cushion compound, tread compound, and skin-colored rubber. Each material was subjected to testing in either tension or compression based on its location and function in the foot. Samples were tested before and after vulcanization. Two-sample t-tests were used to assess statistical differences. Cheed compressed perpendicular to the grain had a significantly higher modulus of elasticity than ardu (p < 0.05); however, cheed had a higher density. Vulcanization significantly increased the modulus of skin-colored rubber, cushion compound, and tread compound (p < 0.05) and decreased the moduli of both microcellular rubber and tire cord (p < 0.05). The material property results from this study provide information for computer modeling to assess material construction on overall foot mechanics for design optimization. Ardu wood was ideal based on the desire to reduce weight, and the tire cord properties serve well to hold the foot together. With new knowledge on the material properties of the components of the Jaipur Foot, future design modifications and standardized fabrication can be realized, making the Jaipur Foot more available on a global scale.


  • Corrigendum to “Effects of degeneration on the compressive and tensile properties of human meniscus”. [J. Biomech. 48 (2015) 1407–1411]

    by Kristine M. Fischenich, Jackson Lewis, Kirk A. Kindsfater, Travis S. Bailey, Tammy L. Haut Donahue

  • Epidemiological study of failures of the Jaipur Foot

    by Ian Huber, Kristine M. Fischenich, Jakob Wolynski, Brent Niese, Rachel Teater, Harlal Singh Mali, Anil Kumar Jain, Sheryl Sorby, Lisa Abrams, Tammy L. Haut Donahue

    Objective: The purpose of this study was to examine effects of usage and demographics on damage to the Jaipur Foot prosthesis as well as the epidemiology and etiology of amputations performed at Santokba Durlabjhi Memorial Hospital (SDMH) in Jaipur, India. Design: Total time spent standing, total time spent wearing and total distance walked were compared against severity and location of damage to the prosthesis. Time between initial fitting and follow-up visit for damaged prosthetic was also considered in this analysis. A novel damage severity scale based on prosthesis functionality is presented along with a damage location legend. Results: Patients from 10 different states and two territories throughout India were included in the study. No main effects were found to be statistically significant in predicting severity or location of damage. Only the interaction between a patient’s total time spent standing and their total time spent wearing the prosthesis as well as the interaction between a patient’s total time spent standing and total distance walked was significant in predicting location of damage to the Jaipur Foot (p = .0327, p = .0278, respectively). Conclusions: The lack of significant usage factor effect on damage severity or location could support previous findings that lack standardization in materials and manufacturing processes, which is the major drawback of the Jaipur Foot.


  • Open Access

    Hierarchically Structured Electrospun Scaffolds with Chemically Conjugated Growth Factor for Ligament Tissue Engineering

    by Hannah M. Pauly, Binulal N. Sathy, Dinorath Olvera, Helen O. McCarthy, Daniel J. Kelly, Ketul C. Popat, Nicholas J. Dunne, Tammy Lynn Haut Donahue

    The anterior cruciate ligament (ACL) of the knee is vital for proper joint function and is commonly ruptured during sports injuries or car accidents. Due to a lack of intrinsic healing capacity and drawbacks with allografts and autografts, there is a need for a tissue-engineered ACL replacement. Our group has previously used aligned sheets of electrospun polycaprolactone nanofibers to develop solid cylindrical bundles of longitudinally aligned nanofibers. We have shown that these nanofiber bundles support cell proliferation and elongation and the hierarchical structure and material properties are similar to the native human ACL. It is possible to combine multiple nanofiber bundles to create a scaffold that attempts to mimic the macroscale structure of the ACL. The goal of this work was to develop a hierarchical bioactive scaffold for ligament tissue engineering using connective tissue growth factor (CTGF)-conjugated nanofiber bundles and evaluate the behavior of mesenchymal stem cells (MSCs) on these scaffolds in vitro and in vivo. CTGF was immobilized onto the surface of individual nanofiber bundles or scaffolds consisting of multiple nanofiber bundles. The conjugation efficiency and the release of conjugated CTGF were assessed using X-ray photoelectron spectroscopy, assays, and immunofluorescence staining. Scaffolds were seeded with MSCs and maintained in vitro for 7 days (individual nanofiber bundles), in vitro for 21 days (scaled-up scaffolds of 20 nanofiber bundles), or in vivo for 6 weeks (small scaffolds of 4 nanofiber bundles), and ligament-specific tissue formation was assessed in comparison to non-CTGF-conjugated control scaffolds. Results showed that CTGF conjugation encouraged cell proliferation and ligament-specific tissue formation in vitro and in vivo. The results suggest that hierarchical electrospun nanofiber bundles conjugated with CTGF are a scalable and bioactive scaffold for ACL tissue engineering.


  • Dynamic compression of human and ovine meniscal tissue compared with a potential thermoplastic elastomer hydrogel replacement

    by Kristine M. Fischenich, Katie Boncella, Jackson T. Lewis, Travis S. Bailey, Tammy L. Haut Donahue

    Understanding how human meniscal tissue responds to loading regimes mimetic of daily life as well as how it compares to larger animal models is critical in the development of a functionally accurate synthetic surrogate. Seven human and eight ovine cadaveric meniscal specimens were regionally sectioned into cylinders 5 mm in diameter and 3 mm thick along with 10 polystyrene‐b‐polyethylene oxide block copolymer‐based thermoplastic elastomer (TPE) hydrogels. Samples were compressed to 12% strain at 1 Hz for 5000 cycles, unloaded for 24 h, and then retested. No differences were found within each group between test one and test two. Human and ovine tissue exhibited no regional dependency (p < 0.05). Human samples relaxed quicker than ovine tissue or the TPE hydrogel with modulus values at cycle 50 not significantly different from cycle 5000. Ovine menisci were found to be similar to human menisci in relaxation profile but had significantly higher modulus values (3.44 MPa instantaneous and 0.61 MPa after 5000 cycles compared with 1.97 and 0.11 MPa found for human tissue) and significantly different power law fit coefficients. The TPE hydrogel had an initial modulus of 0.58 MPa and experienced less than a 20% total relaxation over the 5000. Significant differences in the magnitude of compressive modulus between human and ovine menisci were observed, however the relaxation profiles were similar. Although statistically different than the native tissues, modulus values of the TPE hydrogel material were similar to those of the human and ovine menisci, making it a material worth further investigation for use as a synthetic replacement. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 2722–2728, 2017.


  • Open Access

    Early Osteoarthritis After Untreated Anterior Meniscal Root Tears: An In Vivo Animal Study

    by Brett D. Steineman, Robert F. LaPrade, Kelly S. Santangelo, Brent T. Warner, Laurie R. Goodrich, Tammy L. Haut Donahue

    Background: Meniscal root tears cause menisci and their insertions to inadequately distribute loads and potentially leave underlying articular cartilage unprotected. Untreated meniscal root tears are becoming increasingly recognized to induce joint degradation; however, little information is known about anterior meniscal root tears and how they affect joint tissue. Purpose: To observe the early degenerative changes within the synovial fluid, menisci, tibial articular cartilage, and subchondral bone after arthroscopic creation of untreated anterior meniscal root tears. Study Design: Controlled laboratory study. Methods: Anterolateral meniscal root tears were created in 1 knee joint of 5 adult Flemish Giant rabbits, and anteromedial meniscal root tears were created in 4 additional rabbits. The contralateral limbs were used as nonoperated controls. The animals were euthanized at 8 weeks postoperatively; synovial fluid was aspirated, and tissue samples of menisci and tibial articular cartilage were collected and processed for multiple analyses to detect signs of early degeneration. Results: Significant changes were found within the synovial fluid, meniscal tissue, and tibial subchondral bone of the knees with anterior meniscal root tears when compared with controls. There were no significant changes identified in the tibial articular cartilage when comparing the tear groups with controls. Conclusion: This study demonstrated early degenerative changes within the synovial fluid, menisci, and tibial subchondral bone when leaving anterior meniscal root tears untreated for 8 weeks. The results suggest that meniscal tissue presents measurable, degenerative changes prior to changes within the articular cartilage after anterior meniscal root tears. Anterior destabilization of the meniscus arthroscopically may lead to measurable degenerative changes and be useful for future in vivo natural history and animal repair studies. Clinical Relevance: The present study is the first to investigate various tissue changes after anterior meniscal root tears of both the medial and lateral menisci. The results from this study suggest that degenerative changes occur within the synovial fluid, meniscus, and tibial subchondral bone prior to any measurable changes to the tibial articular cartilage. Further studies should expand on this study to evaluate how these components continue to progress when left untreated for long periods.