Dmitry S. Klyachko
Research Subjects
Research Interests
Dmitry S. Klyachko has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Serafima B. Sugarova
Saint Petersburg Research Institute of Ear, Throat, Nose and Speech
14 shared publications - Denis D. Kaliapin
St. Petersburg Research Institute of Ear, Throat, Nose and Speech
7 shared publications - Viktoriia A. Tanaschishina
Saint-Petersburg Research Institute of Ear, Throat, Nose and Speech the Ministry of Health Russian Federation
5 shared publications - Vladimir V. Dvoryanchikov
Saint Petersburg Research Institute of Ear, Throat, Nose and Speech
5 shared publications - Aleksandr V. Pashkov
Research Institute of Pediatrics and Children’s Health in Petrovsky National Research Centre of Surgery; Central State Medical Academy
4 shared publications - Andrei S. Lilenko
Saint Petersburg Research Institute of Ear, Throat, Nose and Speech
4 shared publications
Latest Publications
- 10 November 2025
- Published by Media Sphere Publishing Group in Russian Bulletin of Otorhinolaryngology
- Vol. 90 (5) , 9-12
The clinical use of impedance field telemetry heat maps at the rehabilitation stage of cochlear implantation
The article is devoted to the study of impedance field telemetry at the rehabilitation stage of cochlear implantation. The technology was developed in 2012 as an additional protocol to implant telemetry. Its task is to identify defects in the cochlear implant electrode array insertion during surgery. Objective. To determine a practical benefit from using this technology at the rehabilitation stage of cochlear implantation. Material and methods. Cases of 100 patients from 10 months to 74 years old, Δ=17±8.6 years, who underwent a rehabilitation course or the speech processor exchange at the St. Petersburg Research Institute of ENT in 2025 were prospectively studied. All patients had a MedEl cochlear implant with a straight type of electrode array: standard (n=69), flex-soft (n=31). Objectives of the study: to assess the correspondence between the standard implant telemetry and the impedance field telemetry heat maps; to identify additional information when analyzing heat maps; to determine indications for using the technology at the rehabilitation stage of cochlear implantation. Results: In all (100%) cases, impedance field telemetry heat maps served as a convenient graphical representation of the data, an additional opportunity appeared to evaluate each of the system contacts for all possible stimulation options. In 18 patients (18%), additional information had clinical significance and influenced the specialist’s decision-making, which is illustrated by clinical examples of three patients. Conclusions: Impedance field telemetry is an informative and convenient diagnostic method, both intraoperatively and at the rehabilitation stage. Heat maps do not completely replace classical telemetry, but they help to obtain additional information, which is of clinical significance in some cases. The method should be used in conjunction with implant telemetry in complex or ambiguous situations.
- 10 November 2025
- Published by Media Sphere Publishing Group in Russian Bulletin of Otorhinolaryngology
- Vol. 90 (5) , 9-12
The clinical use of impedance field telemetry heat maps at the rehabilitation stage of cochlear implantation
The article is devoted to the study of impedance field telemetry at the rehabilitation stage of cochlear implantation. The technology was developed in 2012 as an additional protocol to implant telemetry. Its task is to identify defects in the cochlear implant electrode array insertion during surgery. Objective. To determine a practical benefit from using this technology at the rehabilitation stage of cochlear implantation. Material and methods. Cases of 100 patients from 10 months to 74 years old, Δ=17±8.6 years, who underwent a rehabilitation course or the speech processor exchange at the St. Petersburg Research Institute of ENT in 2025 were prospectively studied. All patients had a MedEl cochlear implant with a straight type of electrode array: standard (n=69), flex-soft (n=31). Objectives of the study: to assess the correspondence between the standard implant telemetry and the impedance field telemetry heat maps; to identify additional information when analyzing heat maps; to determine indications for using the technology at the rehabilitation stage of cochlear implantation. Results: In all (100%) cases, impedance field telemetry heat maps served as a convenient graphical representation of the data, an additional opportunity appeared to evaluate each of the system contacts for all possible stimulation options. In 18 patients (18%), additional information had clinical significance and influenced the specialist’s decision-making, which is illustrated by clinical examples of three patients. Conclusions: Impedance field telemetry is an informative and convenient diagnostic method, both intraoperatively and at the rehabilitation stage. Heat maps do not completely replace classical telemetry, but they help to obtain additional information, which is of clinical significance in some cases. The method should be used in conjunction with implant telemetry in complex or ambiguous situations.
- 3 September 2025
- Published by Media Sphere Publishing Group in Russian Bulletin of Otorhinolaryngology
- Vol. 90 (4) , 11-18
Candidacy and rehabilitation of adolescents during sequential bilateral cochlear implantation with a long-term interval between surgeries
An algorithm has been developed to accompany adolescents at the stages of determining indications and postoperative rehabilitation for sequential bilateral cochlear implantation with a long interval between operations, minimizing the risk of failure to use a cochlear implant (CI) in the second ear (CI2) and ensuring its effective use. The algorithm includes: 1) 2 groups of factors influencing the results of CI2 — unchangeable (medical and biological) and influenceable (psychological and pedagogical — teenager’s motivation for CI2, adequate expectations of the results, regular auditory training with CI2); 2) 4 stages of adaptation to stimulation with CI2 and use of CI1 with CI2; 3) audiological, physiological, psychological, auditory training components of the adaptation process to CI2. The study involved 26 prelingually deaf adolescents aged 10-16 years (mean 13.5±3.1 years) implanted in one up to 3 years, who did not use a hearing aid in the second ear after the surgery. The interval after the first surgery was 8-15 years (9.3±4.4 years). 2 candidates were denied implantation in the 2nd ear because of the low effectiveness of CI1 due to additional severe impairments. In two patients, the decision to perform CI2 was postponed due to the lack of motivation. After 6 months with regular auditory training with CI2 and CI1+CI2 with the participation of parents, all 22 adolescents constantly used both CIs and noted the advantage of use of CI1+CI2. The level of auditory perception with CI2 approached the level of perception with CI1 according to the CAP scale in 64% of adolescents. In 8 patients the auditory perception indices with CI2 were lower than with CI1, primarily due to underdevelopment of phonemic hearing.
- 3 September 2025
- Published by Media Sphere Publishing Group in Russian Bulletin of Otorhinolaryngology
- Vol. 90 (4) , 11-18
Candidacy and rehabilitation of adolescents during sequential bilateral cochlear implantation with a long-term interval between surgeries
An algorithm has been developed to accompany adolescents at the stages of determining indications and postoperative rehabilitation for sequential bilateral cochlear implantation with a long interval between operations, minimizing the risk of failure to use a cochlear implant (CI) in the second ear (CI2) and ensuring its effective use. The algorithm includes: 1) 2 groups of factors influencing the results of CI2 — unchangeable (medical and biological) and influenceable (psychological and pedagogical — teenager’s motivation for CI2, adequate expectations of the results, regular auditory training with CI2); 2) 4 stages of adaptation to stimulation with CI2 and use of CI1 with CI2; 3) audiological, physiological, psychological, auditory training components of the adaptation process to CI2. The study involved 26 prelingually deaf adolescents aged 10-16 years (mean 13.5±3.1 years) implanted in one up to 3 years, who did not use a hearing aid in the second ear after the surgery. The interval after the first surgery was 8-15 years (9.3±4.4 years). 2 candidates were denied implantation in the 2nd ear because of the low effectiveness of CI1 due to additional severe impairments. In two patients, the decision to perform CI2 was postponed due to the lack of motivation. After 6 months with regular auditory training with CI2 and CI1+CI2 with the participation of parents, all 22 adolescents constantly used both CIs and noted the advantage of use of CI1+CI2. The level of auditory perception with CI2 approached the level of perception with CI1 according to the CAP scale in 64% of adolescents. In 8 patients the auditory perception indices with CI2 were lower than with CI1, primarily due to underdevelopment of phonemic hearing.
- 1 January 2025
- Published by LLC Polyforum Group in Russian Otorhinolaryngology
- Vol. 24 (4)
Binaural cochlear implantation in adults: our experience
Currently, cochlear implantation allows for successful rehabilitation of individuals with profound bilateral chronic sensorineural hearing loss and deafness. Rehabilitation of adult patients plays a crucial role in their integration into the socioeconomic environment and the restoration of work capacity. As a result, there is an increasing number of adult patients undergoing binaural cochlear implantation. The two devices help recreate the natural mechanism of sound perception. Consequently, this provides numerous benefits for patients, such as improved speech intelligibility, the ability to distinguish sounds in noisy environments and in the presence of several speakers, determination of the direction of the sound source. All this eliminates the need to make additional efforts to understand surrounding sounds and makes listening to speech more comfortable. Methods and patients. Given the relevance of this issue, a study was conducted at the Saint Petersburg Research Institute of Ear, Nose, Throat, and Speech among 15 binaurally implanted patients over the age of 18. Results. In 53% of cases, speech intelligibility of 75±10% was achieved in a closed-set speech recognition test on the “new ear” during the first rehabilitation. During a repeated course of auditory-verbal rehabilitation, 85±12% speech intelligibility was achieved in 53% of cases during monaural testing of the «new» ear. In 87% of cases, speech audiometry in a free sound field showed 100% speech intelligibility in binaural testing. Patients reported improved sound perception, the ability to localize the sound source, and advantages of using two speech processors in noisy environments. Conclusion. Binaural cochlear implantation is a highly promising and modern rehabilitation solution for adult patients with profound bilateral chronic sensorineural hearing loss, in cases where hearing aids are ineffective, and for those with deafness while maintaining the cortical plasticity of the brain.
- 1 January 2025
- Published by LLC Polyforum Group in Russian Otorhinolaryngology
- Vol. 24 (4)
Binaural cochlear implantation in adults: our experience
Currently, cochlear implantation allows for successful rehabilitation of individuals with profound bilateral chronic sensorineural hearing loss and deafness. Rehabilitation of adult patients plays a crucial role in their integration into the socioeconomic environment and the restoration of work capacity. As a result, there is an increasing number of adult patients undergoing binaural cochlear implantation. The two devices help recreate the natural mechanism of sound perception. Consequently, this provides numerous benefits for patients, such as improved speech intelligibility, the ability to distinguish sounds in noisy environments and in the presence of several speakers, determination of the direction of the sound source. All this eliminates the need to make additional efforts to understand surrounding sounds and makes listening to speech more comfortable. Methods and patients. Given the relevance of this issue, a study was conducted at the Saint Petersburg Research Institute of Ear, Nose, Throat, and Speech among 15 binaurally implanted patients over the age of 18. Results. In 53% of cases, speech intelligibility of 75±10% was achieved in a closed-set speech recognition test on the “new ear” during the first rehabilitation. During a repeated course of auditory-verbal rehabilitation, 85±12% speech intelligibility was achieved in 53% of cases during monaural testing of the «new» ear. In 87% of cases, speech audiometry in a free sound field showed 100% speech intelligibility in binaural testing. Patients reported improved sound perception, the ability to localize the sound source, and advantages of using two speech processors in noisy environments. Conclusion. Binaural cochlear implantation is a highly promising and modern rehabilitation solution for adult patients with profound bilateral chronic sensorineural hearing loss, in cases where hearing aids are ineffective, and for those with deafness while maintaining the cortical plasticity of the brain.
- Open Access
- 18 May 2024
- Published by Consilium Medicum in Consilium Medicum
- Vol. 26 (3) , 172-176
A clinical case of a patient with subtotal ossification of the cochlea: results of cochlear implantation using neuroimaging methods to control dynamics
Background. Nowadays cochlear implantation (CI) is a globally recognized method of rehabilitation of people with deafness, which allows not only to improve the quality of life of the patient, but also to integrate them into the hearing environment. Ossification of the labyrinth is one of the most challenging problems faced by a surgeon during a CI. Patients with cochlear ossification have a set of problems that an audiologist encounters. Among them: duration of deafness; previous difficulties with hearing aids due to lack of effectiveness and severity of discomfort when wearing a hearing aid; severity of damage to the microstructures of the ear, leading to the need to use high levels; potential incomplete insertion of an electrode or insertion of an electrode through a cochleostomy; the occurrence of non-auditory sensations in the form of stimulation of the facial nerve; Functional neuroimaging can provide insight into the neurobiological factors that contribute to differences in individual hearing outcomes after cochlear implantation. To date, measuring neural activity in the auditory cortex of cochlear implant users has been a difficult task, primarily because the use of traditional neuroimaging techniques is limited. Functional near-infrared spectroscopy (fNIRS) is a new technology that offers advantages to this group of patients because it is non-invasive, compatible with CI devices and is not subject to electrical interference. The knowledge gained using this technique makes it possible to objectify the quality of auditory-speech rehabilitation of patients by fixing the activity of the cerebral cortex. Aim. To describe a clinical case of a patient with subtotal ossification of the cochlea with an assessment of auditory-speech rehabilitation using neuroimaging techniques. Materials and methods. In November 2022, patient M. was admitted to Saint-Petersburg Research Institute of Ear, Throat, Nose and Speech with complaints of hearing loss up to deafness, tinnitus, discomfort when wearing hearing aids. It was known from the anamnesis that the patient had suffered from purulent meningitis of unknown etiology at the age of 5. The patient was monitored by sign-language specialists for a long time, and from the age of 15 she had hearing aids on both ears without significant effect. In 2021, she noted a complete loss of the effectiveness of hearing aids, and therefore decided to undergo an examination for the CI. The patient's speech was represented by complex sentences with agrammatism, speech perception was mainly performed visually by lip reading. CT scans of the temporal bones from 27.03.2022 revealed signs of subtotal ossification of the labyrinth structures on both sides with unreliable signs of partial patency of the spiral canal of the cochlea on the right. Due to the high risks of incomplete insertion of the electrode, up to the impossibility of its introduction, the decision on surgical treatment was made by a concilium consisting of 2 otosurgeons, an anesthesiologist, an audiologist and a neurologist. Intraoperatively, it was decided to use a short straight electrode with a length of 11 mm. Good auditory-speech results were obtained, the objectivity of the data obtained was confirmed by the method of near-infrared functional spectroscopy. Conclusion. The fNIRS technique made it possible to obtain an objective picture of the reaction of the temporal lobe cortex specifically to sound stimulation in a patient with RP without the use of invasive or radiological research methods, which in some cases may have an application error. We believe that the use of this technique is promising in patients with profound hearing loss before and after cochlear implantation.
- 18 May 2024
- Published by Consilium Medicum in Consilium Medicum
- Vol. 26 (3) , 172-176
Open AccessA clinical case of a patient with subtotal ossification of the cochlea: results of cochlear implantation using neuroimaging methods to control dynamics
Background. Nowadays cochlear implantation (CI) is a globally recognized method of rehabilitation of people with deafness, which allows not only to improve the quality of life of the patient, but also to integrate them into the hearing environment. Ossification of the labyrinth is one of the most challenging problems faced by a surgeon during a CI. Patients with cochlear ossification have a set of problems that an audiologist encounters. Among them: duration of deafness; previous difficulties with hearing aids due to lack of effectiveness and severity of discomfort when wearing a hearing aid; severity of damage to the microstructures of the ear, leading to the need to use high levels; potential incomplete insertion of an electrode or insertion of an electrode through a cochleostomy; the occurrence of non-auditory sensations in the form of stimulation of the facial nerve; Functional neuroimaging can provide insight into the neurobiological factors that contribute to differences in individual hearing outcomes after cochlear implantation. To date, measuring neural activity in the auditory cortex of cochlear implant users has been a difficult task, primarily because the use of traditional neuroimaging techniques is limited. Functional near-infrared spectroscopy (fNIRS) is a new technology that offers advantages to this group of patients because it is non-invasive, compatible with CI devices and is not subject to electrical interference. The knowledge gained using this technique makes it possible to objectify the quality of auditory-speech rehabilitation of patients by fixing the activity of the cerebral cortex. Aim. To describe a clinical case of a patient with subtotal ossification of the cochlea with an assessment of auditory-speech rehabilitation using neuroimaging techniques. Materials and methods. In November 2022, patient M. was admitted to Saint-Petersburg Research Institute of Ear, Throat, Nose and Speech with complaints of hearing loss up to deafness, tinnitus, discomfort when wearing hearing aids. It was known from the anamnesis that the patient had suffered from purulent meningitis of unknown etiology at the age of 5. The patient was monitored by sign-language specialists for a long time, and from the age of 15 she had hearing aids on both ears without significant effect. In 2021, she noted a complete loss of the effectiveness of hearing aids, and therefore decided to undergo an examination for the CI. The patient's speech was represented by complex sentences with agrammatism, speech perception was mainly performed visually by lip reading. CT scans of the temporal bones from 27.03.2022 revealed signs of subtotal ossification of the labyrinth structures on both sides with unreliable signs of partial patency of the spiral canal of the cochlea on the right. Due to the high risks of incomplete insertion of the electrode, up to the impossibility of its introduction, the decision on surgical treatment was made by a concilium consisting of 2 otosurgeons, an anesthesiologist, an audiologist and a neurologist. Intraoperatively, it was decided to use a short straight electrode with a length of 11 mm. Good auditory-speech results were obtained, the objectivity of the data obtained was confirmed by the method of near-infrared functional spectroscopy. Conclusion. The fNIRS technique made it possible to obtain an objective picture of the reaction of the temporal lobe cortex specifically to sound stimulation in a patient with RP without the use of invasive or radiological research methods, which in some cases may have an application error. We believe that the use of this technique is promising in patients with profound hearing loss before and after cochlear implantation.
- 23 April 2024
- Published by Media Sphere Publishing Group in Russian Bulletin of Otorhinolaryngology
- Vol. 89 (6) , 4-9
Audiological aspects of rehabilitation after cochlear implantation in patients with inner ear malformations
The article is devoted to the problem of the rehabilitation stage of cochlear implantation in patients with inner ear abnormalities. It provides a detailed analysis of the audiological characteristics of such patients and draws conclusions about approaches to interpreting diagnostic data and speech processors fitting. Material and methods. The track records of 80 patients with abnormalities of the inner ear development were retrospectively studied, of which 10 had abnormal structure of the auditory nerve. At the surgical and rehabilitation stages, patients underwent analysis of the results of implant telemetry, neural response telemetry, speech processor fitting maps, and the results of subjective audiological testing. The results were compared with those of 50 patients (control group) with normal inner ear anatomy and congenital deafness etiology. Results. The resistance figures of the electrode circuit in patients with abnormalities of the inner ear and normal anatomy did not differ statistically significantly (T=0.86, p>0.05). The ability to register the eCAP turned out to be significantly lower in patients with cochlear malformations and had a pattern with the degree of pathological development of the organ (T=10.2; p<0.05). The distinctive features of the fitting maps of speech processors in different groups were also revealed, as well as the results of audiological testing. Conclusions. Patients with abnormalities in the development of the inner ear have distinctive electrophysiological characteristics that are important during the rehabilitation stage of cochlear transplantation. When configuring speech processors, it makes sense to resort to using CIS coding strategies, reducing the dynamic range by increasing the minimum stimulation threshold, and increasing compression
- 23 April 2024
- Published by Media Sphere Publishing Group in Russian Bulletin of Otorhinolaryngology
- Vol. 89 (6) , 4-9
Audiological aspects of rehabilitation after cochlear implantation in patients with inner ear malformations
The article is devoted to the problem of the rehabilitation stage of cochlear implantation in patients with inner ear abnormalities. It provides a detailed analysis of the audiological characteristics of such patients and draws conclusions about approaches to interpreting diagnostic data and speech processors fitting. Material and methods. The track records of 80 patients with abnormalities of the inner ear development were retrospectively studied, of which 10 had abnormal structure of the auditory nerve. At the surgical and rehabilitation stages, patients underwent analysis of the results of implant telemetry, neural response telemetry, speech processor fitting maps, and the results of subjective audiological testing. The results were compared with those of 50 patients (control group) with normal inner ear anatomy and congenital deafness etiology. Results. The resistance figures of the electrode circuit in patients with abnormalities of the inner ear and normal anatomy did not differ statistically significantly (T=0.86, p>0.05). The ability to register the eCAP turned out to be significantly lower in patients with cochlear malformations and had a pattern with the degree of pathological development of the organ (T=10.2; p<0.05). The distinctive features of the fitting maps of speech processors in different groups were also revealed, as well as the results of audiological testing. Conclusions. Patients with abnormalities in the development of the inner ear have distinctive electrophysiological characteristics that are important during the rehabilitation stage of cochlear transplantation. When configuring speech processors, it makes sense to resort to using CIS coding strategies, reducing the dynamic range by increasing the minimum stimulation threshold, and increasing compression
- 1 January 2024
- Published by LLC Polyforum Group in Russian Otorhinolaryngology
- Vol. 23 (3)
Enlarged vestibular aqueduct as cause of manifestation of hearing loss in adolescents and adults
The malformations in the development of the inner ear often cause congenital sensorineural hearing loss; however, the descriptions of clinical cases of age-related hearing loss due to temporal bone malformations have been appearing in foreign and domestic scientific literature more frequently over the past few years. The enlarged vestibular aqueduct syndrome is of most interest from the point of view of inner ear malformations that lead to late manifestation of hearing loss. This syndrome poses certain difficulties for diagnosis and choice of treatment strategy. The article presents information on the enlarged vestibular aqueduct syndrome clinical manifestations, modern diagnosis methods, treatment and rehabilitation options available for adult patients based on the summarization of contemporary scientific works and on the examples of clinical cases from personal work experience.
- 1 January 2024
- Published by LLC Polyforum Group in Russian Otorhinolaryngology
- Vol. 23 (3)
Enlarged vestibular aqueduct as cause of manifestation of hearing loss in adolescents and adults
The malformations in the development of the inner ear often cause congenital sensorineural hearing loss; however, the descriptions of clinical cases of age-related hearing loss due to temporal bone malformations have been appearing in foreign and domestic scientific literature more frequently over the past few years. The enlarged vestibular aqueduct syndrome is of most interest from the point of view of inner ear malformations that lead to late manifestation of hearing loss. This syndrome poses certain difficulties for diagnosis and choice of treatment strategy. The article presents information on the enlarged vestibular aqueduct syndrome clinical manifestations, modern diagnosis methods, treatment and rehabilitation options available for adult patients based on the summarization of contemporary scientific works and on the examples of clinical cases from personal work experience.
- Open Access
- 1 January 2024
- Published by Herzen State Pedagogical University of Russia
- Vol. 5 (4) , 357–364
Regeneration of first auditory neuron action potential by a weak magnetic field in patients with hearing loss
Sensorineural hearing loss can result not only from damage to the auditory apparatus or central auditory pathways but also from cellular dysfunction at the neuronal level, particularly in the first auditory neuron. A key issue may involve the absence or inadequate generation of the action potential (AP) in this neuron. To address this, we have developed a device for the non-invasive application of a weak (less than 300 μT) alternating magnetic field, designed to activate voltage-gated Na+, K+, and Ca2+ ion channels in the first auditory neuron. The sequential opening of these channels induces membrane depolarization, generating an AP and restoring neuronal conductivity. Improvement in hearing was observed in patients with neural hearing loss (degree III and IV) who use hearing aids. The exposure time to the alternating magnetic field varied depending on the diagnosis and the patient’s age. This article reports a hearing improvement of approximately 10 dB in an adult patient following a single 20-minute session and a 20–40 dB improvement in children after a 10-minute session. However, the new sensitivity threshold achieved through electromagnetic stimulation remains unstable and requires further treatment sessions along with appropriate acoustic support. Нейросенсорная тугоухость может быть вызвана не только классическими поражениями звуковоспринимающего аппарата или центральных отделов слухового анализатора, но и проблемами на клеточном уровне в нейронах, в частности, первом слуховом нейроне. Такой проблемой может быть отсутствие или недостаточность величины потенциала действия (ПД) на нем. Разработана и создана аппаратура по неинвазивному применению слабого (менее 300 мкТл) переменного магнитного поля для воздействия на этот нейрон с целью активации потенциалзависимых Na+, K+ и Ca2+ ионных каналов. Последовательное открытие каналов приводит к деполяризации мембраны первого слухового нейрона, следствием чего является генерирование ПД на нем и восстановление его проводимости. Получен эффект улучшения слуха у испытуемых пациентов с нейрональной тугоухостью III и IV степени, использующих слуховые аппараты. Время воздействия переменного магнитного поля зависит от поставленного диагноза и возраста. Приведены и обсуждаются примеры улучшения слуха у взрослого пациента за один сеанс — 20 минут, улучшение составляло ~10 дб, тогда как для детей 10-минутный сеанс давал улучшение ~20‒40 дб. Полученный после применения электромагнитной стимуляции новый порог чувствительности достаточно нестабилен и требует как дополнительных процедур, так и соответствующей акустической поддержки.
- 1 January 2024
- Published by Herzen State Pedagogical University of Russia
- Vol. 5 (4) , 357–364
Open AccessRegeneration of first auditory neuron action potential by a weak magnetic field in patients with hearing loss
Sensorineural hearing loss can result not only from damage to the auditory apparatus or central auditory pathways but also from cellular dysfunction at the neuronal level, particularly in the first auditory neuron. A key issue may involve the absence or inadequate generation of the action potential (AP) in this neuron. To address this, we have developed a device for the non-invasive application of a weak (less than 300 μT) alternating magnetic field, designed to activate voltage-gated Na+, K+, and Ca2+ ion channels in the first auditory neuron. The sequential opening of these channels induces membrane depolarization, generating an AP and restoring neuronal conductivity. Improvement in hearing was observed in patients with neural hearing loss (degree III and IV) who use hearing aids. The exposure time to the alternating magnetic field varied depending on the diagnosis and the patient’s age. This article reports a hearing improvement of approximately 10 dB in an adult patient following a single 20-minute session and a 20–40 dB improvement in children after a 10-minute session. However, the new sensitivity threshold achieved through electromagnetic stimulation remains unstable and requires further treatment sessions along with appropriate acoustic support. Нейросенсорная тугоухость может быть вызвана не только классическими поражениями звуковоспринимающего аппарата или центральных отделов слухового анализатора, но и проблемами на клеточном уровне в нейронах, в частности, первом слуховом нейроне. Такой проблемой может быть отсутствие или недостаточность величины потенциала действия (ПД) на нем. Разработана и создана аппаратура по неинвазивному применению слабого (менее 300 мкТл) переменного магнитного поля для воздействия на этот нейрон с целью активации потенциалзависимых Na+, K+ и Ca2+ ионных каналов. Последовательное открытие каналов приводит к деполяризации мембраны первого слухового нейрона, следствием чего является генерирование ПД на нем и восстановление его проводимости. Получен эффект улучшения слуха у испытуемых пациентов с нейрональной тугоухостью III и IV степени, использующих слуховые аппараты. Время воздействия переменного магнитного поля зависит от поставленного диагноза и возраста. Приведены и обсуждаются примеры улучшения слуха у взрослого пациента за один сеанс — 20 минут, улучшение составляло ~10 дб, тогда как для детей 10-минутный сеанс давал улучшение ~20‒40 дб. Полученный после применения электромагнитной стимуляции новый порог чувствительности достаточно нестабилен и требует как дополнительных процедур, так и соответствующей акустической поддержки.
- 1 January 2024
- Published by LLC Polyforum Group in Russian Otorhinolaryngology
- Vol. 23 (1)
Possibilities and prospects of functional near-infrared spectroscopy in patients with high-tech hearing aids
One of the most notable features of auditory prosthetics at the present stage of development is the close interdisciplinary interaction of related medical, scientific, and social specialties. The solution of practical problems in audiology has long gone beyond the range of selecting a method of acoustic or electrical amplification. The priorities in decision making have increasingly shifted from purely engineering efficiency toward improving the quality of life in general. A personalized approach to choosing optimal solutions for each specific case inevitably led specialists to study the cognitive potential and neurophysiological characteristics of the patient. That is why various methods of functional neuroimaging are increasingly being introduced into the scientific and practical activities of an audiologist. Functional near infrared spectroscopy (fNIRS) is considered one of the youngest and most promising technologies. It allows us to research the metabolic activity of the cerebral cortex, which is an important source of feedback when working with sensory functions of the body. The potential of its use can vary from evaluating the effectiveness of measures already taken to solving complex controversial issues of selecting patients for high-tech treatment methods, which do not always remain regulated in methodological documents: the choice of prosthetics, the expediency of performing cochlear implantation in patients with ambiguous indications and contraindications, assessment of rehabilitation potential in neurological comorbidity, etc. In this article, we have tried to systematize and reflect the relevant aspects of the use of fNIRS for audiology patients with a description of the essence of the method, its comparison with alternative methods of functional imaging such as functional magnetic resonance imaging, electroencephalography, magnetoencephalography, positron emission tomography.
- 1 January 2024
- Published by LLC Polyforum Group in Russian Otorhinolaryngology
- Vol. 23 (1)
Possibilities and prospects of functional near-infrared spectroscopy in patients with high-tech hearing aids
One of the most notable features of auditory prosthetics at the present stage of development is the close interdisciplinary interaction of related medical, scientific, and social specialties. The solution of practical problems in audiology has long gone beyond the range of selecting a method of acoustic or electrical amplification. The priorities in decision making have increasingly shifted from purely engineering efficiency toward improving the quality of life in general. A personalized approach to choosing optimal solutions for each specific case inevitably led specialists to study the cognitive potential and neurophysiological characteristics of the patient. That is why various methods of functional neuroimaging are increasingly being introduced into the scientific and practical activities of an audiologist. Functional near infrared spectroscopy (fNIRS) is considered one of the youngest and most promising technologies. It allows us to research the metabolic activity of the cerebral cortex, which is an important source of feedback when working with sensory functions of the body. The potential of its use can vary from evaluating the effectiveness of measures already taken to solving complex controversial issues of selecting patients for high-tech treatment methods, which do not always remain regulated in methodological documents: the choice of prosthetics, the expediency of performing cochlear implantation in patients with ambiguous indications and contraindications, assessment of rehabilitation potential in neurological comorbidity, etc. In this article, we have tried to systematize and reflect the relevant aspects of the use of fNIRS for audiology patients with a description of the essence of the method, its comparison with alternative methods of functional imaging such as functional magnetic resonance imaging, electroencephalography, magnetoencephalography, positron emission tomography.
- 16 November 2023
- Published by Media Sphere Publishing Group in Russian Bulletin of Otorhinolaryngology
- Vol. 88 (5) , 19-22
The time range in sequential bilateral cochlear implantation
The article is devoted to the problems of binaural cochlear implantation, especially in patients with a long time interval between surgeries. The purpose of the study was to evaluate the effect of the time range between successive interventions in patients with binaural prosthetics using the CI system. Materials and methods: the study included 50 patients aged 10 to 14 years, divided into 3 study groups: patients with unilateral cochlear implantation (group I), patients with bilateral implantation with a less than 1 year range between operations (group II) and patients with bilateral implantation with a more than 5 year range between interventions (group III). Comparative analysis was carried out using speech audiometry in silence and noise, assessment of sound localization and questionnaires to assess the auditory dynamics and speech development. Results: Patients in groups II and III showed comparable results in speech intelligibility in noise and sound localization. At the same time, these indicators turned out to be higher than in patients of group I. Patients from all three groups did not show statistically significant differences in speech intelligibility in silence and in the level of speech development. Conclusion: a long interval (more than 5 years) after the first implantation should not be considered as a contraindication to binaural implantation.
- 16 November 2023
- Published by Media Sphere Publishing Group in Russian Bulletin of Otorhinolaryngology
- Vol. 88 (5) , 19-22
The time range in sequential bilateral cochlear implantation
The article is devoted to the problems of binaural cochlear implantation, especially in patients with a long time interval between surgeries. The purpose of the study was to evaluate the effect of the time range between successive interventions in patients with binaural prosthetics using the CI system. Materials and methods: the study included 50 patients aged 10 to 14 years, divided into 3 study groups: patients with unilateral cochlear implantation (group I), patients with bilateral implantation with a less than 1 year range between operations (group II) and patients with bilateral implantation with a more than 5 year range between interventions (group III). Comparative analysis was carried out using speech audiometry in silence and noise, assessment of sound localization and questionnaires to assess the auditory dynamics and speech development. Results: Patients in groups II and III showed comparable results in speech intelligibility in noise and sound localization. At the same time, these indicators turned out to be higher than in patients of group I. Patients from all three groups did not show statistically significant differences in speech intelligibility in silence and in the level of speech development. Conclusion: a long interval (more than 5 years) after the first implantation should not be considered as a contraindication to binaural implantation.
- Open Access
- 2 January 2023
- Published by Herzen State Pedagogical University of Russia
- Vol. 4 (4) , 475–482
Effect of weak low-frequency magnetic fields on oculomotorius muscles
The paper reports the results of the study on the influence of weak low-frequency magnetic fields on human vision. In particular, it determines the primary magnetic fields frequency ranges that cause magnetobiological reactions, i. e., individual contraction of oculomotorius muscles. The magnitude of magnetic fields did not exceed 300 μT, which makes it possible to classify such fields as safe for human health according to the current legislation. Exposure of eye motoneurons to an external alternating magnetic field causes reactions on the part of specific oculomotorius muscles that are identical to their reactions under natural motoneuron control. Neurons located at other hierarchical levels show more complex reactions in which several oculomotorius muscles take part. The study found that the frequency of oculomotorius muscles ranges from 40 to 85 Hz. Each neuron can be characterized by its ‘frequency range’ of external magnetic control. Hence, the knowledge of frequency ranges for all neurons of a particular control system not only allows the possibility of external control of such a system, but also the possibility of its diagnosis by means of external noninvasive examination. The conducted research is another contribution into weak fields magnetobiology. It aims to create alternative noninvasive technologies for practical medicine. Представлены результаты исследования влияния слабых низкочастотных магнитных полей на систему управления глазодвигательными мышцами человека. Определены первичные диапазоны частот магнитного поля, вызывающие магнитобиологические реакции в виде сокращения отдельных глазодвигательных мышц. Величина индукции используемых магнитных полей не превышала 300 мкТл, что позволяет отнести такие поля к классу безопасных для здоровья человека в соответствии с действующим законодательством. Воздействие на мотонейроны глаз внешним переменным магнитным полем вызывает со стороны конкретных глазодвигательных мышц реакции, идентичные их реакциям при естественном управлении мотонейронами. Нейроны управления, расположенные на других иерархических уровнях и вызывающие более сложные реакции, в которых принимают участие уже несколько глазодвигательных мышц, в данном исследовании не рассматривали. Получен диапазон частот для глазодвигательных мышц от 40 до 85 Гц. Поскольку каждый такой мотонейрон можно характеризовать своим «частотным диапазоном» внешнего магнитного управления, то знание частотных диапазонов всех мотонейронов конкретной системы управления позволяет говорить о возможности частичного внешнего управления такой системой. Проведенные исследования являются продолжением работ в области магнитобиологии слабых полей и направлены на создание современных альтернативных неинвазивных технологий в области практической медицины.
- 2 January 2023
- Published by Herzen State Pedagogical University of Russia
- Vol. 4 (4) , 475–482
Open AccessEffect of weak low-frequency magnetic fields on oculomotorius muscles
The paper reports the results of the study on the influence of weak low-frequency magnetic fields on human vision. In particular, it determines the primary magnetic fields frequency ranges that cause magnetobiological reactions, i. e., individual contraction of oculomotorius muscles. The magnitude of magnetic fields did not exceed 300 μT, which makes it possible to classify such fields as safe for human health according to the current legislation. Exposure of eye motoneurons to an external alternating magnetic field causes reactions on the part of specific oculomotorius muscles that are identical to their reactions under natural motoneuron control. Neurons located at other hierarchical levels show more complex reactions in which several oculomotorius muscles take part. The study found that the frequency of oculomotorius muscles ranges from 40 to 85 Hz. Each neuron can be characterized by its ‘frequency range’ of external magnetic control. Hence, the knowledge of frequency ranges for all neurons of a particular control system not only allows the possibility of external control of such a system, but also the possibility of its diagnosis by means of external noninvasive examination. The conducted research is another contribution into weak fields magnetobiology. It aims to create alternative noninvasive technologies for practical medicine. Представлены результаты исследования влияния слабых низкочастотных магнитных полей на систему управления глазодвигательными мышцами человека. Определены первичные диапазоны частот магнитного поля, вызывающие магнитобиологические реакции в виде сокращения отдельных глазодвигательных мышц. Величина индукции используемых магнитных полей не превышала 300 мкТл, что позволяет отнести такие поля к классу безопасных для здоровья человека в соответствии с действующим законодательством. Воздействие на мотонейроны глаз внешним переменным магнитным полем вызывает со стороны конкретных глазодвигательных мышц реакции, идентичные их реакциям при естественном управлении мотонейронами. Нейроны управления, расположенные на других иерархических уровнях и вызывающие более сложные реакции, в которых принимают участие уже несколько глазодвигательных мышц, в данном исследовании не рассматривали. Получен диапазон частот для глазодвигательных мышц от 40 до 85 Гц. Поскольку каждый такой мотонейрон можно характеризовать своим «частотным диапазоном» внешнего магнитного управления, то знание частотных диапазонов всех мотонейронов конкретной системы управления позволяет говорить о возможности частичного внешнего управления такой системой. Проведенные исследования являются продолжением работ в области магнитобиологии слабых полей и направлены на создание современных альтернативных неинвазивных технологий в области практической медицины.