Peter William McCarthy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Peter William McCarthy has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Zhuofu Liu
The Higher Educational Key Laboratory for Measuring & Control Technology and Instrumentations of Heilongjiang Province, Harbin University of Science and Technology, Harbin 150080, China
9 shared publications - Vincenzo Cascioli
Murdoch University Chiropractic Clinic, Murdoch University, Murdoch 6150, Australia
8 shared publications - Gaohan Li
The Higher Educational Key Laboratory for Measuring and Control Technology and Instrumentations of Heilongjiang Province, Harbin University of Science and Technology, Harbin 150080, China
3 shared publications - Andrew I. Heusch
University of South Wales, United Kingdom
2 shared publications - Kent Stuber
Parker University USA
2 shared publications - Mark Langweiler
Faculty of Life Sciences and Education, University of South Wales, Treforest, Wales, UK
2 shared publications
Latest Publications
- Open Access
Privacy-Preserving Head Pose Estimation System for Measuring Cervical Range of Motion
Cervical range of motion (CROM) has been used in research and clinically for assessing cervical health. Gold-standard goniometers tend to be cumbersome. However, Inertial Measurement Units (IMUs) or vision-based alternatives demand frequent calibration and/or costly hardware; moreover, the subject is aware of being measured and there is a risk of breaching privacy. In response, we have developed a non-contact HPNet system for head pose estimation (HPE) that can use a rear-facing camera to quantify CROM accurately. A Re-parameterized Visual Geometry Group (RepVGG)-D2se model is employed as the backbone of the network, and a Spatial Feature Enhancement (SCFE) module is incorporated to improve feature extraction. HPNet was evaluated on the large-scale Carnegie Mellon University (CMU) Panoptic dataset, achieving a mean absolute error (MAE) of 3.48°, 3.22°and 3.34° for yaw, pitch and roll respectively. Inter-instrument reliability was excellent for all six cervical movements when compared with the research/clinical-grade CROM device, with intraclass correlation coefficients (ICCs) averaging 0.939. Bland–Altman plots confirmed close agreement between the two methods. Cervical movement trajectory curves further confirmed the concordance between the clinical device and our method. The system is fully automatic, requires only a rear-facing camera, effectively preserves patient privacy, and provides accurate cervical posture estimation. This technology may provide a basis for future applications in neck-disorder screening, remote health monitoring, and personalized musculoskeletal wellness management, although further task-specific clinical validation will be required. To date, HPNet has been validated primarily on a computer-based platform and has not yet been deployed on smartphones. Future work will focus on model lightweighting, mobile deployment, and cross-device adaptation to facilitate its practical implementation on mobile devices.
Open AccessPrivacy-Preserving Head Pose Estimation System for Measuring Cervical Range of Motion
Cervical range of motion (CROM) has been used in research and clinically for assessing cervical health. Gold-standard goniometers tend to be cumbersome. However, Inertial Measurement Units (IMUs) or vision-based alternatives demand frequent calibration and/or costly hardware; moreover, the subject is aware of being measured and there is a risk of breaching privacy. In response, we have developed a non-contact HPNet system for head pose estimation (HPE) that can use a rear-facing camera to quantify CROM accurately. A Re-parameterized Visual Geometry Group (RepVGG)-D2se model is employed as the backbone of the network, and a Spatial Feature Enhancement (SCFE) module is incorporated to improve feature extraction. HPNet was evaluated on the large-scale Carnegie Mellon University (CMU) Panoptic dataset, achieving a mean absolute error (MAE) of 3.48°, 3.22°and 3.34° for yaw, pitch and roll respectively. Inter-instrument reliability was excellent for all six cervical movements when compared with the research/clinical-grade CROM device, with intraclass correlation coefficients (ICCs) averaging 0.939. Bland–Altman plots confirmed close agreement between the two methods. Cervical movement trajectory curves further confirmed the concordance between the clinical device and our method. The system is fully automatic, requires only a rear-facing camera, effectively preserves patient privacy, and provides accurate cervical posture estimation. This technology may provide a basis for future applications in neck-disorder screening, remote health monitoring, and personalized musculoskeletal wellness management, although further task-specific clinical validation will be required. To date, HPNet has been validated primarily on a computer-based platform and has not yet been deployed on smartphones. Future work will focus on model lightweighting, mobile deployment, and cross-device adaptation to facilitate its practical implementation on mobile devices.
- Open Access
- 6 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (24) , 12891
An IoT-Enabled Smart Pillow with Multi-Spectrum Deep Learning Model for Real-Time Snoring Detection and Intervention
Snoring, a common sleep-disordered breathing phenomenon, impairs sleep quality for both the sufferer and any bed partner. While mild snoring primarily disrupts sleep continuity, severe cases often indicate obstructive sleep apnea (OSA), a disorder affecting 9–17% of the global population, linked to significant comorbidities and socioeconomic burden (see Introduction for supporting data). Here, we propose a low-cost, real-time snoring detection and intervention system that integrates a multiple-spectrum deep learning framework with an Internet of Things (IoT)-enabled smart pillow. The modified Parallel Convolutional Spatiotemporal Network (PCSN) combines three parallel convolutional neural network (CNN) branches processing Constant-Q Transform (CQT), Synchrosqueezing Wavelet Transform (SWT), and Hilbert–Huang Transform (HHT) features with a Long Short-Term Memory (LSTM) network to capture spatial and temporal characteristics of sounds associated with snoring. The smart pillow prototype incorporates two Micro-Electro-Mechanical System (MEMS) microphones, an ESP8266 off-shelf board, a speaker, and two vibration motors for real-time audio acquisition, cloud-based processing via Arduino cloud, and closed-loop haptic/audio feedback that encourages positional changes without fully awakening the snorers. Experiments demonstrated that the modified PCSN model achieves 98.33% accuracy, 99.29% sensitivity, 98.34% specificity, 98.3% recall, and 98.32% F1-score, outperforming existing systems. Hardware costs are under USD 8 and a smartphone app provides authorized users with real-time visualization and secure data access. This solution offers a cost-effective and accurate approach for home-based OSA screening and intervention.
- 6 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (24) , 12891
Open AccessAn IoT-Enabled Smart Pillow with Multi-Spectrum Deep Learning Model for Real-Time Snoring Detection and Intervention
Snoring, a common sleep-disordered breathing phenomenon, impairs sleep quality for both the sufferer and any bed partner. While mild snoring primarily disrupts sleep continuity, severe cases often indicate obstructive sleep apnea (OSA), a disorder affecting 9–17% of the global population, linked to significant comorbidities and socioeconomic burden (see Introduction for supporting data). Here, we propose a low-cost, real-time snoring detection and intervention system that integrates a multiple-spectrum deep learning framework with an Internet of Things (IoT)-enabled smart pillow. The modified Parallel Convolutional Spatiotemporal Network (PCSN) combines three parallel convolutional neural network (CNN) branches processing Constant-Q Transform (CQT), Synchrosqueezing Wavelet Transform (SWT), and Hilbert–Huang Transform (HHT) features with a Long Short-Term Memory (LSTM) network to capture spatial and temporal characteristics of sounds associated with snoring. The smart pillow prototype incorporates two Micro-Electro-Mechanical System (MEMS) microphones, an ESP8266 off-shelf board, a speaker, and two vibration motors for real-time audio acquisition, cloud-based processing via Arduino cloud, and closed-loop haptic/audio feedback that encourages positional changes without fully awakening the snorers. Experiments demonstrated that the modified PCSN model achieves 98.33% accuracy, 99.29% sensitivity, 98.34% specificity, 98.3% recall, and 98.32% F1-score, outperforming existing systems. Hardware costs are under USD 8 and a smartphone app provides authorized users with real-time visualization and secure data access. This solution offers a cost-effective and accurate approach for home-based OSA screening and intervention.
- Open Access
Unobtrusive Sleep Posture Detection Using a Smart Bed Mattress with Optimally Distributed Triaxial Accelerometer Array and Parallel Convolutional Spatiotemporal Network
Sleep posture detection is a potentially important component of sleep quality assessment and health monitoring. Accurate identification of sleep postures can offer valuable insights into an individual’s sleep patterns, comfort levels, and potential health risks. For example, improper sleep postures may lead to musculoskeletal issues, respiratory disturbances, and even worsen conditions like sleep apnea. Additionally, for long-term bedridden patients, continuous monitoring of sleep postures is essential to prevent pressure ulcers and other complications. Traditional methods for sleep posture detection have several limitations: wearable sensors can disrupt natural sleep and cause discomfort, camera-based systems raise privacy concerns and are sensitive to environmental conditions, and pressure-sensing mats are often complex and costly. To address these issues, we have developed a low-cost non-contact sleeping posture detection system. Our system features eight optimally distributed triaxial accelerometers, providing a comfortable and non-contact front-end data acquisition unit. For sleep posture classification, we employ an improved density peak clustering algorithm that incorporates the K-nearest neighbor mechanism. Additionally, we have constructed a Parallel Convolutional Spatiotemporal Network (PCSN) by integrating Convolutional Neural Network (CNN), Long Short-Term Memory (LSTM), and Bidirectional Long Short-Term Memory (Bi-LSTM) modules. Experimental results demonstrate that the PCSN can accurately distinguish six sleep postures: prone, supine, left log, left fetus, right log, and right fetus. The average accuracy is 98.42%, outperforming most state-of-the-art deep learning models. The PCSN achieves the highest scores across all metrics: 98.64% precision, 98.18% recall, and 98.10% F1 score. The proposed system shows considerable promise in various applications, including sleep studies and the prevention of diseases like pressure ulcers and sleep apnea.
Open AccessUnobtrusive Sleep Posture Detection Using a Smart Bed Mattress with Optimally Distributed Triaxial Accelerometer Array and Parallel Convolutional Spatiotemporal Network
Sleep posture detection is a potentially important component of sleep quality assessment and health monitoring. Accurate identification of sleep postures can offer valuable insights into an individual’s sleep patterns, comfort levels, and potential health risks. For example, improper sleep postures may lead to musculoskeletal issues, respiratory disturbances, and even worsen conditions like sleep apnea. Additionally, for long-term bedridden patients, continuous monitoring of sleep postures is essential to prevent pressure ulcers and other complications. Traditional methods for sleep posture detection have several limitations: wearable sensors can disrupt natural sleep and cause discomfort, camera-based systems raise privacy concerns and are sensitive to environmental conditions, and pressure-sensing mats are often complex and costly. To address these issues, we have developed a low-cost non-contact sleeping posture detection system. Our system features eight optimally distributed triaxial accelerometers, providing a comfortable and non-contact front-end data acquisition unit. For sleep posture classification, we employ an improved density peak clustering algorithm that incorporates the K-nearest neighbor mechanism. Additionally, we have constructed a Parallel Convolutional Spatiotemporal Network (PCSN) by integrating Convolutional Neural Network (CNN), Long Short-Term Memory (LSTM), and Bidirectional Long Short-Term Memory (Bi-LSTM) modules. Experimental results demonstrate that the PCSN can accurately distinguish six sleep postures: prone, supine, left log, left fetus, right log, and right fetus. The average accuracy is 98.42%, outperforming most state-of-the-art deep learning models. The PCSN achieves the highest scores across all metrics: 98.64% precision, 98.18% recall, and 98.10% F1 score. The proposed system shows considerable promise in various applications, including sleep studies and the prevention of diseases like pressure ulcers and sleep apnea.
- Open Access
Comparative Analysis of Force-Sensitive Resistors and Triaxial Accelerometers for Sitting Posture Classification
Sedentary behaviors, including poor postures, are significantly detrimental to health, particularly for individuals losing motion ability. This study presents a posture detection system utilizing four force-sensitive resistors (FSRs) and two triaxial accelerometers selected after rigorous assessment for consistency and linearity. We compared various machine learning algorithms based on classification accuracy and computational efficiency. The k-nearest neighbor (KNN) algorithm demonstrated superior performance over Decision Tree, Discriminant Analysis, Naive Bayes, and Support Vector Machine (SVM). Further analysis of KNN hyperparameters revealed that the city block metric with K = 3 yielded optimal classification results. Triaxial accelerometers exhibited higher accuracy in both training (99.4%) and testing (99.0%) phases compared to FSRs (96.6% and 95.4%, respectively), with slightly reduced processing times (0.83 s vs. 0.85 s for training; 0.51 s vs. 0.54 s for testing). These findings suggest that, apart from being cost-effective and compact, triaxial accelerometers are more effective than FSRs for posture detection.
Open AccessComparative Analysis of Force-Sensitive Resistors and Triaxial Accelerometers for Sitting Posture Classification
Sedentary behaviors, including poor postures, are significantly detrimental to health, particularly for individuals losing motion ability. This study presents a posture detection system utilizing four force-sensitive resistors (FSRs) and two triaxial accelerometers selected after rigorous assessment for consistency and linearity. We compared various machine learning algorithms based on classification accuracy and computational efficiency. The k-nearest neighbor (KNN) algorithm demonstrated superior performance over Decision Tree, Discriminant Analysis, Naive Bayes, and Support Vector Machine (SVM). Further analysis of KNN hyperparameters revealed that the city block metric with K = 3 yielded optimal classification results. Triaxial accelerometers exhibited higher accuracy in both training (99.4%) and testing (99.0%) phases compared to FSRs (96.6% and 95.4%, respectively), with slightly reduced processing times (0.83 s vs. 0.85 s for training; 0.51 s vs. 0.54 s for testing). These findings suggest that, apart from being cost-effective and compact, triaxial accelerometers are more effective than FSRs for posture detection.
- Open Access
Healthcare Monitoring Using Low-Cost Sensors to Supplement and Replace Human Sensation: Does It Have Potential to Increase Independent Living and Prevent Disease?
Continuous monitoring of health status has the potential to enhance the quality of life and life expectancy of people suffering from chronic illness and of the elderly. However, such systems can only come into widespread use if the cost of manufacturing is low. Advancements in material science and engineering technology have led to a significant decrease in the expense of developing healthcare monitoring devices. This review aims to investigate the progress of the use of low-cost sensors in healthcare monitoring and discusses the challenges faced when accomplishing continuous and real-time monitoring tasks. The major findings include (1) only a small number of publications (N = 50) have addressed the issue of healthcare monitoring applications using low-cost sensors over the past two decades; (2) the top three algorithms used to process sensor data include SA (Statistical Analysis, 30%), SVM (Support Vector Machine, 18%), and KNN (K-Nearest Neighbour, 12%); and (3) wireless communication techniques (Zigbee, Bluetooth, Wi-Fi, and RF) serve as the major data transmission tools (77%) followed by cable connection (13%) and SD card data storage (10%). Due to the small fraction (N = 50) of low-cost sensor-based studies among thousands of published articles about healthcare monitoring, this review not only summarises the progress of related research but calls for researchers to devote more effort to the consideration of cost reduction as well as the size of these components.
Open AccessHealthcare Monitoring Using Low-Cost Sensors to Supplement and Replace Human Sensation: Does It Have Potential to Increase Independent Living and Prevent Disease?
Continuous monitoring of health status has the potential to enhance the quality of life and life expectancy of people suffering from chronic illness and of the elderly. However, such systems can only come into widespread use if the cost of manufacturing is low. Advancements in material science and engineering technology have led to a significant decrease in the expense of developing healthcare monitoring devices. This review aims to investigate the progress of the use of low-cost sensors in healthcare monitoring and discusses the challenges faced when accomplishing continuous and real-time monitoring tasks. The major findings include (1) only a small number of publications (N = 50) have addressed the issue of healthcare monitoring applications using low-cost sensors over the past two decades; (2) the top three algorithms used to process sensor data include SA (Statistical Analysis, 30%), SVM (Support Vector Machine, 18%), and KNN (K-Nearest Neighbour, 12%); and (3) wireless communication techniques (Zigbee, Bluetooth, Wi-Fi, and RF) serve as the major data transmission tools (77%) followed by cable connection (13%) and SD card data storage (10%). Due to the small fraction (N = 50) of low-cost sensor-based studies among thousands of published articles about healthcare monitoring, this review not only summarises the progress of related research but calls for researchers to devote more effort to the consideration of cost reduction as well as the size of these components.
- Open Access
A Single Subject, Feasibility Study of Using a Non-Contact Measurement to “Visualize” Temperature at Body-Seat Interface
Measuring temperature changes at the body-seat interface has been drawing increased attention from both industrial and scientific fields, due to the increasingly sedentary nature from daily leisure activity to routine work. Although contact measurement is considered the gold standard, it can affect the local micro-environment and the perception of sitting comfort. A non-contact temperature measurement system was developed to determine the interface temperature using data gathered unobtrusively and continuously from an infrared sensor (IRs). System performance was evaluated regarding linearity, hysteresis, reliability and accuracy. Then a healthy participant sat for an hour on low/intermediate density foams with thickness varying from 0.5–8 cm while body-seat interface temperature was measured simultaneously using a temperature sensor (contact) and an IRs (non-contact). IRs data were filtered with empirical mode decomposition and fractal scaling indices before a data-driven artificial neural network was utilized to estimate the contact surface temperature. A strong correlation existed between non-contact and contact temperature measurement ( > 0.85) and the estimation results showed a low root mean square error (RMSE) (<0.07 for low density foam and <0.16 for intermediate density foam) and high Nash-Sutcliff efficiency (NSE) values (≈1 for both types of foam materials).Open AccessA Single Subject, Feasibility Study of Using a Non-Contact Measurement to “Visualize” Temperature at Body-Seat Interface
Measuring temperature changes at the body-seat interface has been drawing increased attention from both industrial and scientific fields, due to the increasingly sedentary nature from daily leisure activity to routine work. Although contact measurement is considered the gold standard, it can affect the local micro-environment and the perception of sitting comfort. A non-contact temperature measurement system was developed to determine the interface temperature using data gathered unobtrusively and continuously from an infrared sensor (IRs). System performance was evaluated regarding linearity, hysteresis, reliability and accuracy. Then a healthy participant sat for an hour on low/intermediate density foams with thickness varying from 0.5–8 cm while body-seat interface temperature was measured simultaneously using a temperature sensor (contact) and an IRs (non-contact). IRs data were filtered with empirical mode decomposition and fractal scaling indices before a data-driven artificial neural network was utilized to estimate the contact surface temperature. A strong correlation existed between non-contact and contact temperature measurement ( > 0.85) and the estimation results showed a low root mean square error (RMSE) (<0.07 for low density foam and <0.16 for intermediate density foam) and high Nash-Sutcliff efficiency (NSE) values (≈1 for both types of foam materials). - Open Access
Review of Measuring Microenvironmental Changes at the Body–Seat Interface and the Relationship between Object Measurement and Subjective Evaluation
Being seated has increasingly pervaded both working and leisure lifestyles, with development of more comfortable seating surfaces dependent on feedback from subjective questionnaires and design aesthetics. As a consequence, research has become focused on how to objectively resolve factors that might underpin comfort and discomfort. This review summarizes objective methods of measuring the microenvironmental changes at the body–seat interface and examines the relationship between objective measurement and subjective sensation. From the perspective of physical parameters, pressure detection accounted for nearly two thirds (37/54) of the publications, followed by microclimatic information (temperature and relative humidity: 18/54): it is to be noted that one article included both microclimate and pressure measurements and was placed into both categories. In fact, accumulated temperature and relative humidity at the body–seat interface have similarly negative effects on prolonged sitting to that of unrelieved pressure. Another interesting finding was the correlation between objective measurement and subjective evaluation; however, the validity of this may be called into question because of the differences in experiment design between studies.
Open AccessReview of Measuring Microenvironmental Changes at the Body–Seat Interface and the Relationship between Object Measurement and Subjective Evaluation
Being seated has increasingly pervaded both working and leisure lifestyles, with development of more comfortable seating surfaces dependent on feedback from subjective questionnaires and design aesthetics. As a consequence, research has become focused on how to objectively resolve factors that might underpin comfort and discomfort. This review summarizes objective methods of measuring the microenvironmental changes at the body–seat interface and examines the relationship between objective measurement and subjective sensation. From the perspective of physical parameters, pressure detection accounted for nearly two thirds (37/54) of the publications, followed by microclimatic information (temperature and relative humidity: 18/54): it is to be noted that one article included both microclimate and pressure measurements and was placed into both categories. In fact, accumulated temperature and relative humidity at the body–seat interface have similarly negative effects on prolonged sitting to that of unrelieved pressure. Another interesting finding was the correlation between objective measurement and subjective evaluation; however, the validity of this may be called into question because of the differences in experiment design between studies.
- Open Access
In-Depth Investigation into the Transient Humidity Response at the Body-Seat Interface on Initial Contact Using a Dual Temperature and Humidity Sensor
Relative humidity (RH) at the body-seat interface is considered an important factor in both sitting comfort and generation of health concerns such as skin lesions. Technical difficulties appear to have limited research aimed at the detailed and simultaneous exploration of RH and temperature changes at the body-seat interface; using RH sensors without the capability to record temperature where RH is recorded. To explore the causes of a spike in RH consistently produced on first contact between body and seat surface, we report data from the first use of dual temperature and RH (HTU21D) sensors in this interface. Following evaluation of sensor performance, the effect of local thermal changes on RH was investigated. The expected strong negative correlation between temperature and RH (R2 = −0.94) supported the importance of considering both parameters when studying impact of sitting on skin health. The influence of sensor movement speed (higher velocity approach: 0.32 cm/s ± 0.01 cm/s; lower velocity approach: 0.17 cm/s ± 0.01 cm/s) into a static RH region associated with a higher local temperature were compared with data gathered by altering the rate of a person sitting. In all cases, the faster sitting down (or equivalent) generated larger RH outcomes: e.g., in human sitting 53.7% ± 3.3% RH (left mid-thigh), 56.4% ± 5.1% RH (right mid-thigh) and 53.2% ± 2.7% RH (Coccyx). Differences in size of RH change were seen across the measurement locations used to study the body-seat interface. The initial sitting contact induces a transient RH response (duration ≤ 40 s) that does not accurately reflect the microenvironment at the body-seat interface. It is likely that any movement during sitting would result in similar artefact formation. As a result, caution should be taken when investigating RH performance at any enclosed interface when the surfaces may have different temperatures and movement may occur.
Open AccessIn-Depth Investigation into the Transient Humidity Response at the Body-Seat Interface on Initial Contact Using a Dual Temperature and Humidity Sensor
Relative humidity (RH) at the body-seat interface is considered an important factor in both sitting comfort and generation of health concerns such as skin lesions. Technical difficulties appear to have limited research aimed at the detailed and simultaneous exploration of RH and temperature changes at the body-seat interface; using RH sensors without the capability to record temperature where RH is recorded. To explore the causes of a spike in RH consistently produced on first contact between body and seat surface, we report data from the first use of dual temperature and RH (HTU21D) sensors in this interface. Following evaluation of sensor performance, the effect of local thermal changes on RH was investigated. The expected strong negative correlation between temperature and RH (R2 = −0.94) supported the importance of considering both parameters when studying impact of sitting on skin health. The influence of sensor movement speed (higher velocity approach: 0.32 cm/s ± 0.01 cm/s; lower velocity approach: 0.17 cm/s ± 0.01 cm/s) into a static RH region associated with a higher local temperature were compared with data gathered by altering the rate of a person sitting. In all cases, the faster sitting down (or equivalent) generated larger RH outcomes: e.g., in human sitting 53.7% ± 3.3% RH (left mid-thigh), 56.4% ± 5.1% RH (right mid-thigh) and 53.2% ± 2.7% RH (Coccyx). Differences in size of RH change were seen across the measurement locations used to study the body-seat interface. The initial sitting contact induces a transient RH response (duration ≤ 40 s) that does not accurately reflect the microenvironment at the body-seat interface. It is likely that any movement during sitting would result in similar artefact formation. As a result, caution should be taken when investigating RH performance at any enclosed interface when the surfaces may have different temperatures and movement may occur.
- 1 August 2018
- Published by Elsevier in Complementary Therapies in Medicine
- Vol. 39, 1-7
A pilot study assessing patient-centred care in patients with chronic health conditions attending chiropractic practice
- 1 August 2018
- Published by Elsevier in Complementary Therapies in Medicine
- Vol. 39, 1-7
A pilot study assessing patient-centred care in patients with chronic health conditions attending chiropractic practice
- Open Access
Performance Assessment of a Humidity Measurement System and Its Use to Evaluate Moisture Characteristics of Wheelchair Cushions at the User–Seat Interface
Little is known about the changes in moisture that occur at the body–seat interface during sitting. However, as increased moisture can add to the risk of skin damage, we have developed an array of MEMS (Micro-Electro-Mechanical System) humidity sensors to measure at this interface. Sensors were first evaluated against traceable standards, followed by use in a cross-over field test (n = 11; 20 min duration) using different wheelchair cushions (foam and gel). Relative humidity (RH) was measured at the left mid-thigh, right mid-thigh and coccyx. Sensors were shown to be unaffected by loading and showed highly reliable responses to measured changes in humidity, varying little from the traceable standard (<5%). Field-test data, smoothed through a moving average filter, revealed significant differences between the three chosen locations and between the gel and foam cushions. Maximum RH was attained in less than five minutes regardless of cushion material (foam or gel). Importantly, RH does not appear to distribute uniformly over the body–seat interface; suggesting multiple sensor positions would appear essential for effectively monitoring moisture in this interface. Material properties of the cushions appear to have a significant effect on RH characteristics (profile) at the body–seat interface, but not necessarily the time to peak moisture.
Open AccessPerformance Assessment of a Humidity Measurement System and Its Use to Evaluate Moisture Characteristics of Wheelchair Cushions at the User–Seat Interface
Little is known about the changes in moisture that occur at the body–seat interface during sitting. However, as increased moisture can add to the risk of skin damage, we have developed an array of MEMS (Micro-Electro-Mechanical System) humidity sensors to measure at this interface. Sensors were first evaluated against traceable standards, followed by use in a cross-over field test (n = 11; 20 min duration) using different wheelchair cushions (foam and gel). Relative humidity (RH) was measured at the left mid-thigh, right mid-thigh and coccyx. Sensors were shown to be unaffected by loading and showed highly reliable responses to measured changes in humidity, varying little from the traceable standard (<5%). Field-test data, smoothed through a moving average filter, revealed significant differences between the three chosen locations and between the gel and foam cushions. Maximum RH was attained in less than five minutes regardless of cushion material (foam or gel). Importantly, RH does not appear to distribute uniformly over the body–seat interface; suggesting multiple sensor positions would appear essential for effectively monitoring moisture in this interface. Material properties of the cushions appear to have a significant effect on RH characteristics (profile) at the body–seat interface, but not necessarily the time to peak moisture.