Carolina Larrazábal-Morón
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Carolina Larrazábal-Morón has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- María Dolores Gómez-Adrián
Oral Surgery Unit, Department of Dentistry, School of Medicine and Health Sciences, Catholic University of Valencia, 46007 Valencia, Spain
5 shared publications - Javier Barberá-Millán
Oral Surgery Unit, Department of Dentistry, Faculty of Medicine and Health Sciences, Catholic University of Valencia San Vicente Mártir, C/Quevedo, 2, 46001 Valencia, Spain
4 shared publications - Aritza Brizuela-Velasco
DENS-ia Research Group, Faculty of Health Sciences, Miguel de Cervantes European University, 47012 Valladolid, Spain
3 shared publications - Julián Espinosa-Giménez
Oral Surgery Unit, Department of Dentistry, School of Medicine and Health Sciences, Catholic University of Valencia, 46007 Valencia, Spain
3 shared publications - Miguel Peñarrocha-Diago
Department of Oral Surgery, School of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain
3 shared publications B. Garcia-Mira
2 shared publications
Latest Publications
- Open Access
- 3 December 2025
- Published by MDPI AG in Dentistry Journal
- Vol. 13 (12) , 574
Fracture Resistance of Zirconia-Reinforced Lithium Silicate in Single Posterior Implant-Supported Crowns: An In Vitro Study
Background/Objectives: Zirconia-reinforced lithium silicate (ZLS) is a glass–ceramic that combines the translucency of lithium disilicate with the enhanced strength provided by dispersed zirconia crystals. Evidence on the mechanical behavior of ZLS implant-supported crowns remains limited. This study evaluated the fracture resistance of posterior monolithic ZLS crowns and analyzed the influence of cement type and artificial aging. Methods: Forty ZLS crowns (Celtra™ Duo) were fabricated, cemented onto straight titanium abutments and assigned to four groups (n = 10) according to cement type (adhesive or self-adhesive) and aging (500,000 cycles at 150 N). Specimens underwent axial load-to-fracture testing using a universal testing machine. Data were analyzed with Student’s t-tests and Kruskal–Wallis tests (α = 0.05). Results: Mean fracture resistance was 1625.46 ± 340.02 N. Although adhesive cement showed higher mean values than self-adhesive cement, no statistically significant differences were found (p = 0.102). Artificial aging also produced no significant reduction in fracture resistance (p = 0.674). All groups exceeded the physiological posterior occlusal forces. Conclusions: Monolithic ZLS crowns cemented onto titanium abutments demonstrated high fracture resistance under axial loading. Within the limitations of this in vitro design, neither cement type nor mechanical aging significantly affected performance. These findings support the mechanical feasibility of ZLS for posterior implant-supported single crowns, although further studies including thermomechanical aging and oblique loading are required.
- 3 December 2025
- Published by MDPI AG in Dentistry Journal
- Vol. 13 (12) , 574
Open AccessFracture Resistance of Zirconia-Reinforced Lithium Silicate in Single Posterior Implant-Supported Crowns: An In Vitro Study
Background/Objectives: Zirconia-reinforced lithium silicate (ZLS) is a glass–ceramic that combines the translucency of lithium disilicate with the enhanced strength provided by dispersed zirconia crystals. Evidence on the mechanical behavior of ZLS implant-supported crowns remains limited. This study evaluated the fracture resistance of posterior monolithic ZLS crowns and analyzed the influence of cement type and artificial aging. Methods: Forty ZLS crowns (Celtra™ Duo) were fabricated, cemented onto straight titanium abutments and assigned to four groups (n = 10) according to cement type (adhesive or self-adhesive) and aging (500,000 cycles at 150 N). Specimens underwent axial load-to-fracture testing using a universal testing machine. Data were analyzed with Student’s t-tests and Kruskal–Wallis tests (α = 0.05). Results: Mean fracture resistance was 1625.46 ± 340.02 N. Although adhesive cement showed higher mean values than self-adhesive cement, no statistically significant differences were found (p = 0.102). Artificial aging also produced no significant reduction in fracture resistance (p = 0.674). All groups exceeded the physiological posterior occlusal forces. Conclusions: Monolithic ZLS crowns cemented onto titanium abutments demonstrated high fracture resistance under axial loading. Within the limitations of this in vitro design, neither cement type nor mechanical aging significantly affected performance. These findings support the mechanical feasibility of ZLS for posterior implant-supported single crowns, although further studies including thermomechanical aging and oblique loading are required.
- Open Access
- 4 May 2024
- Published by MDPI AG in Biomimetics
- Vol. 9 (5) , 276
Radiographic Study of Transcrestal Sinus Floor Elevation Using Osseodensification Technique with Graft Material: A Pilot Study
This pilot study aimed to evaluate the level of implant success after transcrestal sinus floor elevation (tSFE) using the osseodensification technique (OD) combined with beta-tricalcium phosphate (β-TCP) by analyzing clinical and radiographic results. Moreover, the increase in bone height was analyzed immediately after surgery, 3 months after, and before loading by taking standardized radiographic measurements. Thirteen patients, four males and nine females, with a mean age of 54.69 ± 5.86 years, requiring the placement of one implant in the upper posterior maxilla, with a residual bone height of p < 0.05). The results of the study indicated a 100% implant success rate after a follow-up period of twelve months. Preoperative main bone height was 5.70 ± 0.95 mm. The osseodensification technique allowed a significant increase of 6.65 ± 1.06 mm immediately after surgery. After a twelve-month follow-up, a graft material contraction of 0.90 ± 0.49 mm was observed. No correlation was observed between the bone height at the different times of the study and the primary stability of the implant. Considering the limitations of the size sample of this study, the osseodensification technique used for transcrestal sinus lift with the additional bone graft material (β-TCP) may provide a predictable elevation of the maxillary sinus floor, allowing simultaneous implant insertion with adequate stability irrespective of bone height limitations.
- 4 May 2024
- Published by MDPI AG in Biomimetics
- Vol. 9 (5) , 276
Open AccessRadiographic Study of Transcrestal Sinus Floor Elevation Using Osseodensification Technique with Graft Material: A Pilot Study
This pilot study aimed to evaluate the level of implant success after transcrestal sinus floor elevation (tSFE) using the osseodensification technique (OD) combined with beta-tricalcium phosphate (β-TCP) by analyzing clinical and radiographic results. Moreover, the increase in bone height was analyzed immediately after surgery, 3 months after, and before loading by taking standardized radiographic measurements. Thirteen patients, four males and nine females, with a mean age of 54.69 ± 5.86 years, requiring the placement of one implant in the upper posterior maxilla, with a residual bone height of p < 0.05). The results of the study indicated a 100% implant success rate after a follow-up period of twelve months. Preoperative main bone height was 5.70 ± 0.95 mm. The osseodensification technique allowed a significant increase of 6.65 ± 1.06 mm immediately after surgery. After a twelve-month follow-up, a graft material contraction of 0.90 ± 0.49 mm was observed. No correlation was observed between the bone height at the different times of the study and the primary stability of the implant. Considering the limitations of the size sample of this study, the osseodensification technique used for transcrestal sinus lift with the additional bone graft material (β-TCP) may provide a predictable elevation of the maxillary sinus floor, allowing simultaneous implant insertion with adequate stability irrespective of bone height limitations.
- Open Access
- 18 March 2024
- Published by MDPI AG in Preprints.org
Radiographic Study of Transcrestal Sinus Floor Elevation Using Osseodensification Technique with Graft Material: A Non-randomized Pilot Clinical Trial
The study aimed to evaluate implant success and bone height variations after transcrestal sinus floor elevation (tSFE) using the osseodensification technique (OD) combined with beta-tricalcium phosphate (β-TCP), as bone graft material and simultaneous implant placement. Thirteen patients requiring the placement of one implant in the upper posterior maxilla, with a residual bone height of
- 18 March 2024
- Published by MDPI AG in Preprints.org
Open AccessRadiographic Study of Transcrestal Sinus Floor Elevation Using Osseodensification Technique with Graft Material: A Non-randomized Pilot Clinical Trial
The study aimed to evaluate implant success and bone height variations after transcrestal sinus floor elevation (tSFE) using the osseodensification technique (OD) combined with beta-tricalcium phosphate (β-TCP), as bone graft material and simultaneous implant placement. Thirteen patients requiring the placement of one implant in the upper posterior maxilla, with a residual bone height of
- Open Access
A Biomechanical Analysis of the Influence of the Morfology of the Bone Blocks Grafts on the Transfer of Tension or Load to the Soft Tissue by Means of the Finite Elements Method
Edentulism produces resorption of alveolar bone processes, which can complicate placement of dental implants. Guided bone regeneration techniques aim to recover the volume of bone. These treatments are susceptible to the surgical technique employed, the design of the autologous block or the tension of the suture. These factors can relate to major complications as the lack of primary closure and dehiscence. The present study, using finite element analysis, aimed to determine differences in terms of displacement of the oral mucosa, transferred stress according to Von Mises and deformation of soft tissue when two block graft designs (right-angled and rounded) and two levels of suture tension (0.05 and 0.2 N) were combined. The results showed that all the variables analyzed were greater with 0.2 N. Regarding the design of the block, no difference was found in the transferred stress and deformation of the soft tissue. However, displacement was related to a tendency to dehiscence (25% greater in the right-angled/chamfer design). In conclusion different biomechanical behavior was observed in the block graft depending on the design and suture tension, so it is recommended to use low suture tension and rounded design. A novel finite element analysis model is presented for future investigations.
Open AccessA Biomechanical Analysis of the Influence of the Morfology of the Bone Blocks Grafts on the Transfer of Tension or Load to the Soft Tissue by Means of the Finite Elements Method
Edentulism produces resorption of alveolar bone processes, which can complicate placement of dental implants. Guided bone regeneration techniques aim to recover the volume of bone. These treatments are susceptible to the surgical technique employed, the design of the autologous block or the tension of the suture. These factors can relate to major complications as the lack of primary closure and dehiscence. The present study, using finite element analysis, aimed to determine differences in terms of displacement of the oral mucosa, transferred stress according to Von Mises and deformation of soft tissue when two block graft designs (right-angled and rounded) and two levels of suture tension (0.05 and 0.2 N) were combined. The results showed that all the variables analyzed were greater with 0.2 N. Regarding the design of the block, no difference was found in the transferred stress and deformation of the soft tissue. However, displacement was related to a tendency to dehiscence (25% greater in the right-angled/chamfer design). In conclusion different biomechanical behavior was observed in the block graft depending on the design and suture tension, so it is recommended to use low suture tension and rounded design. A novel finite element analysis model is presented for future investigations.
- Open Access
- 30 July 2021
- Published by MDPI AG in Dentistry Journal
- Vol. 9 (8) , 84
Adjuvant Effect of Titanium Brushes in Peri-Implant Surgical Treatment: A Systematic Review
Background: the prognosis of peri-implant surgery can be affected by poor decontamination of the implant surface, which could be improved with the use of titanium brushes. The objectives of this systematic review were to evaluate the effectiveness of titanium brushes in the decontamination of the implant surface in terms of plaque index, probing depth, bleeding on probing and bone loss/gain; as well as its effectiveness according to the type of peri-implant bone defect. Methods: an electronic search was carried out in the PubMed, Scopus, Cochrane and Embase databases, as well as a manual search. The search strategy included four keywords: “Peri-implantitis”, “Periimplantitis”, “Implant Surface Decontamination” and “Titanium Brush”. Randomized controlled studies published in the last 10 years were included and systematic reviews, in vitro studies and animal studies were excluded. Results: 142 references were found, from which only four articles met the inclusion criteria. All of the studies included in the present review reported beneficial results in terms of probing depth, gingival index and radiographic bone loss and gain after implant surface decontamination adjuvated by titanium brushes. Conclusions: titanium rotary brushes show improvements in the evolution and prognosis of peri-implant surgery, although more long-term studies are needed to draw more solid conclusions.
- 30 July 2021
- Published by MDPI AG in Dentistry Journal
- Vol. 9 (8) , 84
Open AccessAdjuvant Effect of Titanium Brushes in Peri-Implant Surgical Treatment: A Systematic Review
Background: the prognosis of peri-implant surgery can be affected by poor decontamination of the implant surface, which could be improved with the use of titanium brushes. The objectives of this systematic review were to evaluate the effectiveness of titanium brushes in the decontamination of the implant surface in terms of plaque index, probing depth, bleeding on probing and bone loss/gain; as well as its effectiveness according to the type of peri-implant bone defect. Methods: an electronic search was carried out in the PubMed, Scopus, Cochrane and Embase databases, as well as a manual search. The search strategy included four keywords: “Peri-implantitis”, “Periimplantitis”, “Implant Surface Decontamination” and “Titanium Brush”. Randomized controlled studies published in the last 10 years were included and systematic reviews, in vitro studies and animal studies were excluded. Results: 142 references were found, from which only four articles met the inclusion criteria. All of the studies included in the present review reported beneficial results in terms of probing depth, gingival index and radiographic bone loss and gain after implant surface decontamination adjuvated by titanium brushes. Conclusions: titanium rotary brushes show improvements in the evolution and prognosis of peri-implant surgery, although more long-term studies are needed to draw more solid conclusions.
- Open Access
- 1 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Logistic Regression Analysis of the Factors Involved in the Failure of Osseointegration and Survival of Dental Implants with an Internal Connection and Machined Collar: A 6‐Year Retrospective Cohort Study
Background. Although the long‐term success rate of dental implants is currently close to 95%, it is necessary to provide more evidence on the factors related to the failure of osseointegration and survival. Purpose. To establish the risk factors associated with the failure of osseointegration and survival of dental implants with an internal connection and machined collar and to establish a predictive statistical model. Materials and Methods. An analytical, retrospective, and observational clinical study of a sample of 297 implants with a follow‐up of up to 76 months. Independent variables related to the implant, patient, and surgical and rehabilitative procedures were identified. The dependent variables were failure of osseointegration and failure of implant survival after prosthetic loading. A survival analysis was carried out by applying the Kaplan‐Meier model (significance for p < 0.05). The log‐rank test and the Cox regression analysis were applied to the factors that presented differences. Finally, the regression logit function was used to determine whether it is possible to predict the risk of implant failure according to the analyzed variables with the data obtained in this study. Results. The percentages of osseointegration and survival were 97.6 and 97.2%, respectively. For osseointegration, there were significant differences according to gender (p = 0.048), and the risk of nonosseointegration was 85% lower in women. Regarding survival, the Cox analysis converged on only two factors, which were smoking and treatment with anticoagulant drugs. The risk of loss was multiplied by 18.3 for patients smoking more than 10 cigarettes per day and by 28.2 for patients treated with anticoagulants. Conclusions. The indicated risk factors should be considered, but the analysis of the results is not sufficient to create a predictive model.
- 1 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Open AccessLogistic Regression Analysis of the Factors Involved in the Failure of Osseointegration and Survival of Dental Implants with an Internal Connection and Machined Collar: A 6‐Year Retrospective Cohort Study
Background. Although the long‐term success rate of dental implants is currently close to 95%, it is necessary to provide more evidence on the factors related to the failure of osseointegration and survival. Purpose. To establish the risk factors associated with the failure of osseointegration and survival of dental implants with an internal connection and machined collar and to establish a predictive statistical model. Materials and Methods. An analytical, retrospective, and observational clinical study of a sample of 297 implants with a follow‐up of up to 76 months. Independent variables related to the implant, patient, and surgical and rehabilitative procedures were identified. The dependent variables were failure of osseointegration and failure of implant survival after prosthetic loading. A survival analysis was carried out by applying the Kaplan‐Meier model (significance for p < 0.05). The log‐rank test and the Cox regression analysis were applied to the factors that presented differences. Finally, the regression logit function was used to determine whether it is possible to predict the risk of implant failure according to the analyzed variables with the data obtained in this study. Results. The percentages of osseointegration and survival were 97.6 and 97.2%, respectively. For osseointegration, there were significant differences according to gender (p = 0.048), and the risk of nonosseointegration was 85% lower in women. Regarding survival, the Cox analysis converged on only two factors, which were smoking and treatment with anticoagulant drugs. The risk of loss was multiplied by 18.3 for patients smoking more than 10 cigarettes per day and by 28.2 for patients treated with anticoagulants. Conclusions. The indicated risk factors should be considered, but the analysis of the results is not sufficient to create a predictive model.
- 4 April 2016
- Published by Elsevier in The Spine Journal
- Vol. 16 (11) , e737
Anatomic variation of the vertebral artery
- 4 April 2016
- Published by Elsevier in The Spine Journal
- Vol. 16 (11) , e737
Anatomic variation of the vertebral artery
- Open Access
- 1 January 2014
- Published by Medicina Oral, S.L. in Journal of Clinical and Experimental Dentistry
- Vol. 6 (5) , e479-e484
Osteotome sinus floor elevation without grafting material: Results of a 2-year prospective study
The aim of this prospective clinical trial was to evaluate the success implant rates during 24 months using OSFE procedure without grafting materials. 42 adult patients (22 female, 15 male) were selected according to Nedir et al´s inclusion criteria of which 5 patients were excluded, due to periapical pathology in adjacent teeth (n=3) and treatment with bisphosphonates (n=2). 37 patients aged 31-68 years were selected. Smokers were divided in two groups depending on the number of cigarettes consumed per day (a) 0-10, (b) 11-20. One patient was excluded because he was lost to follow-up at 24 months A total of 36 threaded implants were placed, ∅4,1mm Straumann® (Straumann AG, Waldenburg, Switzerland) and ∅3,5mm Klockner® (Klockner Implant System, Barcelona, Spain). The most used implant diameter was 4,1 mm (n=29), followed by 3,5 mm (n=7), and length used was 10 mm (n=32) and 8 mm (n=4). Initial RBH ranged from 4 mm to 9 mm. All statistical data were processed using the program R 3.0.2 for windows. A total of 36 threaded implants were placed. Residual bone height (RBH) at implant placement averaged 7,4 ± 0,4 mm. Mean bone gain was 1,8 ± 0,3 mm. Four implants showed a bone gain exceeding 3 mm. Mean implant protrusion length into the sinus amounted to 2.1 ± 0,3 mm. Regarding the relationship between smoking and periodontal probes, no statistically significant differences were found (P=0,25), neither in relation to the number of threads that the implants showed (P=0,29) or bone gain (P=0,79). After 24 months the implant success rate was 91,6%. Implant rehabilitation of edentulous atrophied posterior maxilla can be safely performed and simplified using the OSFE technique without grafting with reliable long-term results. Key words:Crestal bone loss, dental implants, internal sinus lift, no grafting, osteotome sinus elevation, grafting, sinus floor elevation.
- 1 January 2014
- Published by Medicina Oral, S.L. in Journal of Clinical and Experimental Dentistry
- Vol. 6 (5) , e479-e484
Open AccessOsteotome sinus floor elevation without grafting material: Results of a 2-year prospective study
The aim of this prospective clinical trial was to evaluate the success implant rates during 24 months using OSFE procedure without grafting materials. 42 adult patients (22 female, 15 male) were selected according to Nedir et al´s inclusion criteria of which 5 patients were excluded, due to periapical pathology in adjacent teeth (n=3) and treatment with bisphosphonates (n=2). 37 patients aged 31-68 years were selected. Smokers were divided in two groups depending on the number of cigarettes consumed per day (a) 0-10, (b) 11-20. One patient was excluded because he was lost to follow-up at 24 months A total of 36 threaded implants were placed, ∅4,1mm Straumann® (Straumann AG, Waldenburg, Switzerland) and ∅3,5mm Klockner® (Klockner Implant System, Barcelona, Spain). The most used implant diameter was 4,1 mm (n=29), followed by 3,5 mm (n=7), and length used was 10 mm (n=32) and 8 mm (n=4). Initial RBH ranged from 4 mm to 9 mm. All statistical data were processed using the program R 3.0.2 for windows. A total of 36 threaded implants were placed. Residual bone height (RBH) at implant placement averaged 7,4 ± 0,4 mm. Mean bone gain was 1,8 ± 0,3 mm. Four implants showed a bone gain exceeding 3 mm. Mean implant protrusion length into the sinus amounted to 2.1 ± 0,3 mm. Regarding the relationship between smoking and periodontal probes, no statistically significant differences were found (P=0,25), neither in relation to the number of threads that the implants showed (P=0,29) or bone gain (P=0,79). After 24 months the implant success rate was 91,6%. Implant rehabilitation of edentulous atrophied posterior maxilla can be safely performed and simplified using the OSFE technique without grafting with reliable long-term results. Key words:Crestal bone loss, dental implants, internal sinus lift, no grafting, osteotome sinus elevation, grafting, sinus floor elevation.
- Open Access
- 1 January 2010
- Published by Medicina Oral, S.L. in Medicina Oral Patología Oral y Cirugia Bucal
- Vol. 15 (5) , e755-e759
Distal probing depth and attachment level of lower second molars following surgical extraction of lower third molars: A literature review
A review of the literature is made to evaluate factors that influence probing depth and attachment level on the distal aspect of the lower second molar (L2M) following extraction of a lower third molar (L3M). The PubMed database was searched for studies published between 1997 and March 2009 using the following keywords: mandibular third molar, distal periodontal defect, distal probing depth, distal attachment level, flap design. Randomized prospective studies, with a minimum follow-up of three months for which the full text could be obtained, and that indicated the attachment level and/or probing depth on the distal surface of the L2M in both the preoperative and postoperative periods were included. In the studies obtained, flap design had no influence on distal probing depth or distal attachment level of the L2M following extraction of an L3M. Curettage of the distal radicular surface of the L2M, together with oral hygiene control by the dentist, reduced probing depth values. Various authors recommend bone regeneration techniques in patients with a distal periodontal defect prior to extraction. The placing of membranes (resorbable or nonresorbable) is not justified; however, the use of demineralized bone powder or platelet-rich plasma gel reduces the distal probing depth and attachment level of the L2M.
- 1 January 2010
- Published by Medicina Oral, S.L. in Medicina Oral Patología Oral y Cirugia Bucal
- Vol. 15 (5) , e755-e759
Open AccessDistal probing depth and attachment level of lower second molars following surgical extraction of lower third molars: A literature review
A review of the literature is made to evaluate factors that influence probing depth and attachment level on the distal aspect of the lower second molar (L2M) following extraction of a lower third molar (L3M). The PubMed database was searched for studies published between 1997 and March 2009 using the following keywords: mandibular third molar, distal periodontal defect, distal probing depth, distal attachment level, flap design. Randomized prospective studies, with a minimum follow-up of three months for which the full text could be obtained, and that indicated the attachment level and/or probing depth on the distal surface of the L2M in both the preoperative and postoperative periods were included. In the studies obtained, flap design had no influence on distal probing depth or distal attachment level of the L2M following extraction of an L3M. Curettage of the distal radicular surface of the L2M, together with oral hygiene control by the dentist, reduced probing depth values. Various authors recommend bone regeneration techniques in patients with a distal periodontal defect prior to extraction. The placing of membranes (resorbable or nonresorbable) is not justified; however, the use of demineralized bone powder or platelet-rich plasma gel reduces the distal probing depth and attachment level of the L2M.
- 1 January 2010
- Published by Medicina Oral, S.L. in Medicina Oral Patología Oral y Cirugia Bucal
- Vol. 15 (6) , e886-e890
Radiographic signs associated with inferior alveolar nerve damage following lower third molar extraction
The aim was to carry out a literature review of preoperative radiographic signs in orthopantomography (OPG) and computed tomography (CT) related with the risk of inferior alveolar nerve damage during the surgical extraction of lower third molar (LTM). A search was made on PubMed for literature published between the years 2000 and 2009. In the reviewed literature, radiographic signs in the OPG that indicate a relationship between the LTM and the inferior alveolar canal are considered a risk factor for nerve damage. These signs are darkening and deflection of the root, and diversion and interruption in the white line of the canal. In the majority of these studies, the routine use of CT is not justified, and is only recommended when radiographic signs appear in the OPG that demonstrate a direct anatomical relationship between the LTM and the canal. In the CT, the absence of cortical bone in the canal implies a contact between the root of the LTM and the canal, and is related with the presence of some radiographic signs in the OPG. Some studies demonstrate that despite the absence of cortical bone, the risk of lesion or exposure of the nerve during the extraction of LTM was low.
- 1 January 2010
- Published by Medicina Oral, S.L. in Medicina Oral Patología Oral y Cirugia Bucal
- Vol. 15 (6) , e886-e890
Radiographic signs associated with inferior alveolar nerve damage following lower third molar extraction
The aim was to carry out a literature review of preoperative radiographic signs in orthopantomography (OPG) and computed tomography (CT) related with the risk of inferior alveolar nerve damage during the surgical extraction of lower third molar (LTM). A search was made on PubMed for literature published between the years 2000 and 2009. In the reviewed literature, radiographic signs in the OPG that indicate a relationship between the LTM and the inferior alveolar canal are considered a risk factor for nerve damage. These signs are darkening and deflection of the root, and diversion and interruption in the white line of the canal. In the majority of these studies, the routine use of CT is not justified, and is only recommended when radiographic signs appear in the OPG that demonstrate a direct anatomical relationship between the LTM and the canal. In the CT, the absence of cortical bone in the canal implies a contact between the root of the LTM and the canal, and is related with the presence of some radiographic signs in the OPG. Some studies demonstrate that despite the absence of cortical bone, the risk of lesion or exposure of the nerve during the extraction of LTM was low.