Laura G. Rico
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Laura G. Rico has a total of 587 co-authors. Here are the top co-authors by number of shared publications:
- Jordi Petriz
Functional Cytomics Lab, Germans Trias i Pujol Research Institute (IGTP), ICO‐Hospital Germans Trias i Pujol Universitat Autònoma de Barcelona Barcelona Spain
18 shared publications Jolene A. Bradford
9 shared publicationsMike D. Ward
Thermo Fisher Scientific Eugene Oregon USA
7 shared publications- Roser Salvia
Germans Trias i Pujol Research Institute (IGTP), Campus Can Ruti, Crta. de Can Ruti, Camí de les Escoles, S/n, 08916, Badalona, Spain; Department of Cellular Biology, Physiology and Immunology, Autonomous University of Barcelona (UAB), 08193, Cerdanyola del Vallès, Spain
7 shared publications Jordi Juncà
Hematology Laboratory Institut Català d'Oncologia, Hospital Germans Trias i Pujol, Functional cytomics‐IJC, Universitat Autònoma de Barcelona Badalona Spain
6 shared publicationsMichael D. Ward
Thermo Fisher Scientific Fort Collins Colorado USA
6 shared publications
Latest Publications
- 9 May 2024
- Published by Wiley in Cytometry Part A
- Vol. 105 (7) , 555-558
Bulk lysis procedures alter target cell population counts
To achieve high‐sensitivity cell measurements (5 cells) by flow cytometry (FCM), the minimum number of acquired cells must be considered and conventional immunophenotyping protocols fall short of these numbers. The bulk lysis (BL) assay is a standardized erythrocyte lysing approach that allows the analysis of the millions of cells required for high‐sensitivity measurable residual disease (MRD) detection. However, this approach has been associated with significant cell loss, along with potential over or underestimates of rare cells when using this method. The aim of this study was to evaluate bulk lysis protocols and compare them with minimal sample perturbation (MSP) protocols, which are reported to better preserve the native cellular state and avoid significant cell loss due to washing steps. To achieve this purpose, we first generated an MRD model by spiking fresh peripheral blood with K562 cells, stably expressing EGFP, at known percentages of EGFP positive cells to leukocytes. Samples were then prepared with BL and MSP protocols and analyzed using FCM. For all percentages of K562 cells established and evaluated, a significant decrease of this population was detected in BL samples compared with MSP samples, even at low K562 cell percentages. Significant decreases for non‐necrotic cells were also observed in BL samples relative to MSP samples. In conclusion, the evaluation of the potential effects of BL protocols in obtaining the final count is of great interest, especially for over‐ or under‐estimation of target cells, as in the case of measurable residual disease. Since conventional flow cytometry or minimal sample perturbation assays fall short in obtaining the minimum numbers required to reach high sensitivity measurements, significant efforts may be needed to improve bulk lysis solution reagents.
- 9 May 2024
- Published by Wiley in Cytometry Part A
- Vol. 105 (7) , 555-558
Bulk lysis procedures alter target cell population counts
To achieve high‐sensitivity cell measurements (5 cells) by flow cytometry (FCM), the minimum number of acquired cells must be considered and conventional immunophenotyping protocols fall short of these numbers. The bulk lysis (BL) assay is a standardized erythrocyte lysing approach that allows the analysis of the millions of cells required for high‐sensitivity measurable residual disease (MRD) detection. However, this approach has been associated with significant cell loss, along with potential over or underestimates of rare cells when using this method. The aim of this study was to evaluate bulk lysis protocols and compare them with minimal sample perturbation (MSP) protocols, which are reported to better preserve the native cellular state and avoid significant cell loss due to washing steps. To achieve this purpose, we first generated an MRD model by spiking fresh peripheral blood with K562 cells, stably expressing EGFP, at known percentages of EGFP positive cells to leukocytes. Samples were then prepared with BL and MSP protocols and analyzed using FCM. For all percentages of K562 cells established and evaluated, a significant decrease of this population was detected in BL samples compared with MSP samples, even at low K562 cell percentages. Significant decreases for non‐necrotic cells were also observed in BL samples relative to MSP samples. In conclusion, the evaluation of the potential effects of BL protocols in obtaining the final count is of great interest, especially for over‐ or under‐estimation of target cells, as in the case of measurable residual disease. Since conventional flow cytometry or minimal sample perturbation assays fall short in obtaining the minimum numbers required to reach high sensitivity measurements, significant efforts may be needed to improve bulk lysis solution reagents.
- Open Access
- 7 February 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (4) , 1994
Persistence of Chronic Lymphocytic Leukemia Stem-like Populations under Simultaneous In Vitro Treatment with Curcumin, Fludarabine, and Ibrutinib: Implications for Therapy Resistance
Leukemic stem cells (LSCs) possess similar characteristics to normal hematopoietic stem cells, including self-renewal capacity, quiescence, ability to initiate leukemia, and drug resistance. These cells play a significant role in leukemia relapse, persisting even after apparent remission. LSCs were first described in 1994 by Lapidot et al. Although they have been extensively studied in acute leukemia, more LSC research is still needed in chronic lymphocytic leukemia (CLL) to understand if reduced apoptosis in mature cells should still be considered as the major cause of this disease. Here, we provide new evidence suggesting the existence of stem-like cell populations in CLL, which may help to understand the disease as well as to develop effective treatments. In this study, we identified a potential leukemic stem cell subpopulation using the tetraploid CLL cell line I83. This subpopulation is characterized by diploid cells that were capable of generating the I83 tetraploid population. Furthermore, we adapted a novel flow cytometry analysis protocol to detect CLL subpopulations with stem cell properties in peripheral blood samples and primary cultures from CLL patients. These cells were identified by their co-expression of CD19 and CD5, characteristic markers of CLL cells. As previously described, increased alkaline phosphatase (ALP) activity is indicative of stemness and pluripotency. Moreover, we used this method to investigate the potential synergistic effect of curcumin in combination with fludarabine and ibrutinib to deplete this subpopulation. Our results confirmed the effectiveness of this ALP-based analysis protocol in detecting and monitoring leukemic stem-like cells in CLL. This analysis also identified limitations in eradicating these populations using in vitro testing. Furthermore, our findings demonstrated that curcumin significantly enhanced the effects of fludarabine and ibrutinib on the leukemic fraction, exhibiting synergistic effects (combination drug index, CDI 0.97 and 0.37, respectively). Our results lend support to the existence of potential stem-like populations in CLL cell lines, and to the idea that curcumin could serve as an effective adjuvant in therapies aimed at eliminating these populations and improving treatment efficacy.
- 7 February 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (4) , 1994
Open AccessPersistence of Chronic Lymphocytic Leukemia Stem-like Populations under Simultaneous In Vitro Treatment with Curcumin, Fludarabine, and Ibrutinib: Implications for Therapy Resistance
Leukemic stem cells (LSCs) possess similar characteristics to normal hematopoietic stem cells, including self-renewal capacity, quiescence, ability to initiate leukemia, and drug resistance. These cells play a significant role in leukemia relapse, persisting even after apparent remission. LSCs were first described in 1994 by Lapidot et al. Although they have been extensively studied in acute leukemia, more LSC research is still needed in chronic lymphocytic leukemia (CLL) to understand if reduced apoptosis in mature cells should still be considered as the major cause of this disease. Here, we provide new evidence suggesting the existence of stem-like cell populations in CLL, which may help to understand the disease as well as to develop effective treatments. In this study, we identified a potential leukemic stem cell subpopulation using the tetraploid CLL cell line I83. This subpopulation is characterized by diploid cells that were capable of generating the I83 tetraploid population. Furthermore, we adapted a novel flow cytometry analysis protocol to detect CLL subpopulations with stem cell properties in peripheral blood samples and primary cultures from CLL patients. These cells were identified by their co-expression of CD19 and CD5, characteristic markers of CLL cells. As previously described, increased alkaline phosphatase (ALP) activity is indicative of stemness and pluripotency. Moreover, we used this method to investigate the potential synergistic effect of curcumin in combination with fludarabine and ibrutinib to deplete this subpopulation. Our results confirmed the effectiveness of this ALP-based analysis protocol in detecting and monitoring leukemic stem-like cells in CLL. This analysis also identified limitations in eradicating these populations using in vitro testing. Furthermore, our findings demonstrated that curcumin significantly enhanced the effects of fludarabine and ibrutinib on the leukemic fraction, exhibiting synergistic effects (combination drug index, CDI 0.97 and 0.37, respectively). Our results lend support to the existence of potential stem-like populations in CLL cell lines, and to the idea that curcumin could serve as an effective adjuvant in therapies aimed at eliminating these populations and improving treatment efficacy.
- Open Access
- 10 February 2023
- Published by Elsevier in Acta Astronautica
- Vol. 210, 437-445
Effects of rapid gravity load changes on immunophenotyping and leukocyte function of human peripheral blood after parabolic flight
- 10 February 2023
- Published by Elsevier in Acta Astronautica
- Vol. 210, 437-445
Open AccessEffects of rapid gravity load changes on immunophenotyping and leukocyte function of human peripheral blood after parabolic flight
- 20 October 2022
- Published by Wiley in Cytometry Part A
- Vol. 103 (5) , 383-391
Erythrocyte lysing solutions have a detrimental effect in flow cytometric dendritic cell detection
Flow cytometry (FCM) enumeration of peripheral blood dendritic cells (PBDCs) is a minimally invasive procedure extremely useful for immunological studies. Numbers of PBDCs vary depending on age, lifestyle, or in pathologies like cancer, leukemia or immunodeficiencies. Conventional methods for PBDC identification by FCM involve red blood cell lysis using either formaldehyde or ammonium chloride‐based solutions. This specific procedure has been widely reported to cause a detrimental effect as well as an artifactual detection of target populations. Alternatively, minimal sample perturbation assays that avoid the use of erythrolytic solutions with centrifugation steps and preserve the native cellular state are simpler and more robust than conventional methods. In this study, we aimed to evaluate how conventional FCM assays can alter dendritic cell (DC) counting when compared with minimal sample perturbation protocols, in terms of absolute cell counting, percentage and stain index (SI) of PBDC subsets. We evaluated the use of three different erythrolytic solutions (CyLyse, OptiLyse C, and Pharm Lyse) on a series of n = 20 peripheral blood specimens for conventional and plasmacytoid DCs detection as well as for leukocyte and basophil detection. Our results showed a significant reduction of leukocytes and specifically, of DCs and basophils in terms of absolute number when using erythrolytic solutions. In conclusion, our study shows that PBDC counting is heavily affected when lysing solutions are used, indicating that these stellate‐shaped populations appear to be more labile.
- 20 October 2022
- Published by Wiley in Cytometry Part A
- Vol. 103 (5) , 383-391
Erythrocyte lysing solutions have a detrimental effect in flow cytometric dendritic cell detection
Flow cytometry (FCM) enumeration of peripheral blood dendritic cells (PBDCs) is a minimally invasive procedure extremely useful for immunological studies. Numbers of PBDCs vary depending on age, lifestyle, or in pathologies like cancer, leukemia or immunodeficiencies. Conventional methods for PBDC identification by FCM involve red blood cell lysis using either formaldehyde or ammonium chloride‐based solutions. This specific procedure has been widely reported to cause a detrimental effect as well as an artifactual detection of target populations. Alternatively, minimal sample perturbation assays that avoid the use of erythrolytic solutions with centrifugation steps and preserve the native cellular state are simpler and more robust than conventional methods. In this study, we aimed to evaluate how conventional FCM assays can alter dendritic cell (DC) counting when compared with minimal sample perturbation protocols, in terms of absolute cell counting, percentage and stain index (SI) of PBDC subsets. We evaluated the use of three different erythrolytic solutions (CyLyse, OptiLyse C, and Pharm Lyse) on a series of n = 20 peripheral blood specimens for conventional and plasmacytoid DCs detection as well as for leukocyte and basophil detection. Our results showed a significant reduction of leukocytes and specifically, of DCs and basophils in terms of absolute number when using erythrolytic solutions. In conclusion, our study shows that PBDC counting is heavily affected when lysing solutions are used, indicating that these stellate‐shaped populations appear to be more labile.
- 16 September 2022
- Published by Wiley in Cytometry Part A
- Vol. 103 (5) , 447-454
Accurate identification of cell doublet profiles: Comparison of light scattering with fluorescence measurement techniques
Doublet discrimination is usually based on pulse analysis of light scatter parameters. A combination of two pulse parameters (Area, A; Height, H; or Width, W) can be used to discriminate a pulse originated in a single cell from a pulse originated from cells stuck together. Fluorescence signals can be also used to discriminate aggregates, being essential to identify cells in the G2/M phase from doublets in the G0/G1 phase in cell cycle/DNA applications. The most used method combines FSC‐A versus FSC‐H, whereas other strategies combine FSC‐H versus FSC‐W, SSC‐H versus SSC‐A and SSC‐H versus SSC‐W. However, when studying activated or proliferating cells, scatter discrimination can be difficult. In this study, we have compared the use of light scattering with fluorescence measurement techniques for successful doublet discrimination for single cells. Effective use of FSC and SSC height, area and width are commonly used to eliminate aggregates. However, fluorescence‐based methods using viable DNA stains provide a good compromise between performance and accurate manual gating methods, especially for highly concentrated cell products and pathological specimens. Viable DNA dyes, such as Vybrant™ DyeCycle™ Violet stain or Hoechst 33342, can be used to detect nucleated cells in blood and in bone marrow, or to discriminate cell aggregates and debris based on no‐lyse no‐wash assays, where scatter degradation is a dominant component of the measured data, which increases with event rate.
- 16 September 2022
- Published by Wiley in Cytometry Part A
- Vol. 103 (5) , 447-454
Accurate identification of cell doublet profiles: Comparison of light scattering with fluorescence measurement techniques
Doublet discrimination is usually based on pulse analysis of light scatter parameters. A combination of two pulse parameters (Area, A; Height, H; or Width, W) can be used to discriminate a pulse originated in a single cell from a pulse originated from cells stuck together. Fluorescence signals can be also used to discriminate aggregates, being essential to identify cells in the G2/M phase from doublets in the G0/G1 phase in cell cycle/DNA applications. The most used method combines FSC‐A versus FSC‐H, whereas other strategies combine FSC‐H versus FSC‐W, SSC‐H versus SSC‐A and SSC‐H versus SSC‐W. However, when studying activated or proliferating cells, scatter discrimination can be difficult. In this study, we have compared the use of light scattering with fluorescence measurement techniques for successful doublet discrimination for single cells. Effective use of FSC and SSC height, area and width are commonly used to eliminate aggregates. However, fluorescence‐based methods using viable DNA stains provide a good compromise between performance and accurate manual gating methods, especially for highly concentrated cell products and pathological specimens. Viable DNA dyes, such as Vybrant™ DyeCycle™ Violet stain or Hoechst 33342, can be used to detect nucleated cells in blood and in bone marrow, or to discriminate cell aggregates and debris based on no‐lyse no‐wash assays, where scatter degradation is a dominant component of the measured data, which increases with event rate.
- 16 September 2022
- Published by Wiley in Cytometry Part A
- Vol. 103 (4) , 335-346
Impact of red blood cell lysing on rare event analysis
The challenges associated with analyzing rare cells are dependent on a series of factors, which usually require large numbers of cells per sample for successful resolution. Among these is determining the minimum number of total events needed to be acquired as defined by the expected frequency of the target cell population. The choice of markers that identify the target population, as well as the event rate and the number of aborted events/second, will also determine the statistically significant detection of rare cell events. Sample preparation is another important but often overlooked factor in rare cell analysis, and in this study we examine Poisson theory and methods to determine the effect of sample manipulation on rare cell detection. After verifying the applicability of this theory, we have evaluated the potential impact of red cell lysis on rare cell analysis, and how cell rarity can be underestimated or overestimated based on erythrolytic sensitivity or resistance of healthy leukocytes and pathological rare cells.
- 16 September 2022
- Published by Wiley in Cytometry Part A
- Vol. 103 (4) , 335-346
Impact of red blood cell lysing on rare event analysis
The challenges associated with analyzing rare cells are dependent on a series of factors, which usually require large numbers of cells per sample for successful resolution. Among these is determining the minimum number of total events needed to be acquired as defined by the expected frequency of the target cell population. The choice of markers that identify the target population, as well as the event rate and the number of aborted events/second, will also determine the statistically significant detection of rare cell events. Sample preparation is another important but often overlooked factor in rare cell analysis, and in this study we examine Poisson theory and methods to determine the effect of sample manipulation on rare cell detection. After verifying the applicability of this theory, we have evaluated the potential impact of red cell lysis on rare cell analysis, and how cell rarity can be underestimated or overestimated based on erythrolytic sensitivity or resistance of healthy leukocytes and pathological rare cells.
- Open Access
- 11 October 2021
- Published by Elsevier in STAR Protocols
- Vol. 2 (4) , 100883
Flow-cytometry-based protocols for human blood/marrow immunophenotyping with minimal sample perturbation
- 11 October 2021
- Published by Elsevier in STAR Protocols
- Vol. 2 (4) , 100883
Open AccessFlow-cytometry-based protocols for human blood/marrow immunophenotyping with minimal sample perturbation
- 1 May 2021
- Published by Wiley in Cytometry Part A
- Vol. 99 (5) , 503-510
A Novel Flow Cytometric Method to Study Cytotoxic Activity in Whole Blood Samples
For several decades, cell-mediated cytotoxicity has been measured using the(51)Cr release assay. This assay, however, has several drawbacks and flow cytometry has been used as an alternative to measure cytotoxic activity. Here, we present a quantitative method for cell-mediated cytotoxicity studies, preserving cellular function with minimal sample manipulation. Cytotoxic activity is simply and reproducibly measured as the ability of cytotoxic cells to lyse K562 target cells previously loaded with Calcein-AM vital stain. After spiking a known number of fluorescent viable K562 target cells into whole blood, cell mixtures are incubated for 2 h in a cell incubator and the remaining spiked cells are counted by flow cytometry. In order to discriminate nucleated cells, erythrocytes, and debris, unlysed whole blood is stained with a cell permeable DNA vital fluorescent dye. Cell-mediated lysis is measured by comparing target counts for different effector-to-target ratios. Since the cytotoxicity of these dyes is relatively low, this method can be broadly applied to studies of innate immune response to tumors and infections, especially where target-killing activity might be compromised by small volume samples or low frequency of cytotoxic cells. (c) 2020 International Society for Advancement of Cytometry
- 1 May 2021
- Published by Wiley in Cytometry Part A
- Vol. 99 (5) , 503-510
A Novel Flow Cytometric Method to Study Cytotoxic Activity in Whole Blood Samples
For several decades, cell-mediated cytotoxicity has been measured using the(51)Cr release assay. This assay, however, has several drawbacks and flow cytometry has been used as an alternative to measure cytotoxic activity. Here, we present a quantitative method for cell-mediated cytotoxicity studies, preserving cellular function with minimal sample manipulation. Cytotoxic activity is simply and reproducibly measured as the ability of cytotoxic cells to lyse K562 target cells previously loaded with Calcein-AM vital stain. After spiking a known number of fluorescent viable K562 target cells into whole blood, cell mixtures are incubated for 2 h in a cell incubator and the remaining spiked cells are counted by flow cytometry. In order to discriminate nucleated cells, erythrocytes, and debris, unlysed whole blood is stained with a cell permeable DNA vital fluorescent dye. Cell-mediated lysis is measured by comparing target counts for different effector-to-target ratios. Since the cytotoxicity of these dyes is relatively low, this method can be broadly applied to studies of innate immune response to tumors and infections, especially where target-killing activity might be compromised by small volume samples or low frequency of cytotoxic cells. (c) 2020 International Society for Advancement of Cytometry
- 22 September 2020
- Published by Wiley in Cytometry Part B: Clinical Cytometry
- Vol. 100 (4) , 519-530
Diagnostic performance of the ClearLLab 10C B cell tube
Introduction: Pre‐analytical and analytical errors can threaten the reliability of flow cytometry (FC) results. A potential solution to some of these is the use of dry, pre‐mixed antibodies, such as the ClearLLab 10C system. The purpose of the present study was to compare the diagnostic performance of the ClearLLab 10C B cell tube with that of our standard laboratory practice.Methods: We compared the diagnoses made with the ClearLLab 10C B cell tube (experimental strategy) with those made with standard laboratory practice (standard strategy). Samples were selected aiming for representation of the full spectrum of B cell disorders, with an emphasis on mature B cell malignancies, as well as healthy controls.Results: We included 116 samples (34 normal controls, 4 acute lymphoblastic leukemias, 54 mature lymphoproliferative disorders in peripheral blood and bone marrow, 3 myelomas, 6 bone marrow samples with involvement by lymphoma and 1 with elevated hematogone count, 14 lymph node samples, 1 cerebrospinal fluid, and 1 pleural effusion). There were two diagnostic errors (1.7%). The agreement between the two strategies in the percentage of CD19 cells and fluorescence intensity of CD5, CD19, CD20, CD200, and CD10 was very good.Conclusions: In this study, the ClearLLab 10C B cell tube performed similarly to our standard laboratory practice to diagnose and classify mature B cell malignancies.
- 22 September 2020
- Published by Wiley in Cytometry Part B: Clinical Cytometry
- Vol. 100 (4) , 519-530
Diagnostic performance of the ClearLLab 10C B cell tube
Introduction: Pre‐analytical and analytical errors can threaten the reliability of flow cytometry (FC) results. A potential solution to some of these is the use of dry, pre‐mixed antibodies, such as the ClearLLab 10C system. The purpose of the present study was to compare the diagnostic performance of the ClearLLab 10C B cell tube with that of our standard laboratory practice.Methods: We compared the diagnoses made with the ClearLLab 10C B cell tube (experimental strategy) with those made with standard laboratory practice (standard strategy). Samples were selected aiming for representation of the full spectrum of B cell disorders, with an emphasis on mature B cell malignancies, as well as healthy controls.Results: We included 116 samples (34 normal controls, 4 acute lymphoblastic leukemias, 54 mature lymphoproliferative disorders in peripheral blood and bone marrow, 3 myelomas, 6 bone marrow samples with involvement by lymphoma and 1 with elevated hematogone count, 14 lymph node samples, 1 cerebrospinal fluid, and 1 pleural effusion). There were two diagnostic errors (1.7%). The agreement between the two strategies in the percentage of CD19 cells and fluorescence intensity of CD5, CD19, CD20, CD200, and CD10 was very good.Conclusions: In this study, the ClearLLab 10C B cell tube performed similarly to our standard laboratory practice to diagnose and classify mature B cell malignancies.
- Open Access
- 16 June 2020
- Published by Wiley in Current Protocols in Cytometry
- Vol. 93 (1) , e76
Flow Cytometric Quantification of Granulocytic Alkaline Phosphatase Activity in Unlysed Whole Blood
Translational research has improved the diagnosis and follow‐up of hematological diseases and malignancies. However, some classical diagnostics used for research and clinical practice that have remain practically unchanged for decades may be better addressed through advances in flow cytometry technology, whereby more precise measurements may be implemented in a straightforward manner. The current method for semiquantitative analysis of granulocytic alkaline phosphatase (GAP) activity is still based on observer‐dependent color‐intensity classification. Here, we describe a novel strategy for flow cytometric quantification of GAP activity in which staining and analytical flow cytometry facilitate the detection and quantification of subpopulations of leukocytes with different GAP activities. Our experiments demonstrate the potential of flow cytometry as a simple and highly sensitive approach for measuring GAP activity in unlysed whole blood. Notably, a comparison of flow cytometry and enzyme cytochemistry techniques showed that enzyme activity scores were not similar, indicating that results needs to be interpreted with caution, given that the enzyme‐substrate binding affinities may differ, as well as the subjective evaluation of the intensity of the precipitated dye. © 2020 Wiley Periodicals LLC.Basic Protocol: Protocol preparation, sample acquisition, and gating strategy for flow cytometric identification of alkaline phosphatase activity in granulocytes from whole blood samplesSupport Protocol 1: Sample preparation for granulocyte alkaline phosphatase determination by flow cytometry using no‐lyse no‐wash methodsSupport Protocol 2: Data analysis and formula to calculate the GAP score
- 16 June 2020
- Published by Wiley in Current Protocols in Cytometry
- Vol. 93 (1) , e76
Open AccessFlow Cytometric Quantification of Granulocytic Alkaline Phosphatase Activity in Unlysed Whole Blood
Translational research has improved the diagnosis and follow‐up of hematological diseases and malignancies. However, some classical diagnostics used for research and clinical practice that have remain practically unchanged for decades may be better addressed through advances in flow cytometry technology, whereby more precise measurements may be implemented in a straightforward manner. The current method for semiquantitative analysis of granulocytic alkaline phosphatase (GAP) activity is still based on observer‐dependent color‐intensity classification. Here, we describe a novel strategy for flow cytometric quantification of GAP activity in which staining and analytical flow cytometry facilitate the detection and quantification of subpopulations of leukocytes with different GAP activities. Our experiments demonstrate the potential of flow cytometry as a simple and highly sensitive approach for measuring GAP activity in unlysed whole blood. Notably, a comparison of flow cytometry and enzyme cytochemistry techniques showed that enzyme activity scores were not similar, indicating that results needs to be interpreted with caution, given that the enzyme‐substrate binding affinities may differ, as well as the subjective evaluation of the intensity of the precipitated dye. © 2020 Wiley Periodicals LLC.Basic Protocol: Protocol preparation, sample acquisition, and gating strategy for flow cytometric identification of alkaline phosphatase activity in granulocytes from whole blood samplesSupport Protocol 1: Sample preparation for granulocyte alkaline phosphatase determination by flow cytometry using no‐lyse no‐wash methodsSupport Protocol 2: Data analysis and formula to calculate the GAP score