Markus Lentzen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Markus Lentzen has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
K. Urban
Institut für Festkörperforschung, Forschungszentrum Jülich GmbH, D-52425 Jülich, Germany
13 shared publications- Andreas Thust
Institut für Festkörperforschung, Forschungszentrum Jülich GmbH, D-52425 Jülich, Germany
6 shared publications Christopher R. Perrey
Department of Chemical Engineering and Materials Science, University of Minnesota, 421 Washington Ave S.E., 151 Amundson Hall, Minneapolis, MN 55455, USA
5 shared publicationsC. Barry Carter
University of Minnesota
4 shared publications- Lothar Houben
Weizmann Institute of Science
4 shared publications C.L. Jia
Institut für Festkörperforschung, Forschungszentrum Jülich GmbH, D-52425 Jülich, Germany
3 shared publications
Latest Publications
- Open Access
- 1 May 2025
- Published by IOP Publishing in New Journal of Physics
- Vol. 27 (5) , 058001
Comment on Reply to Comment on ‘Electromagnetic lensing using the Aharonov–Bohm effect’
Recently, Schreiber and Wolf (2024 New J. Phys. 26 118002) have questioned the validity of Stokes’ theorem, one of the most important tools in the theory of electromagnetism, by stating a counterexample. In this comment it is shown that the counterexample is invalid.
- 1 May 2025
- Published by IOP Publishing in New Journal of Physics
- Vol. 27 (5) , 058001
Open AccessComment on Reply to Comment on ‘Electromagnetic lensing using the Aharonov–Bohm effect’
Recently, Schreiber and Wolf (2024 New J. Phys. 26 118002) have questioned the validity of Stokes’ theorem, one of the most important tools in the theory of electromagnetism, by stating a counterexample. In this comment it is shown that the counterexample is invalid.
- Open Access
- 1 November 2024
- Published by IOP Publishing in New Journal of Physics
- Vol. 26 (11) , 118001
Comment on ‘Electromagnetic lensing using the Aharonov–Bohm effect’
Recently, Schreiber et al (2024 New J. Phys. 26 043012) have presented the theory of an electron lens acting through the Aharonov–Bohm effect in the field-free opening of a static toroidal magnetic field. In this Comment, three key results of this theory are shown to be incorrect due to six basic calculation errors. The errors are corrected, and three correspondingly modified key results are derived. These results are discussed with respect to the hypothetical lens effect and the underlying Aharonov–Bohm effect.
- 1 November 2024
- Published by IOP Publishing in New Journal of Physics
- Vol. 26 (11) , 118001
Open AccessComment on ‘Electromagnetic lensing using the Aharonov–Bohm effect’
Recently, Schreiber et al (2024 New J. Phys. 26 043012) have presented the theory of an electron lens acting through the Aharonov–Bohm effect in the field-free opening of a static toroidal magnetic field. In this Comment, three key results of this theory are shown to be incorrect due to six basic calculation errors. The errors are corrected, and three correspondingly modified key results are derived. These results are discussed with respect to the hypothetical lens effect and the underlying Aharonov–Bohm effect.
- 14 September 2022
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (1) , 418-426
Spin-Dependent Nonlinear Contrast Transfer in Transmission Electron Microscopy
In this study, the spin-dependent nonlinear contrast transfer in transmission electron microscopy is derived from the eikonal expansion of the Dirac equation. The transmission cross-coefficient of the standard imaging theory is amended by a spin-dependent factor, whose effect is investigated for single scattering in the object by an electrical field under polarized and unpolarized illumination, and it is illustrated with numerical results and plots for a kinetic energy of 80 keV. The resulting image displacement and image convolution increase with decreasing kinetic energy but are always smaller than a wavelength. General features of the cross-coefficient are discussed to identify favorable conditions for the measurement of the small spin effects, possibly in an unmodified instrument.
- 14 September 2022
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (1) , 418-426
Spin-Dependent Nonlinear Contrast Transfer in Transmission Electron Microscopy
In this study, the spin-dependent nonlinear contrast transfer in transmission electron microscopy is derived from the eikonal expansion of the Dirac equation. The transmission cross-coefficient of the standard imaging theory is amended by a spin-dependent factor, whose effect is investigated for single scattering in the object by an electrical field under polarized and unpolarized illumination, and it is illustrated with numerical results and plots for a kinetic energy of 80 keV. The resulting image displacement and image convolution increase with decreasing kinetic energy but are always smaller than a wavelength. General features of the cross-coefficient are discussed to identify favorable conditions for the measurement of the small spin effects, possibly in an unmodified instrument.
- Open Access
- 24 October 2019
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations and Advances
- Vol. 75 (6) , 861-865
Relativistic correction of atomic scattering factors for high-energy electron diffraction
Relativistic electron diffraction depends on linear and quadratic terms in the electric potential, the latter being neglected in the frequently used relativistically corrected Schrödinger equation. The quadratic electric potential term modifies atomic scattering amplitudes in particular for large-angle scattering and backscattering. The respective correction increases with increasing scattering angle, increasing atomic number and increasing kinetic energy. Conventional tabulations for electron scattering and its large-angle extrapolations can be amended in closed form by a universal correction based on the screened Coulomb potential squared.
- 24 October 2019
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations and Advances
- Vol. 75 (6) , 861-865
Open AccessRelativistic correction of atomic scattering factors for high-energy electron diffraction
Relativistic electron diffraction depends on linear and quadratic terms in the electric potential, the latter being neglected in the frequently used relativistically corrected Schrödinger equation. The quadratic electric potential term modifies atomic scattering amplitudes in particular for large-angle scattering and backscattering. The respective correction increases with increasing scattering angle, increasing atomic number and increasing kinetic energy. Conventional tabulations for electron scattering and its large-angle extrapolations can be amended in closed form by a universal correction based on the screened Coulomb potential squared.
- 1 January 2014
- Published by Elsevier in Ultramicroscopy
- Vol. 136, 201-210
No surprise in the first Born approximation for electron scattering
- 1 January 2014
- Published by Elsevier in Ultramicroscopy
- Vol. 136, 201-210
No surprise in the first Born approximation for electron scattering
- 4 March 2013
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 19 (2) , 310-318
Atomic-Scale Measurement of Structure and Chemistry of a Single-Unit-Cell Layer of LaAlO3 Embedded in SrTiO3
A single layer of LaAlO3 with a nominal thickness of one unit cell, which is sandwiched between a SrTiO3 substrate and a SrTiO3 capping layer, is quantitatively investigated by high-resolution transmission electron microscopy. By the use of an aberration-corrected electron microscope and by employing sophisticated numerical image simulation procedures, significant progress is made in two aspects. First, the structural as well as the chemical features of the interface are determined simultaneously on an atomic scale from the same specimen area. Second, the evaluation of the structural and chemical data is carried out in a fully quantitative way on the basis of the absolute image contrast, which has not been achieved so far in materials science investigations using high-resolution electron microscopy. Considering the strong influence of even subtle structural details on the electronic properties of interfaces in oxide materials, a fully quantitative interface analysis, which makes positional data available with picometer precision together with the related chemical information, can contribute to a better understanding of the functionality of such interfaces.
- 4 March 2013
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 19 (2) , 310-318
Atomic-Scale Measurement of Structure and Chemistry of a Single-Unit-Cell Layer of LaAlO3 Embedded in SrTiO3
A single layer of LaAlO3 with a nominal thickness of one unit cell, which is sandwiched between a SrTiO3 substrate and a SrTiO3 capping layer, is quantitatively investigated by high-resolution transmission electron microscopy. By the use of an aberration-corrected electron microscope and by employing sophisticated numerical image simulation procedures, significant progress is made in two aspects. First, the structural as well as the chemical features of the interface are determined simultaneously on an atomic scale from the same specimen area. Second, the evaluation of the structural and chemical data is carried out in a fully quantitative way on the basis of the absolute image contrast, which has not been achieved so far in materials science investigations using high-resolution electron microscopy. Considering the strong influence of even subtle structural details on the electronic properties of interfaces in oxide materials, a fully quantitative interface analysis, which makes positional data available with picometer precision together with the related chemical information, can contribute to a better understanding of the functionality of such interfaces.
- 1 January 2012
- Published by Elsevier in Ultramicroscopy
- Vol. 112 (1) , 15-21
Effective object planes for aberration-corrected transmission electron microscopy
- 1 January 2012
- Published by Elsevier in Ultramicroscopy
- Vol. 112 (1) , 15-21
Effective object planes for aberration-corrected transmission electron microscopy
- 30 April 2010
- Published by Elsevier in Ultramicroscopy
- Vol. 110 (5) , 517-526
Reconstruction of the projected electrostatic potential in high-resolution transmission electron microscopy including phenomenological absorption
- 30 April 2010
- Published by Elsevier in Ultramicroscopy
- Vol. 110 (5) , 517-526
Reconstruction of the projected electrostatic potential in high-resolution transmission electron microscopy including phenomenological absorption
- 28 September 2009
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 367 (1903) , 3735-3753
Negative spherical aberration ultrahigh-resolution imaging in corrected transmission electron microscopy
Aberration-corrected transmission electron microscopy allows us to image the structure of matter at genuine atomic resolution. A prominent role for the imaging of crystalline samples is played by the negative spherical aberration imaging (NCSI) technique. The physical background of this technique is reviewed. The especially high contrast observed under these conditions owes its origin to an enhancing combination of amplitude contrast due to electron diffraction channelling and phase contrast. A number of examples of the application of NCSI are reviewed in order to illustrate the applicability and the state-of-the-art of this technique.
- 28 September 2009
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 367 (1903) , 3735-3753
Negative spherical aberration ultrahigh-resolution imaging in corrected transmission electron microscopy
Aberration-corrected transmission electron microscopy allows us to image the structure of matter at genuine atomic resolution. A prominent role for the imaging of crystalline samples is played by the negative spherical aberration imaging (NCSI) technique. The physical background of this technique is reviewed. The especially high contrast observed under these conditions owes its origin to an enhancing combination of amplitude contrast due to electron diffraction channelling and phase contrast. A number of examples of the application of NCSI are reviewed in order to illustrate the applicability and the state-of-the-art of this technique.
- 1 January 2008
- Published by Elsevier
- p. 439-480
Chapter 11 Atomic-Resolution Aberration-Corrected Transmission Electron Microscopy
- 1 January 2008
- Published by Elsevier
- p. 439-480
Chapter 11 Atomic-Resolution Aberration-Corrected Transmission Electron Microscopy