Galina A. Petrushina
Galina A. Petrushina has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Andriy B. Vishnikin
Oles Honchar Dnipro National University
3 shared publications Ludmila P. Tsiganok
Oles Honchar Dnipropetrovsk National University, 72, Gagarin Ave., Dnipropetrovsk 49010
3 shared publications- Hana Sklenářová
Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Akademika Heyrovského 1203, 500 03 Hradec Králové, Czech Republic
2 shared publications - Petr Solich
Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Hradec Králové, Czech Republic
2 shared publications - Yaroslav Bazel
Department of Analytical Chemistry, P.J. Šafárik University in Košice, 04154 Košice, Slovakia
2 shared publications Andrey Vishnikin
Дніпровський національний університет імені Олеся Гончара
1 shared publication
Latest Publications
- Open Access
- 18 October 2021
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
- No. 3(9),p. 66-73
A potentiometric sensor for determination of hydrochinone
Гідрохінон має високу токсичність і тому його вміст повинен ретельно контролюватися. Розробка нових простих у виготовленні електродів з кращими аналітичними характеристиками, що мають невисоку вартість аналізу, є актуальною задачею. Для визначення гідрохінону нами запропонований електрод на основі графіту та композиційного матеріалу, що складається з поліуретану (полімерна матриця), графітового порошку (для підвищення електропровідності матеріалу) та 18-молібдодифосфату як реагенту. До переваг поліуретанів при їх використанні для модифікації електродів можна віднести високу адгезію полімеру до поверхні електроду внаслідок наявності великої кількості полярних груп. Крім того, його специфічні властивості забезпечують високі фізико-механічні властивості полімеру. Молібденовий гетерополіаніон структури Доусона 18-молібдодифосфат-аніон P2Mo18O626- є достатньо сильним окисником – реакція з деякими відновниками відбувається майже миттєво, відновлення протікає без деструкції P2Mo18O626-, що дозволяє використовувати його багаторазово. Взаємодія P2Mo18O626- з різними відновниками відбувається при різній кислотності розчинів. Таким чином, варіювання рН розчину дозволяє визначати декілька речовин у сумісній присутності. Для підвищення електропровідності додавали у композиційний матеріал дрібнодисперсний графітовий порошок. З оптимальним значенням опору є зразки із вмістом графітового порошку від 50% до 70%. P2Mo18O626- додавали у кількості 20 % до загальної маси композиційного матеріалу. Синтезованим полімерним композиційним матеріалом з поліуретану та P2Mo18O626- модифікували графітовий електрод. Визначені основні електрохімічні характеристики запропонованого електрода. Відновлення P2Mo18O626- гідрохіноном відбувається у нейтральному середовищі (рН 6). Час відгуку при різних концентраціях становить 8 хв (при температурі 19°С). У даного електрода відсутній «ефект пам’яті», відносна похибка становить від 1,3 до 1,9 %, а відхилення потенціалу – у межах 3-5 мВ. Межа визначення становить 2·10-5 моль/л. Вплив присутніх речовин оцінювали за допомогою константи селективності. Запропонований електрод має високу селективність по відношенню до великого числа неорганічних іонів. Для регенерації електрода його необхідно витримати у розчині 3%-вого гідроген пероксиду протягом 10 хвилин.
- 18 October 2021
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
- No. 3(9),p. 66-73
Open AccessA potentiometric sensor for determination of hydrochinone
Гідрохінон має високу токсичність і тому його вміст повинен ретельно контролюватися. Розробка нових простих у виготовленні електродів з кращими аналітичними характеристиками, що мають невисоку вартість аналізу, є актуальною задачею. Для визначення гідрохінону нами запропонований електрод на основі графіту та композиційного матеріалу, що складається з поліуретану (полімерна матриця), графітового порошку (для підвищення електропровідності матеріалу) та 18-молібдодифосфату як реагенту. До переваг поліуретанів при їх використанні для модифікації електродів можна віднести високу адгезію полімеру до поверхні електроду внаслідок наявності великої кількості полярних груп. Крім того, його специфічні властивості забезпечують високі фізико-механічні властивості полімеру. Молібденовий гетерополіаніон структури Доусона 18-молібдодифосфат-аніон P2Mo18O626- є достатньо сильним окисником – реакція з деякими відновниками відбувається майже миттєво, відновлення протікає без деструкції P2Mo18O626-, що дозволяє використовувати його багаторазово. Взаємодія P2Mo18O626- з різними відновниками відбувається при різній кислотності розчинів. Таким чином, варіювання рН розчину дозволяє визначати декілька речовин у сумісній присутності. Для підвищення електропровідності додавали у композиційний матеріал дрібнодисперсний графітовий порошок. З оптимальним значенням опору є зразки із вмістом графітового порошку від 50% до 70%. P2Mo18O626- додавали у кількості 20 % до загальної маси композиційного матеріалу. Синтезованим полімерним композиційним матеріалом з поліуретану та P2Mo18O626- модифікували графітовий електрод. Визначені основні електрохімічні характеристики запропонованого електрода. Відновлення P2Mo18O626- гідрохіноном відбувається у нейтральному середовищі (рН 6). Час відгуку при різних концентраціях становить 8 хв (при температурі 19°С). У даного електрода відсутній «ефект пам’яті», відносна похибка становить від 1,3 до 1,9 %, а відхилення потенціалу – у межах 3-5 мВ. Межа визначення становить 2·10-5 моль/л. Вплив присутніх речовин оцінювали за допомогою константи селективності. Запропонований електрод має високу селективність по відношенню до великого числа неорганічних іонів. Для регенерації електрода його необхідно витримати у розчині 3%-вого гідроген пероксиду протягом 10 хвилин.
- 1 January 2019
- Published by Taras Shevchenko National University of Kyiv in METHODS AND OBJECTS OF CHEMICAL ANALYSIS
- Vol. 14 (3) , 163-170
Simultaneous Kinetic Spectrophotometric Determination Of Ascorbic Acid And Cysteine With An Optical Probe By Mean Centering Of Ratio Kinetic Profiles Method
A procedure for simultaneous kinetic analysis of a binary mixture of ascorbic acid (Asc) and cysteine (Cys) was developed using the method of mean centering of ratio kinetic profiles. The method is based on the difference in the rate of reactions of Asc and Cys with the complex of iron(III) with o-phenanthroline at pH 7.05. The use of an optical probe simplifies the carrying out of kinetic measurements, allows to obtain highly reproducible (Sr=0.01-0.02) results, and significantly reduces the time of analysis. The method of mean centering of ratio kinetic profiles is superior to the H-Point standard addition method, since it does not require such a long measurement time and there is no restriction on the constancy of absorbance of one of the components. Asc and Cys can be determined in the concentration range from 1 to 10 mg/L. The method was successfully used to determine Asc and Cys in dietary supplements.
- 1 January 2019
- Published by Taras Shevchenko National University of Kyiv in METHODS AND OBJECTS OF CHEMICAL ANALYSIS
- Vol. 14 (3) , 163-170
Simultaneous Kinetic Spectrophotometric Determination Of Ascorbic Acid And Cysteine With An Optical Probe By Mean Centering Of Ratio Kinetic Profiles Method
A procedure for simultaneous kinetic analysis of a binary mixture of ascorbic acid (Asc) and cysteine (Cys) was developed using the method of mean centering of ratio kinetic profiles. The method is based on the difference in the rate of reactions of Asc and Cys with the complex of iron(III) with o-phenanthroline at pH 7.05. The use of an optical probe simplifies the carrying out of kinetic measurements, allows to obtain highly reproducible (Sr=0.01-0.02) results, and significantly reduces the time of analysis. The method of mean centering of ratio kinetic profiles is superior to the H-Point standard addition method, since it does not require such a long measurement time and there is no restriction on the constancy of absorbance of one of the components. Asc and Cys can be determined in the concentration range from 1 to 10 mg/L. The method was successfully used to determine Asc and Cys in dietary supplements.
- Open Access
- 2 December 2014
- Published by Oles Honchar Dnipropetrovsk National University in Вісник Дніпропетровського університету. Серія Хімія
- Vol. 22 (1) , 36-44
Спектрофотометричне визначення аскорбінової кислоти з використанням бісмутовмісного 18-молібдодифосфату
Reactions of formation and reduction of bismuth substituted 18-molybdophosphate (18-MBPC) with ascorbic acid (Asc) have been investigated. 18-MBPC is reduced by Asc in the presence of Bi(III) ions at the ratio of Asc:18-MBPC 1:1 and 2:1 with formation of, respectively, two- and four-electron reduced heteropoly blues. Their spectra are similar to the spectra of metalsubstituted heteropoly blues with Keggin structure and have an absorption maximum at 690 nm. Selective, rapid and simple method was developed for the determination of Asc. Benefits of using the 18-MPBC as analytical reagent are high sensitivity and rate of reduction rate, including the behavior in acid solutions. The limit of detection was of 2.6·10–6mol/l (l = 1 cm), and ε was of 1.15·104mol–1·l·cm–1.
- 2 December 2014
- Published by Oles Honchar Dnipropetrovsk National University in Вісник Дніпропетровського університету. Серія Хімія
- Vol. 22 (1) , 36-44
Open AccessСпектрофотометричне визначення аскорбінової кислоти з використанням бісмутовмісного 18-молібдодифосфату
Reactions of formation and reduction of bismuth substituted 18-molybdophosphate (18-MBPC) with ascorbic acid (Asc) have been investigated. 18-MBPC is reduced by Asc in the presence of Bi(III) ions at the ratio of Asc:18-MBPC 1:1 and 2:1 with formation of, respectively, two- and four-electron reduced heteropoly blues. Their spectra are similar to the spectra of metalsubstituted heteropoly blues with Keggin structure and have an absorption maximum at 690 nm. Selective, rapid and simple method was developed for the determination of Asc. Benefits of using the 18-MPBC as analytical reagent are high sensitivity and rate of reduction rate, including the behavior in acid solutions. The limit of detection was of 2.6·10–6mol/l (l = 1 cm), and ε was of 1.15·104mol–1·l·cm–1.
- 1 January 2011
- Published by Taylor & Francis in Analytical Letters
- Vol. 44 (1-3) , 514-527
Determination of Ascorbic Acid with Wells-Dawson Type Molybdophosphate in Sequential Injection System
Two-electron reduced heteropolyblue is formed very fast at pH 3.75–4.75 in the reaction between Dawson-type molybdophosphate HPA and ascorbic acid (AsA) (ϵ814 = 1.15 × 104 L · mol−1 cm−1). Simple, fast, and direct SIA method for AsA determination was developed. Under found optimal conditions, linear calibration curve was obtained over the range 3 × 10−6–3.5 × 10−4 mol L−1 AsA, and detection limit (3 s) was 1 × 10−6 mol L−1. The proposed SIA method has high sample throughput of 60 h−1 and small reagent consumption. The procedure was applied to the analysis of pharmaceuticals and juices.
- 1 January 2011
- Published by Taylor & Francis in Analytical Letters
- Vol. 44 (1-3) , 514-527
Determination of Ascorbic Acid with Wells-Dawson Type Molybdophosphate in Sequential Injection System
Two-electron reduced heteropolyblue is formed very fast at pH 3.75–4.75 in the reaction between Dawson-type molybdophosphate HPA and ascorbic acid (AsA) (ϵ814 = 1.15 × 104 L · mol−1 cm−1). Simple, fast, and direct SIA method for AsA determination was developed. Under found optimal conditions, linear calibration curve was obtained over the range 3 × 10−6–3.5 × 10−4 mol L−1 AsA, and detection limit (3 s) was 1 × 10−6 mol L−1. The proposed SIA method has high sample throughput of 60 h−1 and small reagent consumption. The procedure was applied to the analysis of pharmaceuticals and juices.