FSFarid Sadaka

Farid Sadaka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Farid Sadaka has a total of 180 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Validation of an EEG-based Delirium Monitor in the ICU

    by Chukwudi A. Onyemekwu, Suganya Karunakaran, Michelle Armenta Salas, Niall T. Prendergast, Kelly M. Toth, Melinda D. Miller, Sangil Lee, Baharan Kamousi, Malissa A. Mulkey, Farid Sadaka, et al.

    Purpose: Delirium affects around 40% of intensive care unit (ICU) patients and adversely affects survival, length of stay, and cognitive recovery. Despite this, implementation of systematic clinical delirium assessments is variable. We sought to validate a point-of-care electroencephalography (EEG)-based system (Ceribell, Inc.) for the detection of delirium in the ICU. Methods: In this multicenter, prospective cohort study, we monitored adult ICU patients with the Ceribell EEG system for 6-8 hours for a minimum of three days. Up to three times per day, expert clinicians assessed participants for delirium and research coordinators completed Confusion Assessment Method for the ICU (CAM-ICU) assessments, which we used to calculate CAM-ICU-7 severity scores. We compared expert clinician diagnoses with Ceribell EEG algorithm output using data from 30-minute periods surrounding each clinician assessment. Results: Among 225 participants analyzed (median age: 64 years, 60% male, 21% mechanically ventilated), expert clinicians performed 857 assessments and found 24% of participants were delirious during at least one assessment. The Ceribell EEG system detected delirium with a sensitivity of 81% (95% CI: 76% to 87%) and specificity of 81% (95% CI: 78% to 84%). The continuous Ceribell EEG system score correlated with CAM-ICU-7 delirium severity scores (bootstrapped median rho 0.58, IQR: 0.54-0.62, p <0.001). Conclusion: In a mixed adult ICU population, the Ceribell EEG system identified delirium with good sensitivity and specificity. Its continuous output was associated with delirium severity, highlighting its potential ability to characterize underlying physiological patterns across the clinical delirium spectrum.

  • Top Cited Papers
    Open Access

    Interpretability of an FDA-authorized AI/ML sepsis diagnostic tool improved by SHAP values

    by Gregory L Watson, Grace Staples, Robin Carver, Akhil Bhargava, Carlos López-Espina, Lee Schmalz, Farhan Ali, Peter S Antkowiak, Saleem Azad, Ramona Berghea, et al.

    Objectives: To assess the interpretability and acceptance of Shapley values for making artificial intelligence/machine learning (AI/ML) tools more transparent, interpretable, and useful to clinicians. Materials and Methods: Structured assessments were conducted with 30 clinicians (15 providers; 15 nurses; 8 assessments per clinician) to evaluate their ability to understand interventional Shapley Additive exPlanations (SHAP) values, a type of Shapley value that provides individualized variable importance scores and ascertain their perspective on SHAP value utility for the use of an AI/ML sepsis diagnostic. Participants were shown the diagnostic interface for real clinical scenarios with de-identified patient data with and without SHAP values. The primary outcomes were clinician ability to correctly interpret SHAP values and clinician self-reported improvement in their understanding of how the AI/ML algorithm produced its result. Results: Participants correctly interpreted SHAP values in 235 of 240 assessments (98%; CI, 95%-99%) and reported SHAP values improved their understanding of how the algorithm produced its result in every case (240/240; 100%; CI, 99%-100%). Participants were unanimous (30/30) in preferring the interface with SHAP values over the interface without. Discussion: Clinician participants strongly preferred the device interface with SHAP values, were unanimous in reporting SHAP values improved their understanding of the AI/ML diagnostic, and scored nearly perfectly when asked to interpret SHAP values. Conclusion: These results suggest health care providers value transparency into AI/ML algorithms designed for clinical use, and that Shapley values are a useful approach to providing that transparency, which in turn may improve tool adoption and clinical utility.


  • Top Cited Papers

    FDA-Authorized AI/ML Tool for Sepsis Prediction: Development and Validation

    by Akhil Bhargava, Carlos López-Espina, Lee Schmalz, Shah Khan, Gregory L. Watson, Dennys Urdiales, Lincoln Updike, Niko Kurtzman, Alon Dagan, Amanda Doodlesack, et al.


  • 234: Predicting Mortality in COVID-19: Comparison of APACHE IV, MEWS, and mSOFA

    by Ahmed Alsaei, Steve Onyambu, Pamir Mateen, Muhammad Ali Javed, Christopher Coriasso, Azam Khan, Farid Sadaka


  • 190: Predicting Mortality in COVID-19: Comparison of Novel Score With APACHE IV

    by Steve Onyambu, Ahmed Alsaei, Pamir Mateen, Muhammad Ali Javed, Christopher Coriasso, Azam Khan, Farid Sadaka


  • Open Access

    Thrombocytopenia: A possible side effect of apixaban

    by Farid Sadaka

    Apixaban is becoming more frequently prescribed for stroke prevention in patients with atrial fibrillation, and even rare side effects such as thrombocytopenia should be considered and monitored closely.


  • Ascorbic Acid, Thiamine, and Steroids in Septic Shock: Propensity Matched Analysis

    by Farid Sadaka, Justin Grady, Nikhil Organti, Bhargavi Donepudi, Matthew Korobey, David Tannehill, Jacklyn O’bRien

    We aimed to study the use of ascorbic acid, thiamine, and steroids (ATS) in patients with septic shock (SS). Data on 62 patients with SS were collected from Acute Physiologic and Chronic Health Evaluation (APACHE) Outcome database and medical records. The ATS group received full doses of intravenous (IV) ATS (ascorbic acid [1.5 g every 6 hours for 4 days], hydrocortisone [50 mg every 6 hours for 7 days], and thiamine [200 mg every 12 hours for 4 days]). Data included age, gender, APACHE III, acute physiologic score (APS), mechanical ventilation (MV), lactic acid (LA), serum creatinine (Cr), duration of vasopressors (VP, days, median: interquartile ranges [IQR]: [Q1, Q3]), MV-free days (median: IQR [Q1-Q3]), percentage of patients requiring renal replacement therapy (RRT) for acute kidney injury (AKI), and mortality. Propensity analysis was used to match patients on age, gender, MV, APACHE III, APS, LA, and Cr. The ATS group had longer duration of VP (4.5: 4.0-6.0 vs 2.0: 1.0-2.0, P = .001), similar RRT for AKI (26% vs 29%, P = .8), similar MV-free days (10.2: 5.0-15.0 vs 10.2: 1.6-18.0, P > .9), lower intensive care unit mortality (9.6% vs 42%, P = .004), and a trend toward lower hospital mortality (29% vs 45%, P = .2) compared to the NO ATS group. The use of IV ascorbic acid, thiamine, and hydrocortisone might be beneficial in patients with SS.


  • Open Access

    Intrathoracic pressure regulation therapy applied to ventilated patients for treatment of compromised cerebral perfusion from brain injury

    by Anja K. Metzger, Nicolas Segal, Dai Wai Olson, Stephen A. Figueroa, Farid G. Sadaka, Catherine A. Krause, James R. Homuth, Nathaniel T. Burkhart, Robert T. Neumann, Keith G. Lurie, et al.

    Reducing intrathoracic pressure in the setting of compromised cerebral perfusion due to acute brain injury has been associated with reduced intracranial pressure and enhanced cerebral perfusion pressure and blood flow in animals. Noninvasive active intrathoracic pressure regulation lowers intrathoracic pressure, increases preload, reduces the volume of venous blood and cerebral spinal fluid in the skull, and enhances cerebral blood flow. We examined the feasibility of active intrathoracic pressure regulation therapy in patients with brain injury. We hypothesized that active intrathoracic pressure regulation therapy would be associated with lowered intracranial pressure and increased cerebral perfusion pressure in these patients. At three institutions, active intrathoracic pressure regulation therapy (CirQlator™, ZOLL) was utilized for 2 consecutive hours in five mechanically ventilated patients with brain injury. A 30-minute interval was used to collect baseline data and determine persistence of effects after device use. End-tidal carbon dioxide was controlled by respiratory rate changes during device use. The intracranial pressure, mean arterial pressure, and cerebral perfusion pressure were recorded at 5-minute intervals throughout all three periods of the protocol. Results for each interval are reported as mean and standard deviation. Intracranial pressure was decreased in all five patients by an average of 21% during (15 ± 4 mmHg) compared to before active intrathoracic pressure regulation (19 ± 4) (p = 0.005). This effect on intracranial pressure (15 ± 6) was still present in four of the five patients 30 minutes after therapy was discontinued (p = 0.89). As a result, cerebral perfusion pressure was 16% higher during (81 ± 10) compared to before active intrathoracic pressure regulation (70 ± 14) (p = 0.04) and this effect remained present 30 minutes after therapy was discontinued. No adverse events were reported. These data support the notion that active intrathoracic pressure regulation, in this limited evaluation, can successfully augment cerebral perfusion by lowering intracranial pressure and increasing mean arterial pressure in patients with mild brain injury. The measured effects were immediate on administration of the therapy and persisted to some degree after the therapy was terminated.


  • Open Access

    Do All Acute Stroke Patients Receiving tPA Require ICU Admission?

    by Farid Sadaka, Amar Jadhav, Jacklyn O’brien, Steven Trottier

    Do All Acute Stroke Patients Receiving tPA Require ICU Admission?