YPYuriy A. Pirogov

Yuriy A. Pirogov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yuriy A. Pirogov has a total of 302 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    STAMM3D: Dataset and Benchmark for Non-Deformable 3D Image Registration in Multiple Modalities

    by Leonid Koliaskin, Danil Kazimirov, Oleg Bugai, Marat Gilmanov, Dmitry Polevoy, Marina Chukalina, Dmitrii Lebedev, Mikhail Gulyaev, Nikolai Anisimov, Yury Pirogov, et al.

    Volumetric image registration is a fundamental computer vision problem with broad applications across fields such as medicine, biological and cellular imaging, geoscience, and cultural heritage preservation. The 3D image registration problem is commonly divided into monomodal and multimodal registration problems, depending on whether the images originate from the same or different imaging modalities. Monomodal 3D image registration is a well-studied problem with established state-of-the-art methods and a range of widely recognized benchmarks. In contrast, multimodal 3D image registration remains an open problem despite numerous developed registration methods. A key challenge is that existing open-access multimodal benchmark datasets are scarce and limited in modality diversity, which constrains registration generalization across modalities. As a result, most multimodal registration methods remain tuned to specific modalities and narrow domains of objects. This leads to the need to redevelop multimodal registration tools for each specific task, and no universal solution exists. To approach the task of universal multimodal image registration, in this paper we introduce STAMM3D (Similarity Transform Alignment of Multimodal 3D images)—a new benchmark for multimodal registration that includes an open-access dataset of 22 3D images of rigid medical, biological, and non-biomedical objects and provides an automated Target Registration Error-based evaluation framework. The publicly availablebenchmark offers a high-resolution dataset with multiple domains of objects and a wide range of different modalities deliberately chosen to test and compare universality and generalization properties of the registration methods. The focus of the dataset is on non-deformable image registration since it directly affects the quality of image fusion, whether used independently or within multi-stage deformable registration pipelines. Using STAMM3D, we benchmark several widespread, multipurpose, open-source non-deformable registration tools (NiftyReg, SimpleITK, SIFT3D, DeedsBCV), establishing a solid performance baseline. While existing tools provide a solid baseline, the comparison results suggest that additional work is needed to improve the robustness of non-deformable registration techniques.

  • Gadolinium-doped carbon nanoparticles: coordination, spectroscopic characterization and magnetic resonance relaxivity

    by Nikita D. Mitiushev, Daria U. Musaeva, Daniil A. Artemov, Alexander V. Syuy, Olga S. Pavlova, Yury A. Pirogov, Eugene N. Kabachkov, Alexandr V. Fionov, Vladimir G. Kytin, Elizaveta A. Konstantinova, et al.

    Gd-doped carbon nanoparticles are characterized spectroscopically to reveal new possibilities for controlling the optical and MRI contrast properties of these nanoparticles for biomedical applications.


  • Deep-Learning Segmentation of Bleomycin-Induced Pulmonary Fibrosis in Rats Using U-Net 3 + by 3D UTE-MRI

    by T. V. Taran, O. S. Pavlova, M. V. Gulyaev, E. V. Ivanov, Y. A. Pirogov

  • Automated Image Registration and Perfusion Sorting Algorithms for PREFUL MRI

    by Timofei V. Taran, Olga S. Pavlova, Mikhail V. Gulyaev, Dmitry S. Dmitriev, Aleksandr G. Pistrak, Kirill N. Ryabikov, Viktor P. Tarasov, Yury A. Pirogov


  • Open Access

    Gadolinium-Doped Carbon Nanoparticles with Red Fluorescence and Enhanced Proton Relaxivity as Bimodal Nanoprobes for Bioimaging Applications

    by Dariia U. Musaeva, Alexey N. Kopylov, Alexander V. Syuy, Valentyn S. Volkov, Nikita D. Mitiushev, Olga S. Pavlova, Yury A. Pirogov, Andrey N. Baranov, Victor Yu. Timoshenko

    Carbon-based nanoparticles (CNPs) have demonstrated great potential in biomedical applications because of their unique physical and chemical properties, and excellent biocompatibility. Herein, we have studied two types of CNPs with gadolinium (Gd) impurities (Gd-CNPs), which were prepared by microwave synthesis (MWS) and hydrothermal synthesis (HTS), for potential applications as photoluminescent (PL) labels and contrast agents in magnetic resonance imaging (MRI). The prepared Gd-CNPs were investigated by means of transmission electron microscopy (TEM), Fourier-transform infrared spectroscopy, UV–visible absorption spectroscopy, and magnetic-resonance relaxometry, which allowed us to reveal specific features and functional properties of the prepared samples. While the TEM data showed similar size distributions of both types of Gd-CNPs with mean sizes of 4–5 nm, the optical absorption spectroscopy showed higher absorption in the visible spectral region and stronger PL in the red and near-infrared (NIR) spectral regions for the MWS samples in comparison with those prepared by HTS. Under green light excitation the former samples exhibited the bright red-NIR PL with quantum efficiency of the order of 10%. The proton relaxometry measurements demonstrated that the HTS samples possessed longitudinal and transverse relaxivities of about 42 and 70 mM−1s−1, whereas the corresponding values for the MWS samples were about 8 and 13 mM−1s−1, respectively. The obtained results can be useful for the selection of appropriate synthesis conditions for carbon-based nanoparticles for bimodal bioimaging applications.


  • MRI of Inanimate Objects Using Fluorine-Containing Liquid

    by Nikolay V. Anisimov, Lev L. Gervits, Arina A. Tarasova, Ivan A. Usanov, Yury A. Pirogov


  • High‐Contrast and Fast‐Removable 19F‐MRI Labels with Perfluoro‐tert‐Butyl Substituents

    by Lev L. Gervits, Andrey L. Sigan, Alina A. Markova, Mikhail V. Gulyaev, Olga S. Pavlova, Ratislav M. Ozhiganov, Yury A. Pirogov

    19F MRI is a unique technique for tracking and quantifying the indicator (19F‐MRI label) in vivo without the use of ionizing radiation. Here we report new 19F‐MRI labels, which are compounds with perfluoro‐tert‐butyl groups: 1,2‐bis(perfluoro‐tert‐butoxy)ethane (C10F18H4O2) and 1,3‐bis(perfluoro‐tert‐butyl)propane (C11F18H6). Both substances contain 18 equivalent 19F atoms, constituting 68.67 % and 71.25 % of the molecule, respectively. The emulsions with 19F molecules were prepared and used in 19F MRI studies in laboratory rats in vivo. The substances demonstrated high contrast properties, good biological inertness and the ability to be rapidly eliminated from the body. We showed that at a dose of 0.34 mg/g of body weight in rats, the time for complete elimination of C10F18H4O2 and C11F18H6 is ∼30 days. The results turned out to be promising for the use of the presented compounds in 19F MRI applications, especially since they are quite easy to synthesize.


  • Sodium MRI of Fish on 0.5T Clinical Scanner

    by N. V. Anisimov, V. V. Shakhparonov, A. V. Romanov, A. A. Tarasova, I. A. Usanov, O. S. Pavlova, M. V. Gulyaev, Yu. A. Pirogov


  • Open Access

    Synergetic Enhancement of Tumor Double-Targeted MRI Nano-Probe

    by Nikita Yabbarov, Elena Nikolskaya, Maria Sokol, Mariia Mollaeva, Margarita Chirkina, Irina Seregina, Mikhail Gulyaev, Yury Pirogov, Rem Petrov

    The conventional targeted delivery of chemotherapeutic and diagnostic agents utilizing nanocarriers is a promising approach for cancer theranostics. Unfortunately, this approach often faces hindered tumor access that decreases the therapeutic index and limits the further clinical translation of a developing drug. Here, we demonstrated a strategy of simultaneously double-targeting the drug to two distinct cites of tumor tissue: the tumor endothelium and cell surface receptors. We used fourth-generation polyamideamine dendrimers modified with a chelated Gd and functionalized with selectin ligand and alpha-fetoprotein receptor-binding peptide. According to the proposed strategy, IELLQAR peptide promotes the conjugate recruitment to the tumor inflammatory microenvironment and enhances extravasation through the interaction of nanodevice with P- and E-selectins expressed by endothelial cells. The second target moiety—alpha-fetoprotein receptor-binding peptide—enhances drug internalization into cancer cells and the intratumoral retention of the conjugate. The final conjugate contained 18 chelated Gd ions per dendrimer, characterized with a 32 nm size and a negative surface charge of around 18 mV. In vitro contrasting properties were comparable with commercially available Gd-chelate: r1 relaxivity was 3.39 for Magnevist and 3.11 for conjugate; r2 relaxivity was 5.12 for Magnevist and 4.81 for conjugate. By utilizing this dual targeting strategy, we demonstrated the increment of intratumoral accumulation, and a remarkable enhancement of antitumor effect, resulting in high-level synergy compared to monotargeted conjugates. In summary, the proposed strategy utilizing tumor tissue double-targeting may contribute to an enhancement in drug and diagnostic accumulation in aggressive tumors.