Muhammad Shoaib
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Muhammad Shoaib has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Mohammad Tariq Jan
Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, Perak, Malaysia
5 shared publicationsAsif Mirza
Department of Electrical & Electronic Engineering, Universiti Teknologi PETRONAS. Bandar Seri Iskandar, 31750 Tronoh, Perak Malaysia
3 shared publicationsNoohul Basheer Zain Ali
Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, Perak, Malaysia
3 shared publicationsNor Hisham Hamid
Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, Bandar Seri Iskandar, Perak, Malaysia
3 shared publicationsFarooq Ahmad
2 shared publications- John Ojur Dennis
Department of Fundamental and Applied Sciences, Universiti Teknologi PETRONAS, Seri Iskandar, Perak 32610, Malaysia
2 shared publications
Latest Publications
- 9 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (19) , 6279-6294
Effects of Crack Faults on the Dynamics of Piezoelectric Cantilever-Based MEMS Sensor
The presence of cracks on the surface of MEMS microelectromechanical system (MEMS) devices affects their functional parameter, such as resonance frequency. Overtime, these cracks may cause the devices’ failure. Therefore, it is important to identify the symptoms of the cracks presence so that the affected devices can be removed/bin-out before delivering to the customers thus avoiding failure during applications of these devices. In this paper, we present a predictive and quantitative fault modeling approach using the linear time invariant (LTI) technique for a piezoelectric cantilever-based sensor. The analytical fault model is developed by correlating single edge, double edge, and surface cracks with the resonance frequency of the cantilever. The Simulink is utilized to design the LTI-based faulty device by integrating the dynamic equations associated to actuation and sensing mechanisms of the device under study. The model is validated by comparing it with the finite element method model containing the same design parameters, using the COMSOL Multiphysics. We observed that the presence of cracks at any location on the surface of the device stimulates the amplitude that causes decrease in its resonance frequency. The increase in the amplitude of vibration due to the presence of cracks is electrically sensed by the piezoresistive mechanism. Finally, the fault detection methodology is presented by using the Stateflow technique. We found that the proposed techniques can be significant to study the faulty behavior of the MEMS devices.
- 9 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (19) , 6279-6294
Effects of Crack Faults on the Dynamics of Piezoelectric Cantilever-Based MEMS Sensor
The presence of cracks on the surface of MEMS microelectromechanical system (MEMS) devices affects their functional parameter, such as resonance frequency. Overtime, these cracks may cause the devices’ failure. Therefore, it is important to identify the symptoms of the cracks presence so that the affected devices can be removed/bin-out before delivering to the customers thus avoiding failure during applications of these devices. In this paper, we present a predictive and quantitative fault modeling approach using the linear time invariant (LTI) technique for a piezoelectric cantilever-based sensor. The analytical fault model is developed by correlating single edge, double edge, and surface cracks with the resonance frequency of the cantilever. The Simulink is utilized to design the LTI-based faulty device by integrating the dynamic equations associated to actuation and sensing mechanisms of the device under study. The model is validated by comparing it with the finite element method model containing the same design parameters, using the COMSOL Multiphysics. We observed that the presence of cracks at any location on the surface of the device stimulates the amplitude that causes decrease in its resonance frequency. The increase in the amplitude of vibration due to the presence of cracks is electrically sensed by the piezoresistive mechanism. Finally, the fault detection methodology is presented by using the Stateflow technique. We found that the proposed techniques can be significant to study the faulty behavior of the MEMS devices.
- 1 August 2016
- Published by Elsevier in Microelectronics Reliability
- Vol. 63, 82-89
Experimental investigation of temperature and relative humidity effects on resonance frequency and quality factor of CMOS-MEMS paddle resonator
- 1 August 2016
- Published by Elsevier in Microelectronics Reliability
- Vol. 63, 82-89
Experimental investigation of temperature and relative humidity effects on resonance frequency and quality factor of CMOS-MEMS paddle resonator
- 1 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Effects of edge cracks on the dynamics of piezoelectric cantilever based MEMS sensor
This paper presents edge crack fault modeling for piezoelectric cantilever based MEMS sensor using LTI (linear time invariant) technique. Frequency fault model is developed to analyze the dynamic behavior of the device in term of displacement, frequency and output electrical response. First an analytical model is developed that shows the electromechanical coupling of the device. Crack function along with the dynamic mass is used to develop the resonance frequency of cracked cantilever. Then LTI model of faulty device is developed by integrating the analytical equations using Simulink tool. The LTI model is validated by comparing its results with the FEM design using same design parameters using COMSOL tool. The results shows that resonance frequency of the device is changed by changing the crack size and its location in the cantilever structure.
- 1 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Effects of edge cracks on the dynamics of piezoelectric cantilever based MEMS sensor
This paper presents edge crack fault modeling for piezoelectric cantilever based MEMS sensor using LTI (linear time invariant) technique. Frequency fault model is developed to analyze the dynamic behavior of the device in term of displacement, frequency and output electrical response. First an analytical model is developed that shows the electromechanical coupling of the device. Crack function along with the dynamic mass is used to develop the resonance frequency of cracked cantilever. Then LTI model of faulty device is developed by integrating the analytical equations using Simulink tool. The LTI model is validated by comparing its results with the FEM design using same design parameters using COMSOL tool. The results shows that resonance frequency of the device is changed by changing the crack size and its location in the cantilever structure.
- 1 February 2016
- Published by Elsevier in Microelectronics Reliability
- Vol. 57, 64-70
Temperature dependent Young's modulus and quality factor of CMOS-MEMS resonator: Modelling and experimental approach
- 1 February 2016
- Published by Elsevier in Microelectronics Reliability
- Vol. 57, 64-70
Temperature dependent Young's modulus and quality factor of CMOS-MEMS resonator: Modelling and experimental approach
- 25 January 2016
- Published by Springer Nature in Analog Integrated Circuits and Signal Processing
- Vol. 88 (1) , 1-11
Frequency and displacement analysis of electrostatic cantilever-based MEMS sensor
- 25 January 2016
- Published by Springer Nature in Analog Integrated Circuits and Signal Processing
- Vol. 88 (1) , 1-11
Frequency and displacement analysis of electrostatic cantilever-based MEMS sensor
- Open Access
- 1 January 2016
- Published by Wiley in Journal of Sensors
- Vol. 2016, 1-14
A Review on Key Issues and Challenges in Devices Level MEMS Testing
The present review provides information relevant to issues and challenges in MEMS testing techniques that are implemented to analyze the microelectromechanical systems (MEMS) behavior for specific application and operating conditions. MEMS devices are more complex and extremely diverse due to the immersion of multidomains. Their failure modes are distinctive under different circumstances. Therefore, testing of these systems at device level as well as at mass production level, that is, parallel testing, is becoming very challenging as compared to the IC test, because MEMS respond to electrical, physical, chemical, and optical stimuli. Currently, test systems developed for MEMS devices have to be customized due to their nondeterministic behavior and complexity. The accurate measurement of test systems for MEMS is difficult to quantify in the production phase. The complexity of the device to be tested required maturity in the test technique which increases the cost of test development; this practice is directly imposed on the device cost. This factor causes a delay in time-to-market.
- 1 January 2016
- Published by Wiley in Journal of Sensors
- Vol. 2016, 1-14
Open AccessA Review on Key Issues and Challenges in Devices Level MEMS Testing
The present review provides information relevant to issues and challenges in MEMS testing techniques that are implemented to analyze the microelectromechanical systems (MEMS) behavior for specific application and operating conditions. MEMS devices are more complex and extremely diverse due to the immersion of multidomains. Their failure modes are distinctive under different circumstances. Therefore, testing of these systems at device level as well as at mass production level, that is, parallel testing, is becoming very challenging as compared to the IC test, because MEMS respond to electrical, physical, chemical, and optical stimuli. Currently, test systems developed for MEMS devices have to be customized due to their nondeterministic behavior and complexity. The accurate measurement of test systems for MEMS is difficult to quantify in the production phase. The complexity of the device to be tested required maturity in the test technique which increases the cost of test development; this practice is directly imposed on the device cost. This factor causes a delay in time-to-market.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Frequency analysis of electrostatic cantilever-based MEMS sensor
This paper presents an analytical approach to model the dynamic behavior and predict the frequency of electrostatic cantilever based MEMS (Microelectromechanical system) sensor for mass detection. The concept of dynamic mass is used to formulate the resonance frequency in damped and undamped medium. In the modeling, electrostatic force is coupled with the bending moment of cantilever to produce actuation at a resonance frequency. Mass of blood cells is used as an external load on the cantilever which results in shift in resonance frequency. This shift due to additional mass is sensed by the piezoresistive mechanism. The device analytical model is integrated using Simulink tool to study the dynamic behavior. The same device is then designed using COMSOL tool and FEM analysis is performed. The analytical results are compared with the simulated results.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Frequency analysis of electrostatic cantilever-based MEMS sensor
This paper presents an analytical approach to model the dynamic behavior and predict the frequency of electrostatic cantilever based MEMS (Microelectromechanical system) sensor for mass detection. The concept of dynamic mass is used to formulate the resonance frequency in damped and undamped medium. In the modeling, electrostatic force is coupled with the bending moment of cantilever to produce actuation at a resonance frequency. Mass of blood cells is used as an external load on the cantilever which results in shift in resonance frequency. This shift due to additional mass is sensed by the piezoresistive mechanism. The device analytical model is integrated using Simulink tool to study the dynamic behavior. The same device is then designed using COMSOL tool and FEM analysis is performed. The analytical results are compared with the simulated results.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Study of nonlinear pull-in voltage effects in electrostatic cantilever-based MEMS sensors
This paper presents new investigations to improve dynamic behavior of electrostatic cantilever based MEMS sensors by reducing pull-in voltage nonlinearity. It is believe that pull-in voltage is one of the major factors to generate pull-in force that induces parasitic pull-in frequency as a result the behavior of MEMS sensor become nonlinear. The dynamic behavior of the device is modeled under the pull-in force. The results of numerical simulation of nonlinear model show that pull-in nonlinear force participate to generate an opposite parasitic pull-in frequency. The effect of dielectric on pull-in force and pull-in frequency is analyzed by varying the thickness of dielectric layer at different applied. It is found that increasing the dielectric thickness reduces the pull-in nonlinear factors. Simulink tool is also used to model the schematic of complete electromechanical actuation and sensing of the device. The results show that output current of the device depends on the thickness of dielectric layer.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Study of nonlinear pull-in voltage effects in electrostatic cantilever-based MEMS sensors
This paper presents new investigations to improve dynamic behavior of electrostatic cantilever based MEMS sensors by reducing pull-in voltage nonlinearity. It is believe that pull-in voltage is one of the major factors to generate pull-in force that induces parasitic pull-in frequency as a result the behavior of MEMS sensor become nonlinear. The dynamic behavior of the device is modeled under the pull-in force. The results of numerical simulation of nonlinear model show that pull-in nonlinear force participate to generate an opposite parasitic pull-in frequency. The effect of dielectric on pull-in force and pull-in frequency is analyzed by varying the thickness of dielectric layer at different applied. It is found that increasing the dielectric thickness reduces the pull-in nonlinear factors. Simulink tool is also used to model the schematic of complete electromechanical actuation and sensing of the device. The results show that output current of the device depends on the thickness of dielectric layer.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Influence of crack growths on the performances of cantilever based MEMS devices: Design and simulations
There is a great need to design experimental setup to deal with the fundamental material issues in MEMS. Cantilever being the active part of MEMS is modeled using COMSOL Multiphysics. The model is simulated for small cracks ranging from Nano to Micro-meter. The cracks are produced at the anchor of MEMS device subjected to variations in Eigen frequencies, Stress levels and Tip displacements of cantilever beam and is measured in association with crack growths. These factors are simulated in order to predict the ultimate lifetime in the form of total number of cycles to failure in association with variations in applied stress levels and with the help of Statistical distribution and Paris's law. The Paris's law is utilized by integrating it between the upper and lower limits (crack sizes) that results in predicting the useful lifetime of the cantilever based MEMS device. The simulated results show that at resonance frequency the probability of crack growth is less due to its stress-less and free vibration. The tip displacement of the cantilever also contributes in deterioration in resonance frequency. Moreover, periodically increase in applied stresses result in rapid crack growth.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Influence of crack growths on the performances of cantilever based MEMS devices: Design and simulations
There is a great need to design experimental setup to deal with the fundamental material issues in MEMS. Cantilever being the active part of MEMS is modeled using COMSOL Multiphysics. The model is simulated for small cracks ranging from Nano to Micro-meter. The cracks are produced at the anchor of MEMS device subjected to variations in Eigen frequencies, Stress levels and Tip displacements of cantilever beam and is measured in association with crack growths. These factors are simulated in order to predict the ultimate lifetime in the form of total number of cycles to failure in association with variations in applied stress levels and with the help of Statistical distribution and Paris's law. The Paris's law is utilized by integrating it between the upper and lower limits (crack sizes) that results in predicting the useful lifetime of the cantilever based MEMS device. The simulated results show that at resonance frequency the probability of crack growth is less due to its stress-less and free vibration. The tip displacement of the cantilever also contributes in deterioration in resonance frequency. Moreover, periodically increase in applied stresses result in rapid crack growth.
- 1 January 2014
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Electronics Express
- Vol. 11 (9) , 20140113
A CMOS-MEMS cantilever sensor for capnometric applications
- 1 January 2014
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Electronics Express
- Vol. 11 (9) , 20140113
A CMOS-MEMS cantilever sensor for capnometric applications