Jie-Shing Lo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jie-Shing Lo has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Chang-Tai Jiang
Department of Mechanical Engineering, National United University, Miao-Li, Taiwan, R.O.C.
2 shared publicationsChang Tai Jiang
Department of Mechanical Engineering, National United University, Miaoli City, Taiwan (R.O.C)
1 shared publication- Chien-Chung Kuo
Department of Orthopedics, China Medical University Hospital, Taichung, Taiwan
1 shared publication Chien-Hsun Lu
Department of Mechanical Engineering, National United University, Miao-Li, Taiwan, R.O.C.
1 shared publicationChyn-Shu Deng
Department of Mechanical Engineering, National United University, Miao-Li, Taiwan, R.O.C.
1 shared publicationKun Ling Wu
Department of Mechanical Engineering, Tungnan University, Taipei, Taiwan (R.O.C)
1 shared publication
Latest Publications
- Open Access
- 13 May 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (10) , 4447
Test-Retest Reliability of Sole Morphology Measurements Using a Novel Single-Image-Based Pin-Array Impression Reconstruction Method
Background: Assessment of the sole morphology provides a clinically useful measure of the foot condition, but existing methods are mostly limited to two-dimensional or non-weight-bearing conditions. The current study aimed to assess the reliability of a novel method called Single-Image-Based Pin-Array Impression Reconstruction Method (SIBPAIR) implemented on a commercial foot assessment system, and the intra-rater, inter-rater and inter-session reliability of the SIBPAIR-based protocol for three-dimensional sole morphological measurements. Methods: The reliability of the SIBPAIR method, and the intra-rater, inter-rater, and inter-session reliability of the SIBPAIR-based protocol in measuring morphological parameters of the sole were assessed by repeated measurements of fifteen young healthy adults by two male physical therapists, in terms of intra-class correlation coefficients (ICC) and standard error of measurement (SEM). Results and Conclusions: The SIBPAIR method was found to have very high reliability with very small SEM values, and the SIBPAIR-based protocol also showed very high intra-rater, inter-rater, and inter-session reliability with small SEM. These results indicate that accurate and reliable measurements could be obtained by following the protocol regardless of the rater’s experience or time of measurement. This will be useful for foot assessment and subsequent applications, such as design and manufacture of customized orthoses or shoes.
- 13 May 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (10) , 4447
Open AccessTest-Retest Reliability of Sole Morphology Measurements Using a Novel Single-Image-Based Pin-Array Impression Reconstruction Method
Background: Assessment of the sole morphology provides a clinically useful measure of the foot condition, but existing methods are mostly limited to two-dimensional or non-weight-bearing conditions. The current study aimed to assess the reliability of a novel method called Single-Image-Based Pin-Array Impression Reconstruction Method (SIBPAIR) implemented on a commercial foot assessment system, and the intra-rater, inter-rater and inter-session reliability of the SIBPAIR-based protocol for three-dimensional sole morphological measurements. Methods: The reliability of the SIBPAIR method, and the intra-rater, inter-rater, and inter-session reliability of the SIBPAIR-based protocol in measuring morphological parameters of the sole were assessed by repeated measurements of fifteen young healthy adults by two male physical therapists, in terms of intra-class correlation coefficients (ICC) and standard error of measurement (SEM). Results and Conclusions: The SIBPAIR method was found to have very high reliability with very small SEM values, and the SIBPAIR-based protocol also showed very high intra-rater, inter-rater, and inter-session reliability with small SEM. These results indicate that accurate and reliable measurements could be obtained by following the protocol regardless of the rater’s experience or time of measurement. This will be useful for foot assessment and subsequent applications, such as design and manufacture of customized orthoses or shoes.
- 22 April 2019
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 42 (5) , 401-410
Slotted electrodes for the improvement of machining performances in EDM drilling
In electrical discharge machining (EDM), poor debris removal may occur under certain conditions. This leads to debris accumulation and degrades machining efficiency. In this study, the rotation and retracting movements of slotted electrodes were coordinated during EDM to realize a pumping effect for expelling debris in the gap between the electrodes and workpieces. The study compared the performance of different slotted electrodes with that of a regular cylindrical (RC) electrode. Moreover, a computational fluid dynamics module was adopted to simulate the effects of the RC and slotted electrodes on debris removal capability in EDM under different conditions. The experimental results demonstrated that among all slotted electrodes, the deep slotted electrode engendered the most-favorable debris removal capability. The deep slotted electrode saved machining time by shortening the electrode jump time or even obviating electrode jumping. This increased the material removal rates by 120%–153% during EDM drilling.
- 22 April 2019
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 42 (5) , 401-410
Slotted electrodes for the improvement of machining performances in EDM drilling
In electrical discharge machining (EDM), poor debris removal may occur under certain conditions. This leads to debris accumulation and degrades machining efficiency. In this study, the rotation and retracting movements of slotted electrodes were coordinated during EDM to realize a pumping effect for expelling debris in the gap between the electrodes and workpieces. The study compared the performance of different slotted electrodes with that of a regular cylindrical (RC) electrode. Moreover, a computational fluid dynamics module was adopted to simulate the effects of the RC and slotted electrodes on debris removal capability in EDM under different conditions. The experimental results demonstrated that among all slotted electrodes, the deep slotted electrode engendered the most-favorable debris removal capability. The deep slotted electrode saved machining time by shortening the electrode jump time or even obviating electrode jumping. This increased the material removal rates by 120%–153% during EDM drilling.
- 26 March 2019
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 103 (1-4) , 841-848
Compensation method for profile deviations caused by the complex shape of electrodes in orbital electrical discharge machining
- 26 March 2019
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 103 (1-4) , 841-848
Compensation method for profile deviations caused by the complex shape of electrodes in orbital electrical discharge machining
- 10 January 2018
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture
- Vol. 233 (3) , 756-765
Effect of slotted electrodes on improvement in machining performance of large-scale electrical discharge machining
Under special conditions, electrical discharge machining is prone to experiencing poor machining removal rate. This creates debris deposits that lead to decreased machining efficiency and poorer machining quality in the machining workpieces during machining operations. Thus, the present study investigated the use of slotted electrodes to improve machining debris removal and compared the machining capability of such electrodes with that of cylindrical, nonslotted electrodes. Concurrently, oscilloscopes were used to measure the machining voltage and current signals during the machining process, in which waveforms were analyzed to gain insight into the electrical discharge condition of the electrical discharge machining. Compared with general cylindrical, nonslotted electrodes, the deep slotted electrodes improved the material removal rate on large-scale and hemisphere electrical discharge machining result by 91% and 116.7%, respectively. The experiment results also show that slotted electrodes are inapplicable to finishing operations. Therefore, during roughing operations, slotted electrodes should be used to lower machining time; during finishing operations, cylindrical, nonslotted electrodes should be used to adjust machining precision.
- 10 January 2018
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture
- Vol. 233 (3) , 756-765
Effect of slotted electrodes on improvement in machining performance of large-scale electrical discharge machining
Under special conditions, electrical discharge machining is prone to experiencing poor machining removal rate. This creates debris deposits that lead to decreased machining efficiency and poorer machining quality in the machining workpieces during machining operations. Thus, the present study investigated the use of slotted electrodes to improve machining debris removal and compared the machining capability of such electrodes with that of cylindrical, nonslotted electrodes. Concurrently, oscilloscopes were used to measure the machining voltage and current signals during the machining process, in which waveforms were analyzed to gain insight into the electrical discharge condition of the electrical discharge machining. Compared with general cylindrical, nonslotted electrodes, the deep slotted electrodes improved the material removal rate on large-scale and hemisphere electrical discharge machining result by 91% and 116.7%, respectively. The experiment results also show that slotted electrodes are inapplicable to finishing operations. Therefore, during roughing operations, slotted electrodes should be used to lower machining time; during finishing operations, cylindrical, nonslotted electrodes should be used to adjust machining precision.