JLJie-Shing Lo

Jie-Shing Lo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jie-Shing Lo has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Chang-Tai Jiang

    Department of Mechanical Engineering, National United University, Miao-Li, Taiwan, R.O.C.

    2 shared publications
  • Chang Tai Jiang

    Department of Mechanical Engineering, National United University, Miaoli City, Taiwan (R.O.C)

    1 shared publication
  • Chien-Chung Kuo

    Department of Orthopedics, China Medical University Hospital, Taichung, Taiwan

    1 shared publication
  • Chien-Hsun Lu

    Department of Mechanical Engineering, National United University, Miao-Li, Taiwan, R.O.C.

    1 shared publication
  • Chyn-Shu Deng

    Department of Mechanical Engineering, National United University, Miao-Li, Taiwan, R.O.C.

    1 shared publication
  • Kun Ling Wu

    Department of Mechanical Engineering, Tungnan University, Taipei, Taiwan (R.O.C)

    1 shared publication

Latest Publications

  • Open Access

    Test-Retest Reliability of Sole Morphology Measurements Using a Novel Single-Image-Based Pin-Array Impression Reconstruction Method

    by Tsan-Yang Chen, Chien-Chung Kuo, Li-Wei Hung, Wei-Chun Lee, Jie-Hsing Lo, Hsuan-Lun Lu, Tung-Wu Lu

    Background: Assessment of the sole morphology provides a clinically useful measure of the foot condition, but existing methods are mostly limited to two-dimensional or non-weight-bearing conditions. The current study aimed to assess the reliability of a novel method called Single-Image-Based Pin-Array Impression Reconstruction Method (SIBPAIR) implemented on a commercial foot assessment system, and the intra-rater, inter-rater and inter-session reliability of the SIBPAIR-based protocol for three-dimensional sole morphological measurements. Methods: The reliability of the SIBPAIR method, and the intra-rater, inter-rater, and inter-session reliability of the SIBPAIR-based protocol in measuring morphological parameters of the sole were assessed by repeated measurements of fifteen young healthy adults by two male physical therapists, in terms of intra-class correlation coefficients (ICC) and standard error of measurement (SEM). Results and Conclusions: The SIBPAIR method was found to have very high reliability with very small SEM values, and the SIBPAIR-based protocol also showed very high intra-rater, inter-rater, and inter-session reliability with small SEM. These results indicate that accurate and reliable measurements could be obtained by following the protocol regardless of the rater’s experience or time of measurement. This will be useful for foot assessment and subsequent applications, such as design and manufacture of customized orthoses or shoes.


  • Slotted electrodes for the improvement of machining performances in EDM drilling

    by Jie-Shing Lo, Chyn-Shu Deng, Chang-Tai Jiang, Chien-Hsun Lu

    In electrical discharge machining (EDM), poor debris removal may occur under certain conditions. This leads to debris accumulation and degrades machining efficiency. In this study, the rotation and retracting movements of slotted electrodes were coordinated during EDM to realize a pumping effect for expelling debris in the gap between the electrodes and workpieces. The study compared the performance of different slotted electrodes with that of a regular cylindrical (RC) electrode. Moreover, a computational fluid dynamics module was adopted to simulate the effects of the RC and slotted electrodes on debris removal capability in EDM under different conditions. The experimental results demonstrated that among all slotted electrodes, the deep slotted electrode engendered the most-favorable debris removal capability. The deep slotted electrode saved machining time by shortening the electrode jump time or even obviating electrode jumping. This increased the material removal rates by 120%–153% during EDM drilling.


  • Effect of slotted electrodes on improvement in machining performance of large-scale electrical discharge machining

    by Jie Shing Lo, Chang Tai Jiang, Kun Ling Wu

    Under special conditions, electrical discharge machining is prone to experiencing poor machining removal rate. This creates debris deposits that lead to decreased machining efficiency and poorer machining quality in the machining workpieces during machining operations. Thus, the present study investigated the use of slotted electrodes to improve machining debris removal and compared the machining capability of such electrodes with that of cylindrical, nonslotted electrodes. Concurrently, oscilloscopes were used to measure the machining voltage and current signals during the machining process, in which waveforms were analyzed to gain insight into the electrical discharge condition of the electrical discharge machining. Compared with general cylindrical, nonslotted electrodes, the deep slotted electrodes improved the material removal rate on large-scale and hemisphere electrical discharge machining result by 91% and 116.7%, respectively. The experiment results also show that slotted electrodes are inapplicable to finishing operations. Therefore, during roughing operations, slotted electrodes should be used to lower machining time; during finishing operations, cylindrical, nonslotted electrodes should be used to adjust machining precision.