MMManuel Monge

Manuel Monge

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Manuel Monge has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Iris 128x: open-source 128 channel headstages for neural stimulation and recording

    by Emma K Jacobs, Manuel Monge, Ander Switalla, Rebecca A Frederick, Felix Deku

    Objective. Investigation into complex neural circuits necessitates interfaces capable of high channel count recording and stimulation. However, existing commercial neural headstages often have limited scalability, restrictive proprietary designs, and constrained bidirectional capabilities, which worsens accessibility challenges and compels researchers to reinvent tools rather than build on a shared foundation. Approach. Here, we present two open-source, 128 channel headstages—Iris 128B and Iris 128S—designed for integration with microelectrode arrays. The Iris 128B enables fully bidirectional interfacing, with stimulation or recording across all 128 electrode channels, while the Iris 128S provides recording on 128 channels and stimulation on 16 simultaneous channels, which can be assigned to any 16 of the 32 available stimulation channels. Both designs use Intan Technologies’ RHS and RHD series integrated circuits for amplification, filtering, digitization and stimulation, and are available on GitHub. Main results. The headstages were validated through benchtop impedance, noise, and frequency response measurements, as well as acute in vivo recordings in an anesthetized rat. Results demonstrate low noise levels and reliable signal acquisition across all channels. Significance. By releasing fully documented printed circuit board designs for headstages, this work aims to take a step towards broader adoption of bidirectional recording and stimulation systems while increasing channel counts. Future iterations will focus on miniaturization and wireless integration to improve usability in chronic and freely moving small animal experiments.


  • Rectifier Design for Highly Loaded Inductive Wireless Power Transfer Systems for Biomedical Applications

    by Manjunath Machnoor, Pragya Kosta, Manuel Monge, Gianluca Lazzi

    Power transfer efficiency (PTE) and harmonics are crucial performance parameters of the resonant rectifier design for low/medium coupling inductive wireless power transfer (WPT) systems used in wireless biomedical implants. The performance of a resonant rectifier degrades under higher loading and lower coupling conditions as the voltage available to the rectifier at the output of the receiver coil becomes low. As the diode turn-on impedance increases, diodes turn on incompletely, leading to non-linearities that reduce rectifier efficiency and output voltage. This work proposes a new rectifier design to increase efficiency and reduce harmonics by decreasing the diode turn-on impedance compared to traditional rectifier designs, such as resonant Half Wave Rectifier (HWR). The proposed rectifier design offers individual paths for RF and rectification signals, which reduces the non-linear loading on the receiver coil and improves diode turn-on performance. Measurement and SPICE simulation results show efficiency enhancement of 50% and reduction of harmonics by 6 dB for the proposed rectifier compared to HWR.


  • A Bimodal Low-Power Transceiver Featuring a Ring Oscillator-Based Transmitter and Magnetic Field-Based Receiver for Insertable Smart Pills

    by Angsagan Abdigazy, Manuel Monge

    This paper presents a novel bimodal, low-power, mm-scale transceiver for insertable smart pills. The proposed PA-less, 915 MHz uplink transmitter (TX) incorporates an 1.2×1.2 mm2 on-chip, non-resonated antenna as part of a current-starved ring oscillator (RO) and directly transmits data by turning the RO on/off. This RO-based uplink TX is implemented in 180 nm CMOS along with a power management unit, which generates all internal reference voltages and supplies from a single battery. The uplink TX achieves a data rate of 33 Mb/s and consumes 210 B5W, resulting in an energy efficiency of 6.4 pJ/bit. The orientation-insensitive magnetic field-based downlink receiver (RX) is implemented with an external 3-D magnetic sensor, achieves 0.02 kb/s of data rate limited by our measurement setup, and consumes 270 B5W. Wireless measurements in saline over 150 cm and prototype of the 3.2×13.6×2.3 mm3 insertable pill are presented.


  • Dual-band Transceiver with Mutually-coupled On-chip Antennas for Implantable/Wearable Devices

    by Nilan Udayanga, Manuel Monge

    This paper presents a fully integrated dual-band transceiver (TRX) with mutually-coupled on-chip antennas for implantable and wearable devices. It operates at 915 MHz and 2.4 GHz in both transmit and receive modes to enable bidirectional communication between medical and consumer electronics using a single chip. The TRX is fabricated in 180 nm CMOS along with a power management unit (PMU) with a size of 2.4×1.9 mm 2 , The PMU generates the required supplies to power the internal TRX, external sensors, and controller units from a single battery. The transmitter (TX) consists of a mutually-coupled dual-band oscillator and uses the on-chip antennas as the inductors of the oscillators. The maximum uplink data rates of the TXs are 20 Mb/s and 40 Mb/s for 915 MHz and 2.4 GHz, respectively, with corresponding TX efficiencies of 62 pJ/b and 35 pJ/b. The maximum achievable downlink data rates are 2 Mb/s and 1 Mb/s for 915 MHz and 2.4 GHz, respectively, resulting in 2 pJ/b and 4 pJ/b of energy efficiencies. Importantly, the proposed TRX achieves uplink and downlink communication ranges of 30 cm and 17 cm for the 915 MHz band, and of 38 cm and 2 cm for the 2.4 GHz band, respectively.


  • Localization of microscale devices in vivo using addressable transmitters operated as magnetic spins

    by Manuel Monge, Audrey Lee-Gosselin, Mikhail G. Shapiro, Azita Emami

    The function of miniature wireless medical devices, such as capsule endoscopes, biosensors and drug-delivery systems, depends critically on their location inside the body. However, existing electromagnetic, acoustic and imaging-based methods for localizing and communicating with such devices suffer from limitations arising from physical tissue properties or from the performance of the imaging modality. Here, we embody the principles of nuclear magnetic resonance in a silicon integrated-circuit approach for microscale device localization. Analogous to the behaviour of nuclear spins, the engineered miniaturized radio frequency transmitters encode their location in space by shifting their output frequency in proportion to the local magnetic field; applied field gradients thus allow each device to be located precisely from its signal’s frequency. The devices are integrated in circuits smaller than 0.7 mm3 and manufactured through a standard complementary-metal-oxide-semiconductor process, and are capable of sub-millimetre localization in vitro and in vivo. The technology is inherently robust to tissue properties, scalable to multiple devices, and suitable for the development of microscale devices to monitor and treat disease.


  • A fully intraocular 0.0169mm2/pixel 512-channel self-calibrating epiretinal prosthesis in 65nm CMOS

    by Manuel Monge, Mayank Raj, Meisam Honarvar-Nazari, Han-Chieh Chang, Yu Zhao, James Weiland, Mark Humayun, Yu-Chong Tai, Azita Emami-Neyestanak

    Since their conception and success in human trials, the flexibility and spatial resolution of retinal prostheses have been of major interest. Clinical studies have revealed that hundreds of channels are needed to restore functional visual perception, and more sophisticated waveforms present advantages over biphasic pulses. Initial designs targeted stimulation current levels up to 1mA to ensure functionality. For such designs, an output compliance of >10V was required, and HV technologies were used at the expense of area and power consumption. Human clinical trials have recently shown that implanted electrodes present a stimulus threshold as low as 50μA. In addition, advances in implant technology promise close placement of electrode array and retinal tissue, which can further decrease the required current. Thus, highly scaled LV technologies can provide alternative means to reduce area and power, and to support hundreds of flexible independent channels for fully intraocular implants. In this paper, a self-calibrating 512-channel epiretinal prosthesis in 65nm CMOS is presented. It features dual-band telemetry for power and data, clock recovery, a 2-step calibration technique to match biphasic stimulation currents, and an independent arbitrary output waveform per channel. The implant integrates coils (power and data), IC, external capacitors and electrode array using a biocompatible parylene substrate, providing a fully intraocular solution.