Nádia da Rocha Svizero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nádia da Rocha Svizero has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Paulo Henrique Perlatti D'ALpino
Biotechnology and Innovation in Health Program, Universidade Anhanguera de São Paulo (UNIAN-SP), São Paulo, SP, Brazil
11 shared publications - Frederick Allen Rueggeberg
Augusta University, USA
8 shared publications David H. Pashley
5 shared publications- David Pashley
Department of Oral Biology & Maxillofacial Pathology, School of Dentistry, Medical College of Georgia, Augusta, GA 30912-1129, USA
4 shared publications José C Pereira
4 shared publications- Carlos Frederico Oliveira Graeff
São Paulo State University (UNESP)
3 shared publications
Latest Publications
- 16 May 2023
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 37 (24) , 3569-3581
10-MDP-based dentin bonding systems: why is chlorhexidine not worth to be used adjunctively?
- 16 May 2023
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 37 (24) , 3569-3581
10-MDP-based dentin bonding systems: why is chlorhexidine not worth to be used adjunctively?
- Open Access
- 31 March 2022
- Published by Wiley in The Scientific World Journal
- Vol. 2022, 1-9
Effectiveness of Experimental Whitening Toothpastes Containing Colorants on the Optical Properties of Enamel
Objective. This in vitro study investigated the whitening potential of experimental toothpastes containing optical colorants in their formulations in comparison with commercial products. The chemical and physical characteristics of the toothpastes, the morphology, and elemental analysis of the enamel surface after treatment were also analyzed. Materials and Methods. One hundred twenty-five bovine incisor teeth were randomly divided into five groups according to the treatment: (i) experimental PHTALOX dental gel (PHT); (ii) experimental blue silica dental gel (SDG); (iii) Sensodyne Whitening Repair & Protect (WRP); (iv) Sensodyne True White (STW); (v) Snow White Toothpaste (SWS). The whiteness index differences (ΔWID) and color alteration (CIELab-ΔE, CIEDE2000-ΔE00) were calculated after color change analysis using a spectrophotometer before and after the enamel treatment (n=25). The surface and cross-sectional micromorphology were assessed using scanning electron microscopy. The elemental analyses were determined with energy-dispersive X-ray spectroscopy (EDS). The pH, particle size, zeta potential, and polydispersity index of toothpaste were evaluated. Data was statistically analyzed (ANOVA/Tukey, 5). Results. Whitening toothpastes containing optical colorants were effective for whitening the enamel, as whiter teeth were observed following treatment (higher means of ΔWID). In addition, when the parameters ΔEab and ΔE00 were evaluated, these toothpastes were graded as very good effectiveness (grade 4). Other toothpastes were graded as 3 (good effectiveness). PHT had a neutral pH and a larger mean particle size (412.8nm). Elemental analysis demonstrated enamel with a silicon-enriched mineral layer on the enamel surface treated with SDG. The Ca/P ratio after enamel treatment varied from 1.74 (SWS) to 2.04 (SDG and WRP). Conclusions. Experimental whitening toothpastes containing optical colorants are effective at bleaching the enamel. The synergism among the different parameters analyzed seems to positively affect the color change after brushing with whitening toothpastes containing optical colorants.
- 31 March 2022
- Published by Wiley in The Scientific World Journal
- Vol. 2022, 1-9
Open AccessEffectiveness of Experimental Whitening Toothpastes Containing Colorants on the Optical Properties of Enamel
Objective. This in vitro study investigated the whitening potential of experimental toothpastes containing optical colorants in their formulations in comparison with commercial products. The chemical and physical characteristics of the toothpastes, the morphology, and elemental analysis of the enamel surface after treatment were also analyzed. Materials and Methods. One hundred twenty-five bovine incisor teeth were randomly divided into five groups according to the treatment: (i) experimental PHTALOX dental gel (PHT); (ii) experimental blue silica dental gel (SDG); (iii) Sensodyne Whitening Repair & Protect (WRP); (iv) Sensodyne True White (STW); (v) Snow White Toothpaste (SWS). The whiteness index differences (ΔWID) and color alteration (CIELab-ΔE, CIEDE2000-ΔE00) were calculated after color change analysis using a spectrophotometer before and after the enamel treatment (n=25). The surface and cross-sectional micromorphology were assessed using scanning electron microscopy. The elemental analyses were determined with energy-dispersive X-ray spectroscopy (EDS). The pH, particle size, zeta potential, and polydispersity index of toothpaste were evaluated. Data was statistically analyzed (ANOVA/Tukey, 5). Results. Whitening toothpastes containing optical colorants were effective for whitening the enamel, as whiter teeth were observed following treatment (higher means of ΔWID). In addition, when the parameters ΔEab and ΔE00 were evaluated, these toothpastes were graded as very good effectiveness (grade 4). Other toothpastes were graded as 3 (good effectiveness). PHT had a neutral pH and a larger mean particle size (412.8nm). Elemental analysis demonstrated enamel with a silicon-enriched mineral layer on the enamel surface treated with SDG. The Ca/P ratio after enamel treatment varied from 1.74 (SWS) to 2.04 (SDG and WRP). Conclusions. Experimental whitening toothpastes containing optical colorants are effective at bleaching the enamel. The synergism among the different parameters analyzed seems to positively affect the color change after brushing with whitening toothpastes containing optical colorants.
- 21 September 2015
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 20 (5) , 1011-1019
Effects of age condition on the distribution and integrity of inorganic fillers in dental resin composites
Objectives The aim of this study is to evaluate the distribution of the filler size along with the zeta potential, and the integrity of silane-bonded filler surface in different types of restorative dental composites as a function of the material age condition. Materials and methods Filtek P60 (hybrid composite), Filtek Z250 (small-particle filled composite), Filtek Z350XT (nanofilled composite), and Filtek Silorane (silorane composite) (3M ESPE) were tested at different stage condition (i.e., fresh/new, aged, and expired). Composites were submitted to an accelerated aging protocol (Arrhenius model). Specimens were obtained by first diluting each composite specimen in ethanol and then dispersed in potassium chloride solution (0.001 mol%). Composite fillers were characterized for their zeta potential, mean particle size, size distribution, via poly-dispersion dynamic light scattering. The integrity of the silane-bonded surface of the fillers was characterized by FTIR. Results The material age influenced significantly the outcomes; Zeta potential, filler characteristics, and silane integrity varied both after aging and expiration. Silorane presented the broadest filler distribution and lowest zeta potential. Nanofilled and silorane composites exhibited decreased peak intensities in the FTIR analysis, indicating a deficiency of the silane integrity after aging or expiry time. Conclusion Regardless to the material condition, the hybrid and the small-particle-filled composites were more stable overtime as no significant alteration in filler size distribution, diameter, and zeta potential occurred. A deficiency in the silane integrity in the nanofilled and silorane composites seems to be affected by the material stage condition. Clinical significance The materials conditions tested in this study influenced the filler size distribution, the zeta potential, and integrity of the silane adsorbed on fillers in the nanofilled and silorane composites. Thus, this may result in a decrease of the clinical performance of aforementioned composites, in particular, if these are used after inappropriate storage conditions.
- 21 September 2015
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 20 (5) , 1011-1019
Effects of age condition on the distribution and integrity of inorganic fillers in dental resin composites
Objectives The aim of this study is to evaluate the distribution of the filler size along with the zeta potential, and the integrity of silane-bonded filler surface in different types of restorative dental composites as a function of the material age condition. Materials and methods Filtek P60 (hybrid composite), Filtek Z250 (small-particle filled composite), Filtek Z350XT (nanofilled composite), and Filtek Silorane (silorane composite) (3M ESPE) were tested at different stage condition (i.e., fresh/new, aged, and expired). Composites were submitted to an accelerated aging protocol (Arrhenius model). Specimens were obtained by first diluting each composite specimen in ethanol and then dispersed in potassium chloride solution (0.001 mol%). Composite fillers were characterized for their zeta potential, mean particle size, size distribution, via poly-dispersion dynamic light scattering. The integrity of the silane-bonded surface of the fillers was characterized by FTIR. Results The material age influenced significantly the outcomes; Zeta potential, filler characteristics, and silane integrity varied both after aging and expiration. Silorane presented the broadest filler distribution and lowest zeta potential. Nanofilled and silorane composites exhibited decreased peak intensities in the FTIR analysis, indicating a deficiency of the silane integrity after aging or expiry time. Conclusion Regardless to the material condition, the hybrid and the small-particle-filled composites were more stable overtime as no significant alteration in filler size distribution, diameter, and zeta potential occurred. A deficiency in the silane integrity in the nanofilled and silorane composites seems to be affected by the material stage condition. Clinical significance The materials conditions tested in this study influenced the filler size distribution, the zeta potential, and integrity of the silane adsorbed on fillers in the nanofilled and silorane composites. Thus, this may result in a decrease of the clinical performance of aforementioned composites, in particular, if these are used after inappropriate storage conditions.
- 1 September 2015
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 49, 300-309
Polymerization kinetics and polymerization stress in resin composites after accelerated aging as a function of the expiration date
- 1 September 2015
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 49, 300-309
Polymerization kinetics and polymerization stress in resin composites after accelerated aging as a function of the expiration date
- Open Access
- 4 July 2014
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 22 (5) , 373-381
Micro-sized erosions in a nanofilled composite after repeated acidic beverage exposures: consequences of clusters dislodgments
Key words: Composite resins; Color; Hardness; Time factor
- 4 July 2014
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 22 (5) , 373-381
Open AccessMicro-sized erosions in a nanofilled composite after repeated acidic beverage exposures: consequences of clusters dislodgments
Key words: Composite resins; Color; Hardness; Time factor
- 1 January 2013
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 32 (1) , 32-41
Effects of curing protocols on fluid kinetics and hardness of resin cements
The effects of polymerization protocols on water sorption/solubility, the diffusion coefficient (D), the flux (J), and the hardness (KH) of two resin cements were evaluated. The materials were manipulated and divided into three groups (n=6) according to the curing protocol: PA=photoactivation (40 s); DP=delayed photoactivation (10 min self-curing plus 40 s photoactivated); CA=chemical activation. After desiccation, the specimens were weighed, stored in water (37ºC), evaluated over 28-days, and hardness recorded. Chemical activation resulted in lower net water uptake, D, and J for RelyX ARC (RX). For Variolink II (VL), CA yielded equivalent D and lower J; however, photoactivation resulted in lower net water uptake. Hardness of VL was less affected by the water storage, irrespective of the polymerization protocol. Considering the water diffusion parameters, VL demonstrated immediate photoactivation dependence; for RX, a chemical activation. Different polymerization protocols affect the fluid kinetics and the hardness of the resin cements tested.
- 1 January 2013
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 32 (1) , 32-41
Effects of curing protocols on fluid kinetics and hardness of resin cements
The effects of polymerization protocols on water sorption/solubility, the diffusion coefficient (D), the flux (J), and the hardness (KH) of two resin cements were evaluated. The materials were manipulated and divided into three groups (n=6) according to the curing protocol: PA=photoactivation (40 s); DP=delayed photoactivation (10 min self-curing plus 40 s photoactivated); CA=chemical activation. After desiccation, the specimens were weighed, stored in water (37ºC), evaluated over 28-days, and hardness recorded. Chemical activation resulted in lower net water uptake, D, and J for RelyX ARC (RX). For Variolink II (VL), CA yielded equivalent D and lower J; however, photoactivation resulted in lower net water uptake. Hardness of VL was less affected by the water storage, irrespective of the polymerization protocol. Considering the water diffusion parameters, VL demonstrated immediate photoactivation dependence; for RX, a chemical activation. Different polymerization protocols affect the fluid kinetics and the hardness of the resin cements tested.
- 1 February 2007
- Vol. 20 (1) , 46-52
Influence of light-curing sources on polymerization reaction kinetics of a restorative system.
To determine the effect of using a variety of commercial light-curing units on polymerization of a dentin-bonding agent (Adper Single Bond) and of a resin composite (Filtek Z250). Infrared (IR) spectra were obtained kinetically at one scan/second at 2 cm(-1) resolution for a period of 5 minutes and were analyzed for: maximum conversion rate (%/s), time into exposure when maximum rate occurred (seconds), conversion at maximum rate (%), and total conversion (%) at 300 seconds by comparison of aliphatic-to-aromatic absorption IR peak ratios, before and after polymerization. Light units used were: QTH 540 mW/cm2 (XL3000); LED 750 mW/cm2 (Elipar FreeLight 2); PAC 2,130 mW/cm2 (ARC II). Exposure followed manufacturers' recommendations: dentin bonding agent for 10 seconds, RC for 20 seconds (QTH), and 10 seconds (LED and PAC). Polymerization kinetics was evaluated at the bottom surface (2.5 mm thick) for the resin composite and as a thin film for the dentin bonding agent on the diamond surface of an attenuated total reflectance accessory in the IR spectrometer. Values (n = 5) were compared using ANOVA and Tukey's pairwise post-hoc test: pre-set alpha 0.05. PAC produced the highest total conversion and conversion rate for the resin composite (P < 0.05). Total conversion was lower for dentin bonding adhesive using PAC than with LED or QTH (P < 0.05). LED provided the highest proportion of conversion at the maximum rate with respect to conversion at 300 seconds for both materials. QTH demonstrated the lowest maximum rate value that occurred at a longer time into exposure (P < 0.05). Polymerization kinetic parameters varied greatly between the restorative materials as well as among light-curing unit types when compared to values observed when using a QTH light as control.
- 1 February 2007
- Vol. 20 (1) , 46-52
Influence of light-curing sources on polymerization reaction kinetics of a restorative system.
To determine the effect of using a variety of commercial light-curing units on polymerization of a dentin-bonding agent (Adper Single Bond) and of a resin composite (Filtek Z250). Infrared (IR) spectra were obtained kinetically at one scan/second at 2 cm(-1) resolution for a period of 5 minutes and were analyzed for: maximum conversion rate (%/s), time into exposure when maximum rate occurred (seconds), conversion at maximum rate (%), and total conversion (%) at 300 seconds by comparison of aliphatic-to-aromatic absorption IR peak ratios, before and after polymerization. Light units used were: QTH 540 mW/cm2 (XL3000); LED 750 mW/cm2 (Elipar FreeLight 2); PAC 2,130 mW/cm2 (ARC II). Exposure followed manufacturers' recommendations: dentin bonding agent for 10 seconds, RC for 20 seconds (QTH), and 10 seconds (LED and PAC). Polymerization kinetics was evaluated at the bottom surface (2.5 mm thick) for the resin composite and as a thin film for the dentin bonding agent on the diamond surface of an attenuated total reflectance accessory in the IR spectrometer. Values (n = 5) were compared using ANOVA and Tukey's pairwise post-hoc test: pre-set alpha 0.05. PAC produced the highest total conversion and conversion rate for the resin composite (P < 0.05). Total conversion was lower for dentin bonding adhesive using PAC than with LED or QTH (P < 0.05). LED provided the highest proportion of conversion at the maximum rate with respect to conversion at 300 seconds for both materials. QTH demonstrated the lowest maximum rate value that occurred at a longer time into exposure (P < 0.05). Polymerization kinetic parameters varied greatly between the restorative materials as well as among light-curing unit types when compared to values observed when using a QTH light as control.
- 1 October 2006
- Vol. 8 (5) , 279-84
A new technique for assessing hybrid layer interfacial micromorphology and integrity: two-photon laser microscopy.
This study describes a two-photon laser fluorescence microscopy technique developed to evaluate the interfacial micromorphology of the hybrid layer in bonded restorations. Micropermeability of the hybrid layer was characterized by means of simultaneously contrasting a dye-containing adhesive with a differently colored dye placed into the pulp chamber and allowed to diffuse toward the different-colored hybrid layer. A fluorescent red dye (rhodamine B) was incorporated into a commercial dentin bonding agent. Class I preparations (margins in enamel) were made on extracted human third molars. The teeth were restored using conventional methods: bonding agent, composite, finishing, and polishing. An aqueous solution of a yellow/green dye (fluorescein) was then placed into the pulp chamber for 3 h, allowing time to diffuse toward the different-colored bonded interface. The teeth were then embedded, sectioned, and microscopically analyzed using two-photon laser microscopy at 40X magnification. Subsurface fluorescent imaging using this technique enabled interfacial micromorphology to be characterized at submicrometer resolution and provided high-contrast images. The quality of surrounding structures and potential presence of gaps were also precisely assessed. Two-photon laser microscopy provided high quality, high-resolution images of the bonded interface and surrounding areas, allowing accurate qualitative and quantitative analysis of the structure and integrity of the hybrid layer.
- 1 October 2006
- Vol. 8 (5) , 279-84
A new technique for assessing hybrid layer interfacial micromorphology and integrity: two-photon laser microscopy.
This study describes a two-photon laser fluorescence microscopy technique developed to evaluate the interfacial micromorphology of the hybrid layer in bonded restorations. Micropermeability of the hybrid layer was characterized by means of simultaneously contrasting a dye-containing adhesive with a differently colored dye placed into the pulp chamber and allowed to diffuse toward the different-colored hybrid layer. A fluorescent red dye (rhodamine B) was incorporated into a commercial dentin bonding agent. Class I preparations (margins in enamel) were made on extracted human third molars. The teeth were restored using conventional methods: bonding agent, composite, finishing, and polishing. An aqueous solution of a yellow/green dye (fluorescein) was then placed into the pulp chamber for 3 h, allowing time to diffuse toward the different-colored bonded interface. The teeth were then embedded, sectioned, and microscopically analyzed using two-photon laser microscopy at 40X magnification. Subsurface fluorescent imaging using this technique enabled interfacial micromorphology to be characterized at submicrometer resolution and provided high-contrast images. The quality of surrounding structures and potential presence of gaps were also precisely assessed. Two-photon laser microscopy provided high quality, high-resolution images of the bonded interface and surrounding areas, allowing accurate qualitative and quantitative analysis of the structure and integrity of the hybrid layer.
- 1 October 2006
- Vol. 8 (5) , 285-92
Factors affecting use of fluorescent agents in identification of resin-based polymers.
The present study is a compilation of methodologies developed in order to evaluate the effects of addition of a fluorescent agent, rhodamine B, to resin-based materials. The intent of the work was to develop a systematic methodology that accounts for variables not shown to be of concern in past testing, but may significantly affect interpretation of the resulting images and material properties. Different methodologies were specifically developed to evaluate factors affecting the use of the fluorescent agent rhodamine B in the identification of resin-based materials. The influence of dye concentration was evaluated with respect to adhesive polymerization reaction kinetics and bond strength of the resin into which the dye is added. The pH of the dye-solvent solution was also considered. Additionally, the mass and percentage of rhodamine B leached into different media over time was determined. It was demonstrated that a specific dye must be used with caution, and the concentration of a fluorescent agent is important with respect to both the conversion and bond strength of the resin to which the dye is added. An alcohol-based dye solution also produced an extremely high amount of dye leaching from polymerized specimens. The adhesive pH was not altered. The standardized methodology developed here to analyze restoration interfaces using a fluorescent dye can lessen the impact of variables when interpreting results.
- 1 October 2006
- Vol. 8 (5) , 285-92
Factors affecting use of fluorescent agents in identification of resin-based polymers.
The present study is a compilation of methodologies developed in order to evaluate the effects of addition of a fluorescent agent, rhodamine B, to resin-based materials. The intent of the work was to develop a systematic methodology that accounts for variables not shown to be of concern in past testing, but may significantly affect interpretation of the resulting images and material properties. Different methodologies were specifically developed to evaluate factors affecting the use of the fluorescent agent rhodamine B in the identification of resin-based materials. The influence of dye concentration was evaluated with respect to adhesive polymerization reaction kinetics and bond strength of the resin into which the dye is added. The pH of the dye-solvent solution was also considered. Additionally, the mass and percentage of rhodamine B leached into different media over time was determined. It was demonstrated that a specific dye must be used with caution, and the concentration of a fluorescent agent is important with respect to both the conversion and bond strength of the resin to which the dye is added. An alcohol-based dye solution also produced an extremely high amount of dye leaching from polymerized specimens. The adhesive pH was not altered. The standardized methodology developed here to analyze restoration interfaces using a fluorescent dye can lessen the impact of variables when interpreting results.
- 1 October 2006
- Vol. 8 (5) , 293-8
Bond strength of resin-based restorations polymerized with different light-curing sources.
To evaluate the influence of different light-curing units on microtensile bond strength of resin composite restorations. Standardized Class I preparations (6.0 x 4.5 mm, 2.5 mm deep) were made in extracted human third molars after abrading the cusps. Resin was inserted in bulk using a 3M ESPE restorative system [Adper Single Bond (DBA)/ Filtek Z250 (RC)]. Both materials were polymerized using different light-curing units: QTH at 540 mW/cm(2) (XL 3000, 3M ESPE); LED at 750 mW/cm(2) (Elipar FreeLight2, 3M ESPE); PAC at 2130 mW/cm(2) (Arc Light II, Air Techniques). Nine different light combinations were developed to polymerize both DBA and RC: QTH/QTH; QTH/LED; QTH/PAC; LED/LED; LED/QTH; LED/PAC; PAC/PAC; PAC/QTH; PAC/LED. Restored teeth were stored in distilled water for 24 h at 37 degrees C and then sectioned, yielding stick-shaped specimens with a bonded area of approximately 0.9 mm(2). Specimens were assessed in a testing machine at a crosshead speed of 1 mm/min. The results were analyzed using two-way ANOVA and Tukey's test at a pre-set alpha = 0.05. The combinations PAC/QTH and QTH/QTH presented the highest bond strength values, and LED/QTH the lowest (p < 0.05). Significantly lower values were observed in combinations when the LED light was used to polymerize DBA compared to QTH and PAC lights, irrespective of the light source used to polymerize RC (p < 0.05). Same light combinations presented similar bond strength values. Different light sources influence restoration bond strength. Bond strength is more dependent on the light source used for DBA than for curing RC.
- 1 October 2006
- Vol. 8 (5) , 293-8
Bond strength of resin-based restorations polymerized with different light-curing sources.
To evaluate the influence of different light-curing units on microtensile bond strength of resin composite restorations. Standardized Class I preparations (6.0 x 4.5 mm, 2.5 mm deep) were made in extracted human third molars after abrading the cusps. Resin was inserted in bulk using a 3M ESPE restorative system [Adper Single Bond (DBA)/ Filtek Z250 (RC)]. Both materials were polymerized using different light-curing units: QTH at 540 mW/cm(2) (XL 3000, 3M ESPE); LED at 750 mW/cm(2) (Elipar FreeLight2, 3M ESPE); PAC at 2130 mW/cm(2) (Arc Light II, Air Techniques). Nine different light combinations were developed to polymerize both DBA and RC: QTH/QTH; QTH/LED; QTH/PAC; LED/LED; LED/QTH; LED/PAC; PAC/PAC; PAC/QTH; PAC/LED. Restored teeth were stored in distilled water for 24 h at 37 degrees C and then sectioned, yielding stick-shaped specimens with a bonded area of approximately 0.9 mm(2). Specimens were assessed in a testing machine at a crosshead speed of 1 mm/min. The results were analyzed using two-way ANOVA and Tukey's test at a pre-set alpha = 0.05. The combinations PAC/QTH and QTH/QTH presented the highest bond strength values, and LED/QTH the lowest (p < 0.05). Significantly lower values were observed in combinations when the LED light was used to polymerize DBA compared to QTH and PAC lights, irrespective of the light source used to polymerize RC (p < 0.05). Same light combinations presented similar bond strength values. Different light sources influence restoration bond strength. Bond strength is more dependent on the light source used for DBA than for curing RC.