MYMetin Yildiz

Metin Yildiz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Metin Yildiz has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • NEW TURKISH VIRTUAL KEYBOARD APPLICATION USING SIMPLE CAMERA-MOUNTED EYEGLASSES

    by Seval Uğurlu, Muhammet Yorulmaz, Metin Yıldız

    In recent years, many studies have been conducted to enable people with ALS and similar neuromuscular diseases to communicate by writing with their eyes. The methods used in the literature have various disadvantages: electrooculography-based methods involve electrical connections that come into contact with the person, infrared camera-based methods are commercial systems with high costs, and webcam-based methods have low performance. In this study, a Turkish virtual keyboard application that allows eye-typing based on an eye-tracking system created with a mini camera mounted on the frame of glasses was introduced, and its performance was tested. Experiments were conducted with 20 healthy volunteers in two sessions on different days, and typing speed, accuracy, and user satisfaction of the system were measured. In the first session, users were able to write the given pangram with an average speed of 6.19 words/minute and an accuracy of 94.1%, while in the second session, they were able to write it with an average speed of 6.74 words/minute and an accuracy of 95.5%. With the word completion feature added to the system, typing speed has increased even more. It has been evaluated that the developed system can be an alternative to commercial systems in terms of price performance.


  • Open Access

    A Preliminary Study on OSA Severity Levels Detection by Evaluating Speech Signals Nonlinearities With Multi-Class Classification

    by Tuğçe Kantar Uğur, Derya Yilmaz, Metın Yildiz, Sınan Yetkın

    Diagnosis of obstructive sleep apnea (OSA) from speech has become a popular research area in recent years, which can be an alternative way, to the application difficulties in polysomnography (PSG). The promising results obtained in our previous study, in which we tried to detect apnea using nonlinear analysis of speech, gave rise to the thought that it is possible to detect OSA and OSA severity by diversifying speech samples and nonlinear features. The principal aim of this study, for the first time in the literature, is to detect the OSA severity levels as mild, moderate, and severe as in the clinic use (multi-class classification) using nonlinear analyses of speech while the patient is awake. In addition, healthy/OSA classification (binary classification) was also carried out. The feature selection method of ANOVA was applied to 336 features (28 voices × 12 features) for each subject, 14 and 5 features were used in multi-class and binary classifications, respectively. As a result of the classifications made with various KNN and SVMs models, the best results were obtained by SVMs in both classifications for OSA severities (with one-vs-all classification scheme and the Gaussian kernel) and OSA detection (with the quadratic kernel) as 82% and 95.1% accuracies, respectively. The proposed study showed that OSA and OSA severity can be determined with the small number of nonlinear features calculated from a few different speech samples, in nearly 15 minutes, consistent with PSG results (simple snorer, mild, moderate and severe OSA). In conclusion, the highest OSA/healthy classification accuracy rate in the literature was achieved. Furthermore, OSA severity detection in four-class performed quite well as a preliminary study.


  • The Source of Heart Rhythm Changes Caused by Swallowing

    by Metin Yildiz, Serian Doma

    Swallowing can lead to the development of syncope in people who have difficulty swallowing during food intake. It has shown that even spontaneous saliva swallowing can change heart rate variability (HRV). Recently, it has been suggested that changes in heart rate during swallowing may be caused by respiratory activities. In this study, the hypothesis that swallowing induced HRV are caused from breathing changes during swallowing has been tested. For this purpose, electrocardiogram (ECG), chest circumference (respiration) signals and swallowing sounds were recorded simultaneously from 20 subjects. Subjects were asked not to swallow their saliva in the first 4 min of the experiment and to swallow them several times in the next 4 min. To observe respiratory effects on HRV during swallowing, a detailed cardio-respiratory system mathematical model was used. By applying recorded chest circumference signal to the mathematical model, respiration induced HRV changes were obtained. The HRV parameters of with and without swallowing regions of the real (obtained from ECG) and model-HRV (obtained from mathematical model) were compared by paired Student t test. Statistical differences seen in the real-HRV between the swallowing and non-swallowing regions (SDNN, LF power, approximate entropy) were not observed in the model-HRV. Considering that the only factor constituting HRV in the mathematical model is respiration, it was concluded that swallowing changes HRV with a mechanism other than breathing changes.


  • Gaze-Controlled Turkish Virtual Keyboard Application with Webcam

    by Metin Yildiz, Muhammet Yorulmaz

    In this study, an easy-to-use and inexpensive system aimed at solving the communication needs of people with disabilities such as ALS by writing with their eyes was introduced. The performance of the system are measured by writing speed (word per minutes) and error rate. The system consists of a webcam that fixed in front of the eye with a plastic eyeglass, and a computer. On the keyboard proposed in this study, the characters to be typed are placed at 22 discrete points which can be detected without error. 16 characters which are most used in Turkish (total %85 usage rate), can be selected with a single gaze. Other characters can be selected with gazing these points with a dwell time. The iris circle on the image recorded by the camera is found according to the Hough transform and the position of the center coordinates of the eye is classified by using the k-nearest neighbor algorithm from the machine learning methods and the character to be written is determined. In order to select the letters at the gaze points, the letter that is highlighted by the software in voice and color is moved to the writing area in the middle of the screen by eye. As a result of the first experiments, it has been observed that the system developed allows the average of 6.63 words per minute (approximately 33 letters) to be written with an error rate of 0.86%.


  • Open Access

    Termoelektrik Modül Kullanılarak Gerçekleştirilen Bilgisayar Tabanlı Fizik Tedavi Cihazı

    by Meti̇n Yildiz, Anıl Erdem GUNT, Pelinsu Er, Veli Gürler, M. İrEm Naneci̇

    Sıcak ve soğuk uygulamalar, fizik tedavide çok kullanılan tedavi yöntemlerindendir. Geleneksel yöntemlerde, tedavi edici etkiyi sağlamak için doku sıcaklığı; sıcak ve soğuk torbalar veya su havuzları ile belirli sıcaklık aralıklarında tutulmaya çalışılmaktadır. Bu çalışmada, dokunun sıcaklığını, bilgisayardan girilen süre boyunca tedavinin uygulandığı sıcaklıkta tutmaya yarayan, bilgisayar kontrollü bir fizik tedavi cihazı tanıtılmıştır. Doku sıcaklığının değiştirilmesi için termoelektrik modüllerin kullanıldığı cihazda, sıcaklığın sabit tutulması için açkapa kontrol yöntemi uygulanmıştır. Cihazın klinik uygulamalarda kullanılıp kullanılamayacağını test etmek için; geleneksel uygulama ile karşılaştırmalı deneyler yapılmıştır. Geliştirilen sistemle, hem sıcak hem de soğuk uygulama için, tedavi edici sıcaklık aralığına daha çabuk ulaşıldığı, sıcaklığın tedavinin geri kalanı boyunca belirlenen sıcaklık değeri çevresinde küçük bir dalgalanma ile (±0.5°C) sabit tutulabildiği görülmüştür. Sistemin, teknik açıdan klinik uygulamalara imkân verecek yapıda olduğu sonucuna varılmıştır. Sistemin klinikte kullanımı, hasta ve fizyoterapistler açısından çeşitli avantajlar sağlayabilecek, yeni araştırmaların önünü açabilecektir.


  • Evaluation of Moro reflex with an objective method in late preterm and term infants

    by Deniz Anuk Ince, Ayşe Ecevit, Metin Yıldız, Ali Ulas Tugcu, Burak Ceran, Mustafa Agah Tekindal, Ozden Turan, Aylin Tarcan


  • Open Access

    A New PC-Based Text Entry System Based on EOG Coding

    by Metin Yildiz, Hesna Özbek Ülkütaş

    Some disadvantages of optical eye tracking systems have increased the interest to EOG (Electrooculography) based Human Computer Interaction (HCI). However, text entry attempts using EOG have been slower than expected because the eyes should move several times for entering a character. In order to improve the writing speed and accuracy of EOG based text entry, a new method based on the coding of eye movements has been suggested in this study. In addition, a real time EOG based HCI system has developed to implement the method. In our method all characters have been encoded by single saccades in 8 directions and different dwell time. In order to standardize dwell times and facilitate the coding process, computer assisted voice guidance was used. A number of experiments have been conducted to examine the effectiveness of the proposed method and system. At the end of the fifth trials, an experienced user was able to write at average 13.2 wpm (5 letters = 1 word) with 100% accuracy using the developed system. The results of our experiments have shown that text entry with the eye can be done quickly and efficiently with the proposed method and system.


  • Effect of spontaneous saliva swallowing on short‐term heart rate variability (HRV) and reliability of HRV analysis

    by Metin Yildiz, Serian Doma

    Summary: The effects of effortful swallowing and solid meal ingestions on heart rate variability (HRV) have been examined previously. The effects of spontaneous saliva swallowing on short‐term HRV and reliability of HRV analysis have not been studied before. The effect of saliva swallowing on HRV analyses parameters [meanRRI, SDNN (standard deviation of normal‐to‐normal), LF (low frequency), HF (high frequency) powers, LH/HF] and the reliability of LF and HF powers were investigated by frequency, time–frequency and intraclass correlation coefficient (ICC) analyses. Electrocardiogram and swallowing signal that obtained from an electronic stethoscope placed on the necks of subjects were recorded simultaneously from 30 healthy and young volunteers in sitting position during 15 min. Spontaneous swallowing has been shown to significantly alter some HRV parameters (SDNN, LF power and LF/HF ratio). Time‐frequency analysis results showed that the contribution of saliva swallowing to LF (1–58%) and HF (2–42%) powers could change significantly depending on the number of swallowing. The ICC of the LF and HF powers for the successive 5‐min signal segments were found 0·89, 0·92, respectively. These values decreased to 0·73 and 0·90 in the subjects with more swallowing rate. When the analyses were made for 2‐min signal periods, these values decreased to 0·63 and 0·67. We concluded that spontaneous saliva swallowing can change HRV parameters. We have also seen that changes in swallowing rate and use of short signal segments may reduce the reliability of HRV analyses.


  • Can Sleep Apnea be Detected by Heart Sounds?

    by Metin Yıldız, Zeynep Tabak, Sinan Yetkin