AMAndreas Carlos Meier

Andreas Carlos Meier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andreas Carlos Meier has a total of 100 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    Validation of Sentinel-5P TROPOMI tropospheric NO2 products by comparison with NO2 measurements from airborne imaging DOAS, ground-based stationary DOAS, and mobile car DOAS measurements during the S5P-VAL-DE-Ruhr campaign

    by Kezia Lange, Andreas Richter, Anja Schönhardt, Andreas C. Meier, Tim Bösch, André Seyler, Kai Krause, Lisa K. Behrens, Folkard Wittrock, Alexis Merlaud, et al.

    Airborne imaging differential optical absorption spectroscopy (DOAS), ground-based stationary DOAS, and car DOAS measurements were conducted during the S5P-VAL-DE-Ruhr campaign in September 2020. The campaign area is located in the Rhine-Ruhr region of North Rhine-Westphalia, western Germany, which is a pollution hotspot in Europe comprising urban and large industrial sources. The DOAS measurements are used to validate spaceborne NO2 tropospheric vertical column density (VCD) data products from the Sentinel-5 Precursor (S5P) TROPOspheric Monitoring Instrument (TROPOMI). Seven flights were performed with the airborne imaging DOAS instrument for measurements of atmospheric pollution (AirMAP), providing measurements that were used to create continuous maps of NO2 in the layer below the aircraft. These flights cover many S5P ground pixels within an area of 30 km × 35 km and were accompanied by ground-based stationary measurements and three mobile car DOAS instruments. Stationary measurements were conducted by two Pandora, two Zenith-DOAS, and two MAX-DOAS instruments. Ground-based stationary and car DOAS measurements are used to evaluate the AirMAP tropospheric NO2 VCDs and show high Pearson correlation coefficients of 0.88 and 0.89 and slopes of 0.90 ± 0.09 and 0.89 ± 0.02 for the stationary and car DOAS, respectively. Having a spatial resolution of about 100 m × 30 m, the AirMAP tropospheric NO2 VCD data create a link between the ground-based and the TROPOMI measurements with a nadir resolution of 3.5 km × 5.5 km and are therefore well suited to validate the TROPOMI tropospheric NO2 VCD. The observations on the 7 flight days show strong NO2 variability, which is dependent on the three target areas, the day of the week, and the meteorological conditions. The AirMAP campaign data set is compared to the TROPOMI NO2 operational offline (OFFL) V01.03.02 data product, the reprocessed NO2 data using the V02.03.01 of the official level-2 processor provided by the Product Algorithm Laboratory (PAL), and several scientific TROPOMI NO2 data products. The AirMAP and TROPOMI OFFL V01.03.02 data are highly correlated (r=0.87) but show an underestimation of the TROPOMI data with a slope of 0.38 ± 0.02 and a median relative difference of −9 %. With the modifications in the NO2 retrieval implemented in the PAL V02.03.01 product, the slope and median relative difference increased to 0.83 ± 0.06 and +20 %. However, the modifications resulted in larger scatter and the correlation decreased significantly to r=0.72. The results can be improved by not applying a cloud correction for the TROPOMI data in conditions with high aerosol load and when cloud pressures are retrieved close to the surface. The influence of spatially more highly resolved a priori NO2 vertical profiles and surface reflectivity are investigated using scientific TROPOMI tropospheric NO2 VCD data products. The comparison of the AirMAP campaign data set to the scientific data products shows that the choice of surface reflectivity database has a minor impact on the tropospheric NO2 VCD retrieval in the campaign region and season. In comparison, the replacement of the a priori NO2 profile in combination with the improvements in the retrieval of the PAL V02.03.01 product regarding cloud heights can further increase the tropospheric NO2 VCDs. This study demonstrates that the underestimation of the TROPOMI tropospheric NO2 VCD product with respect to the validation data set has been and can be further significantly improved.


  • Open Access

    Validation of Sentinel-5P TROPOMI tropospheric NO2 products by comparison with NO2 measurements from airborne imaging, ground-based stationary, and mobile car DOAS measurements during the S5P-VAL-DE-Ruhr campaign

    by Kezia Lange, Andreas Richter, Anja Schönhardt, Andreas C. Meier, Tim Bösch, André Seyler, Kai Krause, Lisa K. Behrens, Folkard Wittrock, Alexis Merlaud, et al.

    Airborne imaging differential optical absorption spectroscopy (DOAS), ground-based stationary and car DOAS measurements were conducted during the S5P-VAL-DE-Ruhr campaign in September 2020. The campaign area is located in the Rhine-Ruhr region of North Rhine-Westphalia, Western Germany, which is a pollution hotspot in Europe comprising urban and large industrial emitters. The measurements are used to validate space-borne NO2 tropospheric vertical column density data products from the Sentinel-5 Precursor (S5P) TROPOspheric Monitoring Instrument (TROPOMI). Seven flights were performed with the airborne imaging DOAS instrument for measurements of atmospheric pollution (AirMAP), providing measurements which were used to create continuous maps of NO2 in the layer below the aircraft. These flights cover many S5P ground pixels within an area of 30 km x 35 km and were accompanied by ground-based stationary measurements and three mobile car DOAS instruments. Stationary measurements were conducted by two Pandora, two zenith-sky and two MAX-DOAS instruments distributed over three target areas. Ground-based stationary and car DOAS measurements are used to evaluate the AirMAP tropospheric NO2 vertical column densities and show high Pearson correlation coefficients of 0.87 and 0.89 and slopes of 0.93 ± 0.09 and 0.98 ± 0.02 for the stationary and car DOAS, respectively. Having a spatial resolution of about 100 m x 30 m, the AirMAP tropospheric NO2 vertical column density (VCD) data creates a link between the ground-based and the TROPOMI measurements with a resolution of 3.5 km x 5.5 km and is therefore well suited to validate the TROPOMI tropospheric NO2 VCD. The measurements on the seven flight days show strong NO2 variability, which is dependent on the different target areas, the weekday, and the meteorological conditions. The AirMAP campaign dataset is compared to the TROPOMI NO2 operational off-line (OFFL) V01.03.02 data product, the reprocessed NO2 data, using the V02.03.01 of the official L2 processor, provided by the Product Algorithm Laboratory (PAL), and several scientific TROPOMI NO2 data products. The TROPOMI data products and the AirMAP data are highly correlated with correlation coefficients between 0.72 and 0.87, and slopes of 0.38 ± 0.02 to 1.02 ± 0.07. On average, TROPOMI tropospheric NO2 VCDs are lower than the AirMAP NO2 results. The slope increased from 0.38 ± 0.02 for the operational OFFL V01.03.02 product to 0.83 ± 0.06 after the improvements in the retrieval of the PAL V02.03.01 product were implemented. Different auxiliary data, such as spatially higher resolved a priori NO2 vertical profiles, surface reflectivity and the cloud treatment, are investigated using scientific TROPOMI tropospheric NO2 VCD data products to evaluate their impact on the operational TROPOMI NO2 VCD data product. The comparison of the AirMAP campaign dataset to the scientific data products shows that the choice of surface reflectivity data base has a minor impact on the tropospheric NO2 VCD retrieval in the campaign region and season. In comparison, the replacement of the a priori NO2 profile in combination with the improvements in the retrieval of the PAL V02.03.01 product regarding cloud heights has a major impact on the tropospheric NO2 VCD retrieval and increases the slope from 0.88 ± 0.06 to 1.00 ± 0.07. This study demonstrates that the underestimation of the TROPOMI tropospheric NO2 VCD product with respect to the validation dataset has been and can be further significantly improved.

  • Open Access

    Retrieval algorithm for OClO from TROPOMI (TROPOspheric Monitoring Instrument) by differential optical absorption spectroscopy

    by Jānis Puķīte, Christian Borger, Steffen Dörner, Myojeong Gu, Udo Frieß, Andreas Carlos Meier, Carl-Fredrik Enell, Uwe Raffalski, Andreas Richter, Thomas Wagner

    Here we present a new retrieval algorithm of the slant column densities (SCDs) of chlorine dioxide (OClO) by differential optical absorption spectroscopy (DOAS) from measurements performed by TROPOspheric Monitoring Instrument (TROPOMI) on board of Sentinel-5P satellite. To achieve a substantially improved accuracy, which is especially important for OClO observations, accounting for absorber and pseudo absorber structures in optical depth even of the order of 10−4 is important. Therefore, in comparison to existing retrievals, we include several additional fit parameters by accounting for spectral effects like the temperature dependency of the Ring effect and Ring absorption effects, a higher-order term for the OClO SCD dependency on wavelength and accounting for the BrO absorption. We investigate the performance of different retrieval settings by an error analysis with respect to random variations, large-scale systematic variations as a function of solar zenith angle and also more localized systematic variations by a novel application of an autocorrelation analysis. The retrieved TROPOMI OClO SCDs show a very good agreement with ground-based zenith sky measurements and are correlated well with preliminary data of the operational TROPOMI OClO retrieval algorithm currently being developed as part of ESA's Sentinel-5P+ Innovation project.


  • Open Access

    Retrieval algorithm for OClO from TROPOMI by Differential Optical Absorption Spectroscopy

    by Jānis Puķīte, Christian Borger, Steffen Dörner, Myojeong Gu, Udo Frieß, Andreas Carlos Maier, Carl-Fredrik Enell, Uwe Raffalksi, Andreas Richter, Thomas Wagner

    The TROPOspheric Monitoring Instrument (TROPOMI) is a UV-VIS-NIR-SWIR instrument on board of Sentinel-5P satellite developed for monitoring the Earth’s atmosphere. It was launched on 13 October 2017 in a near polar orbit. It measures spectrally resolved earthshine radiances at an unprecedented spatial resolution of around 3.5 x 7.2 km² (3.5 x 5.6 km² starting from 6 Aug 2019) (near nadir) with a total swath width of ~ 2600 km on the Earth's surface providing daily global coverage. From the measured spectra high resolved trace gas distributions can be retrieved by means of differential optical absorption spectroscopy (DOAS). Chlorine dioxide (OClO) is a by-product of the ozone depleting halogen chemistry in the stratosphere. Although being rapidly photolysed at low solar zenith angles (SZAs) it plays an important role as an indicator of the chlorine activation in polar regions during polar winter and spring at twilight conditions because of the nearly linear dependence of its formation to chlorine oxide (ClO). Here we present a new retrieval algorithm of the slant column densities (SCDs) of chlorine dioxide (OClO) by DOAS. To achieve a substantially improved accuracy, which is especially important for OClO observations, accounting for absorber and pseudo absorber structures in optical depth even of the order of 10−4 is important. Therefore in comparison to existing retrievals, we include several additional fit parameters accounting for spectral effects like the temperature dependency of the Ring effect and Ring absorption effects, higher order term for the OClO SCD dependency on wavelength and account for the BrO absorption. We investigate the performance of different retrieval settings by an error analysis with respect to random variations, large scale systematic variations as function of solar zenith angle and also more localised systematic variations by a novel application of an autocorrelation analysis. The retrieved TROPOMI OClO SCDs show a very good agreement with ground based zenith sky measurements and are correlated well with preliminary data of the opeartional TROPOMI OClO retrieval algorithm currently being developed as part of ESA's S5p+I project.

  • Open Access

    The Unusual Stratospheric Arctic Winter 2019/20: Chemical Ozone Loss From Satellite Observations and TOMCAT Chemical Transport Model

    by Mark Weber, Carlo Arosio, Wuhu Feng, Sandip S. Dhomse, Martyn P. Chipperfield, Andreas Meier, John P. Burrows, Kai‐Uwe Eichmann, Andreas Richter, Alexei Rozanov

    Satellite observations of relevant trace gases and meteorological data from ERA5 were used to describe the dynamics and chemistry of the spectacular Arctic 2019/20 winter/spring season. Exceptionally low total ozone values of slightly less than 220 DU were observed in mid‐March within an unusually large stratospheric polar vortex. Very high OClO and very low NO2 column amounts observed by GOME‐2A were indicative of unusually large active chlorine levels and significant denitrification, which likely contributed to large chemical ozone loss. Using results from the TOMCAT chemical transport model (CTM) and ozone observations from S5P/TROPOMI, GOME‐2 (total column), SCIAMACHY, and OMPS‐LP (vertical profiles), chemical ozone loss was evaluated and compared with the previous record Arctic winter 2010/11. The polar‐vortex‐averaged total column ozone loss in 2019/20 reached 88 DU (23%) and 106 DU (28%) based upon observations and model, respectively, by the end of March, which was similar to that derived for 2010/11. The maximum ozone loss (∼80%) observed by OMPS‐LP was near the 450 K potential temperature level (∼18 km altitude). Because of the larger polar vortex area in March 2020 compared to March 2011 (about 25% at 450 K), ozone mass loss was larger in Arctic winter 2019/20. It is shown that Arctic cap temperatures were at a record 40‐year low in winter, suggesting that Arctic cold winters are getting colder. Tropical UTLS temperatures show an apparent upward trend during the last two decades that may indicate a weakening of the Brewer‐Dobson circulation and strengthening of the polar vortex.


  • Open Access

    Retrieval of chlorine dioxide columns from Sentinel-5p observations

    by Andreas Carlos Meier, Andreas Richter, John P. Burrows, Gaia Pinardi, Michel Van Roozendael, Christian Retscher

    The Sentinel-5-precursor (S5p) satellite with the TROPOMI payload was launched on 13 October 2017. It is part of the European Copernicus program and provides a set of operational products of atmospheric constituents related to air quality and climate change with almost daily global coverage. The good signal to noise ratio of the instrument enables precise measurements despite the fine spatial resolution of 3.5 x 5.5 km2.The ESA S5p+ Innovation activity aims at extending the list of S5p products with scientific products, which are not yet part of the operational processor, to exploit the potential of the Sentinel-5p mission’s capabilities beyond its primary objectives. The retrieval of chlorine dioxide (OClO) from S5p is among the seven funded sub projects. Chlorine dioxide is an indicator for chlorine activation in the stratosphere and thus of importance for the understanding of stratospheric ozone chemistry, in particular in the polar vortex. Chlorine dioxide was retrieved from heritage instruments (GOME, SCIAMACHY, GOME2, OMI) and the S5p OClO product will act as a continuation of these time-series.Here we present the current status of the IUP-Bremen S5p OClO product developed within the ESA S5p+ Innovation framework. Based on a timeseries longer than 2 years, we demonstrate the good quality of the OClO dataset retrieved from S5p, which shows a high precision (~2.5x1013 molec/cm2) and a small offset (< 5x1012 molec/cm2) compared to heritage products. The comparison to a custom OClO product retrieved from OMI, shows good agreement in magnitude and seasonality, albeit the much larger noise in the OMI dataset. Validation to ground based data from high latitude stations shows excellent agreement.

  • Open Access

    Satellite validation strategy assessments based on the AROMAT campaigns

    by Alexis Merlaud, Livio Belegante, Daniel-Eduard Constantin, Mirjam Den Hoed, Andreas Carlos Meier, Marc Allaart, Magdalena Ardelean, Maxim Arseni, Tim Bösch, Hugues Brenot, et al.

    The Airborne ROmanian Measurements of Aerosols and Trace gases (AROMAT) campaigns took place in Romania in September 2014 and August 2015. They focused on two sites: the Bucharest urban area and large power plants in the Jiu Valley. The main objectives of the campaigns were to test recently developed airborne observation systems dedicated to air quality studies and to verify their applicability for the validation of space-borne atmospheric missions such as the TROPOspheric Monitoring Instrument (TROPOMI)/Sentinel-5 Precursor (S5P). We present the AROMAT campaigns from the perspective of findings related to the validation of tropospheric NO2, SO2, and H2CO. We also quantify the emissions of NOx and SO2 at both measurement sites. We show that tropospheric NO2 vertical column density (VCD) measurements using airborne mapping instruments are well suited for satellite validation in principle. The signal-to-noise ratio of the airborne NO2 measurements is an order of magnitude higher than its space-borne counterpart when the airborne measurements are averaged at the TROPOMI pixel scale. However, we show that the temporal variation of the NO2 VCDs during a flight might be a significant source of comparison error. Considering the random error of the TROPOMI tropospheric NO2 VCD (σ), the dynamic range of the NO2 VCDs field extends from detection limit up to 37 σ (2.6×1016 molec. cm−2) and 29 σ (2×1016 molec. cm−2) for Bucharest and the Jiu Valley, respectively. For both areas, we simulate validation exercises applied to the TROPOMI tropospheric NO2 product. These simulations indicate that a comparison error budget closely matching the TROPOMI optimal target accuracy of 25 % can be obtained by adding NO2 and aerosol profile information to the airborne mapping observations, which constrains the investigated accuracy to within 28 %. In addition to NO2, our study also addresses the measurements of SO2 emissions from power plants in the Jiu Valley and an urban hotspot of H2CO in the centre of Bucharest. For these two species, we conclude that the best validation strategy would consist of deploying ground-based measurement systems at well-identified locations.


  • Open Access

    The Sentinel-5 Precursor VAlidatioN and calibraTion Experiment (SVANTE)

    by Michel Van Roozendael, Frederik Tack, Alexis Merlaud, Dirk Schuettemeyer, Frank Hase, Andreas Richter, Andreas Meier, Mahesh Kumar Sha, Martine De Mazière, Arnoud Apituley, et al.

    Launched on 13 October 2017, Sentinel 5 Precursor (S-5p) is the first mission of the Copernicus Programme dedicated to the monitoring of air quality, climate, ozone and UV radiation. The S-5p characteristics, in particular its fine spatial resolution of 3.5 x 5.5 km2, introduce new opportunities for science and applications requiring to carefully assess the quality and validity of the generated data products by comparison with independent measurements and analyses.While the routine validation and QA/QC of the S-5p operational products is performed within the ESA Mission Performance Center (MPC) based on a limited number of Fiducial Reference Measurements (FRM), additional validation activities including field campaigns are conducted in research mode as part of the S-5p Validation Team (S5PVT). The validation activities bring together various teams and instruments and provide a more in-depth, complete insight into the S-5p instrument performance and the fitness for purpose of its data products.Here, we present observational deployments planned to take place in 2020-2021 in the context of the Sentinel 5p VAlidatioN and calibraTion Experiment (SVANTE). A first set of activities concentrates on the main S-5p UV-Vis tropospheric products (NO2, HCHO and SO2). Airborne measurements, including both in-situ spiral and remote sensing mapping flights, are planned over cities and industrial areas in Romania (Bucharest; Jiu valley), the German Ruhr area (Cologne; Duisburg; Dusseldorf) and Berlin, Belgium (Antwerp and Brussels), The Netherlands (Rotterdam and Cabauw), as well as the southern part of The Persian Gulf. These operations will be supported by ground-based measurements using Pandora, MAX-DOAS, car-DOAS, sun-photometer, ceilometer, lidar, etc. Over Berlin and Bucharest, the aim is to perform recurrent airborne observations with hyperspectral imagers in order to accumulate mapping data during approximately one full year, under variable meteorological and air quality conditions, as well as different satellite overpass configurations.A second set of activities will focus on the validation of the SWIR data products (CO and CH4). COCCON (COllaborative Carbon Column Observing Network) portable low-resolution EM27/SUN FTIR spectrometers will be deployed for an extended period at different sites in order to obtain a good coverage of geophysical parameters and different ground scenes.Additionally, synergies will be created with large field campaigns, such as the Asian Summer Monsoon Chemical and Climate Impact Project (ACCLIP) and the 2020 HYTES Joint European Campaign, which will provide airborne measurements of NO2, CO and CH4 columns and vertical profiles.The various airborne and ground-based measurements will produce a comprehensive ensemble of reference datasets. For each product, a core team will coordinate validation tasks, making use of data collected in all relevant instrumental deployments.

  • Open Access

    Retrieval of chlorine dioxide columns from Sentinel-5p observations

    by Andreas Carlos Meier, Andreas Richter, Gaia Pinardi, Michel Van Roozendael, John Philip Burrows

    The Sentinel-5-precursor (S5p) satellite with the TROPOMI payload was launched on 13 October 2017. It is part of the European Copernicus program and provides a set of operational products of atmospheric constituents related to air quality and climate change with almost daily global coverage. The good signal to noise ratio of the instrument enables precise measurements despite the fine spatial resolution of 3.5 x 5.5 km2. The ESA S5p+ Innovation activity aims at extending the list of S5p products with scientific products, which are not yet part of the operational processor, to exploit the potential of the Sentinel-5p mission’s capabilities beyond its primary objectives. The retrieval of chlorine dioxide (OClO) from S5p is among the seven funded sub projects. Chlorine dioxide is an indicator for chlorine activation in the stratosphere and thus of importance for the understanding of stratospheric ozone chemistry, in particular in the polar vortex. Chlorine dioxide was retrieved from heritage instruments (GOME, SCIAMACHY, GOME2, OMI) and the S5p OClO product will act as a continuation of these time-series.Here we present the current status of the IUP-Bremen S5p OClO product developed within the ESA S5p+ Innovation framework. The new S5p product will be put into context with products from previous and current (e.g. GOME-2c) satellite missions as well as ground-based measurements used for validation.

  • Open Access

    Supplementary material to "The Airborne ROmanian Measurements of Aerosols and Trace gases (AROMAT) campaigns"

    by Alexis Merlaud, Livio Belegante, Daniel-Eduard Constantin, Mirjam Den Hoed, Andreas Carlos Meier, Marc Allaart, Magdalena Ardelean, Maxim Arseni, Tim Bösch, Hugues Brenot, et al.