RSRoland Erwin Suri

Roland Erwin Suri

*This is an algorithmically generated author record based on publicly available information.

Roland Erwin Suri has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Lost in migration: document quality for batch conversion to PDF/A

    by Roland Erwin Suri, Mohamed El-Saad

    Purpose: Changes in file format specifications challenge long-term preservation of digital documents. Digital archives thus often focus on specific file formats that are well suited for long-term preservation, such as the PDF/A format. Since only few customers submit PDF/A files, digital archives may consider converting submitted files to the PDF/A format. The paper aims to discuss these issues. Design/methodology/approach: The authors evaluated three software tools for batch conversion of common file formats to PDF/A-1b: LuraTech PDF Compressor, Adobe Acrobat XI Pro and 3-HeightsTM Document Converter by PDF Tools. The test set consisted of 80 files, with 10 files each of the eight file types JPEG, MS PowerPoint, PDF, PNG, MS Word, MS Excel, MSG and “web page.” Findings: Batch processing was sometimes hindered by stops that required manual interference. Depending on the software tool, three to four of these stops occurred during batch processing of the 80 test files. Furthermore, the conversion tools sometimes failed to produce output files even for supported file formats: three (Adobe Pro) up to seven (LuraTech and 3-HeightsTM) PDF/A-1b files were not produced. Since Adobe Pro does not convert e-mails, a total of 213 PDF/A-1b files were produced. The faithfulness of each conversion was investigated by comparing the visual appearance of the input document with that of the produced PDF/A-1b document on a computer screen. Meticulous visual inspection revealed that the conversion to PDF/A-1b impaired the information content in 24 of the converted 213 files (11 percent). These reproducibility errors included loss of links, loss of other document content (unreadable characters, missing text, document part missing), updated fields (reflecting time and folder of conversion), vector graphics issues and spelling errors. Originality/value: These results indicate that large-scale batch conversions of heterogeneous files to PDF/A-1b cause complex issues that need to be addressed for each individual file. Even with considerable efforts, some information loss seems unavoidable if large numbers of files from heterogeneous sources are migrated to the PDF/A-1b format.


  • Scenes from the Past: MR Imaging versus CT of Ancient Peruvian and Egyptian Mummified Tissues

    by Lena Maria Öhrström, Hendrik von Waldburg, Peter Speier, Michael Bock, Roland Erwin Suri, Frank Jakobus Rühli

    Ancient Egyptian and Peruvian mummies are extremely valuable historical remains, and noninvasive methods for their examination are desirable. The current standard of reference for radiologic imaging of mummies is computed tomography (CT), with tissue having a homogeneous appearance on all CT images. It was long believed that ancient mummified tissue could not be studied with magnetic resonance (MR) imaging because of the low water content in mummies. Recently, however, the usefulness of MR imaging in the evaluation of mummified tissue was demonstrated for the first time, with use of a special ultrashort echo time technique. The authors of the present study acquired and analyzed MR imaging and CT data from the left hands of two ancient Egyptian mummies and the head of a third Egyptian mummy (ca 1500-1100 bce), as well as data from an ancient Peruvian mummy (ca 1100 ce). CT was found to provide superior detail of the anatomic structures, mainly because of its higher spatial resolution. The signal intensity of mummified tissue varied greatly on MR images; thus, the quality of these images is not yet comparable to that of clinical MR images, and further research will be needed to determine the full capacity of MR imaging in this setting. Nevertheless, additional information may theoretically be obtained with MR imaging, which should be viewed as complementary to, rather than a replacement for, CT.


  • Non-invasive continuous glucose monitoring: improved accuracy of point and trend estimates of the Multisensor system

    by Mattia Zanon, Giovanni Sparacino, Andrea Facchinetti, Michela Riz, Mark S. Talary, Roland E. Suri, Andreas Caduff, Claudio Cobelli

    Non-invasive continuous glucose monitoring (NI-CGM) sensors are still at an early stage of development, but, in the near future, they could become particularly appealing in diabetes management. Solianis Monitoring AG (Zurich, Switzerland) has proposed an approach for NI-CGM based on a multi-sensor concept, embedding primarily dielectric spectroscopy and optical sensors. This concept requires a mathematical model able to estimate glucose levels from the 150 channels directly measured through the Multisensor. A static multivariate linear regression model (with order and parameters common to the entire population of subjects) was proposed for such a scope (Caduff et al., Biosens Bioelectron 26:3794–3800, 2011). The aim of this work is to evaluate the accuracy in the estimation of glucose levels and trends that the NI-CGM Multisensor platform can achieve by exploiting different techniques for model identification, namely, ordinary least squares, subset variable selection, partial least squares and least absolute shrinkage and selection operator (LASSO). Data collected in human beings monitored for a total of 45 study days were used for model identification and model test. Several metrics of standard use in the diabetes scientific community to measure point and clinical accuracy of glucose sensors were used to assess the models. Results indicate that the LASSO technique is superior to the others shrinking many channel weights to zero thus leading to smoother glucose profiles and resulting in a more robust model to possible artifacts in the Multisensor data. Although, as expected, the performance of the NI-CGM system with the LASSO model is not yet comparable with that of enzyme-based needle glucose sensors, glucose trends are satisfactorily estimated. Considering the non-invasive nature of the multi-sensor platform, this result can have an immediate impact in the current clinical practice, e.g., to integrate sparse self-monitoring of blood glucose data with an indication of the glucose trend to aid the diabetic patient in dealing with, or even preventing in the short time scale, the threats of critical events such as hypoglycaemia.


  • Assessment of linear regression techniques for modeling multisensor data for non-invasive continuous glucose monitoring

    by Mattia Zanon, Michela Riz, Giovanni Sparacino, Andrea Facchinetti, Roland E. Suri, Mark S. Talary, Claudio Cobelli

    New scenarios in diabetes treatment have been opened in the last ten years by continuous glucose monitoring (CGM) sensors. In particular, Non-Invasive CGM sensors are particularly appealing, even though they are still at an early stage of development. Solianis Monitoring AG (Zürich, Switzerland) has proposed an approach based on a multisensor concept, embedding primarily dielectric spectroscopy and optical sensors. This concept requires a mathematical model able to reconstruct the glucose concentration from the 150 channels measured with the device. Assuming a multivariate linear regression model (valid and usable for different individuals), the aim of this paper is the assessment of some techniques usable for determining such a model, namely Ordinary Least Squares (OLS), Partial Least Squares (PLS) and Least Absolute Shrinkage and Selection Operator (LASSO). Once the model is identified on a training set, the accuracy of prospective glucose profiles estimated from ”unseen” multisensor data is assessed. Preliminary results obtained from 18 in-clinic study days show that sufficiently accurate reconstruction of glucose levels can be achieved if suitable model identification techniques, such as LASSO, are considered.


  • Characteristics of a multisensor system for non invasive glucose monitoring with external validation and prospective evaluation

    by Andreas Caduff, Martin Mueller, Alexander Megej, Francois Dewarrat, Roland E. Suri, Jelena Klisic, Marc Donath, Pavel Zakharov, Dominik Schaub, Werner A. Stahel, et al.


  • Comparison of scatter correction methods for CBCT

    by Roland E. Suri, Gary Virshup, Luis Zurkirchen, Wolfgang Kaissl

    In contrast to the narrow fan of clinical Computed Tomography (CT) scanners, Cone Beam scanners irradiate a much larger proportion of the object, which causes additional X-ray scattering. The most obvious scatter artefact is that the middle area of the object becomes darker than the outer area, as the density in the middle of the object is underestimated (cupping). Methods for estimating scatter were investigated that can be applied to each single projection without requiring a preliminary reconstruction. Scatter reduction by the Uniform Scatter Fraction method was implemented in the Varian CBCT software version 2.0. This scatter correction method is recommended for full fan scans using air norm. However, this method did not sufficiently correct artefacts in half fan scans and was not sufficiently robust if used in combination with a Single Norm. Therefore, a physical scatter model was developed that estimates scatter for each projection using the attenuation profile of the object. This model relied on laboratory experiments in which scatter kernels were measured for Plexiglas plates of varying thicknesses. Preliminary results suggest that this kernel model may solve the shortcomings of the Uniform Scatter Fraction model.


  • A computational framework for cortical learning

    by Roland E. Suri

    Recent physiological findings have revealed that long-term adaptation of the synaptic strengths between cortical pyramidal neurons depends on the temporal order of presynaptic and postsynaptic spikes, which is called spike-timing-dependent plasticity (STDP) or temporally asymmetric Hebbian (TAH) learning. Here I prove by analytical means that a physiologically plausible variant of STDP adapts synaptic strengths such that the presynaptic spikes predict the postsynaptic spikes with minimal error. This prediction error model of STDP implies a mechanism for cortical memory: cortical tissue learns temporal spike patterns if these spike patterns are repeatedly elicited in a set of pyramidal neurons. The trained network finishes these patterns if their beginnings are presented, thereby recalling the memory. Implementations of the proposed algorithms may be useful for applications in voice recognition and computer vision.


  • Spike propagation synchronized by temporally asymmetric Hebbian learning

    by Roland E. Suri, Terrence J. Sejnowski

    Synchronously spiking neurons have been observed in the cerebral cortex and the hippocampus. In computer models, synchronous spike volleys may be propagated across appropriately connected neuron populations. However, it is unclear how the appropriate synaptic connectivity is set up during development and maintained during adult learning. We performed computer simulations to investigate the influence of temporally asymmetric Hebbian synaptic plasticity on the propagation of spike volleys. In addition to feedforward connections, recurrent connections were included between and within neuron populations and spike transmission delays varied due to axonal, synaptic and dendritic transmission. We found that repeated presentations of input volleys decreased the synaptic conductances of intragroup and feedback connections while synaptic conductances of feedforward connections with short delays became stronger than those of connections with longer delays. These adaptations led to the synchronization of spike volleys as they propagated across neuron populations. The findings suggests that temporally asymmetric Hebbian learning may enhance synchronized spiking within small populations of neurons in cortical and hippocampal areas and familiar stimuli may produce synchronized spike volleys that are rapidly propagated across neural tissue.


  • Anticipatory responses of dopamine neurons and cortical neurons reproduced by internal model

    by Roland E. Suri

    Animals seem to learn and use internal models; they learn to anticipate predictable events, and their behavior in the sensory preconditioning paradigm reflects formation of novel associative chains. To investigate possible neural correlates, the temporal difference model (TD model) was extended to an internal model approach. The proposed model learns reward prediction error signals that resemble dopamine neuron activity. In contrast to the original TD model, the reward prediction error signals of the proposed model are influenced by the formation of novel associative chains in the sensory preconditioning experiment. This is consistent with experimental findings, as striatal dopamine concentration is influenced by the formation of novel associative chains in this paradigm. Comparison of the model architecture with biological neural networks suggests that chains of neurons with tonic anticipatory activity may underlie the formation of novel associative chains. These findings suggest that dopamine neuron activity may reflect the processing of an internal model.