Emmanuel Roux
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Emmanuel Roux has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Herve Liebgott
CNRS, Inserm, CREATIS UMR 5220, INSA-Lyon, Universit Lyon 1, Lyon, France
10 shared publications - Piero Tortoli
University of Florence
7 shared publications Christian Cachard
Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206 F-69621, Lyon, France
6 shared publications- Alessandro Ramalli
University of Florence
5 shared publications - Francois Varray
INSA-Lyon, Universite Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1294, Lyon, France
4 shared publications Lorena Petrusca
Univ Lyon, UJM-Saint-Etienne, INSA, CNRS UMR 5520, INSERM U1206, CREATIS, F-42023, Saint-Etienne, France
4 shared publications
Latest Publications
- Top Cited Papers
- 2 April 2026
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 281, 109341
Image pre-processing impact on generative model performance for Unsupervised Venous Malformation Segmentation
- 2 April 2026
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 281, 109341
Top Cited PapersImage pre-processing impact on generative model performance for Unsupervised Venous Malformation Segmentation
- 2 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
2D sparse array optimization and operating strategy for real-time 3D ultrasound imaging
Optimisation et pilotage de sondes parcimonieuses 2D pour l’imagerie ultrasonore 3D temps-réel: Aujourd'hui l'utilisation de l'échographie 3D en cardiologie est limitée car l'imagerie de la totalité du myocarde sur un cycle cardiaque, sans apnée, reste un défi technologique. Une solution consiste à réduire le nombre de capteurs dans les sondes échographiques matricielles afin d'alléger le procédé d'acquisition: ces sondes sont dites parcimonieuses. Le but de cette thèse est de proposer les meilleures dispositions d'un nombre réduit de capteurs piézo-électriques répartis sur la surface active de la sonde afin d'optimiser leur capacité à produire des images homogènes en termes de contraste et résolution dans tout le volume d'intérêt. Ce travail présente l'intégration de simulations acoustiques réalistes élaborées au sein d'un processus d'optimisation stochastique (algorithme de recuit simulé). La structure proposée pour le design des sondes parcimonieuse est suffisamment générale pour être appliquée aux sondes régulières (éléments actifs disposés selon une grille) et non-régulières (positionnement arbitraire des éléments actifs). L'introduction d'une fonction d'énergie innovante permet de sculpter en 3D le diagramme optimal de rayonnement de la sonde. Les résultats de sondes optimisées obtenues possèdent 128, 192 ou 256 éléments pour favoriser leur compatibilité avec les échographes commercialisés à ce jour, ce qui permettrait de déployer l'échographie 3D à moindre coût et à très large échelle
- 2 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
2D sparse array optimization and operating strategy for real-time 3D ultrasound imaging
Optimisation et pilotage de sondes parcimonieuses 2D pour l’imagerie ultrasonore 3D temps-réel: Aujourd'hui l'utilisation de l'échographie 3D en cardiologie est limitée car l'imagerie de la totalité du myocarde sur un cycle cardiaque, sans apnée, reste un défi technologique. Une solution consiste à réduire le nombre de capteurs dans les sondes échographiques matricielles afin d'alléger le procédé d'acquisition: ces sondes sont dites parcimonieuses. Le but de cette thèse est de proposer les meilleures dispositions d'un nombre réduit de capteurs piézo-électriques répartis sur la surface active de la sonde afin d'optimiser leur capacité à produire des images homogènes en termes de contraste et résolution dans tout le volume d'intérêt. Ce travail présente l'intégration de simulations acoustiques réalistes élaborées au sein d'un processus d'optimisation stochastique (algorithme de recuit simulé). La structure proposée pour le design des sondes parcimonieuse est suffisamment générale pour être appliquée aux sondes régulières (éléments actifs disposés selon une grille) et non-régulières (positionnement arbitraire des éléments actifs). L'introduction d'une fonction d'énergie innovante permet de sculpter en 3D le diagramme optimal de rayonnement de la sonde. Les résultats de sondes optimisées obtenues possèdent 128, 192 ou 256 éléments pour favoriser leur compatibilité avec les échographes commercialisés à ce jour, ce qui permettrait de déployer l'échographie 3D à moindre coût et à très large échelle
- Open Access
- 5 November 2025
- Published by Elsevier in Next Research
- Vol. 2 (4)
Deformation-aided lung segmentation: Introducing the DALS network for efficient learning
- 5 November 2025
- Published by Elsevier in Next Research
- Vol. 2 (4)
Open AccessDeformation-aided lung segmentation: Introducing the DALS network for efficient learning
- 25 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (8) , 1041-1052
Simulation, Design, and Characterization of a Large Divergent Element Sparse Array (LDESA) for 3-D Ultrasound Imaging
Sparse arrays address the complexity of manufacturing large 2D arrays. However, they usually suffer from a low signal-to-noise ratio (SNR) due to their small element size. The Large Divergent Element (LDE) technology overcomes this limitation by simultaneously having a large emitting area and a large angular aperture. The aim of this work is to demonstrate the feasibility of imaging in B-mode using the Large Divergent Element Sparse Array (LDESA), that is, increasing the sparse array SNR without noteworthy impact contrast. The paper provides the simulation, the design and an experimental characterization of a 1 MHz LDESA. Simulations are performed using the Angular Impulse Response based Ultrasound Simulation (AIRUS), providing coupled image-transducer optimizations of LDESA designs. Probe parameters, including probe diameter, layout, LDE size and electroacoustic response, are optimized to maximize the contrast ratio. The final layout is a 100 mm diameter Fermat spiral covered by 256 LDEs. Each LDE is 3.5mmwide in diameter and experimentally reaches an angular aperture of 75° at -6 dB in echo. The transmit focused beam is 1° wide and steerable up to 60° with an amplitude loss of only 10 dB. The array exhibits a 2.2 mm lateral resolution and a 1.8 mm axial resolution in a wire experiment.
- 25 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (8) , 1041-1052
Simulation, Design, and Characterization of a Large Divergent Element Sparse Array (LDESA) for 3-D Ultrasound Imaging
Sparse arrays address the complexity of manufacturing large 2D arrays. However, they usually suffer from a low signal-to-noise ratio (SNR) due to their small element size. The Large Divergent Element (LDE) technology overcomes this limitation by simultaneously having a large emitting area and a large angular aperture. The aim of this work is to demonstrate the feasibility of imaging in B-mode using the Large Divergent Element Sparse Array (LDESA), that is, increasing the sparse array SNR without noteworthy impact contrast. The paper provides the simulation, the design and an experimental characterization of a 1 MHz LDESA. Simulations are performed using the Angular Impulse Response based Ultrasound Simulation (AIRUS), providing coupled image-transducer optimizations of LDESA designs. Probe parameters, including probe diameter, layout, LDE size and electroacoustic response, are optimized to maximize the contrast ratio. The final layout is a 100 mm diameter Fermat spiral covered by 256 LDEs. Each LDE is 3.5mmwide in diameter and experimentally reaches an angular aperture of 75° at -6 dB in echo. The transmit focused beam is 1° wide and steerable up to 60° with an amplitude loss of only 10 dB. The array exhibits a 2.2 mm lateral resolution and a 1.8 mm axial resolution in a wire experiment.
- 15 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (6) , 772-785
A Deep Reinforcement Learning Based Region-Specific Beamformer for Sparse Arrays 3-D Ultrasound Imaging
Sparse arrays offer several advantages over other element reduction techniques for 3D ultrasound imaging. However, the large inter-element spacing in these arrays results in high sidelobe-related artifacts, which significantly degrade image quality and limit their application in 3D ultrasound imaging. Adaptive beamformers have been proposed to mitigate sidelobe-related artifacts, but they often degrade speckle texture quality, resulting in unnaturally dark images. To overcome these limitations, we propose RSB-Net, a region-specific beamformer based on deep reinforcement learning. RSB-Net adaptively selects the most suitable beamformer for each pixel of the image, applying adaptive beamforming in regions dominated by sidelobe artifacts and delay-and-sum beamforming in regions where speckle texture should be preserved. The effectiveness of RSB-Net was validated on both simulated and experimental synthetic transmit aperture RF datasets with a new designed sparse array prototype. On simulated data, RSB-Net achieved significant gains, with improvements of 52.81 dB in contrast ratio and 0.65 in generalized contrast-to-noise ratio compared to DAS beamforming. In experimental tissue-mimicking phantom data, RSB-Net demonstrated similar performance, achieving gains of 51.01 dB and 0.64 respectively. These results highlight the potential of RSB-Net as a robust and effective solution for high-quality B-mode 3D ultrasound imaging using 2D sparse arrays, advancing the standardization of 3D ultrasound in clinical settings by enhancing anatomical visualization, reducing operator dependency, and improving measurement accuracy for lesions and calcifications.
- 15 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (6) , 772-785
A Deep Reinforcement Learning Based Region-Specific Beamformer for Sparse Arrays 3-D Ultrasound Imaging
Sparse arrays offer several advantages over other element reduction techniques for 3D ultrasound imaging. However, the large inter-element spacing in these arrays results in high sidelobe-related artifacts, which significantly degrade image quality and limit their application in 3D ultrasound imaging. Adaptive beamformers have been proposed to mitigate sidelobe-related artifacts, but they often degrade speckle texture quality, resulting in unnaturally dark images. To overcome these limitations, we propose RSB-Net, a region-specific beamformer based on deep reinforcement learning. RSB-Net adaptively selects the most suitable beamformer for each pixel of the image, applying adaptive beamforming in regions dominated by sidelobe artifacts and delay-and-sum beamforming in regions where speckle texture should be preserved. The effectiveness of RSB-Net was validated on both simulated and experimental synthetic transmit aperture RF datasets with a new designed sparse array prototype. On simulated data, RSB-Net achieved significant gains, with improvements of 52.81 dB in contrast ratio and 0.65 in generalized contrast-to-noise ratio compared to DAS beamforming. In experimental tissue-mimicking phantom data, RSB-Net demonstrated similar performance, achieving gains of 51.01 dB and 0.64 respectively. These results highlight the potential of RSB-Net as a robust and effective solution for high-quality B-mode 3D ultrasound imaging using 2D sparse arrays, advancing the standardization of 3D ultrasound in clinical settings by enhancing anatomical visualization, reducing operator dependency, and improving measurement accuracy for lesions and calcifications.
- 26 November 2024
- Published by Elsevier in Pattern Recognition Letters
- Vol. 188, 37-45
An asymmetric heuristic for trained ternary quantization based on the statistics of the weights: An application to medical signal classification
- 26 November 2024
- Published by Elsevier in Pattern Recognition Letters
- Vol. 188, 37-45
An asymmetric heuristic for trained ternary quantization based on the statistics of the weights: An application to medical signal classification
- 18 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (3) , 1043-1055
Complete Complementary Coded Excitation Scheme for SNR Improvement of 2D Sparse Array Ultrasound Imaging
Driving the numerous elements of 2D matrix arrays for 3D ultrasound imaging is very challenging in terms of cable size, wiring and data rate. The sparse array approach tackles this problem by optimally distributing a reduced number of elements over a 2D aperture while preserving a decent image quality and beam steering capabilities. Unfortunately, reducing the number of elements significantly reduces the active probe footprint reducing as a consequence the sensitivity and at the end the signal-to-noise ratio. Here we propose a new coded excitation scheme based on complete complementary codes to increase the signal-to-noise ratio in 3D ultrasound imaging with sparse arrays. These codes are known for their ideal auto-correlation and cross-correlation properties and have been widely used in Code-Division Multiple Access systems (CDMA). An algorithm for generating such codes is presented as well as the adopted imaging sequence. The proposed method has been compared in simulations to other coded excitation schemes and showed significant increase in the signal-to-noise ratio of sparse arrays with no correlation artifacts and no frame rate reduction. The gain in signal-to-noise ratio compared to the case where no coded excitation is used was around ${\mathbf{\text{41.28}\,dB}}$ and the contrast was also improved by ${\mathbf{\text{29}\,dB}}$ while the resolution was unchanged.
- 18 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (3) , 1043-1055
Complete Complementary Coded Excitation Scheme for SNR Improvement of 2D Sparse Array Ultrasound Imaging
Driving the numerous elements of 2D matrix arrays for 3D ultrasound imaging is very challenging in terms of cable size, wiring and data rate. The sparse array approach tackles this problem by optimally distributing a reduced number of elements over a 2D aperture while preserving a decent image quality and beam steering capabilities. Unfortunately, reducing the number of elements significantly reduces the active probe footprint reducing as a consequence the sensitivity and at the end the signal-to-noise ratio. Here we propose a new coded excitation scheme based on complete complementary codes to increase the signal-to-noise ratio in 3D ultrasound imaging with sparse arrays. These codes are known for their ideal auto-correlation and cross-correlation properties and have been widely used in Code-Division Multiple Access systems (CDMA). An algorithm for generating such codes is presented as well as the adopted imaging sequence. The proposed method has been compared in simulations to other coded excitation schemes and showed significant increase in the signal-to-noise ratio of sparse arrays with no correlation artifacts and no frame rate reduction. The gain in signal-to-noise ratio compared to the case where no coded excitation is used was around ${\mathbf{\text{41.28}\,dB}}$ and the contrast was also improved by ${\mathbf{\text{29}\,dB}}$ while the resolution was unchanged.
- 1 April 2022
- Published by Elsevier in Medical Image Analysis
- Vol. 79, 102437
Semi-automatic data annotation based on feature-space projection and local quality metrics: An application to cerebral emboli characterization
- 1 April 2022
- Published by Elsevier in Medical Image Analysis
- Vol. 79, 102437
Semi-automatic data annotation based on feature-space projection and local quality metrics: An application to cerebral emboli characterization
- Top Cited PapersOpen Access
- 25 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (10) , 2739-2755
Design, Implementation, and Medical Applications of 2-D Ultrasound Sparse Arrays
An ultrasound sparse array consists of a sparse distribution of elements over a 2-D aperture. Such an array is typically characterized by a limited number of elements, which in most cases is compatible with the channel number of the available scanners. Sparse arrays represent an attractive alternative to full 2-D arrays that may require the control of thousands of elements through expensive application-specific integrated circuits (ASICs). However, their massive use is hindered by two main drawbacks: the possible beam profile deterioration, which may worsen the image contrast, and the limited signal-to-noise ratio (SNR), which may result too low for some applications. This article reviews the work done for three decades on 2-D ultrasound sparse arrays for medical applications. First, random, optimized, and deterministic design methods are reviewed together with their main influencing factors. Then, experimental 2-D sparse array implementations based on piezoelectric and capacitive micromachined ultrasonic transducer (CMUT) technologies are presented. Sample applications to 3-D (Doppler) imaging, super-resolution imaging, photo-acoustic imaging, and therapy are reported. The final sections discuss the main shortcomings associated with the use of sparse arrays, the related countermeasures, and the next steps envisaged in the development of innovative arrays.
- 25 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (10) , 2739-2755
Top Cited PapersOpen AccessDesign, Implementation, and Medical Applications of 2-D Ultrasound Sparse Arrays
An ultrasound sparse array consists of a sparse distribution of elements over a 2-D aperture. Such an array is typically characterized by a limited number of elements, which in most cases is compatible with the channel number of the available scanners. Sparse arrays represent an attractive alternative to full 2-D arrays that may require the control of thousands of elements through expensive application-specific integrated circuits (ASICs). However, their massive use is hindered by two main drawbacks: the possible beam profile deterioration, which may worsen the image contrast, and the limited signal-to-noise ratio (SNR), which may result too low for some applications. This article reviews the work done for three decades on 2-D ultrasound sparse arrays for medical applications. First, random, optimized, and deterministic design methods are reviewed together with their main influencing factors. Then, experimental 2-D sparse array implementations based on piezoelectric and capacitive micromachined ultrasonic transducer (CMUT) technologies are presented. Sample applications to 3-D (Doppler) imaging, super-resolution imaging, photo-acoustic imaging, and therapy are reported. The final sections discuss the main shortcomings associated with the use of sparse arrays, the related countermeasures, and the next steps envisaged in the development of innovative arrays.
- Open Access
- 14 June 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-12
Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves
Three dimensional ultrasound (3-D US) imaging methods based on 2-D array probes are increasingly investigated. However, the experimental test of new 3-D US approaches is contrasted by the need of controlling very large numbers of probe elements. Although this problem may be overcome by the use of 2-D sparse arrays, just a few experimental results have so far corroborated the validity of this approach. In this paper, we experimentally compare the performance of a fully wired 1024-element (32 × 32) array, assumed as reference, to that of a 256-element random and of an “optimized” 2-D sparse array, in both focused and compounded diverging wave (DW) transmission modes. The experimental results in 3-D focused mode show that the resolution and contrast produced by the optimized sparse array are close to those of the full array while using 25% of elements. Furthermore, the experimental results in 3-D DW mode and 3-D focused mode are also compared for the first time and they show that both the contrast and the resolution performance are higher when using the 3-D DW at volume rates up to 90/second which represent a 36x speed up factor compared to the focused mode.
- 14 June 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-12
Open AccessExperimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves
Three dimensional ultrasound (3-D US) imaging methods based on 2-D array probes are increasingly investigated. However, the experimental test of new 3-D US approaches is contrasted by the need of controlling very large numbers of probe elements. Although this problem may be overcome by the use of 2-D sparse arrays, just a few experimental results have so far corroborated the validity of this approach. In this paper, we experimentally compare the performance of a fully wired 1024-element (32 × 32) array, assumed as reference, to that of a 256-element random and of an “optimized” 2-D sparse array, in both focused and compounded diverging wave (DW) transmission modes. The experimental results in 3-D focused mode show that the resolution and contrast produced by the optimized sparse array are close to those of the full array while using 25% of elements. Furthermore, the experimental results in 3-D DW mode and 3-D focused mode are also compared for the first time and they show that both the contrast and the resolution performance are higher when using the 3-D DW at volume rates up to 90/second which represent a 36x speed up factor compared to the focused mode.