Lechun Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lechun Xie has a total of 109 co-authors. Here are the top co-authors by number of shared publications:
Liqiang Wang
State Key Laboratory of Metal Matrix Composites School of Materials Science and Engineering Shanghai Jiao Tong University Shanghai 200240 P. R. China
22 shared publicationsYan Wen
State Key Laboratory of Light Superalloys Wuhan University of Technology Wuhan China
17 shared publicationsLin Hua
15 shared publicationsJian Zhou
14 shared publicationsWeijie Lu
10 shared publicationsYaya Wu
10 shared publications
Latest Publications
- Open Access
- 1 December 2026
- Published by KEAI Publishing in Advanced Light Materials
- Vol. 1 (2) , 189-202
Microstructure regulation and plasticity improvement of TiAl4822 alloy via electroshock treatment
- 1 December 2026
- Published by KEAI Publishing in Advanced Light Materials
- Vol. 1 (2) , 189-202
Open AccessMicrostructure regulation and plasticity improvement of TiAl4822 alloy via electroshock treatment
- Open Access
- 5 August 2026
- Published by Wiley in Advanced Engineering Materials
- Vol. 28 (18) , e71094
Evolution Mechanism of Microstructure and Electrical Conductivity of Laser Directed Energy Deposition (TC4 + TiC)/CuCrZr Under Electroshock Treatment
This study addresses issues such as cracking and deterioration of electrical conductivity in laser directed energy deposition (LDED) on copper alloy surfaces, proposing a synergistic process combining surface pretreatment with electroshock treatment (EST). An Ti‐6Al‐4V(TC4) + TiC composite coating was manufactured on a CuCrZr substrate via LDED. The effects of three substrate surface conditions—cold‐sprayed Ti, shot peening, and unprocessed—on the interfacial bonding quality of the cladding layer were systematically investigated. Analyzing EST mechanisms for enhancing interfacial microstructure reconstruction and electrical conductivity. The results indicated that the cold‐sprayed Ti pretreatment, by providing a transition layer, achieving the most continuous and dense bonding interface. EST significantly promoted the interdiffusion of Cu and Ti elements at the interface, widening the transition zone. The microscopic electrical resistance of the sample treated with EST for 0.1 s showed a maximum reduction of 69.09%, because of EST induced fragmentation and spheroidization of the continuous brittle Cu–Ti intermetallic compounds (IMCs) layer, promoted the precipitation of fine and dispersed Cu 4 Ti phases, increased lattice distortion, and healed microcracks. This research provided a novel technological approach and theoretical basis for manufacturing high‐strength, high‐conductivity titanium matrix composites (TMCs) coating on copper alloys.
- 5 August 2026
- Published by Wiley in Advanced Engineering Materials
- Vol. 28 (18) , e71094
Open AccessEvolution Mechanism of Microstructure and Electrical Conductivity of Laser Directed Energy Deposition (TC4 + TiC)/CuCrZr Under Electroshock Treatment
This study addresses issues such as cracking and deterioration of electrical conductivity in laser directed energy deposition (LDED) on copper alloy surfaces, proposing a synergistic process combining surface pretreatment with electroshock treatment (EST). An Ti‐6Al‐4V(TC4) + TiC composite coating was manufactured on a CuCrZr substrate via LDED. The effects of three substrate surface conditions—cold‐sprayed Ti, shot peening, and unprocessed—on the interfacial bonding quality of the cladding layer were systematically investigated. Analyzing EST mechanisms for enhancing interfacial microstructure reconstruction and electrical conductivity. The results indicated that the cold‐sprayed Ti pretreatment, by providing a transition layer, achieving the most continuous and dense bonding interface. EST significantly promoted the interdiffusion of Cu and Ti elements at the interface, widening the transition zone. The microscopic electrical resistance of the sample treated with EST for 0.1 s showed a maximum reduction of 69.09%, because of EST induced fragmentation and spheroidization of the continuous brittle Cu–Ti intermetallic compounds (IMCs) layer, promoted the precipitation of fine and dispersed Cu 4 Ti phases, increased lattice distortion, and healed microcracks. This research provided a novel technological approach and theoretical basis for manufacturing high‐strength, high‐conductivity titanium matrix composites (TMCs) coating on copper alloys.
- Open Access
- 12 May 2026
- Published by Taylor & Francis in Virtual and Physical Prototyping
- Vol. 21 (1)
Machine learning-assisted optimisation of direct energy deposition for high wear-resistant TiC-reinforced coating on CuCrZr surface
- 12 May 2026
- Published by Taylor & Francis in Virtual and Physical Prototyping
- Vol. 21 (1)
Open AccessMachine learning-assisted optimisation of direct energy deposition for high wear-resistant TiC-reinforced coating on CuCrZr surface
- 12 May 2026
- Published by Wiley in Advanced Engineering Materials
- Vol. 28 (13)
Development of High‐Performance Blade Materials and Advanced Manufacturing Technologies
As a key component of turbomachinery, the performance of blades directly determines the efficiency, service life and reliability of the entire machine. In recent years, with the development of energy equipment toward higher temperature, higher pressure, higher rotation speed and lighter weight, the higher requirements have been put forward for blade materials and manufacturing processes. This paper systematically reviews the development of blade materials, including the evolution from heat‐resistant steel and stainless steel to nickel‐based superalloys, titanium alloys, titanium‐aluminum alloys, and then to high‐temperature composite materials. It summarizes the principles, advantages and limitations of major manufacturing methods such as casting, forging, powder metallurgy (PM), additive manufacturing (AM), and electrochemical machining (ECM). Moreover, it analyzes the matching performance and applicable scenarios of different materials and manufacturing processes. Most existing reviews focus on a single material or manufacturing process and lack a cross‐cutting analysis of the material‐process synergistic mechanism. On this basis, future development trends such as multimaterial integration, digital manufacturing, in‐service repairability and breakthroughs in ultrahigh‐temperature materials are proposed, aiming to provide references for the optimization of blade design and manufacturing.
- 12 May 2026
- Published by Wiley in Advanced Engineering Materials
- Vol. 28 (13)
Development of High‐Performance Blade Materials and Advanced Manufacturing Technologies
As a key component of turbomachinery, the performance of blades directly determines the efficiency, service life and reliability of the entire machine. In recent years, with the development of energy equipment toward higher temperature, higher pressure, higher rotation speed and lighter weight, the higher requirements have been put forward for blade materials and manufacturing processes. This paper systematically reviews the development of blade materials, including the evolution from heat‐resistant steel and stainless steel to nickel‐based superalloys, titanium alloys, titanium‐aluminum alloys, and then to high‐temperature composite materials. It summarizes the principles, advantages and limitations of major manufacturing methods such as casting, forging, powder metallurgy (PM), additive manufacturing (AM), and electrochemical machining (ECM). Moreover, it analyzes the matching performance and applicable scenarios of different materials and manufacturing processes. Most existing reviews focus on a single material or manufacturing process and lack a cross‐cutting analysis of the material‐process synergistic mechanism. On this basis, future development trends such as multimaterial integration, digital manufacturing, in‐service repairability and breakthroughs in ultrahigh‐temperature materials are proposed, aiming to provide references for the optimization of blade design and manufacturing.
- 16 January 2026
- Published by Wiley in Advanced Engineering Materials
- Vol. 28 (4)
Repairing Mechanism of Fatigue Defects in TiB/Ti‐6Al‐4V Titanium Matrix Composite via Electroshock Treatment
Titanium matrix composites (TMCs) can be used in some important industrial fields, and they are easy to generate the defects during loading. It is significant to modify the microstructure and repair the defects. In this article, the microstructure of secondary α (α s ) phase precipitated from the β phase via electroshock treatment (EST) in TiB/Ti‐6Al‐4V. The orientation of α phase and TiB varied, the maximum texture intensity of α phase decreased, and the orientation became more uniform. The maximum texture intensity of TiB increased. After EST, the yield strength of TiB/Ti‐6Al‐4V increased by 1345.7 MPa, the compressive fracture strain is 20.5%, and the hardness value is 420.4 HV. During the process of fatigue failure, the tips of TiB are easy to form micropores and defects. However, the fatigue defects can be repaired by EST, and the volume rate of repairing defects reached 73.94%–82.17%. All results indicate EST is an efficient method to repair defects and improve mechanical properties of TMCs.
- 16 January 2026
- Published by Wiley in Advanced Engineering Materials
- Vol. 28 (4)
Repairing Mechanism of Fatigue Defects in TiB/Ti‐6Al‐4V Titanium Matrix Composite via Electroshock Treatment
Titanium matrix composites (TMCs) can be used in some important industrial fields, and they are easy to generate the defects during loading. It is significant to modify the microstructure and repair the defects. In this article, the microstructure of secondary α (α s ) phase precipitated from the β phase via electroshock treatment (EST) in TiB/Ti‐6Al‐4V. The orientation of α phase and TiB varied, the maximum texture intensity of α phase decreased, and the orientation became more uniform. The maximum texture intensity of TiB increased. After EST, the yield strength of TiB/Ti‐6Al‐4V increased by 1345.7 MPa, the compressive fracture strain is 20.5%, and the hardness value is 420.4 HV. During the process of fatigue failure, the tips of TiB are easy to form micropores and defects. However, the fatigue defects can be repaired by EST, and the volume rate of repairing defects reached 73.94%–82.17%. All results indicate EST is an efficient method to repair defects and improve mechanical properties of TMCs.
- Open Access
- 15 December 2025
- Published by Frontiers Media SA in Frontiers in Materials
- Vol. 12, 1756188
Editorial: Metallic biomaterials for medical applications - volume II
Germ agglutinin staining, is reduced on UV-LIPSS Ti6Al7Nb. Together, these results support a design strategy in which surface nano-patterning alone, without altering bulk alloy chemistry, can both promote osseointegration and reduce bacterial colonisation on orthopaedic implants. Luo et al. extended the design freedom from the surface to the whole by combining alloys with additive manufacturing used for guided bone regeneration (GBR). Luo et al. use selective laser melting to fabricate Ti-xCu meshes (x = 0, 4, 6, 8 wt%) tailored for personalized GBR in dental implantology. Increasing Cu content promotes Ti₂Cu precipitation in the α-Ti matrix and increases copper ion release, but without sacrificing corrosion resistance in physiological media. Alloys containing more than 4 wt% Cu achieve over 90% reduction of S. aureus and E. coli, while Ti-6Cu, in particular, balances high antibacterial efficacy with favourable osteoblast proliferation, up-regulation of osteogenic genes, and an anti-inflammatory shift in macrophage-related markers. This work exemplifies how composition-microstructure design can be leveraged to integrate antibacterial and immunomodulatory functions into load-bearing metallic meshes for complex maxillofacial defects.Stress shielding at the bone-implant interface remains a central concern in orthopaedics, especially as porous, lattice-like designs become mainstream. Amadasi et al. address this issue with an integrated experimental and analytical framework that quantifies how porous metal scaffolds share load with cortical bone. Using bovine cortical bone blocks with machined cavities housing CoCrMo or Ti6Al4V scaffolds (porous or full-density), the authors combine axial compression tests, digital image correlation, finite element analysis, and a spring-based analytical model to resolve strain distributions in the bone. Porous scaffolds drive bone strain patterns closer to those of intact bone than full-density inserts, confirming their potential to mitigate stress shielding. Within this space, Ti6Al4V scaffolds provide more favourable reaction forces and strain transfer than CoCrMo, and scaffolds with 1,000 μm pores outperform 500 μm pores in restoring physiologic load transfer. These insights offer practical guidance for selecting both material and pore architecture in next-generation joint and spine implants.The Topic also highlights the opportunities and pitfalls of degradable metallic devices in the vascular system. Oliver et al. report a brief research study on braided bioresorbable flow diverters (BRFDs) fabricated from an iron-manganese-nitrogen (FeMnN) alloy, evaluated in the rabbit elastase-induced aneurysm model. In a rabbit elastase-induced aneurysm model, FeMnN BRFDs are deployed and followed for 3 months. Despite earlier benchtop data showing adequate radial strength, flow diversion and MRI compatibility, most aneurysms remain incompletely occluded at the study endpoint. Angiography, gross inspection and histology reveal that the FeMnN wires resorb and fragment too rapidly at the aneurysm neck, so that the braid loses mechanical continuity before a stable neointimal layer can fully seal the aneurysm. Importantly, where FeMnN wires persist they are well integrated into neotissue, indicating that the alloy is biologically acceptable and that the limitation is primarily a resorption-mechanics mismatch rather than a failure of tissue healing. As such, this"negative"in vivo outcome is a constructive boundary condition for future designs, emphasising that wire diameter, braid architecture and corrosion kinetics must be co-optimised to align scaffold persistence with the 6-12-month time window typically required for intracranial aneurysm occlusion.Taken together, the four contributions in Metallic Biomaterials for Medical Applications -Volume II illustrate a coherent design philosophy for metallic implants. UV-LIPSS surface engineering offers a purely physical, contamination-free route to improve bone-implant integration and reduce biofilm formation on established titanium alloys. Compositionally tailored, 3D-printed Ti-Cu meshes demonstrate how additive manufacturing can encode antibacterial and immunomodulatory behaviour into patient-specific dental devices. Mechanically informed studies of porous Ti6Al4V and CoCrMo scaffolds clarify how pore size, porosity and alloy stiffness govern load transfer and strain fields in cortical bone, with direct implications for long-term bone preservation. Finally, the FeMnN BRFD work illustrates that degradability per se is not an advantage unless the degradation profile is carefully matched to the biomechanics and healing timelines of the target vascular bed.Although the authors contributing to this Topic work in Germany, Italy, China and the United States, the clinical questions they address are truly global. For example, ageing populations and high rates of osteoporosis-related fragility fractures in Latin America are expected to increase the demand for joint replacement and fracture fixation, often in health systems with constrained resources. In such settings, robust metallic implants that resist infection, preserve bone stock and avoid costly revision surgery are particularly valuable. Similarly, dental implantology in regions such as Brazil and other parts of Latin America must contend with population-specific bone density distributions and variable access to advanced imaging and customised devices, reinforcing the importance of designs that are both biofunctional and cost-effective. Collaborations that link centres with strong biomaterials research capabilities in Europe, Asia, North America and Latin America will therefore be essential to translate the concepts showcased in this Topic into widely accessible clinical solutions.Looking ahead, several concrete directions emerge. First, there is a need for multi-objective optimisation frameworks that treat alloy composition, processing parameters,...
- 15 December 2025
- Published by Frontiers Media SA in Frontiers in Materials
- Vol. 12, 1756188
Open AccessEditorial: Metallic biomaterials for medical applications - volume II
Germ agglutinin staining, is reduced on UV-LIPSS Ti6Al7Nb. Together, these results support a design strategy in which surface nano-patterning alone, without altering bulk alloy chemistry, can both promote osseointegration and reduce bacterial colonisation on orthopaedic implants. Luo et al. extended the design freedom from the surface to the whole by combining alloys with additive manufacturing used for guided bone regeneration (GBR). Luo et al. use selective laser melting to fabricate Ti-xCu meshes (x = 0, 4, 6, 8 wt%) tailored for personalized GBR in dental implantology. Increasing Cu content promotes Ti₂Cu precipitation in the α-Ti matrix and increases copper ion release, but without sacrificing corrosion resistance in physiological media. Alloys containing more than 4 wt% Cu achieve over 90% reduction of S. aureus and E. coli, while Ti-6Cu, in particular, balances high antibacterial efficacy with favourable osteoblast proliferation, up-regulation of osteogenic genes, and an anti-inflammatory shift in macrophage-related markers. This work exemplifies how composition-microstructure design can be leveraged to integrate antibacterial and immunomodulatory functions into load-bearing metallic meshes for complex maxillofacial defects.Stress shielding at the bone-implant interface remains a central concern in orthopaedics, especially as porous, lattice-like designs become mainstream. Amadasi et al. address this issue with an integrated experimental and analytical framework that quantifies how porous metal scaffolds share load with cortical bone. Using bovine cortical bone blocks with machined cavities housing CoCrMo or Ti6Al4V scaffolds (porous or full-density), the authors combine axial compression tests, digital image correlation, finite element analysis, and a spring-based analytical model to resolve strain distributions in the bone. Porous scaffolds drive bone strain patterns closer to those of intact bone than full-density inserts, confirming their potential to mitigate stress shielding. Within this space, Ti6Al4V scaffolds provide more favourable reaction forces and strain transfer than CoCrMo, and scaffolds with 1,000 μm pores outperform 500 μm pores in restoring physiologic load transfer. These insights offer practical guidance for selecting both material and pore architecture in next-generation joint and spine implants.The Topic also highlights the opportunities and pitfalls of degradable metallic devices in the vascular system. Oliver et al. report a brief research study on braided bioresorbable flow diverters (BRFDs) fabricated from an iron-manganese-nitrogen (FeMnN) alloy, evaluated in the rabbit elastase-induced aneurysm model. In a rabbit elastase-induced aneurysm model, FeMnN BRFDs are deployed and followed for 3 months. Despite earlier benchtop data showing adequate radial strength, flow diversion and MRI compatibility, most aneurysms remain incompletely occluded at the study endpoint. Angiography, gross inspection and histology reveal that the FeMnN wires resorb and fragment too rapidly at the aneurysm neck, so that the braid loses mechanical continuity before a stable neointimal layer can fully seal the aneurysm. Importantly, where FeMnN wires persist they are well integrated into neotissue, indicating that the alloy is biologically acceptable and that the limitation is primarily a resorption-mechanics mismatch rather than a failure of tissue healing. As such, this"negative"in vivo outcome is a constructive boundary condition for future designs, emphasising that wire diameter, braid architecture and corrosion kinetics must be co-optimised to align scaffold persistence with the 6-12-month time window typically required for intracranial aneurysm occlusion.Taken together, the four contributions in Metallic Biomaterials for Medical Applications -Volume II illustrate a coherent design philosophy for metallic implants. UV-LIPSS surface engineering offers a purely physical, contamination-free route to improve bone-implant integration and reduce biofilm formation on established titanium alloys. Compositionally tailored, 3D-printed Ti-Cu meshes demonstrate how additive manufacturing can encode antibacterial and immunomodulatory behaviour into patient-specific dental devices. Mechanically informed studies of porous Ti6Al4V and CoCrMo scaffolds clarify how pore size, porosity and alloy stiffness govern load transfer and strain fields in cortical bone, with direct implications for long-term bone preservation. Finally, the FeMnN BRFD work illustrates that degradability per se is not an advantage unless the degradation profile is carefully matched to the biomechanics and healing timelines of the target vascular bed.Although the authors contributing to this Topic work in Germany, Italy, China and the United States, the clinical questions they address are truly global. For example, ageing populations and high rates of osteoporosis-related fragility fractures in Latin America are expected to increase the demand for joint replacement and fracture fixation, often in health systems with constrained resources. In such settings, robust metallic implants that resist infection, preserve bone stock and avoid costly revision surgery are particularly valuable. Similarly, dental implantology in regions such as Brazil and other parts of Latin America must contend with population-specific bone density distributions and variable access to advanced imaging and customised devices, reinforcing the importance of designs that are both biofunctional and cost-effective. Collaborations that link centres with strong biomaterials research capabilities in Europe, Asia, North America and Latin America will therefore be essential to translate the concepts showcased in this Topic into widely accessible clinical solutions.Looking ahead, several concrete directions emerge. First, there is a need for multi-objective optimisation frameworks that treat alloy composition, processing parameters,...
- Open Access
- 28 November 2025
- Published by AccScience Publishing in Engineering Science in Additive Manufacturing
- Vol. 1 (4) , 025430030
Effect of electroshock treatment on microstructure evolution of Ti-6Al-4V/Cu-Cr-Zr interface fabricated by laser melting deposition
This study aims to examine the effect of electroshock treatment (EST) on Ti-6Al-4V/Cu-Cr-Zr manufactured by laser melting deposition and explore the microstructure and mechanical properties to investigate the microstructure evolution of copper-based rail composite materials under high-energy-density currents. The results indicated that EST could promote atomic diffusion, enabling rapid preferential growth of TiCu in the metallurgical bonding zone. An increase of the current density promoted the nucleation of the primary Ti2Cu phase induced by the thermal effect of EST, which led to Cu solute enrichment and composition undercooling. Moreover, EST significantly improved nucleation rate and grain boundary migration. The average β grain size of the EST-1 sample increased from 2.83 μm to 3.62 μm, approximately, while the typical basic texture of EST-1 was enhanced. In EST-1, the shear strength of Ti-6Al-4V/Cu-Cr-Zr was 132 MPa, which was 65% higher than that of the original Ti-6Al-4V/Cu-Cr-Zr composite. The improvement in shear strength can be attributed to intergranular nano-precipitation and the improved wettability of Ti-6Al-4V/Cu-Cr-Zr. This work provides valuable insights into the preparation of high-value, high-performance Cu-based composites.
- 28 November 2025
- Published by AccScience Publishing in Engineering Science in Additive Manufacturing
- Vol. 1 (4) , 025430030
Open AccessEffect of electroshock treatment on microstructure evolution of Ti-6Al-4V/Cu-Cr-Zr interface fabricated by laser melting deposition
This study aims to examine the effect of electroshock treatment (EST) on Ti-6Al-4V/Cu-Cr-Zr manufactured by laser melting deposition and explore the microstructure and mechanical properties to investigate the microstructure evolution of copper-based rail composite materials under high-energy-density currents. The results indicated that EST could promote atomic diffusion, enabling rapid preferential growth of TiCu in the metallurgical bonding zone. An increase of the current density promoted the nucleation of the primary Ti2Cu phase induced by the thermal effect of EST, which led to Cu solute enrichment and composition undercooling. Moreover, EST significantly improved nucleation rate and grain boundary migration. The average β grain size of the EST-1 sample increased from 2.83 μm to 3.62 μm, approximately, while the typical basic texture of EST-1 was enhanced. In EST-1, the shear strength of Ti-6Al-4V/Cu-Cr-Zr was 132 MPa, which was 65% higher than that of the original Ti-6Al-4V/Cu-Cr-Zr composite. The improvement in shear strength can be attributed to intergranular nano-precipitation and the improved wettability of Ti-6Al-4V/Cu-Cr-Zr. This work provides valuable insights into the preparation of high-value, high-performance Cu-based composites.
- 29 October 2025
- Published by Wiley in Advanced Engineering Materials
- Vol. 27 (23)
Improving Mechanical Properties of M50 Steel via Martensite Transformation and Carbide Precipitation Under Electromagnetic Shock Treatment
As a new type of material post‐treatment method, electromagnetic shock treatment (EMST) shows the advantages of high‐energy utilization rate, short time consumption, and the ability to perform local treatment. This treatment method can provide new technologies and theoretical guidance for the high‐performance manufacturing of bearings and can be used to regulate the microstructure and mechanical properties of bearings. In this article, the tempered M50 steel (8Cr4Mo4V) is selected as the research object to explore the influence mechanism of EMST on its microstructure (grain size, grain orientation, texture, dislocation density) and mechanical properties (hardness, compressive strength). Microstructure observation results show that the original austenite grain boundaries became blurred after EMST. The acicular martensite is formed, accompanied by the precipitation of lath carbides and short‐rod carbides. The average KAM values decrease from 0.95° to 0.67° after EMST. The results of mechanical tests show that the hardness of the sample after EMST increases from 316.7 to 333.8 HV, and the compressive yield strength increases from 1611 to 1899 MPa. These findings indicate that EMST has the potential to manipulate the microstructure of high‐strength steel and improve its mechanical properties.
- 29 October 2025
- Published by Wiley in Advanced Engineering Materials
- Vol. 27 (23)
Improving Mechanical Properties of M50 Steel via Martensite Transformation and Carbide Precipitation Under Electromagnetic Shock Treatment
As a new type of material post‐treatment method, electromagnetic shock treatment (EMST) shows the advantages of high‐energy utilization rate, short time consumption, and the ability to perform local treatment. This treatment method can provide new technologies and theoretical guidance for the high‐performance manufacturing of bearings and can be used to regulate the microstructure and mechanical properties of bearings. In this article, the tempered M50 steel (8Cr4Mo4V) is selected as the research object to explore the influence mechanism of EMST on its microstructure (grain size, grain orientation, texture, dislocation density) and mechanical properties (hardness, compressive strength). Microstructure observation results show that the original austenite grain boundaries became blurred after EMST. The acicular martensite is formed, accompanied by the precipitation of lath carbides and short‐rod carbides. The average KAM values decrease from 0.95° to 0.67° after EMST. The results of mechanical tests show that the hardness of the sample after EMST increases from 316.7 to 333.8 HV, and the compressive yield strength increases from 1611 to 1899 MPa. These findings indicate that EMST has the potential to manipulate the microstructure of high‐strength steel and improve its mechanical properties.