Amera Ghareeb Baker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Amera Ghareeb Baker has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Faten Adel Ismael Chaqmaqchee
Department of Physics, Faculty of Science and Health, Koya University, Koya 44023, Kurdistan Region – F.R. Iraq
3 shared publications - Najeba Farhad Salih
Koya University
3 shared publications - Hawbash Hamadamin Karim
Koya University
2 shared publications Koya University
2 shared publications- Ali S. Dawood
Department of Environmental Engineering, School of Civil Engineering, Universiti Sains Malaysia, Engineering campus, Penang, Malaysia
1 shared publication - Fatehah Mohd Omar
School of Civil Engineering, Engineering Campus, Universiti Sains Malaysia, Nibong Tebal 14300, Penang, Malaysia
1 shared publication
Latest Publications
- 23 December 2025
- Published by Elsevier in Physica B: Condensed Matter
- Vol. 725
Impact of thermal neutron radiation doses on the density of states in the Ge12Te80Sn8 alloy
- 23 December 2025
- Published by Elsevier in Physica B: Condensed Matter
- Vol. 725
Impact of thermal neutron radiation doses on the density of states in the Ge12Te80Sn8 alloy
- Open Access
- 1 July 2025
- Published by Koya University in ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY
- Vol. 13 (2) , 142-151
Performance Evaluation of Membrane Bioreactor Operational Design in Sewage Treatment Plant using GPS-X Software
This study evaluates the operational performance of a full-scale membrane bioreactor wastewater treatment plant located in Kuala Lumpur using GPS-X 8.0 simulation software. Key performance indicators–including mixed liquor suspended solids (MLSS), transmembrane pressure (TMP), dissolved oxygen, and effluent total suspended solids (TSS)were monitored over 30 days. The simulations were conducted using the advanced mode and calibrated with actual plant data. Results show that although the plant complies with Malaysian effluent discharge standards, it operates well below its design capacity, with MLSS levels significantly lower than recommended. This operational underload contributes to increased energy consumption and reduced treatment efficiency, particularly in terms of TSS and chemical oxygen demand removal.
- 1 July 2025
- Published by Koya University in ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY
- Vol. 13 (2) , 142-151
Open AccessPerformance Evaluation of Membrane Bioreactor Operational Design in Sewage Treatment Plant using GPS-X Software
This study evaluates the operational performance of a full-scale membrane bioreactor wastewater treatment plant located in Kuala Lumpur using GPS-X 8.0 simulation software. Key performance indicators–including mixed liquor suspended solids (MLSS), transmembrane pressure (TMP), dissolved oxygen, and effluent total suspended solids (TSS)were monitored over 30 days. The simulations were conducted using the advanced mode and calibrated with actual plant data. Results show that although the plant complies with Malaysian effluent discharge standards, it operates well below its design capacity, with MLSS levels significantly lower than recommended. This operational underload contributes to increased energy consumption and reduced treatment efficiency, particularly in terms of TSS and chemical oxygen demand removal.
- Open Access
- 30 May 2019
- Published by Koya University in ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY
- Vol. 7 (1) , 47-52
The Study of Optical Energy Gap, Refractive Index, and Dielectric Constant of Pure and Doped Polyaniline with HCl and H2SO4 Acids
Polyaniline (PANI) salt in its pure and doped forms find extensive applications in making devices such as polymer light emitting diodes, photovoltaic, sensors, batteries, and super capacitors. PANI salt has been synthesized successfully through chemically oxidative polymerization of aniline in the presence of hydrochloric acid (HCl) and sulfuric acid (H2 SO4 ) using ammonium peroxydisulfate as an oxidizing agent. The absorption spectra of pure PANI salt and its doped state, in HCl and H2 SO4 media, have been studied in the wavelength range from 200 to 1100 nm using ultraviolet and visible near infrared spectrophotometer. Tauc’s formula, Lambert-Beer’s relation, and Fresnel’s formula were employed in the MATLAB program to calculate the optical energy gap, refractive index, and dielectric constant. Results showed that doping with HCl and H2 SO4 acidic mediums caused a reduction in the direct energy gap of the pure PANI from 2.69eV to 2.42 eV and 2.54 eV, respectively. The reduction in optical energy gap is associated with the increase in refractive index. The refractive index (2.92) has a higher value of PANI doped with HCl. Higher refractive index values are for better-structured films.
- 30 May 2019
- Published by Koya University in ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY
- Vol. 7 (1) , 47-52
Open AccessThe Study of Optical Energy Gap, Refractive Index, and Dielectric Constant of Pure and Doped Polyaniline with HCl and H2SO4 Acids
Polyaniline (PANI) salt in its pure and doped forms find extensive applications in making devices such as polymer light emitting diodes, photovoltaic, sensors, batteries, and super capacitors. PANI salt has been synthesized successfully through chemically oxidative polymerization of aniline in the presence of hydrochloric acid (HCl) and sulfuric acid (H2 SO4 ) using ammonium peroxydisulfate as an oxidizing agent. The absorption spectra of pure PANI salt and its doped state, in HCl and H2 SO4 media, have been studied in the wavelength range from 200 to 1100 nm using ultraviolet and visible near infrared spectrophotometer. Tauc’s formula, Lambert-Beer’s relation, and Fresnel’s formula were employed in the MATLAB program to calculate the optical energy gap, refractive index, and dielectric constant. Results showed that doping with HCl and H2 SO4 acidic mediums caused a reduction in the direct energy gap of the pure PANI from 2.69eV to 2.42 eV and 2.54 eV, respectively. The reduction in optical energy gap is associated with the increase in refractive index. The refractive index (2.92) has a higher value of PANI doped with HCl. Higher refractive index values are for better-structured films.
- Open Access
- 13 September 2018
- Published by Koya University in ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY
- Vol. 6 (2) , 1-6
Topical Powder Mix of Chalcanthite, Alum, and Clove as an Effective Feet Odor Treatment
Topical Powder Mix of Chalcanthite, Alum, and Clove as an Effective Feet Odor Treatment
- 13 September 2018
- Published by Koya University in ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY
- Vol. 6 (2) , 1-6
Open AccessTopical Powder Mix of Chalcanthite, Alum, and Clove as an Effective Feet Odor Treatment
Topical Powder Mix of Chalcanthite, Alum, and Clove as an Effective Feet Odor Treatment
- 1 August 2018
- Published by Koya University
- p. 161-164
Measurement of Radon Concentration in Urine using PM-355 Detector
- 1 August 2018
- Published by Koya University
- p. 161-164
Measurement of Radon Concentration in Urine using PM-355 Detector
- Open Access
- 24 April 2017
- Published by Science Publishing Group in American Journal of Materials Synthesis and Processing
- Vol. 2 (2) , 24-27
Comparison of Various Plastics Wastes Using X-ray Fluorescence
Plastics production is increased recently due to their various applications such as construction, electronic, packaging and others. The rising in plastics demand lead to developed of recycling and energy recovery method to control plastic wastes. Recycling process is needs to be arranged according to resins, colors and transparency of all plastics. Energy dispersive X-ray fluorescence (EDXRF) was developed for the determination of the chemical composition in different plastics materials (with resin identification code) of PETE (1) or PET (01), HDPE (2) or PE-HD (02), V (3) or PVC (03), LDPE (4) or PE-LD, PP (5) or PP (06), PS (6) or PS (06) and Others (7) or O (07). XRF was measured elements such as Si, S, Cl, Fr, Ca, Ti, V, Fe, Cu, Zn, As, Kr, Zr, Nb, Mo and Nb in both k α and k β lines, where PP with high percentage in both PET and PVC plastics, which is highly hazardous. In addition, chemical compositions in percentages were detected for various plastics materials.
- 24 April 2017
- Published by Science Publishing Group in American Journal of Materials Synthesis and Processing
- Vol. 2 (2) , 24-27
Open AccessComparison of Various Plastics Wastes Using X-ray Fluorescence
Plastics production is increased recently due to their various applications such as construction, electronic, packaging and others. The rising in plastics demand lead to developed of recycling and energy recovery method to control plastic wastes. Recycling process is needs to be arranged according to resins, colors and transparency of all plastics. Energy dispersive X-ray fluorescence (EDXRF) was developed for the determination of the chemical composition in different plastics materials (with resin identification code) of PETE (1) or PET (01), HDPE (2) or PE-HD (02), V (3) or PVC (03), LDPE (4) or PE-LD, PP (5) or PP (06), PS (6) or PS (06) and Others (7) or O (07). XRF was measured elements such as Si, S, Cl, Fr, Ca, Ti, V, Fe, Cu, Zn, As, Kr, Zr, Nb, Mo and Nb in both k α and k β lines, where PP with high percentage in both PET and PVC plastics, which is highly hazardous. In addition, chemical compositions in percentages were detected for various plastics materials.
- Open Access
- 14 March 2017
- Published by MDPI AG in Preprints.org
Comparison of Various Plastics Wastes Using X-Ray Fluorescence
Plastics production is increased recently due to their various applications such as construction, electronic, packaging and others. The rising in plastics demand lead to developed of recycling and energy recovery method to control plastic wastes. Recycling process is needs to be arranged according to resins, colors and transparency of all plastics. Energy dispersive X-ray fluorescence (EDXRF) was developed for the determination of the chemical composition in different plastics materials (with resin identification code) of PETE (1) or PET (01), HDPE (2) or PE-HD (02), V (3) or PVC (03), LDPE (4) or PE-LD, PP (5) or PP (06), PS (6) or PS (06) and Others (7) or O (07). XRF was measured elements such as Si, S, Cl, Fr, Ca, Ti, V, Fe, Cu, Zn, As, Kr, Zr, Nb, Mo and Nb in both kα and kβ lines. In addition, chemical compositions in percentages were detected for various plastics materials.
- 14 March 2017
- Published by MDPI AG in Preprints.org
Open AccessComparison of Various Plastics Wastes Using X-Ray Fluorescence
Plastics production is increased recently due to their various applications such as construction, electronic, packaging and others. The rising in plastics demand lead to developed of recycling and energy recovery method to control plastic wastes. Recycling process is needs to be arranged according to resins, colors and transparency of all plastics. Energy dispersive X-ray fluorescence (EDXRF) was developed for the determination of the chemical composition in different plastics materials (with resin identification code) of PETE (1) or PET (01), HDPE (2) or PE-HD (02), V (3) or PVC (03), LDPE (4) or PE-LD, PP (5) or PP (06), PS (6) or PS (06) and Others (7) or O (07). XRF was measured elements such as Si, S, Cl, Fr, Ca, Ti, V, Fe, Cu, Zn, As, Kr, Zr, Nb, Mo and Nb in both kα and kβ lines. In addition, chemical compositions in percentages were detected for various plastics materials.
- Open Access
- 11 January 2016
- Published by Lifescience Global in Journal of Research Updates in Polymer Science
- Vol. 4 (4) , 188-190
Study and Characterization of Polyaniline at Various Doping of LiCl wt.% Using Electrical Measurements and XRF Analysis
Polyaniline PANI samples were synthesized via chemical polymerization method. The mechanism of charge transport in these composites has been studies by measuring the DC conductivity at various lithium chloride LiCl wt.%. It shows that their activation energy decreases with increasing LiCl concentration and thus, the conductivity increases at 15 %wt. In addition, X-ray Fluorescence XRF was used to analysis the elements of PANI regarding to LiCl concentration. The elements positively detected by the XRF are Cl, Kr, SO3, Al2O3, SiO2, and ZrO2. The XRF data show a relative systematic error typically independent of the concentration. The accuracy is determined by comparing the XRF data with various LiCl wt.%.
- 11 January 2016
- Published by Lifescience Global in Journal of Research Updates in Polymer Science
- Vol. 4 (4) , 188-190
Open AccessStudy and Characterization of Polyaniline at Various Doping of LiCl wt.% Using Electrical Measurements and XRF Analysis
Polyaniline PANI samples were synthesized via chemical polymerization method. The mechanism of charge transport in these composites has been studies by measuring the DC conductivity at various lithium chloride LiCl wt.%. It shows that their activation energy decreases with increasing LiCl concentration and thus, the conductivity increases at 15 %wt. In addition, X-ray Fluorescence XRF was used to analysis the elements of PANI regarding to LiCl concentration. The elements positively detected by the XRF are Cl, Kr, SO3, Al2O3, SiO2, and ZrO2. The XRF data show a relative systematic error typically independent of the concentration. The accuracy is determined by comparing the XRF data with various LiCl wt.%.
- 31 October 2012
- Published by Insan Akademika Publications in International Journal of Basic and Applied Science
- Vol. 1 (2) , 338-348
A.C Electrical Conductivity for Polyaniline Prepered in Different Acidic Medium
- Polyaniline was prepared in different acidic medium at room temperatuer. The out put of polymerization was characterization by FT-IR. The A.C el...
- 31 October 2012
- Published by Insan Akademika Publications in International Journal of Basic and Applied Science
- Vol. 1 (2) , 338-348
A.C Electrical Conductivity for Polyaniline Prepered in Different Acidic Medium
- Polyaniline was prepared in different acidic medium at room temperatuer. The out put of polymerization was characterization by FT-IR. The A.C el...