Bhaskar Manna
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bhaskar Manna has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- Chellappan Retna Raj
Indian Institute of Technology Kharagpur
2 shared publications
Latest Publications
- Open Access
- 23 August 2019
- Published by Springer Nature in Analytical Sciences
- Vol. 36 (1) , 121-125
Reduced Graphene Oxide-based Covalent Hybrid Film Electrode Self-assembled with Gold Nanoparticles for the Enzyme-Free Amperometric Sensing of Serum Uric Acid
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 23 August 2019
- Published by Springer Nature in Analytical Sciences
- Vol. 36 (1) , 121-125
Open AccessReduced Graphene Oxide-based Covalent Hybrid Film Electrode Self-assembled with Gold Nanoparticles for the Enzyme-Free Amperometric Sensing of Serum Uric Acid
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 29 May 2018
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 143 (14) , 3451-3457
Rational functionalization of reduced graphene oxide with an imidazole group for the electrochemical sensing of bisphenol A – an endocrine disruptor
Reduced graphene oxide has been rationally functionalized with histamine for the highly sensitive and selective electrochemical determination of bisphenol A (BPA). Histamine is covalently attached to graphene oxide by amide coupling and the oxygen functionalities of graphene oxide are partially reduced electrochemically. The facilitated electrochemical oxidation of BPA was achieved in neutral pH with functionalized reduced graphene oxide. The pH of the reaction controls the oxidation of BPA. Electrochemical oxidation is not favourable at pH less than the pKa of histamine due to the protonation of the imidazole nitrogen. The electrode is highly sensitive (1727.29 ± 12.48 nA μM−1 cm−2) towards BPA and shows a linear response up to 30 μM of BPA. It could detect as low as 0.03 nM of BPA (S/N = 5). The other coexisting analytes do not interfere with the voltammetric measurement of BPA.
- 29 May 2018
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 143 (14) , 3451-3457
Rational functionalization of reduced graphene oxide with an imidazole group for the electrochemical sensing of bisphenol A – an endocrine disruptor
Reduced graphene oxide has been rationally functionalized with histamine for the highly sensitive and selective electrochemical determination of bisphenol A (BPA). Histamine is covalently attached to graphene oxide by amide coupling and the oxygen functionalities of graphene oxide are partially reduced electrochemically. The facilitated electrochemical oxidation of BPA was achieved in neutral pH with functionalized reduced graphene oxide. The pH of the reaction controls the oxidation of BPA. Electrochemical oxidation is not favourable at pH less than the pKa of histamine due to the protonation of the imidazole nitrogen. The electrode is highly sensitive (1727.29 ± 12.48 nA μM−1 cm−2) towards BPA and shows a linear response up to 30 μM of BPA. It could detect as low as 0.03 nM of BPA (S/N = 5). The other coexisting analytes do not interfere with the voltammetric measurement of BPA.
- 29 March 2018
- Published by American Chemical Society (ACS) in ACS Sustainable Chemistry & Engineering
- Vol. 6 (5) , 6175-6182
Nanostructured Sulfur-Doped Porous Reduced Graphene Oxide for the Ultrasensitive Electrochemical Detection and Efficient Removal of Hg(II)
- 29 March 2018
- Published by American Chemical Society (ACS) in ACS Sustainable Chemistry & Engineering
- Vol. 6 (5) , 6175-6182
Nanostructured Sulfur-Doped Porous Reduced Graphene Oxide for the Ultrasensitive Electrochemical Detection and Efficient Removal of Hg(II)
- 1 June 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 4 (26) , 4585-4593
Covalent functionalization and electrochemical tuning of reduced graphene oxide for the bioelectrocatalytic sensing of serum lactate
Lactate is a byproduct of glycolysis and serum lactate can be used as a non-invasive biomarker in risk-stratifying patients with several life-threatening diseases. Herein, we describe the bioelectrocatalytic sensing of lactate using a covalently functionalized reduced graphene oxide (rGO)-based material. The development of a lactate biosensor involves the covalent functionalization of rGO with the p-nitrophenyl moiety, electrochemical generation of a surface-confined redox mediator and immobilization of L-lactate dehydrogenase (LDH). The covalently functionalized rGO was characterized by XRD, XPS, FTIR, Raman, resistivity and electrochemical measurements. The covalent attachment of the nitrophenyl moiety on the basal plane of the carbon network significantly influences the capacitive properties of rGO. The chemically functionalized rGO was electrochemically tuned to generate a redox mediator (rGO-PhNHOH). An electrochemically generated redox couple (PhNHOH/PhNO) exhibits reversible voltammetric response at ∼−0.06 V with a surface coverage of (7.19 ± 0.26) × 10−9 mol cm−2. The redox couple efficiently mediates the oxidation of NADH at 0.04 V, which is ∼600 mV less positive potential than the unmodified electrode. The electrode is highly sensitive towards NADH and it could detect as low as 0.4 μM NADH at the potential of 40 mV at neutral pH without any interference from co-existing bioanalytes. A lactate biosensor was developed using the rGO-PhNHOH functional material and lactate dehydrogenase. The surface-confined redox mediator could successfully detect the enzymatically generated NADH at 40 mV. The biosensor is highly sensitive (10.57 ± 0.38 nA μM−1 cm−2) and shows linear response up to 90 μM of lactate. It could detect lactate as low as 2.5 μM without any interference from other analytes. This biosensor has been successfully used to quantify human serum lactate and the results are in excellent agreement with those obtained by the clinical method.
- 1 June 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 4 (26) , 4585-4593
Covalent functionalization and electrochemical tuning of reduced graphene oxide for the bioelectrocatalytic sensing of serum lactate
Lactate is a byproduct of glycolysis and serum lactate can be used as a non-invasive biomarker in risk-stratifying patients with several life-threatening diseases. Herein, we describe the bioelectrocatalytic sensing of lactate using a covalently functionalized reduced graphene oxide (rGO)-based material. The development of a lactate biosensor involves the covalent functionalization of rGO with the p-nitrophenyl moiety, electrochemical generation of a surface-confined redox mediator and immobilization of L-lactate dehydrogenase (LDH). The covalently functionalized rGO was characterized by XRD, XPS, FTIR, Raman, resistivity and electrochemical measurements. The covalent attachment of the nitrophenyl moiety on the basal plane of the carbon network significantly influences the capacitive properties of rGO. The chemically functionalized rGO was electrochemically tuned to generate a redox mediator (rGO-PhNHOH). An electrochemically generated redox couple (PhNHOH/PhNO) exhibits reversible voltammetric response at ∼−0.06 V with a surface coverage of (7.19 ± 0.26) × 10−9 mol cm−2. The redox couple efficiently mediates the oxidation of NADH at 0.04 V, which is ∼600 mV less positive potential than the unmodified electrode. The electrode is highly sensitive towards NADH and it could detect as low as 0.4 μM NADH at the potential of 40 mV at neutral pH without any interference from co-existing bioanalytes. A lactate biosensor was developed using the rGO-PhNHOH functional material and lactate dehydrogenase. The surface-confined redox mediator could successfully detect the enzymatically generated NADH at 40 mV. The biosensor is highly sensitive (10.57 ± 0.38 nA μM−1 cm−2) and shows linear response up to 90 μM of lactate. It could detect lactate as low as 2.5 μM without any interference from other analytes. This biosensor has been successfully used to quantify human serum lactate and the results are in excellent agreement with those obtained by the clinical method.