Ben Hughes
Research Subjects
Research Interests
Ben Hughes has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- John Kaiser Calautit
Department of Architecture and Built Environment, University of Nottingham, Nottingham NG7 2RD, UK
2 shared publications - Chris Grabowski
Science Applications International Corporation, 2109 Air Park Rd SE, Albuquerque, NM 87106 USA
1 shared publication - Daniel Nakhaee-Zadeh Gutierrez
Adaptyv Biosystems
1 shared publication - Dimitris Theodossopoulos
ESALA, Edinburgh College of Art, University of Edinburgh, Edinburgh, UK
1 shared publication - Dominic O'COnnor
Department of Mechanical Engineering, University of Sheffield, Sheffield S10 2TN, UK
1 shared publication Esmail A. ElBialy
1 shared publication
Latest Publications
- Open Access
- 16 January 2019
- Published by World Energy and Environment Technology Ltd - WEENTECH in WEENTECH Proceedings in Energy
- p. 26-36
Development of Stirling Pump mechanism for Irrigation in remote rural farms
Inadequate supply of safe water, the requirement of food exports, Low GDP creates a scenario where 26% of the population in the Sub-Saharan Africa suffer from food insecurity. Cultivation of food locally is necessary to drive the cost of food down. This can be done using the abundant groundwater source in the region, however, the energy cost of harvesting the water supply is very high and hence not presently utilised. While solar PV technology is readily available, PV solutions are much too expensive for small scale rural farmers. This research aims at developing a solar thermal powered Stirling pump that can be produced locally, using local resources to reduce irrigation costs and provide income, food and energy security in the region, by promoting independent farming through small-scale farms. In order to develop the Stirling pump, a Low Temperature Differential (LTD) Stirling engine has been modelled in 3D, simulated and investigated with the help of Computational Fluid Dynamics with ANSYS 16.1 software. The Analysis is aimed at obtaining a true representation of the pressure, temperature and compression ratio that dictate the functioning of a Gamma type Stirling engine. This model developed can then be modified and improved upon to further boost the performance of the Stirling Engine to be integrated with a water pumping system to extract ground water for irrigation purposes.
- 16 January 2019
- Published by World Energy and Environment Technology Ltd - WEENTECH in WEENTECH Proceedings in Energy
- p. 26-36
Open AccessDevelopment of Stirling Pump mechanism for Irrigation in remote rural farms
Inadequate supply of safe water, the requirement of food exports, Low GDP creates a scenario where 26% of the population in the Sub-Saharan Africa suffer from food insecurity. Cultivation of food locally is necessary to drive the cost of food down. This can be done using the abundant groundwater source in the region, however, the energy cost of harvesting the water supply is very high and hence not presently utilised. While solar PV technology is readily available, PV solutions are much too expensive for small scale rural farmers. This research aims at developing a solar thermal powered Stirling pump that can be produced locally, using local resources to reduce irrigation costs and provide income, food and energy security in the region, by promoting independent farming through small-scale farms. In order to develop the Stirling pump, a Low Temperature Differential (LTD) Stirling engine has been modelled in 3D, simulated and investigated with the help of Computational Fluid Dynamics with ANSYS 16.1 software. The Analysis is aimed at obtaining a true representation of the pressure, temperature and compression ratio that dictate the functioning of a Gamma type Stirling engine. This model developed can then be modified and improved upon to further boost the performance of the Stirling Engine to be integrated with a water pumping system to extract ground water for irrigation purposes.
- Open Access
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 322-327
Solid State Laser Triggering System for the HERMES-III Accelerator
The Hermes III accelerator is a 20-MV linear induction accelerator that has been in operation at Sandia National Laboratories since the late 1980’s. Energy is initially stored in the accelerator in ten Marx banks that are discharged into twenty intermediate store capacitors. These intermediate store capacitors are then switched with SF 6 -insulated high voltage Rimfire switches into eighty parallel pulse forming lines that further condition the pulse before finally delivering it to the twenty induction cavities arrayed along the axis of the machine. Currently, a single 0.9-J KrF laser operating at 248 nm, the output of which is divided into twenty separate beamlets, is being used to trigger the Rimfire switches. However, as part of a modernization plan for the accelerator, the gas laser system is being replaced with a new solid-state laser triggering system. The new system is comprised of 10 flash-lamp pumped, Q-switched Nd:YAG lasers (Tempest 300), each having an energy output of 35~40 mJ at a wavelength of 266 nm. Each laser will be responsible for triggering two Rimfire switches. Overall reliability for the accelerator’s operation with these new lasers is expected to increase, and by varying the times at which the individual lasers fire it becomes possible to tailor the shape of the output pulse. The optical layout and other details of this solid-state laser triggering system are presented, along with initial operational data from the HERMES III accelerator using this system.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 322-327
Open AccessSolid State Laser Triggering System for the HERMES-III Accelerator
The Hermes III accelerator is a 20-MV linear induction accelerator that has been in operation at Sandia National Laboratories since the late 1980’s. Energy is initially stored in the accelerator in ten Marx banks that are discharged into twenty intermediate store capacitors. These intermediate store capacitors are then switched with SF 6 -insulated high voltage Rimfire switches into eighty parallel pulse forming lines that further condition the pulse before finally delivering it to the twenty induction cavities arrayed along the axis of the machine. Currently, a single 0.9-J KrF laser operating at 248 nm, the output of which is divided into twenty separate beamlets, is being used to trigger the Rimfire switches. However, as part of a modernization plan for the accelerator, the gas laser system is being replaced with a new solid-state laser triggering system. The new system is comprised of 10 flash-lamp pumped, Q-switched Nd:YAG lasers (Tempest 300), each having an energy output of 35~40 mJ at a wavelength of 266 nm. Each laser will be responsible for triggering two Rimfire switches. Overall reliability for the accelerator’s operation with these new lasers is expected to increase, and by varying the times at which the individual lasers fire it becomes possible to tailor the shape of the output pulse. The optical layout and other details of this solid-state laser triggering system are presented, along with initial operational data from the HERMES III accelerator using this system.
- 1 March 2017
- Published by Elsevier in Energy and Buildings
- Vol. 139, 702-718
Thermal performance of stadium’s Field of Play in hot climates
- 1 March 2017
- Published by Elsevier in Energy and Buildings
- Vol. 139, 702-718
Thermal performance of stadium’s Field of Play in hot climates
- Open Access
- 26 October 2016
- Published by Taylor & Francis in Architectural Science Review
- Vol. 60 (1) , 49-61
A study of the impact of individual thermal control on user comfort in the workplace: Norwegian cellular vs. British open plan offices
In modern offices, user control is being replaced by centrally operated thermal systems, and in Scandinavia, personal offices by open plan layouts. This study examined the impact of user control on thermal comfort and satisfaction. It compared a workplace, which was designed entirely based on individual control over the thermal environment, to an environment that limited thermal control was provided as a secondary option for fine-tuning: Norwegian cellular and British open plan offices. The Norwegian approach provided each user with control over a window, door, blinds, heating and cooling as the main thermal control system. In contrast, the British practice provided a uniform thermal environment with limited openable windows and blinds to refine the thermal environment for occupants seated around the perimeter of the building. Field studies of thermal comfort were applied to measure users’ perception of thermal environment, empirical building performance and thermal control. The results showed a 30% higher satisfaction and 18% higher comfort level in the Norwegian offices compared to the British practices. However, the energy consumption of the Norwegian case studies was much higher compared to the British ones. A balance is required between energy efficiency and user thermal comfort in the workplace.
- 26 October 2016
- Published by Taylor & Francis in Architectural Science Review
- Vol. 60 (1) , 49-61
Open AccessA study of the impact of individual thermal control on user comfort in the workplace: Norwegian cellular vs. British open plan offices
In modern offices, user control is being replaced by centrally operated thermal systems, and in Scandinavia, personal offices by open plan layouts. This study examined the impact of user control on thermal comfort and satisfaction. It compared a workplace, which was designed entirely based on individual control over the thermal environment, to an environment that limited thermal control was provided as a secondary option for fine-tuning: Norwegian cellular and British open plan offices. The Norwegian approach provided each user with control over a window, door, blinds, heating and cooling as the main thermal control system. In contrast, the British practice provided a uniform thermal environment with limited openable windows and blinds to refine the thermal environment for occupants seated around the perimeter of the building. Field studies of thermal comfort were applied to measure users’ perception of thermal environment, empirical building performance and thermal control. The results showed a 30% higher satisfaction and 18% higher comfort level in the Norwegian offices compared to the British practices. However, the energy consumption of the Norwegian case studies was much higher compared to the British ones. A balance is required between energy efficiency and user thermal comfort in the workplace.