Naser Khodabakhshi-Javinani
Naser Khodabakhshi-Javinani has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Hamed Nafisi
Department of Electrical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
2 shared publications Ali Bayandour
Amirkabir University of Technology (Tehran Polytechnic),Department of Electrical Engineering,Tehran,Iran
1 shared publication- Amir Aghazadeh
School of Electronic and Electrical Engineering, University of Leeds, Leeds, U.K.
1 shared publication - Hamed Jabbari Namvar
Amirkabir University of Technology Department of Electrical Engineering, 473905 Tehran, Tehran Iran (the Islamic Republic of)
1 shared publication - Hossein Askarian Abyaneh
Amirkabir University of Technology
1 shared publication - Mehdi Bostan Shirin
Department of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
1 shared publication
Latest Publications
- 5 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Impact Of Distributed Generation on Coordination of Overcurrent Relays by Benders Decomposition Algorithm
Power System Protection plays a notable role in power systems. Directional Over-Current Relays (DOCRs) are usually used in the distribution system as main and backup protection in the transmission system. Although the backup concept guarantees protection, optimum coordination is still challenging in ring and complex grids. This study aims to achieve overcurrent relay coordination by the Benders decomposition algorithm in a power grid. This analytical approach is proposed to find the time setting of DOCRs in a nine-bus transmission system, in two modes with distributed generation (DG) and without DG.
- 5 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Impact Of Distributed Generation on Coordination of Overcurrent Relays by Benders Decomposition Algorithm
Power System Protection plays a notable role in power systems. Directional Over-Current Relays (DOCRs) are usually used in the distribution system as main and backup protection in the transmission system. Although the backup concept guarantees protection, optimum coordination is still challenging in ring and complex grids. This study aims to achieve overcurrent relay coordination by the Benders decomposition algorithm in a power grid. This analytical approach is proposed to find the time setting of DOCRs in a nine-bus transmission system, in two modes with distributed generation (DG) and without DG.
- Retracted
- 15 June 2023
- Published by Springer Nature in Iranian Journal of Science and Technology, Transactions of Mechanical Engineering
- Vol. 48 (4) , 1775
RETRACTED ARTICLE: Determining Equations Governing Multibody Dynamic Systems Through Joint Kinematics and Kinematic Chain Effects in Closed-Form Mechanisms
- 15 June 2023
- Published by Springer Nature in Iranian Journal of Science and Technology, Transactions of Mechanical Engineering
- Vol. 48 (4) , 1775
RetractedRETRACTED ARTICLE: Determining Equations Governing Multibody Dynamic Systems Through Joint Kinematics and Kinematic Chain Effects in Closed-Form Mechanisms
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 76, 39-46
Communication Delay Time Investigation of Over Current Adaptive Relays in a IEC 61850 based Micro-grid in the Presence of Error
Calculating the time the message sent from the MCPU to the Integrated Radio Consulting Services (MCPU) relay needs to be calculated from the system topology change because of the need or desire for the services provided. The MCPU is best served by using the MCPU to give you the best option that has changed potential locations and is updating.
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 76, 39-46
Communication Delay Time Investigation of Over Current Adaptive Relays in a IEC 61850 based Micro-grid in the Presence of Error
Calculating the time the message sent from the MCPU to the Integrated Radio Consulting Services (MCPU) relay needs to be calculated from the system topology change because of the need or desire for the services provided. The MCPU is best served by using the MCPU to give you the best option that has changed potential locations and is updating.
- 15 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (10) , 7581-7592
Introduction and Advantage of Space Opposite Vectors Modulation Utilized in Dual Two-Level Inverters With Isolated DC Sources
In this paper, Space Opposite Vectors Modulation (SOVM) is proposed to decrease Common-Mode Voltage (CMV), and also improve inverter switching losses compared to PWM7 for Dual Two-Level Inverters (DTLI). Employing the control simplicity of DTLI to achieve multi-level winding voltages, the two conventional two-level inverters of DTLI are independently controlled; consequently, the capability of adjusting Phase Difference between the Carriers (PDC) of two inverters is established. To mathematically evaluate and compare the performance of DTLI driven by SOVM and PWM7, CMV and losses for different PWMs are formulated. Moreover, contour, 3-D and 2-D analyses are conducted to investigate the effects of PDC and Modulation Index (MI) on CMV, voltage Total Harmonic Distortion (THD), voltage Weighted Total Harmonic Distortion (WTHD) and switching losses. All theoretical bases, simulation results from MATLAB/Simulink and experimental results conducted by a DTLI prototype validate the superiority of SOVM over PWM7.
- 15 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (10) , 7581-7592
Introduction and Advantage of Space Opposite Vectors Modulation Utilized in Dual Two-Level Inverters With Isolated DC Sources
In this paper, Space Opposite Vectors Modulation (SOVM) is proposed to decrease Common-Mode Voltage (CMV), and also improve inverter switching losses compared to PWM7 for Dual Two-Level Inverters (DTLI). Employing the control simplicity of DTLI to achieve multi-level winding voltages, the two conventional two-level inverters of DTLI are independently controlled; consequently, the capability of adjusting Phase Difference between the Carriers (PDC) of two inverters is established. To mathematically evaluate and compare the performance of DTLI driven by SOVM and PWM7, CMV and losses for different PWMs are formulated. Moreover, contour, 3-D and 2-D analyses are conducted to investigate the effects of PDC and Modulation Index (MI) on CMV, voltage Total Harmonic Distortion (THD), voltage Weighted Total Harmonic Distortion (WTHD) and switching losses. All theoretical bases, simulation results from MATLAB/Simulink and experimental results conducted by a DTLI prototype validate the superiority of SOVM over PWM7.