Weixiu Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Weixiu Shi has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Lisheng Pan
State Key Laboratory of High Temperature Gas Dynamics, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China
6 shared publications - Shuang Quan
School of Environmental and Energy Engineering, Beijing University of Civil Engineering and Architecture, Beijing 100044, China
2 shared publications - Bai Mu
School of Environment and Energy Engineering, Beijing University of Civil Engineering and Architecture, Beijing 100044, China
1 shared publication - Haiyu Chang
School of Environment and Energy Engineering, Beijing University of Civil Engineering and Architecture, Beijing 100044, China
1 shared publication - Haofan Mu
School of Environment and Energy Engineering, Beijing University of Civil Engineering and Architecture, Beijing 100044, China
1 shared publication - Hongdi Chen
School of Environment and Energy Engineering, Beijing University of Civil Engineering and Architecture, Beijing 100044, China
1 shared publication
Latest Publications
- Open Access
Assessment of Carbon Emission Reductions from a Rural Rooftop PV System Based on SAM
To investigate the effects of model selection, time-varying parameters and climatic differences on the carbon emission reduction performance of rural rooftop photovoltaic (PV) systems, this study selected a typical rural residential rooftop PV system in Beijing as the research object. Hourly simulations using the System Advisor Model (SAM) and an operational-period baseline method were employed to optimize the PV array parameters and conduct a multi-factor analysis of carbon emission reductions. The results show that the first-year electricity generation was 15,902 kWh, corresponding to an annual carbon emission reduction of 12.60 tCO2. The carbon emission reduction estimates obtained using the three irradiance models differed, with a maximum deviation of 0.51 tCO2. When both PV module degradation and changes in the grid emission factor were considered, the cumulative carbon emission reduction decreased by 68.37 tCO2 relative to the ideal scenario. Moreover, the faster the grid transition speed, the lower the cumulative carbon emission reduction over the system’s operational period. In addition, extending the analysis from a single region to multiple regions revealed that the annual carbon emission reductions in representative rural residential rooftop PV systems in Beijing and Wuhan differed by 2.94 tCO2, with differences also observed in their seasonal variation patterns. The assessment of rural rooftop PV systems should comprehensively consider irradiance model selection, module power degradation, grid transition pathways, regional climatic conditions and economic feasibility.
Open AccessAssessment of Carbon Emission Reductions from a Rural Rooftop PV System Based on SAM
To investigate the effects of model selection, time-varying parameters and climatic differences on the carbon emission reduction performance of rural rooftop photovoltaic (PV) systems, this study selected a typical rural residential rooftop PV system in Beijing as the research object. Hourly simulations using the System Advisor Model (SAM) and an operational-period baseline method were employed to optimize the PV array parameters and conduct a multi-factor analysis of carbon emission reductions. The results show that the first-year electricity generation was 15,902 kWh, corresponding to an annual carbon emission reduction of 12.60 tCO2. The carbon emission reduction estimates obtained using the three irradiance models differed, with a maximum deviation of 0.51 tCO2. When both PV module degradation and changes in the grid emission factor were considered, the cumulative carbon emission reduction decreased by 68.37 tCO2 relative to the ideal scenario. Moreover, the faster the grid transition speed, the lower the cumulative carbon emission reduction over the system’s operational period. In addition, extending the analysis from a single region to multiple regions revealed that the annual carbon emission reductions in representative rural residential rooftop PV systems in Beijing and Wuhan differed by 2.94 tCO2, with differences also observed in their seasonal variation patterns. The assessment of rural rooftop PV systems should comprehensively consider irradiance model selection, module power degradation, grid transition pathways, regional climatic conditions and economic feasibility.
- Open Access
Dynamic Chaotic Evolution Law and Flow Characteristics of Pulsating Heat Pipes
Heating, ventilation and air conditioning (HVAC) accounts for an overwhelmingly large proportion of building energy consumption. Mass low-grade cold and heat energy dissipates during system operation, endowing pulsating heat pipes (PHPs) with promising application prospects in building energy systems. Combining experimental tests and the phase-space reconstruction method, this paper investigates the intrinsic correlation between the flow behavior of working fluids and chaotic characteristics under varied working fluids, heating powers and liquid filling ratios. The working fluid type dominates the oscillation characteristics of pulsating heat pipes. When distilled water serves as the working fluid, the attractor presents a scattered distribution. In contrast, the PHP charged with HFE-7100 achieves stable unidirectional circulation with high-frequency, small-amplitude pulsation, forming a densely distributed attractor. Increasing the flow velocity of the working fluid drives the attractor distribution to evolve from scattered to concentrated. Intermittent flow of the working fluid induces a multi-temperature-zone distribution on the tube wall, and the attractor takes on a multi-region spiral morphology. A low liquid filling ratio triggers working fluid dry-out, and the attractor trajectory maintains a continuous unidirectional upward trend; by comparison, the attractor shows a multi-region spiral distribution under high filling ratio conditions. Research on chaotic dynamic characteristic identification, evolutionary law analysis and stable domain regulation of pulsating heat pipes can lay a theoretical foundation for structural optimization and operating condition adjustment of high-performance pulsating heat pipe devices for building waste heat recovery.
Open AccessDynamic Chaotic Evolution Law and Flow Characteristics of Pulsating Heat Pipes
Heating, ventilation and air conditioning (HVAC) accounts for an overwhelmingly large proportion of building energy consumption. Mass low-grade cold and heat energy dissipates during system operation, endowing pulsating heat pipes (PHPs) with promising application prospects in building energy systems. Combining experimental tests and the phase-space reconstruction method, this paper investigates the intrinsic correlation between the flow behavior of working fluids and chaotic characteristics under varied working fluids, heating powers and liquid filling ratios. The working fluid type dominates the oscillation characteristics of pulsating heat pipes. When distilled water serves as the working fluid, the attractor presents a scattered distribution. In contrast, the PHP charged with HFE-7100 achieves stable unidirectional circulation with high-frequency, small-amplitude pulsation, forming a densely distributed attractor. Increasing the flow velocity of the working fluid drives the attractor distribution to evolve from scattered to concentrated. Intermittent flow of the working fluid induces a multi-temperature-zone distribution on the tube wall, and the attractor takes on a multi-region spiral morphology. A low liquid filling ratio triggers working fluid dry-out, and the attractor trajectory maintains a continuous unidirectional upward trend; by comparison, the attractor shows a multi-region spiral distribution under high filling ratio conditions. Research on chaotic dynamic characteristic identification, evolutionary law analysis and stable domain regulation of pulsating heat pipes can lay a theoretical foundation for structural optimization and operating condition adjustment of high-performance pulsating heat pipe devices for building waste heat recovery.
- Open Access
Research Progress on CO2 Transcritical Cycle Technology for Building Heating and Cooling Applications
This review focuses on the advancements of CO2 transcritical cycle technology in building indoor environmental regulation, particularly in combined heating and cooling applications. The paper highlights the energy efficiency and environmental benefits of CO2 as a natural refrigerant, which has zero ozone depletion potential (ODP) and very low global warming potential (GWP). It provides a comprehensive overview of recent optimization strategies, including distributed compression, the integration of ejectors and expanders, and the design improvements of key components such as gas coolers, compressors, and throttling valves. Through optimization strategies such as dual-system cycles, this technology can achieve a COP improvement of 15.3–46.96% in heating scenarios; meanwhile, with the help of distributed compression technology, its cooling capacity can be enhanced by up to 26.5%. The review also examines various operating conditions such as discharge pressure and subcooling, which significantly affect system performance. The paper concludes by identifying the current challenges in the application of CO2 systems, such as high initial costs and system stability under extreme conditions, and suggests future research directions to overcome these limitations and improve the practical application of CO2 transcritical cycles in the building industry. Overall, it is concluded that the development of expander-compressors holds great potential for achieving better performance and represents a promising direction for future advancements in this field.
Open AccessResearch Progress on CO2 Transcritical Cycle Technology for Building Heating and Cooling Applications
This review focuses on the advancements of CO2 transcritical cycle technology in building indoor environmental regulation, particularly in combined heating and cooling applications. The paper highlights the energy efficiency and environmental benefits of CO2 as a natural refrigerant, which has zero ozone depletion potential (ODP) and very low global warming potential (GWP). It provides a comprehensive overview of recent optimization strategies, including distributed compression, the integration of ejectors and expanders, and the design improvements of key components such as gas coolers, compressors, and throttling valves. Through optimization strategies such as dual-system cycles, this technology can achieve a COP improvement of 15.3–46.96% in heating scenarios; meanwhile, with the help of distributed compression technology, its cooling capacity can be enhanced by up to 26.5%. The review also examines various operating conditions such as discharge pressure and subcooling, which significantly affect system performance. The paper concludes by identifying the current challenges in the application of CO2 systems, such as high initial costs and system stability under extreme conditions, and suggests future research directions to overcome these limitations and improve the practical application of CO2 transcritical cycles in the building industry. Overall, it is concluded that the development of expander-compressors holds great potential for achieving better performance and represents a promising direction for future advancements in this field.
- Open Access
- 23 April 2025
- Published by MDPI AG in Colloids and Interfaces
- Vol. 9 (3) , 25
Influence and Correction of Refraction Phenomenon in Liquid Contact Angle Measurement in Capillary Tube
By using clear vapor–liquid interface line images of the liquid inside the capillary, the measurement coordinate points of the vapor–liquid interface line were measured. A new method for measuring liquid contact angle has been proposed, which was used to calculate the actual coordinate points and fit the actual vapor–liquid interface line of the liquid. Finally, an angle measurement tool is used to measure the angle of the actual vapor–liquid interface line and obtain the actual contact angle of the liquid. Effectively reducing the influence of refraction on the contact angle by correcting the errors caused by the refractive index of different materials, it can be used for the precise measurement of the static contact angle of liquids. By measuring the static contact angle of the upper and lower liquid surfaces of the liquid column, it was found that the presence of refraction caused a difference of [1.84°, 5.61°] between the actual and measured values of the static contact angle.
- 23 April 2025
- Published by MDPI AG in Colloids and Interfaces
- Vol. 9 (3) , 25
Open AccessInfluence and Correction of Refraction Phenomenon in Liquid Contact Angle Measurement in Capillary Tube
By using clear vapor–liquid interface line images of the liquid inside the capillary, the measurement coordinate points of the vapor–liquid interface line were measured. A new method for measuring liquid contact angle has been proposed, which was used to calculate the actual coordinate points and fit the actual vapor–liquid interface line of the liquid. Finally, an angle measurement tool is used to measure the angle of the actual vapor–liquid interface line and obtain the actual contact angle of the liquid. Effectively reducing the influence of refraction on the contact angle by correcting the errors caused by the refractive index of different materials, it can be used for the precise measurement of the static contact angle of liquids. By measuring the static contact angle of the upper and lower liquid surfaces of the liquid column, it was found that the presence of refraction caused a difference of [1.84°, 5.61°] between the actual and measured values of the static contact angle.
- Open Access
- 26 March 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (7) , 2722
Review of Operation Performance and Application Status of Pulsating Heat Pipe
Due to the rapid development of science and technology in today’s era, electronic equipment is constantly upgrading. Today, the developmental trend of electronic equipment is miniaturization, portability and multi-functionality. However, multi-functionality often means multi-components, so it is undoubtedly a great test of heat dissipation ability to accommodate more components in a smaller volume. Without sufficient heat dissipation capacity, a large number of components will stop working or even be damaged because of the heat generated during operation. As a new passive cooling and heat exchange technology, pulsating heat pipes have many advantages, such as having no external energy input, a simple structure, changeable installation forms and low installation requirements. They have shown great potential in the field of thermal management, and have attracted a lot of scholars’ attention since they were put forward. Because of their operational stability and heat exchange ability in high heat flux environments, they are the best choice for cooling electronic equipment at present. If they can be fully studied and utilized, pulsating heat pipes can not only reduce the consumption of heat dissipation resources but also reuse heat energy to realize the sustainable utilization of resources. This paper briefly introduces the demand background and structural principle of pulsating heat pipes, and summarizes the research on the parameters of pulsating heat pipes and the application status of pulsating heat pipes. The parameters involve working fluid type, pipe diameter, elbow number, liquid filling rate, inclination angle, etc. After classifying the parameters that affect the operation results of pulsating heat pipes, this paper summarizes the research at this stage, and points out the lack of research fields, such as heat flux density, and new application fields of unconventional gravity environment by combining the literature content with the current scientific and technological development trends and experimental parameters, such as thermodynamics.
- 26 March 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (7) , 2722
Open AccessReview of Operation Performance and Application Status of Pulsating Heat Pipe
Due to the rapid development of science and technology in today’s era, electronic equipment is constantly upgrading. Today, the developmental trend of electronic equipment is miniaturization, portability and multi-functionality. However, multi-functionality often means multi-components, so it is undoubtedly a great test of heat dissipation ability to accommodate more components in a smaller volume. Without sufficient heat dissipation capacity, a large number of components will stop working or even be damaged because of the heat generated during operation. As a new passive cooling and heat exchange technology, pulsating heat pipes have many advantages, such as having no external energy input, a simple structure, changeable installation forms and low installation requirements. They have shown great potential in the field of thermal management, and have attracted a lot of scholars’ attention since they were put forward. Because of their operational stability and heat exchange ability in high heat flux environments, they are the best choice for cooling electronic equipment at present. If they can be fully studied and utilized, pulsating heat pipes can not only reduce the consumption of heat dissipation resources but also reuse heat energy to realize the sustainable utilization of resources. This paper briefly introduces the demand background and structural principle of pulsating heat pipes, and summarizes the research on the parameters of pulsating heat pipes and the application status of pulsating heat pipes. The parameters involve working fluid type, pipe diameter, elbow number, liquid filling rate, inclination angle, etc. After classifying the parameters that affect the operation results of pulsating heat pipes, this paper summarizes the research at this stage, and points out the lack of research fields, such as heat flux density, and new application fields of unconventional gravity environment by combining the literature content with the current scientific and technological development trends and experimental parameters, such as thermodynamics.
- 5 February 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 85, 108724
Modelling of regional heating and cooling load in the context of carbon neutrality
- 5 February 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 85, 108724
Modelling of regional heating and cooling load in the context of carbon neutrality
- Open Access
- 14 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (6) , 5118
Research on Application and International Policy of Renewable Energy in Buildings
It has been proposed in China that the country should reach a “carbon peak” by 2030 and be “carbon neutral” by 2060. In the context of energy conservation and emission reduction, the country’s energy structure needs to be transformed to improve the technology level and more widespread consumption of renewable energy. The global renewable energy utilization situation is first analyzed in this study from the perspective of renewable energy and the buildings using it, highlighting the importance of the application of renewable energy in buildings. Secondly, from the perspective of solar energy utilization technology, ground source heat pump technology, and systems for managing energy use in buildings, the progressiveness of renewable energy applications in buildings is analyzed. The application of these technologies in buildings is demonstrated from various angles. Thirdly, the development prospect of buildings using renewable energy is discussed from the perspective of the promotion of renewable energy-powered buildings and green construction. The development prospects of buildings using renewable energy are discussed from the economic benefits of green finance, the promotion and social support of renewable energy, and the environmental benefits of green buildings. Finally, based on studies in the United States, the United Kingdom, Russia, and China, the international energy policy and development direction, as well as the evaluation criteria of green buildings, are discussed, along with an assessment system for green buildings that is complementary to the strategic agreement.
- 14 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (6) , 5118
Open AccessResearch on Application and International Policy of Renewable Energy in Buildings
It has been proposed in China that the country should reach a “carbon peak” by 2030 and be “carbon neutral” by 2060. In the context of energy conservation and emission reduction, the country’s energy structure needs to be transformed to improve the technology level and more widespread consumption of renewable energy. The global renewable energy utilization situation is first analyzed in this study from the perspective of renewable energy and the buildings using it, highlighting the importance of the application of renewable energy in buildings. Secondly, from the perspective of solar energy utilization technology, ground source heat pump technology, and systems for managing energy use in buildings, the progressiveness of renewable energy applications in buildings is analyzed. The application of these technologies in buildings is demonstrated from various angles. Thirdly, the development prospect of buildings using renewable energy is discussed from the perspective of the promotion of renewable energy-powered buildings and green construction. The development prospects of buildings using renewable energy are discussed from the economic benefits of green finance, the promotion and social support of renewable energy, and the environmental benefits of green buildings. Finally, based on studies in the United States, the United Kingdom, Russia, and China, the international energy policy and development direction, as well as the evaluation criteria of green buildings, are discussed, along with an assessment system for green buildings that is complementary to the strategic agreement.
- Open Access
- 19 January 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (3) , 1921
Influence of Cooling Water Flow Rate on Start and Heat Transfer Performance of Pulsating Heat Pipe at Different Inclination Angles
Pulsating heat pipe (PHP) is an efficient heat transfer technology applied in the fields of heat dissipation and energy utilization. There are many factors affecting the heat transfer of PHP, including working fluid, filling ratio, inclination angle, etc. The cooling capacity of the cooling water system at the condensing section to the working fluid is also an important factor affecting the starting and operating of PHP. The research on PHP at different cooling water flow rates is of great significance for enhancing the operating performance. An experimental investigation of starting and running performance is carried out on a closed loop PHP with ultrapure water under different inclination angles of 90°, 60° and 30°. The starting and heat transfer performance of PHP with a filling ratio of 50% is obtained by adjusting the heat input in the range of 30–210 W at different cooling water flow rates of 6.7 g/s, 9.7 g/s and 13.9 g/s. The temperature and heat transfer resistance are used for analyzing the heat transfer performance. The results show that the starting mode, initial pulsating temperature and different heat transfer effects are brought about by different cooling water flow rates. It is observed that the cooling water flow rate has no obvious influence on the starting mode of PHP and that the starting mode of PHP is temperature progressive, starting with the increase in cooling water flow rates at a heating input of about 30 W. The influence of cooling water flow rates on the heat transfer performance of PHP is affected in a different way by inclination angles. The heat transfer performance of PHP with an inclination angle of 90° is similar at 6.7 g/s, 9.7 g/s and 13.9 g/s but, under the condition of 60° and 30°, the heat transfer resistance drops within a certain range effectively with an increasing cooling water flow rate from 6.7 g/s to 9.7 g/s and the heat transfer performance does not change significantly with the cooling water flow rate increasing to 13.9 g/s. Thus, there is an optimal value for the cooling water flow rate during the operating of PHP. The inclination angle also has an important effect on the temperature pulsating, and the temperature of PHP affected by gravity is stable with an inclination angle of 90°. However, the reduced influence of gravity on the backflow of the working fluid drops when the inclination angle decreases from 90° to 30°, and the wall temperature increases due to local overheating when the high heat input occurs.
- 19 January 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (3) , 1921
Open AccessInfluence of Cooling Water Flow Rate on Start and Heat Transfer Performance of Pulsating Heat Pipe at Different Inclination Angles
Pulsating heat pipe (PHP) is an efficient heat transfer technology applied in the fields of heat dissipation and energy utilization. There are many factors affecting the heat transfer of PHP, including working fluid, filling ratio, inclination angle, etc. The cooling capacity of the cooling water system at the condensing section to the working fluid is also an important factor affecting the starting and operating of PHP. The research on PHP at different cooling water flow rates is of great significance for enhancing the operating performance. An experimental investigation of starting and running performance is carried out on a closed loop PHP with ultrapure water under different inclination angles of 90°, 60° and 30°. The starting and heat transfer performance of PHP with a filling ratio of 50% is obtained by adjusting the heat input in the range of 30–210 W at different cooling water flow rates of 6.7 g/s, 9.7 g/s and 13.9 g/s. The temperature and heat transfer resistance are used for analyzing the heat transfer performance. The results show that the starting mode, initial pulsating temperature and different heat transfer effects are brought about by different cooling water flow rates. It is observed that the cooling water flow rate has no obvious influence on the starting mode of PHP and that the starting mode of PHP is temperature progressive, starting with the increase in cooling water flow rates at a heating input of about 30 W. The influence of cooling water flow rates on the heat transfer performance of PHP is affected in a different way by inclination angles. The heat transfer performance of PHP with an inclination angle of 90° is similar at 6.7 g/s, 9.7 g/s and 13.9 g/s but, under the condition of 60° and 30°, the heat transfer resistance drops within a certain range effectively with an increasing cooling water flow rate from 6.7 g/s to 9.7 g/s and the heat transfer performance does not change significantly with the cooling water flow rate increasing to 13.9 g/s. Thus, there is an optimal value for the cooling water flow rate during the operating of PHP. The inclination angle also has an important effect on the temperature pulsating, and the temperature of PHP affected by gravity is stable with an inclination angle of 90°. However, the reduced influence of gravity on the backflow of the working fluid drops when the inclination angle decreases from 90° to 30°, and the wall temperature increases due to local overheating when the high heat input occurs.
- Open Access
- 7 January 2023
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 11 (1) , 140
Objective Functions and Performance Optimization of Ocean Thermal Energy Conversion (OTEC) with CO2-Based Binary Zeotropic Mixture Power Cycle
Ocean thermal energy is a huge renewable and clean energy. For different applications of the Ocean Thermal Energy Conversion (OTEC) system, new objective functions are proposed and optimal CO2-based binary zeotropic mixtures for each objective function are discussed. Propane, butane, isobutane, and pentane were selected as the secondary component of the mixture working fluid. Based on each objective function, some parameters of the CO2-based binary zeotropic mixture power cycle were studied and the optimal working fluids were obtained. The results indicated that the thermal efficiency showed an upwards trend as the evaporating temperature increased from 20 to 23 °C and decreased as the molar fraction of the secondary component of the working fluid increased from 0.01 to 0.05, but the specific volumetric flow showed the opposite trend. The specific net power increased as the evaporating temperature increased, and the net power output had a greater effect on the variations in the specific net power than the molar fraction of the secondary component. When taking thermal efficiency or specific volumetric flow as the objective functions, CO2/propane was the suitable working fluid under the considered conditions; in the case that specific net power was taken as the objective function, CO2/butane (0.97/0.03 or 0.96/0.04 molar ratio) or CO2/isobutane (0.97/0.03, 0.96/0.04, or 0.95/0.05 molar ratio) were suitable under the considered evaporating temperature.
- 7 January 2023
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 11 (1) , 140
Open AccessObjective Functions and Performance Optimization of Ocean Thermal Energy Conversion (OTEC) with CO2-Based Binary Zeotropic Mixture Power Cycle
Ocean thermal energy is a huge renewable and clean energy. For different applications of the Ocean Thermal Energy Conversion (OTEC) system, new objective functions are proposed and optimal CO2-based binary zeotropic mixtures for each objective function are discussed. Propane, butane, isobutane, and pentane were selected as the secondary component of the mixture working fluid. Based on each objective function, some parameters of the CO2-based binary zeotropic mixture power cycle were studied and the optimal working fluids were obtained. The results indicated that the thermal efficiency showed an upwards trend as the evaporating temperature increased from 20 to 23 °C and decreased as the molar fraction of the secondary component of the working fluid increased from 0.01 to 0.05, but the specific volumetric flow showed the opposite trend. The specific net power increased as the evaporating temperature increased, and the net power output had a greater effect on the variations in the specific net power than the molar fraction of the secondary component. When taking thermal efficiency or specific volumetric flow as the objective functions, CO2/propane was the suitable working fluid under the considered conditions; in the case that specific net power was taken as the objective function, CO2/butane (0.97/0.03 or 0.96/0.04 molar ratio) or CO2/isobutane (0.97/0.03, 0.96/0.04, or 0.95/0.05 molar ratio) were suitable under the considered evaporating temperature.
- Open Access
Optimization Study on Fluids for the Gravity-Driven Organic Power Cycle
The organic Rankine cycle (ORC) is efficient in using low-grade heat energy, while low pump efficiency and high pump leakage are usually serious problems. A gravity-driven organic power cycle (GDOPC) uses gravity instead of a pump to pressurize working fluid and has the potential to avoid problems associated with the pump. A theoretical method is used to study the performance and suitability of several fluids for GDOPC. The results show that the flow efficiency in high vertical pipes and the pump efficiency determine whether GDOPC gives better performance than ORC or not. When R245fa is selected as working fluid and evaporating temperature is 62 °C, specific energy of GDOPC (flow efficiency is 80%) is 2.5% higher than that of ORC (pump efficiency is 60%). The improvement degree of specific energy and the liquid column height increase with increasing evaporating temperature. R1234yf and R227ea give good performance with specific energy of 4.84 kJ/kg and 4.82 kJ/kg, respectively, while they need a liquid column as much as 76.55 m and 45.65 m, respectively. Although R365mfc and cyclopentane do not give the most excellent cycle performance, they need liquid column height as low as 9.04 m and 10.88 m, respectively. Fluid with low saturated pressure and high density may need low liquid column height and has the advantage to be used in practical applications.
Open AccessOptimization Study on Fluids for the Gravity-Driven Organic Power Cycle
The organic Rankine cycle (ORC) is efficient in using low-grade heat energy, while low pump efficiency and high pump leakage are usually serious problems. A gravity-driven organic power cycle (GDOPC) uses gravity instead of a pump to pressurize working fluid and has the potential to avoid problems associated with the pump. A theoretical method is used to study the performance and suitability of several fluids for GDOPC. The results show that the flow efficiency in high vertical pipes and the pump efficiency determine whether GDOPC gives better performance than ORC or not. When R245fa is selected as working fluid and evaporating temperature is 62 °C, specific energy of GDOPC (flow efficiency is 80%) is 2.5% higher than that of ORC (pump efficiency is 60%). The improvement degree of specific energy and the liquid column height increase with increasing evaporating temperature. R1234yf and R227ea give good performance with specific energy of 4.84 kJ/kg and 4.82 kJ/kg, respectively, while they need a liquid column as much as 76.55 m and 45.65 m, respectively. Although R365mfc and cyclopentane do not give the most excellent cycle performance, they need liquid column height as low as 9.04 m and 10.88 m, respectively. Fluid with low saturated pressure and high density may need low liquid column height and has the advantage to be used in practical applications.