MMMuhammad Saiful Badri Mansor

Muhammad Saiful Badri Mansor

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Muhammad Saiful Badri Mansor has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Magnetic Induction Tomography: A Brief Review

    by Muhammad Saiful Badri Mansor, Zulkarnay Zakaria, Ibrahim Balkhis, Ruzairi Abdul Rahim, Mohd Fadzli Abdul Sahib, Yusri Md. Yunos, Shafishuhaza Sahlan, Salinda Bunyamin, Khairul Hamimah Abas, Mohd Hafis Izran Ishak, et al.

    Magnetic Induction Tomography (MIT) is a contactless non-invasive imaging technique that interested in mapping the passive electrical properties of a material; conductivity, permittivity and permeability. This paper presents the criteria and previous functional specification involving the development of MIT, focusing in conductivity imaging. Various ways have been implemented from a simple electronic configuration of the front-end sensory circuit, data acquisition system, reconstruction algorithm and graphical user interfacing (GUI) tools. Induction sensors are paramount as it does provide the signal source for time varying magnetic field to the coils. The advantages and limitations of MIT are also presented. Many more advancement can be expected to enhance the lack of MIT especially in spatial resolution and dynamic response of the sensor.


  • Magnetic Induction Tomography: Receiver Circuit and Its Design Criteria

    by Zulkarnay Zakaria, Muhammad Saiful Badri Mansor, Ruzairi Abdul Rahim, Ibrahim Balkhis, Mohd Hafiz Fazalul Rahiman, Nor Muzakkir Nor Ayob, Herlina Abdul Rahim, Sazali Yaacob

    This paper discusses the receiver circuit and criteria for component selection towards the application of a real-time magnetic induction tomography system. Component selection plays an important role since image reconstruction of the object of interest with high quality and at a higher frame rate cannot be achieved without the right parameter criteria. The demands for a high quality imaging system have recently been increasing, especially in industrial processes involving dynamic movement, thus this paper may provide valuable information on better magnetic induction tomography system implementation for industrial processes and biomedical imaging through the use of a coil as a transmitter and also a receiver. The linear back projection algorithm has been employed in this system and has proven capable of identifying the location and size of the object based on the reconstructed images.


  • Study of the Effect of Brightness After Penetration of Light from a Lens

    by Mohd Fahajumi Jumaah, Mohd Zikrillah Zawahir, Fazlul Rahman Mohd Yunus, Ruzairi Abdul Rahim, Nor Muzakkir Nor Ayob, Muhammad Saiful Badri Mansor, Naizatul Shima Fadzil, Zulkarnay Zakaria, Mohd Hafiz Fazalul Rahiman

    There are many types of component that are able to produce light and the light is produced based on the angle and wavelength of the lens. Light penetration depends on the type of material used. The tests are done using basic electronic components which are able to produce light including the light emitting diode (LED), laser and infrared source. From the component, there are two types of light line, one with an angle and one without. It is known that the laser only produces a straight line light while the angle and thickness of light from both the LED, and infrared source increase with distance. The results show that the different types of light must use different types of lenses and they are suitable for use with all light properties.

  • Open Access

    Advancements in Transmitters and Sensors for Biological Tissue Imaging in Magnetic Induction Tomography

    by Zulkarnay Zakaria, Ruzairi Abdul Rahim, Muhammad Saiful Badri Mansor, Sazali Yaacob, Nor Muzakkir Nor Ayob, Siti Zarina Mohd. Muji, Mohd Hafiz Fazalul Rahiman, Syed Mustafa Kamal Syed Aman

    Magnetic Induction Tomography (MIT), which is also known as Electromagnetic Tomography (EMT) or Mutual Inductance Tomography, is among the imaging modalities of interest to many researchers around the world. This noninvasive modality applies an electromagnetic field and is sensitive to all three passive electromagnetic properties of a material that are conductivity, permittivity and permeability. MIT is categorized under the passive imaging family with an electrodeless technique through the use of excitation coils to induce an electromagnetic field in the material, which is then measured at the receiving side by sensors. The aim of this review is to discuss the challenges of the MIT technique and summarize the recent advancements in the transmitters and sensors, with a focus on applications in biological tissue imaging. It is hoped that this review will provide some valuable information on the MIT for those who have interest in this modality. The need of this knowledge may speed up the process of adopted of MIT as a medical imaging technology.


  • Infrared Tomography Sensor Configuration Using 4 Parallel Beam Projections

    by Yusri Md.Yunos, Muhammad Saiful Badri Mansor, Nor Muzakkir Nor Ayob, Pang Jon Fea, Ruzairi Abdul Rahim, Chan Kok San

    Penyelidikan ini menunjukkan konfigurasi sensor tomografi optik dengan penggunaan pemancar inframerah dan foto transistor. Geometri unjuran sensor adalah berdasarkan kombinasi dua unjuran oktagon dan dua unjuran garis lurus tatasusunan. Sebuah perlengkapan direka untuk memegang keseluruhan pasangan pemancar–penerima secara selari. Pemilihan foto transistor juga dijelaskan supaya pembangunan sensor tomografi adalah bebas dari bacaan yang tidak diingini daripada persekitaran sekeliling. Penulisan ini juga menerangkan perkara–perkara yang perlu dipertimbangkan untuk pembangunan sensor tomografi optikal. Kata kunci: Inframerah; tomografi optikal This paper represents the configuration of optical tomography sensor by using infrared emitter and phototransistor. The projection geometry of the sensor is based on the combination of two orthogonal and two rectilinear projections arrays. A fixture is designed for holding all emitter–receiver pairs in parallel. Selection of phototransistor is explained so that the tomography sensor developed is free of noise cause by surrounding environment. This paper describes all points to be considered when design an optical tomography sensor. Key words: Infrared; optical tomography

  • Optical Tomography: Real–Time Image Reconstruction System Using Two Data Processing Units

    by Ruzairi Abdul Rahim, Pang Jon Fea, Normuzakkir Nor Ayob, Muhammad Saiful Badri Mansor, Herlina Abdul Rahim, Yusri Md Yunus

    Penyelidikan dilakukan untuk memeriksa jika penggunaan dua unit pemprosesan data boleh meningkatkan kadar penghasilan imej ketika mod masa nyata. Fungsi unit–unit pemprosesan data adalah masing–masing untuk merekod data, membina semula dan memaparkan imej. Perbandingan antara hasil yang direkodkan dan kadar penghasilan imej masa–nyata dilakukan menggunakan unit pemprosesan tunggal. Graf peningkatan peratusan melawan berlainan resolusi menggambarkan prestasi system pembinaan semua imej dengan menggunakan dua unit pemprosesan data. Kata kunci: Unit pemprosesan data; kadar penghasilan imej An investigation is performed to investigate whether or not using two data processing units can increase image refreshing rate in online mode. The functions of these data processing units are capturing data, reconstructing and displaying the image respectively. The measured results are compared with real–time image refreshing rate using a single processing unit. The graph of percentage improvement versus various resolutions represents the performance of the image reconstruction system using two data processing units. Key words: Data processing unit; image refreshing rate

  • Simulation study on size and location identification of tumors in liver tissue through eddy current distribution analysis

    by Zulkarnay Zakaria, Lee Pick Yern, Azian Azamimi Abdullah, Ruzairi Abdul Rahim, Muhammad Saiful Badri Mansor, Nor Muzakkir Nor Ayob

    In identifying the location of tumors in the liver, eddy current characteristics analysis can be applied since the conductivity value of normal tissue and tissue with tumors are different, which are 2.88 mS/cm and 5.33 mS/cm, respectively at 1 MHz. In this letter, simulation based on small scale magnetic induction system was carried out. The system consists of a 10 cm diameter sensor jig and a cone type screen excitation coil as the primary field source. Simulation results showed that eddy current analysis is capable of identifying location and size of tumors in a liver tissue phantom. This result may have an impact in Magnetic Induction Tomography (MIT) research since MIT imaging modality is based on electrical conductivity property of the material of interest.


  • Simulation of electromagnetic field (EM) focusing capability on biological tissue through the application of C-type excitation coil screen

    by Zulkarnay Zakaria, Noor Alia Mohd Zain, Azian Azamimi Abdullah, Sofi Yahya, Ruzairi Abdul Rahim, Muhammad Saiful Badri Mansor, Abdul Rahim Mohd Disar

    In Magnetic Induction Tomography (MIT) or Electromagnetic Therapy system, excitation coil is applied with AC source in generating the electromagnetic (EM) field which then propagate and penetrate the object located in the region of interest (ROI). However, instead to the target object, the fields also propagate around the coil and create interference to the nearby circuit which contributes noise to the system while at the same time wasting the energy. This paper is focusing on the use of C-type excitation coil screen in focusing the EM field to the ROI and measure the penetration depth when different frequency is applied to the generation system.


  • The effect of parallel projection towards image performance

    by Siti Zarina Mohd Muji, Ruzairi Abdul Rahim, Leow Pei Ling, Mohd Hafiz Fazalul Rahiman, Mohd Fadzli Abd Shaib, Nor Muzakkir Nor Ayob, Elmy Johana Mohamad, Zulkarnay Zakaria, Muhammad Jaysuman Puspanathan, Muhammad Saiful Badri Mansor, et al.

    In tomography, there are two common projection namely, parallel beam and fan beam. Both projections give a different impact towards system performance and the image itself. This paper will focus on the attenuation factor that affects towards images in parallel projection. The focuses are to see the differences between one, two, three and four projections towards image performance. The projection is come from light that is produced by LED infrared while photodiode is act as receiver. Any appearance of object between transmitter and receiver will change the voltage that is produce by receiver. The bigger the object, the more voltage losses will be sensed. The voltage loss will be manipulated to form an image where it is found out that the more the projection is applied, the image will be displayed clearer and have more information on it.


  • Simulation of magnetic flux leakage (MFL) analysis using FEMM software

    by Zulkarnay Zakaria, Muhammad Saiful Badri Mansor, Aishah Hartini Jahidin, Mohd Shuhanaz Zanar Azlan, Ruzairi Abdul Rahim

    Magnetic flux leakage (MFL) is a method used in oil and gas piping systems which has potential in medical gas piping inspection, cleaning and gauging tasks without interrupting the pipeline transportation process. MFL is a magnetic method of nondestructive testing that applies a magnet to magnetize the steel. At areas where there is corrosion or missing metal, the magnetic field "leaks" from the steel. In this research, a system that is capable of simulating a magnetic flux leakage of different types of crack was modeled using the Finite Element Method of Magnetic (FEMM). A portion of pipelines that may contain several cracks were introduced into the software by entering all the properties needed in order to simulate the output in the magnetic field distribution and graphical representation. The disturbance in magnetic field will result in small displacement in the field. The displacement in the fields carries the actual information about the condition of the pipeline.